Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Impact loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Datasets for Widespread Residential Space Heating Electrification in Texas

In this experiment, we explore long term patterns in electricity demand driven by the dual effects of full electrification of space heating in Texas (by adoption of electric heat pumps), and climate change. We use a predictive model of electricity demand, climate projections, and an open source nodal power system (DC Optimal Power Flow) model of the Electric Reliability Council of Texas (ERCOT) system. Heat pumps are a more energy efficient way of providing space heating and cooling in homes. We attempt to exhaustively investigate the impacts of full residential space heating electrification by adoption of heat pumps for the segment of Texas households that currently rely on fossil fuels (about 40%), while simultaneously incorporating climate change meteorological variables. We explore a range of scenarios of heat pump efficiency and climate uncertainty over a long period of future years (2020-2099). In total, the simulation experiment generates 1,280 simulation years of hourly data. We report and analyze results in form of impacts on residential load, total load, peak load, seasonality of peaking, and reliability measured by occurrence and frequency of loss of load events. While the experiment is for ERCOT, the insights and approach can be applied to other regions. The results from the analysis can inform system planners on a range of potential capacity requirements/ reliability implications and/or risks of full space heating electrification via the adoption of electric heat pumps, given the uncertainty in the scenarios/ climate futures. The dataset includes model output for residential, non residential and total load, and the results from the GO ERCOT model runs for 4 RCP Scenarios (RCP 4.5 Cooler, RCP 4.5 Hotter, RCP 8.5 Cooler, RCP 8.5 Hotter), 4 Heating electrification Scenarios (Base , Standard Efficiency HP, High Efficiency HP, Ultra-High Efficiency HP) over 80 years (2020-2099). The metrological variables at BA scale were weighted weighted using population projections consistent with the SSP3 scenario.

Climate Change↗

Charging Infrastructure Technologies: Development of a Multiport, >1 MW Charging System for Medium- and Heavy-Duty Electric Vehicles

Development of a Multiport, >1 MW Charging System for Medium- and Heavy-Duty Electric Vehicles project will develop research tools for a framework to design, optimize, and demonstrate key components of a multi-port 1+ MW medium-voltage connected charging system. The objectives of this effort are to develop strategies and technologies for multi-port 1+ MW grid-connected stations to recharge MD/HD electric vehicles at fast-charging travel plazas or at fleet depots; through industry engagement, charging station utilization and load analysis, grid impacts and interconnection analysis, detailed power electronics component design and controller demonstration, site and battery charge control design and controller demonstration; and charging connector design.

1+MW charging↗

Seismic isolation: A pathway to standardized advanced nuclear reactors

Standardizing advanced nuclear reactors is a pathway to substantially reducing their overnight capital cost and achieving parity with other power sources, including renewables and fossil fuels. The seismic load case has thwarted standardization of nuclear power plants because site-specific seismic hazard and local near-surface geology has triggered soil-structure-interaction analysis, design, equipment qualification, regulatory review, and licensing, ensuring that each build is different. To achieve standardized or site-independent certified advanced reactor designs, the impact of the seismic load case on the engineering and construction cost and time must be substantially mitigated. Seismic isolation is a mature technology that has been used for more than 30 years in non-nuclear sectors to substantially reduce earthquake demands in buildings and other infrastructure. In this paper, seismic isolation is used to enable standardization of advanced reactor designs, aimed at the complete re-use of a site-independent, certified design and repeated procurement of safety-class equipment. A pathway to standardized designs using seismic isolation is demonstrated for two fundamentally different advanced reactors: a molten salt reactor and a high temperature gas reactor. Each reactor building is equipped with three specialized pieces of safety-class equipment, namely, a reactor vessel, a steam generator, and a control rod drive mechanism housing that is attached to the reactor head. Analysis is performed per ASCE and ASME standards to design the buildings and the equipment for two base conditions: conventional (fixed base) and base isolated. The impact of the seismic load case is characterized for the reinforced concrete walls in the buildings and for the equipment, measured using vessel wall thickness and horizontal accelerations. Here the analysis results show that the fixed-base buildings, designed for a site of low seismic hazard (peak ground acceleration, PGA = 0.15 g) could be constructed at a site of much greater seismic hazard (PGA = 0.7 g) if seismic base isolation is employed. Importantly, the scope of the site-specific analysis, design, and qualification would be limited to the seismic isolators and the isolated substructure, drastically reducing plant-specific engineering, review, and licensing, and time to construction start. Regulatory challenges and opportunities with standardized reactor designs are identified.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of 304L stainless steel deformation and failure under cyclic loading

The motivation for this work came from the simulation of components subjected to impact. In these problems, repeated loading can be generated by vibrational motion between internal parts of the component or by the occurrence of multiple impacts. Graphs of tensile equivalent plastic strain $(\overline{\varepsilon}_T^\rho)$ versus time from such cases had the character shown in Fig. 1. The equivalent plastic strain grew by alternating periods of accumulation and hold. The periods of hold indicate times when $d\overline{\varepsilon}_T^\rho$ did not accumulate. This can be due to the material unloading into the elastic range, or actually plastically reverse loading with hydrostatic stress σ h < 0 as was demonstrated for an impact simulation. Similar observations were made from the simulation of a 2-degree-of-freedom mass-elastic-plastic-spring system subjected to impact.

36 MATERIALS SCIENCE↗

Impact of power flow on Z-pinch loads

Magnetically insulated transmission lines (MITLs) are used to deliver tens of MA to a Z-pinch load. The MITLs suffer current losses due to contaminant plasma located in the anode–cathode gap which is swept toward the load along the power flow. The swept up contaminant plasma can deposit mass and energy onto the load resulting in deformations or the seeding of macroscopic instabilities. This paper discusses 2D fully kinetic simulations of the contaminant plasma evolution which predict the current losses and the flux of mass and energy onto the load. Furthermore, the effects of a dynamic, i.e., imploding, load are shown to increase both the current loss and the mass and energy flux. The MITL used is a conical, radially converging design which is a feature common to MA-scale Z-pinch accelerators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

U.S. Distribution Transformer Demand Phase III - Key Drivers and Managing Demand [Slides]

This presentation demonstrates a significant analysis, on forecasting the demand for distribution transformers. The analysis is conducted for the United States, estimating the initial in-service capacity of these assets, and forecasting demand for these assets through 2050 with several sensitivities conducted. It examines not only demand for these assets, but importantly, how utility planning practices can impact the demand for theses assets in time. Under load growth scenarios, whether utilities practice like-for-like replacement strategies as failures occur, or whether they practice proactive up-sizing, anticipating electric load growth, can have major impacts on future demand. It also examines several other growth factors, such as the increasing demand for step-up transformers, which share many of the same characteristics as distribution transformers, and the demand for specific transformers for large project growth from data centers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinated Modeling of Electric Grid and Natural Gas Network Operations

Presentation based upon full report of a Colorado case study and coordination framework, which is available at https://www.nrel.gov/docs/fy20osti/77096.pdf. JISEA analysts Brian Sergi, Omar Guerra, and Bri-Mathias Hodge will present on recent JISEA work on coordination between the natural gas and electricity sectors. Power and gas are becoming increasingly interdependent but weren't designed to function together. How does greater coordination impact system operations with different levels of solar and wind penetrations? This free JISEA presentation will take place in a Webinar on Tuesday, May 11, 2021 at 12 p.m.: Learn how greater coordination between the natural gas and electricity sectors impacts system operations with different levels of solar and wind penetrations. Presentation information includes: Historical and projected data for natural gas consumption and power generation in the United States as demonstrated by 2014 East Coast Polar Vortex, 2021 Texas Winter Storm Uri. Showing coupling points, FERC identified need for better coordination, different levels of coordination (decision making and optimization control), coordination framework. Case study on Colorado Front Range, ramping requirements and gas nominations, real-time dispatch (June and December scenarios), results of analysis of impacts of coordination on unserved load. Total real-time gas offtakes by node, impacts on unserved gas, effect on CO2 emissions. Discussions on clusions drawn from Colorado Case study expanded co-simulation via HELICS, objectives of the HELICS+ natural gas use case, modeling of hydrogen blending, techno economic assessment of blending, and blending impacts on energy content and pressure.

analysis↗

Storage Requirements for Grid Integration of Marine Renewable Energy - a Parametric Study

Marine resources such as waves and tides house immense potential to serve as energy-rich sources of renewable power generation. They are known to be highly available,persistent and predictable in nature. Therefore, these can serve as one of the critical components for a primarily renewable energy-driven, resilient and robust future power grid. Although some inherent temporal characteristics of these resources lend themselves favorably to potential grid applications, the inclusion of storage allows the benefits and value streams to become realized more fully. In this paper, we present a framework for assessing impact of marine energy resources inclusion on the overall load generation balance and its impact on the relevant storage requirements to obtain the desired level of renewable energy penetration. From this study, we can critically infer two main points - (a) the relative storage requirements for grid operations with and without marine energy, and (b) the avoided cost of storage by including marine energy into the generation mix. We demonstrate our framework for two different locations across the United States.

Hanif, Sarmad↗

New vortex‐lift and tangential‐force models for HAWT aerodynamic load prediction

Abstract Horizontal axis wind turbines (HAWTs) experience three‐dimensional rotational and unsteady aerodynamic phenomena at the rotor blades sections. These highly unsteady three‐dimensional effects have a dramatic impact on the aerodynamic load distributions on the blades, in particular, when they occur at high angles of attack due to stall delay and dynamic stall. Unfortunately, there is no complete understanding of the flow physics yet at these unsteady 3D flow conditions, and hence, the existing published theoretical models are often incapable of modelling the impact on the turbine response realistically. The purpose of this paper is to provide an insight on the combined influence of the stall delay and dynamic stall on the blade load history of wind turbines in controlled and uncontrolled conditions. New dynamic stall vortex and nonlinear tangential force coefficient modules, which integrally take into account the three dimensional rotational effect, are also proposed in this paper. This module along with the unsteady influence of turbulent wind speed and tower shadow is implemented in a blade element momentum (BEM) model to estimate the aerodynamic loads on a rotating blade more accurately. This work presents an important step to help modelling the combined influence of the stall delay and dynamic stall on the load history of the rotating wind turbine blades which is vital to have lighter turbine blades and improved wind turbine design systems.

Elgammi, Moutaz↗

Sensitivity analysis of the effect of wind and wake characteristics on wind turbine loads in a small wind farm

Abstract. Wind turbines are designed using a set of simulations to determine the fatigue and ultimate loads, which are typically focused solely on unwaked wind turbine operation. These structural loads can be significantly influenced by the wind inflow conditions. Turbines experience altered inflow conditions when placed in the wake of upstream turbines, which can additionally influence the fatigue and ultimate loads. It is important to understand the impact of uncertainty on the resulting loads of both unwaked and waked turbines. The goal of this work is to assess which wind-inflow-related and wake-related parameters have the greatest influence on fatigue and ultimate loads during normal operation for turbines in a three-turbine wind farm. Twenty-eight wind inflow and wake parameters are screened using an elementary effects sensitivity analysis approach to identify the parameters that lead to the largest variation in the fatigue and ultimate loads of each turbine. This study uses the National Renewable Energy Laboratory (NREL) 5 MW baseline wind turbine, simulated with OpenFAST and synthetically generated inflow based on the International Electrotechnical Commission (IEC) Kaimal turbulence spectrum with the IEC exponential coherence model using the NREL tool TurbSim. The focus is on sensitivity to individual parameters, though interactions between parameters are considered, and how sensitivity differs between waked and unwaked turbines. The results of this work show that for both waked and unwaked turbines, ambient turbulence in the primary wind direction and shear are the most sensitive parameters for turbine fatigue and ultimate loads. Secondary parameters of importance for all turbines are identified as yaw misalignment, streamwise integral length, and the exponent and streamwise components of the IEC coherence model. The tertiary parameters of importance differ between waked and unwaked turbines. Tertiary effects account for up to 9.0 % of the significant events for waked turbine ultimate loads and include veer, non-streamwise components of the IEC coherence model, Reynolds stresses, wind direction, air density, and several wake calibration parameters. For fatigue loads, tertiary effects account for up to 5.4 % of the significant events and include vertical turbulence standard deviation, lateral and vertical wind integral lengths, non-streamwise components of the IEC coherence model, Reynolds stresses, wind direction, and all wake calibration parameters. This information shows the increased importance of non-streamwise wind components and wake parameters in the fatigue and ultimate load sensitivity of downstream turbines.

17 WIND ENERGY↗

Maximizing the Benefits of On-Site Renewable Energy Generation Using On-Site Energy Storage

The commercial and industrial building sectors have a major role to play in a U.S. low-carbon future. Building owners can make a difference by deploying on-site renewable generation and storage technologies, which facilitates future-proofing their buildings as well as more effectively meeting the service requirements of the building. This resource provides an overview of common generation, storage, and load management technologies in behind-the-meter systems, and serves as a primer to demonstrate the impact on net building loads required from the grid for different sizes of renewable generation along with on-site electrical and thermal storage. These discussions can help commercial building owners communicate the value of these systems to project teams and develop innovative behind-the-meter solutions to achieve their energy goals.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Graph Neural Networks for Surrogate Modeling of Offshore Floating Platforms

Floating offshore wind turbines (FOWTs) present an significant opportunity to increase renewable energy generation. However, significant challenges remain before FOWTs can be widely commercialized and deployed. In particular, hydrodynamic loading on the platforms can stress the overall structure, damage the mooring systems, and impact power generation. Studying these loads is difficult and often relies on computationally expensive models or experiments. In this work, we explore the use of graph neural networks (GNNs) to construct flexible, data-driven surrogates for hydrodynamic loads on platforms. We leverage the natural graph-like structure of offshore wind platform designs to enable the GNN model to learn to approximate the loads for different wave conditions and structural designs. We demonstrate potential uses for the surrogate by performing parameter sweeps and ridge analysis on the trained model to identify the impacts of different wave and structural features on the loads.

floating offshore wind turbines↗

Sensitivity analysis of numerical modeling input parameters on floating offshore wind turbine loads

Abstract. Floating wind turbines must withstand a unique and challenging set of loads from the wind and ocean environment. To de-risk development, accurate predictions of these loads are necessary. Uncertainty in modeling predictions leads to larger required safety factors, increasing project costs and the levelized cost of energy. Complex aero-hydro-elastic modeling tools use many input parameters to represent the wind, waves, current, aerodynamic loads, hydrodynamic loads, and structural properties. It is helpful to understand which of these parameters ultimately drives a design. In this work, an ultimate and fatigue-proxy load sensitivity analysis was performed with 35 different input parameters, using an elementary effects approach to identify the most influential parameters for a case study involving the National Renewable Energy Laboratory (NREL) 5 MW baseline wind turbine atop the OC4-DeepCwind semisubmersible during normal operation. The importance of each parameter was evaluated using 14 response quantities of interest across three operational wind speed conditions. The study concludes that turbulent wind velocity standard deviation is the parameter with the strongest sensitivity; this value is important not just for turbine loads, but also for the global system response. The system center of mass in the wind direction is found to have the highest impact on the system rotation and tower loads. The current velocity is found to be the most dominating parameter for the system global motion and consequently the mooring loads. All tested wind turbulence parameters in addition to the standard deviation are also found to be influential. Wave characteristics are influential for some fatigue-proxy loading but do not significantly impact the extreme ultimate loads in these operational load cases. The required number of random seeds for stochastic environmental conditions is considered to ensure that the sensitivities are due to the input parameters and not due to the seed. The required number of analysis points in the parameter space is identified so that the conclusions represent a global sensitivity. The results are specific to the platform, turbine, and choice of parameter ranges, but the demonstrated approach can be applied widely to guide focus in parameter uncertainty.

17 WIND ENERGY↗

Modelica-based system modeling for studying control-related faults in chiller plants and boiler plants serving large office buildings

System modeling is critical when studying operation faults in chiller plants and boiler plants. However, current fault models have difficulties faithfully representing the operation of chiller plants and boiler plants under the effects of those faults, especially the control-related ones. In this study, we present a systematic method to develop high-fidelity models for approximating the behaviors of chiller plants and boiler plants under faulty conditions. Compared to existing ones, the resulting fault models have two advantages: first, they better characterize the dynamic patterns in the system operation. In those models, control architecture and control logic are faithfully implemented. Thus, they can be used to study control-related faults, such as incorrect staging control due to sensor bias and mistuned feedback control. Second, they are readily extensible and can support large-scale investigations to explore different faulty conditions/scenarios. Those models are established in a hierarchical structure while modules in each layer can be redeclared and parameterized at upper layers. In such a case, modifications to the models can be realized through model modifiers and the process can be easily streamlined with scripts. We applied the proposed models in a comprehensive fault impact evaluation of the 13 control-related faults of chiller and boiler plants. In this evaluation, the proposed plant model is coupled with the EnergyPlus thermal load model to study the impact of various faulty scenarios. Based on the evaluation results, we identified the faults that have the most significant impacts on the operation of the chiller and boiler plants, respectively. We also found that the relationship between the impacts of the studied faults and the severity level of the faults are highly non-linear

Huang, Sen↗

Field Study of Grid-connected Heat Pump Water Heaters in the Southeast U.S.: The Next Right Thing

The integration of grid-connected functionality and advanced control algorithms into heat pump water heaters (HPWH) offers the capability to shift load with minimal customer impact. This capability provides a flexible grid resource to utilities, while the increased energy efficiency of HPWHs offers customers a lower electric bill. The combined utility/customer value from grid-connected HPWHs is compelling in the Southeast U.S. where residential electric water heating is prevalent and utility load management is common. This paper presents the results of a HPWH load shifting study conducted in Central Florida using the CTA-2045 standard. Building upon previous research in the Pacific Northwest, this study consisted of approximately 45 occupied homes equipped with HPWHs undergoing load shifting strategies weekly for over a year. Curtailment durations ranged from three to five hours in the morning, and four to five hours in the evening to coincide with high-value periods for utility coincident load for system-wide electric demand reductions. During the morning and afternoon, a one- or two-hour load-up event preceded curtailment. Baseline data were collected across varied Florida weather in which no load shifting events were implemented. Results from traditional load shifting strategies were analyzed across seasons and used to devise unique load shifting approaches to increase renewable energy use during periods of high solar energy generation. Regional impacts are forecasted for large-scale implementation of strategies. Lessons learned and recommendations are also provided for how utilities, manufacturers, and regional planners can maximize load shifting benefits from grid-connected HPWHs.

Heat pump water heaters, residential building, loa↗

Occupant Preference-Aware Load Scheduling for Resilient Communities

The load scheduling of resilient communities in the islanded mode is subject to many uncertainties such as weather forecast errors and occupant behavior stochasticity. To date, it remains unclear how occupant preferences affect the effectiveness of the load scheduling of resilient communities. This paper proposes an occupant thermal preference-aware load scheduler for resilient communities operating in the islanded mode. First, key resilience indicators are selected to quantify its impacts on the load scheduling of a resilient community. A deterministic model predictive control-based load scheduling framework is adopted as the baseline. Then, a chance-constrained controller is proposed to address the occupant-induced uncertainty in room temperature setpoints. Finally, the chance-constrained controller is compared with the deterministic controller on a virtual community testbed based on a real-world net-zero energy community in Florida, U.S. Results have shown that the proposed chance-constrained controller performs better in terms of serving occupants’ thermal preference and the required battery sizes compared to the deterministic controller with the presence of the assumed stochastic occupant behavior. This work indicates that it is necessary to consider the stochasticity of the occupant behavior when designing optimal load schedulers for resilient communities.

Wang, Jing↗

Effect of the integral length scales of turbulent inflows on wind turbine loads

As wind turbines become larger, the fluctuations in the inflow become increasingly influential in the turbine structural loading. These fluctuations are characterized by the integral length scale, which represents the average size of the largest energy-containing turbulent eddies. Current design standards neglect the varying integral length scales that characterize inflows of wind turbines in operation. Using large-eddy simulations, we generate turbulent inflows of varying integral length scales and quantify the loads of the IEA 15-MW reference wind turbine. Results illustrate that the impact of turbulence on rotor and tower loads is up to 10 times greater than the impact of the mean shear profile. Increasing integral length scales from 0.3x to 0.5x the rotor diameter reduces blade root flapwise moments and rotor and tower loads. Increasing integral length scales from 0.5x to 1.7x the rotor diameter increases the rotor aerodynamic thrust force and the blade root flapwise shear loads and decreases the tower base torsional moment and the tilting and yawing rotor aerodynamic moments. Additionally, turbulence intensity has a greater impact on wind turbine loads than integral length scales. In conclusion, findings indicate that design standards should consider varying integral length scales for accurate wind turbine loading characterization in turbulent inflow conditions.

17 WIND ENERGY↗

Developing Near Optimal Control Sequences for Chiller Plants with Water-side Economizers: A Case Study in a Warm and Marine Climate

Various advanced control sequences for chiller plants with water-side economizers (WSE) have been proposed in literature, but the optimization of those controls is limited. It is possible to maximize energy savings by developing near-optimal control sequences, which are dependent on several factors such as the load profile. To address these gaps, we first identify an advanced control sequence and three key control parameters for chiller plants with WSE. Next, optimizations are performed to minimize energy consumption for seven combinations of control parameters. A chiller plant with WSE system in a warm and marine climate is studied and two load profiles are considered. The system and controls are modeled using the Modelica Buildings library. The results show optimizing the selected control parameters can reduce energy consumption by up to 11% depending on the load profile. Specifically, optimizing the cooling tower efficiency threshold in the condenser water reset control can significantly reduce energy savings for the variable load profile by efficiently shifting the load from the cooling tower to the chiller. This paper provides practical guidance for developing near-optimal control sequences for chiller plant with WSE systems considering impacts such as the load profile.

chiller plant↗