Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Industry Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

An Update to a Conformal Ablative Thermal Protection System for Planetary and Human Exploration Missions

As described at IPPW-10, in FY12, the CA-TPS element focused on establishing materials requirements based on MSL-type and COTS Low Earth orbit (LEO) conditions (q 250 Wcm2) to develop and deliver a conformal ablative TPS. This involved down selecting, manufacturing and testing two of the best candidate materials, demonstrating uniform infiltration of resins into baseline 2-cm thick carbon felt, selecting a primary conformal material formulation based on novel arc jet and basic material properties testing, developing and demonstrating instrumentation for felt-based materials and, based on the data, developing a low fidelity material response model so that the conformal ablator TPS thickness for missions could be established. In addition, the project began to develop Industry Partnerships. Since the nominal thickness of baseline carbon felts was only 2-cm, a partnership with a rayon felt developer was made in order to upgrade equipment, establish the processes required and attempt to manufacture 10-cm thick white goods. A partnership with a processing house was made to develop the methodology to carbonize large pieces of the white goods into 7.5-cm thick carbon felt. In FY13, more advanced testing and modeling of the down selected conformal material was performed. Material thermal properties tests and structural properties tests were performed. The first 3 and 4-point bend tests were performed on the conformal ablator as well as PICA for comparison and the conformal ablator had outstanding behavior compared to PICA. Arc jet testing was performed with instrumented samples of both the conformal ablator and standard PICA at heating rates ranging from 40 to 400 Wcm2 and shear as high as 600 Pa. The results from these tests showed a remarkable improvement in the thermal penetration through the conformal ablator when compared to PICAs response. The data from these tests were used to develop a mid-fidelity thermal response model. Additional arc jet testing in the same conditions on various seam designs were very successful in showing that the material could be joined with a minimum of adhesive and required no complicated gap and gap filler design for installation. In addition, the partnership with industry to manufacture thicker rayon felt was very successful. The vendor made a 2-m wide by 30-m long sample of 10-cm thick rayon felt. When carbonized, the resulting thickness was over 7.5-cm thick, nearly 4 times the thickest off-the-shelf carbon felt. In FY14, the project has initiated a partnership with another vendor to begin the scale-up manufacturing effort. This year, the vendor will duplicate the process and manufacture at the current scale for comparison with NASA-processed materials. Properties testing and arc jet testing will be performed on the vendor-processed materials. Planning for manufacturing large, 1-m x 1-m, panels will begin as well. In FY15, the vendor will then manufacture large panels and the project will build a 2-m x 2-m Manufacturing Demonstration Unit (MDU).

Ablative materials↗

Air pollution source identification

Techniques for air pollution source identification are reviewed, and some results obtained with them are evaluated. Described techniques include remote sensing from satellites and aircraft, on-site monitoring, and the use of injected tracers and pollutants themselves as tracers. The use of a large number of trace elements in ambient airborne particulate matter as a practical means of identifying sources is discussed in detail. Sampling and analysis techniques are described, and it is shown that elemental constituents can be related to specific source types such as those found in the earth's crust and those associated with specific industries. Source identification sytems are noted which utilize charged particle X-ray fluorescence analysis of original field data.

Fordyce, J. S.↗

Revealing the microstructure of materials

The objectives are to demonstrate how the microstructure of materials may be revealed by abrasive polishing and chemical etching, and to illustrate how microstructural information is used to monitor manufacturing processes, provide in-depth inspection, and perform failure analysis. Microstructural analysis is the procedure used to reveal the internal microstructural details of a material or part by sectioning and polishing the cut surface so that it may be examined under a suitable microscope. A printed wiring board was selected as the test material because it contains both metals and nonmetals that have distinctive microstructures, and because this technique is used throughout the electronic industry as a key quality control tool. The three principle component materials in printed circuit boards are glass/epoxy laminates faced with copper foil; copper, deposited by both electroless and electrolytic plating; and tin/lead solder. Sample preparation, mounting, grinding, polishing, and examination and analysis are discussed.

Nelson, James A.↗

Maximizing Macromolecule Crystal Size for Neutron Diffraction Experiments

A challenge in neutron diffraction experiments is growing large (greater than 1 cu mm) macromolecule crystals. In taking up this challenge we have used statistical experiment design techniques to quickly identify crystallization conditions under which the largest crystals grow. These techniques provide the maximum information for minimal experimental effort, allowing optimal screening of crystallization variables in a simple experimental matrix, using the minimum amount of sample. Analysis of the results quickly tells the investigator what conditions are the most important for the crystallization. These can then be used to maximize the crystallization results in terms of reducing crystal numbers and providing large crystals of suitable habit. We have used these techniques to grow large crystals of Glucose isomerase. Glucose isomerase is an industrial enzyme used extensively in the food industry for the conversion of glucose to fructose. The aim of this study is the elucidation of the enzymatic mechanism at the molecular level. The accurate determination of hydrogen positions, which is critical for this, is a requirement that neutron diffraction is uniquely suited for. Preliminary neutron diffraction experiments with these crystals conducted at the Institute Laue-Langevin (Grenoble, France) reveal diffraction to beyond 2.5 angstrom. Macromolecular crystal growth is a process involving many parameters, and statistical experimental design is naturally suited to this field. These techniques are sample independent and provide an experimental strategy to maximize crystal volume and habit for neutron diffraction studies.

Judge, R. A.↗

Surface-Moisture Monitoring Technique

Technique monitors drying of continuous sheets of thin material. Ribbon sensing element samples moisture content of web material during each rotation of roller. Change in resistivity of thermally and electrically conductive ribbon is parameter used to measure web moisture; measurements insensitive to ribbon contact pressure. Application in industrial production of sheet materials such as paper and fabric.

Yang, L. C.↗

Exploration of the Moon with Remote Sensing, Ground-Penetrating Radar, and the Regolith-Evolved Gas Analyzer (REGA)

There are two important reasons to explore the Moon. First, we would like to know more about the Moon itself: its history, its geology, its chemistry, and its diversity. Second, we would like to apply this knowledge to a useful purpose. namely finding and using lunar resources. As a result of the recent Clementine and Lunar Prospector missions, we now have global data on the regional surface mineralogy of the Moon, and we have good reason to believe that water exists in the lunar polar regions. However, there is still very little information about the subsurface. If we wish to go to the lunar polar regions to extract water, or if we wish to go anywhere else on the Moon and extract (or learn) anything at all, we need information in three dimensions an understanding of what lies below the surface, both shallow and deep. The terrestrial mining industry provides an example of the logical steps that lead to an understanding of where resources are located and their economic significance. Surface maps are examined to determine likely locations for detailed study. Geochemical soil sample surveys, using broad or narrow grid patterns, are then used to gather additional data. Next, a detailed surface map is developed for a selected area, along with an interpretation of the subsurface structure that would give rise to the observed features. After that, further sampling and geophysical exploration are used to validate and refine the original interpretation, as well as to make further exploration/ mining decisions. Integrating remotely sensed, geophysical, and sample datasets gives the maximum likelihood of a correct interpretation of the subsurface geology and surface morphology. Apollo-era geophysical and automated sampling experiments sought to look beyond the upper few microns of the lunar surface. These experiments, including ground-penetrating radar and spectrometry, proved the usefulness of these methods for determining the best sites for lunar bases and lunar mining operations.

Cooper, B. L.↗

Sealed container sampling device

Sampling device, by means of a tapered needle, pierces a sealed container while maintaining the seal and either evacuates or pressurizes the container. This device has many applications in the chemical, preservative and battery-manufacturing industries.

Hennigan, T. J.↗

An Approach to Application of Multispectral Sensors, using AVIRIS Data

High spatial resolution multispectral/hyperspectral sensors are being developed by private industry with science/research customers as end users. With an increasingly wide range of sensor choices, it is important for the remote sensing science community and commercial community alike to understand the trade-offs between ground sample distance (GSD), spectral resolution, and signal-to-noise ratio (SNR) in selecting a sensor that will best meet their needs. High spatial resolution hyperspectral imagery and super resolution multispectral charge-coupled device imagery can be used to develop prototypes of proposed data acquisition systems without building new systems or collecting large sets of additional data. By using these datasets to emulate proposed and existing systems, imaging systems may be optimized to meet customer needs in a virtual environment. This approach also enables one to determine, a priori, whether an existing dataset will be useful for a given application.

Warner, Amanda↗

First International Diagnosis Competition - DXC'09

A framework to compare and evaluate diagnosis algorithms (DAs) has been created jointly by NASA Ames Research Center and PARC. In this paper, we present the first concrete implementation of this framework as a competition called DXC 09. The goal of this competition was to evaluate and compare DAs in a common platform and to determine a winner based on diagnosis results. 12 DAs (model-based and otherwise) competed in this first year of the competition in 3 tracks that included industrial and synthetic systems. Specifically, the participants provided algorithms that communicated with the run-time architecture to receive scenario data and return diagnostic results. These algorithms were run on extended scenario data sets (different from sample set) to compute a set of pre-defined metrics. A ranking scheme based on weighted metrics was used to declare winners. This paper presents the systems used in DXC 09, description of faults and data sets, a listing of participating DAs, the metrics and results computed from running the DAs, and a superficial analysis of the results.

Kurtoglu, tolga↗

Mechanics of Granular Materials (MGM)

The constitutive behavior of uncemented granular materials such as strength, stiffness, and localization of deformations are to a large extend derived from interparticle friction transmitted between solid particles and particle groups. Interparticle forces are highly dependent on gravitational body forces. At very low effective confining pressures, the true nature of the Mohr envelope, which defines the Mohr-Coulomb failure criterion for soils, as well as the relative contribution of each of non-frictional components to soil's shear strength cannot be evaluated in terrestrial laboratories. Because of the impossibility of eliminating gravitational body forces on earth, the weight of soil grains develops interparticle compressive stresses which mask true soil constitutive behavior even in the smallest samples of models. Therefore the microgravity environment induced by near-earth orbits of spacecraft provides unique experimental opportunities for testing theories related to the mechanical behavior of terrestrial granular materials. Such materials may include cohesionless soils, industrial powders, crushed coal, etc. This paper will describe the microgravity experiment, 'Mechanics of Granular Materials (MGM)', scheduled to be flown on Space Shuttle-MIR missions. The paper will describe the experiment's hardware, instrumentation, specimen preparation procedures, testing procedures in flight, as well as a brief summary of the post-mission analysis. It is expected that the experimental results will significantly improve the understanding of the behavior of granular materials under very low effective stress levels.

Alshibli, Khalid A.↗

Longitudinal variations of very-low-frequency chorus activity in the magnetosphere - Evidence of excitation by electrical power transmission lines

The distribution of VLF chorus in the high-altitude magnetosphere as detected by the Ogo 3 satellite was investigated. Chorus occurrence frequency over 4,668 samples of 5 min of broadband data was computed for Northern Hemisphere bins of 10 deg by 10 deg in dipole invariant latitude and longitude. Peaks in activity were noted over Alaska, the eastern U.S. and Canada, western Europe, and western Siberia, and were shown not to be the result of biased sampling. It is suggested that power line radiation of only about 1 W or less at a given harmonic frequency may be sufficient to stimulate the observed chorus activity and that such power levels can be expected in industrial areas or from large distribution networks. Preliminary results show that chorus starting frequencies are highly correlated with 60 Hz harmonics in the American sector and with 50 Hz harmonics in the European sector.

Luette, J. P.↗

Instrumentation for Measurement of Gas Permeability of Polymeric Membranes

A mass spectrometric 'Dynamic Delta' method for the measurement of gas permeability of polymeric membranes has been developed. The method is universally applicable for measurement of the permeability of any gas through polymeric membrane materials. The usual large sample size of more than 100 square centimeters required for other methods is not necessary for this new method which requires a size less than one square centimeter. The new method should fulfill requirements and find applicability for industrial materials such as food packaging, contact lenses and other commercial materials where gas permeability or permselectivity properties are important.

Upchurch, Billy T.↗

Estimation of Daily PM(sub 10) Concentrations in Italy (2006-2012) Using Finely Resolved Satellite Data, Land Use Variables and Meteorology

Health effects of air pollution, especially particulate matter (PM), have been widely investigated. However, most of the studies rely on few monitors located in urban areas for short-term assessments, or land use/dispersion modelling for long-term evaluations, again mostly in cities. Recently, the availability of finely resolved satellite data provides an opportunity to estimate daily concentrations of air pollutants over wide spatio-temporal domains. Italy lacks a robust and validated high resolution spatio-temporally resolved model of particulate matter. The complex topography and the air mixture from both natural and anthropogenic sources are great challenges difficult to be addressed. We combined finely resolved data on Aerosol Optical Depth (AOD) from the Multi-Angle Implementation of Atmospheric Correction (MAIAC) algorithm, ground-level PM10measurements, land-use variables and meteorological parameters into a four-stage mixed model framework to derive estimates of daily PM10concentrations at 1-km2 grid over Italy, for the years 2006-2012. We checked performance of our models by applying 10-fold cross-validation (CV) for each year. Our models displayed good fitting, with mean CV-R2=0.65 and little bias (average slope of predicted VS observed PM10=0.99). Out-of-sample predictions were more accurate in Northern Italy (Po valley) and large conurbations (e.g. Rome), for background monitoring stations, and in the winter season. Resulting concentration maps showed highest average PM10levels in specific areas (Po river valley, main industrial and metropolitan areas) with decreasing trends over time. Our daily predictions of PM10concentrations across the whole Italy will allow, for the first time, estimation of long-term and short-term effects of air pollution nationwide, even in areas lacking monitoring data. Copyright © 2016 Elsevier Ltd. All rights reserved.

Particulate Matter/analysis↗

Real Time Nitrogen Monitoring and Quality Control System for NASA Astromaterials Collection

The Nitrogen system is a vital utility supporting the curation office within NASA's Astromaterials Re-search and Exploration Science (ARES) Division at the Johnson Space center (JSC). Since the Apollo samples were returned in 1969. It has played an essential role in preserving NASA’s astromaterial collections (now nine collections) by maintaining contamination-free, controlled environments required for long term curation and advanced scientific research. To meet the stringent purity requirements for contamination control, high purity modified Grade C Liquid Nitrogen (LN2) is delivered weekly by an industrial gas vendor to a 15,000-gallon tank located outside at NASA JSC near the ARES facility. This nitrogen is vital for creating an inert atmosphere to store the collection in, ensuring they are continuously shielded from contaminants and alterations through a constant N2purge. For most of the past 65 years deliveries of LN2 have required a CoA (Certificate of Analysis) prior to delivery. If those were not available, then LN2 deliver were sent to third-party laboratories for verification, creating an operational bottleneck and quality gap. To address this challenge and maintain rigorous quality control, NASA JSC Infrastructure and Astromaterials Acquisition & Curation Office initiated the development of an on-site Analytical Gas Sampling (AGS) Laboratory. Designed to streamline quality verification if a CoA unavailable, the AGS lab was constructed by a subcontractor in Newton, NJ. After a successful factory acceptance test conducted by the NASA ARES Infrastructure team, the lab was trans-ported to NASA JSC, where it was anchored and integrated into the site’s nitrogen pressure system using stainless steel, oxygen-cleaned tubing. The ARES nitrogen system was modified to provide parallel flows to the AGS lab for quality control and to the astromaterials collection labs for maintaining an inert environment. The AGS lab features two operational modes: (1)Primary: Gaseous Nitrogen (GN2) Quality Monitoring –The AGS system continuously samples the site’s GN2 supply every 15 minutes to ensure compliance with required purity levels. (2) Secondary: LN2 Quality Verification when a comprehensive CoA is not available, a cryogenic vaporizer converts LN2 to GN2, which is then analyzed for impurities: H₂, Ar, O₂, CO, CO₂, H₂O, and total hydrocarbons (THC). By significantly enhancing on-site analytical capabilities, the AGS lab eliminates reliance on external testing, ensures uninterrupted quality monitoring of the nitrogen pressure system, and reinforces NASA’s commitment to preserving pristine astromaterials under the highest standards of curation and research integrity.

glove box↗

Automated Hybridization of X-ray Absorber Elements-A Path to Large Format Microcalorimeter Arrays

In the design of microcalorimeters, it is often desirable to produce the X-ray absorber separately from the detector element. In this case, the attachment of the absorber to the detector element with the required thermal and mechanical characteristics is a major challenge. In such arrays, the attachment has been done by hand. This process is not easily extended to the large format arrays required for future X- ray astronomy missions such as the New x-ray Telescope or NeXT. In this paper we present an automated process for attaching absorber tiles to the surface of a large-scale X-ray detector array. The absorbers are attached with stycast epoxy to a thermally isolating polymer structure made of SU-8. SU-8 is a negative epoxy based photo resist produced by Microchem. We describe the fabrication of the X-ray absorbers and their suspension on a handle die in an adhesive matrix. We describe the production process for the polymer isolators on the detector elements. We have developed a new process for the alignment, and simultaneous bonding of the absorber tiles to an entire detector array. This process uses equipment and techniques used in the flip-chip bonding industry and approaches developed in the fabrication of the XRS-2 instrument. XRS-2 was an X-ray spectrometer that was launched on the Suzaku telescope in July 10, 2005. We describe the process and show examples of sample arrays produced by this process. Arrays with up to 300 elements have been bonded. The present tests have used dummy absorbers made of Si. In future work, we will demonstrate bonding of HgTe absorbers.

Moseley, S.↗

Simple Check Valves for Microfluidic Devices

A simple design concept for check valves has been adopted for microfluidic devices that consist mostly of (1) deformable fluorocarbon polymer membranes sandwiched between (2) borosilicate float glass wafers into which channels, valve seats, and holes have been etched. The first microfluidic devices in which these check valves are intended to be used are micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. In this application, it will be necessary to store some liquid samples in reservoirs in the devices for subsequent laboratory analysis, and check valves are needed to prevent cross-contamination of the samples. The simple check-valve design concept is also applicable to other microfluidic devices and to fluidic devices in general. These check valves are simplified microscopic versions of conventional rubber- flap check valves that are parts of numerous industrial and consumer products. These check valves are fabricated, not as separate components, but as integral parts of microfluidic devices. A check valve according to this concept consists of suitably shaped portions of a deformable membrane and the two glass wafers between which the membrane is sandwiched (see figure). The valve flap is formed by making an approximately semicircular cut in the membrane. The flap is centered over a hole in the lower glass wafer, through which hole the liquid in question is intended to flow upward into a wider hole, channel, or reservoir in the upper glass wafer. The radius of the cut exceeds the radius of the hole by an amount large enough to prevent settling of the flap into the hole. As in a conventional rubber-flap check valve, back pressure in the liquid pushes the flap against the valve seat (in this case, the valve seat is the adjacent surface of the lower glass wafer), thereby forming a seal that prevents backflow.

Willis, Peter A.↗

Rapid Detection of the Varicella Zoster Virus

1.Technology Description-Researchers discovered that when the Varicella Zoster Virus (VZV) reactivates from latency in the body, the virus is consistently present in saliva before the appearance of skin lesions. A small saliva sample is mixed with a specialized reagent in a test kit. If the virus is present in the saliva sample, the mixture turns a red color. The sensitivity and specificity emanates from an antibody-antigen reaction. This technology is a rapid, non-invasive, point of-of-care testing kit for detecting the virus from a saliva sample. The device is easy to use and can be used in clinics and in remote locations to quickly detect VZV and begin treatment with antiviral drugs. 2.Market Opportunity- RST Bioscience will be the first and only company to market a rapid, same day test kit for the detection of VZV in saliva. The RST detection test kit will have several advantages over existing, competitive technology. The test kit is self contained and laboratory equipment is not required for analysis of the sample. Only a single saliva sample is required to be taken instead of blood or cerebral spinal fluid. The test kit is portable, sterile and disposable after use. RST detection test kits require no electrical power or expensive storage equipment and can be used in remote locations. 3.Market Analysis- According to the CDC, it is estimated that 1 million cases of shingles occur each year in the U.S. with more than half over the age of sixty. There is a high demand for rapid diagnostics by the public. The point-of-care testing (POCT) market is growing faster than other segments of in vitro diagnostics. According to a July 2007 InteLab Corporation industry report the overall market for POCT was forecast to increase from $10.3 billion in 2005 to $18.7 billion by 2011. The market value of this test kit has not been determined. 4.Competition- The VZV vaccine prevents 50% of cases and reduces neuralgia by 66%. The most popular test detects VZV-specific IgM antibody in blood. Other tests include running a sample in a polymerase chain reaction analyzer, enzyme immunoassay, latex agglutination, indirect fluorescent antibody and fluorescent antibody to membrane antigen assay. These existing tests require laboratory analysis by trained personnel, expensive equipment, invasive procedures and a longer period of time to obtain test results.

Lewis, Michelle P.↗

Industrial plastics waste: Identification and segregation

Throwaway plastic products, mainly packaging, are inundating our landfills and incinerators. Most are ethenic thermoplastics, which can be recycled as new products or fossil-fuels. Lab experiments are described, involving destructive and non-destructive tests for identifying and using plastics. The burn-test, with simple apparatus and familiar samples, is recommended as quick, cheap and effective.

Widener, Edward L.↗