Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image reconstruction techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

First experimental study of multiple orientation muon tomography, with image optimization in sparse data environments

Due to the high penetrating power of cosmic ray muons, they can be used to probe very thick and dense objects. As charged particles, they can be tracked by ionization detectors, determining the position and direction of the muons. With detectors on either side of an object, particle direction changes can be used to extract scattering information within an object. This can be used to produce a scattering intensity image within the object related to density and atomic number. Such imaging is typically performed with a single detector-object orientation, taking advantage of the more intense downward flux of muons, producing planar imaging with some depth-of-field information in the third dimension. Several simulation studies have been published with multi-orientation tomography, which can form a three-dimensional representation faster than a single orientation view. In this work we present the first experimental multiple orientation muon tomography study. Experimental muon-scatter based tomography was performed using a concrete filled steel drum with several different metal wedges inside, between detector planes. Data was collected from different detector-object orientations by rotating the steel drum. The data collected from each orientation were then combined using two different tomographic methods. Results showed that using a combination of multiple depth-of-field reconstructions, rather than a traditional inverse Radon transform approach used for CT, resulted in more useful images for sparser data. As cosmic ray muon flux imaging is rate limited, the imaging techniques were compared for sparse data. Using the combined depth-of-field reconstruction technique, fewer detector-object orientations were needed to reconstruct images that could be used to differentiate the metal wedge compositions.

Applied Physics (physics.app-ph)↗

Generalized Optimization of High-Capacity Compressive Imaging Systems

One of the greatest challenges in applying compressive sensing (CS) signal processing techniques to electromagnetic imaging applications is designing a sensing matrix that has good reconstruction capabilities. Compressive reflector antennas (CRAs) are a class of antennas that have been shown to provide enhanced image reconstruction performance over traditional reflector antennas (TRAs) when CS techniques are employed. In this article, we present a unified CRA design method, which considers both the sensing capacity and efficiency of the antenna and can be used for both compressive imaging and multiple-input multiple-output (MIMO) communication applications. The unified design method is assessed for a CRA configuration in which dielectric scatterers are added to the surface of a TRA. The design results demonstrate the ability of the unified design method to enhance the CS reconstruction capabilities of the CRA.

42 ENGINEERING↗

Image filtering as an alternative to the application of a different reconstruction kernel in CT imaging: Feasibility study in lung cancer screening

Purpose: While the acquisition of projection data in a computed tomography (CT) scanner is generally carried out once, the projection data is often removed from the system, making further reconstruction with a different reconstruction filter impossible. The reconstruction kernel is one of the most important parameters. To have access to all the reconstructions, either prior reconstructions with multiple kernels must be performed or the projection data must be stored. Each of these requirements would increase the burden on data archiving. This study aimed to design an effective method to achieve similar image quality using an image filtering technique in the image space, instead of a reconstruction filter in the projection space for CT imaging. The authors evaluated the clinical feasibility of the proposed method in lung cancer screening. Methods: The proposed technique is essentially the same as common image filtering, which performs processing in the spatial-frequency domain with a filter function. However, the filter function was determined based on the quantitative analysis of the point spread functions (PSFs) measured in the system. The modulation transfer functions (MTFs) were derived from the PSFs, and the ratio of the MTFs was used as the filter function. Therefore, using an image reconstructed with a kernel, an image reconstructed with a different kernel was obtained by filtering, which used the ratio of the MTFs obtained for the two kernels. The performance of the method was evaluated by using routine clinical images obtained from CT screening for lung cancer in five subjects. Results: Filtered images for all combinations of three types of reconstruction kernels (''smooth,''''standard,'' and ''sharp'' kernels) showed good agreement with original reconstructed images regarded as the gold standard. On the filtered images, abnormal shadows suspected as being lung cancers were identical to those on the reconstructed images. The standard deviations (SDs) for the difference between filtered images and reconstructed images ranged from 1.9 to 23.5 Hounsfield units for all kernel combinations; these SDs were much smaller than the noise SDs in the reconstructed images. Conclusions: The proposed method has good performance and is clinically feasible in lung cancer screening. This method can be applied to images reconstructed on any scanner by measuring the PSFs in each system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional electron temperature measurement of inertial confinement fusion hotspots using x-ray emission tomography

Here we present a novel approach to reconstruct three-dimensional (3D) electron temperature distributions of inertially confined fusion plasma hotspots at the National Ignition Facility. Using very limited number of two-dimensional (2D) x-ray imaging lines of sight, we perform 3D reconstructions of x-ray emission distributions from different x-ray energy channels ranging from 20 to 30 keV. 2D time-integrated x-ray images are processed using the algebraic reconstruction technique to reconstruct a 3D hotspot x-ray emission distribution that is self-consistent with the input images. 3D electron temperatures are computed using the energy channel ratios. We demonstrate the high accuracy and applicability of this method with different complex hotspot geometries in both synthetic and experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lensless Particle Image Velocimetry

The application of lensless imaging to particle image velocimetry (PIV) is demonstrated. Lensless PIV eliminates the need for imaging lenses to measure flow fields near a surface. Only the camera sensor, a thin mask, and computations are required to image particles in a flow field and to compute the velocity field. The small form factor could enable embedded sensors for near-wall measurements. Flow field measurements are obtained simultaneously for a lensless system and lens-based 2D PIV system, and several different reconstruction techniques are demonstrated. The reconstructed particle images and computed velocity fields compare well for both a uniform and shear flow. The potential for stereo and 3D volumetric PIV with a single camera sensor is demonstrated through different image reconstruction approaches.

Lensless imaging↗

Progress toward the development and testing of source reconstruction methods for NIF neutron imaging

Development of analysis techniques for neutron imaging at the National Ignition Facility is an important and difficult task for the detailed understanding of high-neutron yield inertial confinement fusion implosions. Once developed, these methods must provide accurate images of the hot and cold fuels so that information about the implosion, such as symmetry and areal density, can be extracted. One method under development involves the numerical inversion of the pinhole image using knowledge of neutron transport through the pinhole aperture from Monte Carlo simulations. In this article we present results of source reconstructions based on simulated images that test the methods effectiveness with regard to pinhole misalignment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-F-17A-04: Respiratory Phase-Resolved 3D MRI with Isotropic High Spatial Resolution: Determination of the Average Breathing Motion Pattern for Abdominal Radiotherapy Planning

Purpose: To develop a retrospective 4D-MRI technique (respiratory phase-resolved 3D-MRI) for providing an accurate assessment of tumor motion secondary to respiration. Methods: A 3D projection reconstruction (PR) sequence with self-gating (SG) was developed for 4D-MRI on a 3.0T MRI scanner. The respiration-induced shift of the imaging target was recorded by SG signals acquired in the superior-inferior direction every 15 radial projections (i.e. temporal resolution 98 ms). A total of 73000 radial projections obtained in 8-min were retrospectively sorted into 10 time-domain evenly distributed respiratory phases based on the SG information. Ten 3D image sets were then reconstructed offline. The technique was validated on a motion phantom (gadolinium-doped water-filled box, frequency of 10 and 18 cycles/min) and humans (4 healthy and 2 patients with liver tumors). Imaging protocol included 8-min 4D-MRI followed by 1-min 2D-realtime (498 ms/frame) MRI as a reference. Results: The multiphase 3D image sets with isotropic high spatial resolution (1.56 mm) permits flexible image reformatting and visualization. No intra-phase motion-induced blurring was observed. Comparing to 2D-realtime, 4D-MRI yielded similar motion range (phantom: 10.46 vs. 11.27 mm; healthy subject: 25.20 vs. 17.9 mm; patient: 11.38 vs. 9.30 mm), reasonable displacement difference averaged over the 10 phases (0.74mm; 3.63mm; 1.65mm), and excellent cross-correlation (0.98; 0.96; 0.94) between the two displacement series. Conclusion: Our preliminary study has demonstrated that the 4D-MRI technique can provide high-quality respiratory phase-resolved 3D images that feature: a) isotropic high spatial resolution, b) a fixed scan time of 8 minutes, c) an accurate estimate of average motion pattern, and d) minimal intra-phase motion artifact. This approach has the potential to become a viable alternative solution to assess the impact of breathing on tumor motion and determine appropriate treatment margins. Comparison with 4D-CT in a clinical setting is warranted to assess the value of 4D-MRI in radiotherapy planning. This work supported in part by grant 1R03CA173273-01.

60 APPLIED LIFE SCIENCES↗

Ultrasound guided fluorescence molecular tomography with improved quantification by an attenuation compensated born-normalization and in vivo preclinical study of cancer

Ultrasound imaging, having the advantages of low-cost and non-invasiveness over MRI and X-ray CT, was reported by several studies as an adequate complement to fluorescence molecular tomography with the perspective of improving localization and quantification of fluorescent molecular targets in vivo. Based on the previous work, an improved dual-modality Fluorescence-Ultrasound imaging system was developed and then validated in imaging study with preclinical tumor model. Ultrasound imaging and a profilometer were used to obtain the anatomical prior information and 3D surface, separately, to precisely extract the tissue boundary on both sides of sample in order to achieve improved fluorescence reconstruction. Furthermore, a pattern-based fluorescence reconstruction on the detection side was incorporated to enable dimensional reduction of the dataset while keeping the useful information for reconstruction. Due to its putative role in the current imaging geometry and the chosen reconstruction technique, we developed an attenuation compensated Born-normalization method to reduce the attenuation effects and cancel off experimental factors when collecting quantitative fluorescence datasets over large area. Results of both simulation and phantom study demonstrated that fluorescent targets could be recovered accurately and quantitatively using this reconstruction mechanism. Finally, in vivo experiment confirms that the imaging system associated with the proposed image reconstruction approach was able to extract both functional and anatomical information, thereby improving quantification and localization of molecular targets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Super Resolving Unrolled Neural Networks for Remote Sensing

In remote sensing systems, the capabilities of the system are constrained by the complex interactions between size, weight, and power (SWAP) of potential designs. In electro-optical (EO) systems, examples of these critical parameters include the system’s sensitivity and resolution. Those parameters can be increased by ever larger optical apertures and focal planes but at the cost of more SWAP. Multi-image super resolution (MISR) techniques allow resolution to be enhanced via computation rather than more sophisticated optical hardware. These algorithms combine multiple images together into a single, higher resolution image, trading temporal resolution and computation for spatial resolution. Fielded MISR techniques, such as Drizzle, can require several hundred images to create a single super resolved image, implying reduced temporal resolution, increased data acquisition load, and limiting mission applications. Iterative techniques, such as model-based image reconstruction and compressive sensing, have been shown to create super resolved images using fewer images than Drizzle. They do this by posing an optimization problem that balances accuracy between a highly accurate physical model and an image model. In the case of super resolution, the physical model is defined by the relation between low resolution input images and the desired high resolution output image. The image model encodes some assumptions about the super resolved image. These assumptions are meant to suppress reconstruction artifacts that arise due to deterministic physical model error, stochastic measurement noise, and potential undersampling. In practice, the performance of iterative methods are limited by imaging models compatible with optimization. Deep learning-based methods can effectively learn image models of arbitrary complexity, but lack the theoretical explainability and robustness of iterative techniques. Consensus equilibrium (CE) generalizes the iterative techniques beyond optimization, enabling blackbox algorithms such as traditional and neural image denoisers to be used as the image model. CE-based approaches retain much of the explainability and robustness of iterative techniques while allowing the expressiveness of machine learning image models to be used. Additionally, by unrolling iterations of CE with an embedded image denoiser, the image denoiser can be further trained and specialized to the specific application with potentially higher quality reconstructions. Under this project, we demonstrated the feasibility of training an unrolled neural network based upon CE. While we didn’t train one, we showed that the CE process is differentiable and its gradient can be tractably computed. We also explored the usage of a variants of CE akin to generative neural works. Most importantly, we applied the CE framework to a number of problems including non-blind deconvolution, upsampling, single-image super resolution, MISR, event-based sensing, and saturated deconvolution. Our MISR prototype creates high quality reconstructions with an order of magnitude fewer images than previous approaches and, critically, produces these reconstructions fast enough for practical usage.

47 OTHER INSTRUMENTATION↗

Contour interpolated radial basis functions with spline boundary correction for fast 3D reconstruction of the human articular cartilage from MR images

Purpose: The aim of this work is to demonstrate a new image processing technique that can provide a “near real-time” 3D reconstruction of the articular cartilage of the human knee from MR images which is user friendly. This would serve as a point-of-care 3D visualization tool which would benefit a consultant radiologist in the visualization of the human articular cartilage. Methods: The authors introduce a novel fusion of an adaptation of the contour method known as “contour interpolation (CI)” with radial basis functions (RBFs) which they describe as “CI-RBFs.” The authors also present a spline boundary correction which further enhances volume estimation of the method. A subject cohort consisting of 17 right nonpathological knees (ten female and seven male) is assessed to validate the quality of the proposed method. The authors demonstrate how the CI-RBF method dramatically reduces the number of data points required for fitting an implicit surface to the entire cartilage, thus, significantly improving the speed of reconstruction over the comparable RBF reconstruction method of Carr. The authors compare the CI-RBF method volume estimation to a typical commercial package (3D DOCTOR), Carr’s RBF method, and a benchmark manual method for the reconstruction of the femoral, tibial, and patellar cartilages. Results: The authors demonstrate how the CI-RBF method significantly reduces the number of data points (p-value < 0.0001) required for fitting an implicit surface to the cartilage, by 48%, 31%, and 44% for the patellar, tibial, and femoral cartilages, respectively. Thus, significantly improving the speed of reconstruction (p-value < 0.0001) by 39%, 40%, and 44% for the patellar, tibial, and femoral cartilages over the comparable RBF model of Carr providing a near real-time reconstruction of 6.49, 8.88, and 9.43 min for the patellar, tibial, and femoral cartilages, respectively. In addition, it is demonstrated how the CI-RBF method matches the volume estimation of a typical commercial package (3D DOCTOR), Carr’s RBF method, and a benchmark manual method for the reconstruction of the femoral, tibial, and patellar cartilages. Furthermore, the performance of the segmentation method used for the extraction of the femoral, tibial, and patellar cartilages is assessed with a Dice similarity coefficient, sensitivity, and specificity measure providing high agreement to manual segmentation. Conclusions: The CI-RBF method provides a fast, accurate, and robust 3D model reconstruction that matches Carr’s RBF method, 3D DOCTOR, and a manual benchmark method in accuracy and significantly improves upon Carr’s RBF method in data requirement and computational speed. In addition, the visualization tool has been designed to quickly segment MR images requiring only four mouse clicks per MR image slice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving Limited Angle CT Reconstruction with a Robust GAN Prior

Limited angle CT reconstruction is an under-determined linear inverse problem that requires appropriate regularization techniques to be solved. In this work we study how pre-trained generative adversarial networks (GANs) can be used to clean noisy, highly artifact laden reconstructions from conventional techniques, by effectively projecting onto the inferred image manifold. In particular, we use a robust version of the popularly used GAN prior for inverse problems, based on a recent technique called corruption mimicking, that significantly improves the reconstruction quality. The proposed approach operates in the image space directly, as a result of which it does not need to be trained or require access to the measurement model, is scanner agnostic, and can work over a wide range of sensing scenarios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-D-9A-01: Listmode-Driven Optimal Gating (OG) Respiratory Motion Management: Potential Impact On Quantitative PET Imaging

Purpose: To evaluate the potential impact of listmode-driven amplitude based optimal gating (OG) respiratory motion management technique on quantitative PET imaging. Methods: During the PET acquisitions, an optical camera tracked and recorded the motion of a tool placed on top of patients' torso. PET event data were utilized to detect and derive a motion signal that is directly coupled with a specific internal organ. A radioactivity-trace was generated from listmode data by accumulating all prompt counts in temporal bins matching the sampling rate of the external tracking device. Decay correction for 18F was performed. The image reconstructions using OG respiratory motion management technique that uses 35% of total radioactivity counts within limited motion amplitudes were performed with external motion and radioactivity traces separately with ordered subset expectation maximization (OSEM) with 2 iterations and 21 subsets. Standard uptake values (SUVs) in a tumor region were calculated to measure the effect of using radioactivity trace for motion compensation. Motion-blurred 3D static PET image was also reconstructed with all counts and the SUVs derived from OG images were compared with SUVs from 3D images. Results: A 5.7 % increase of the maximum SUV in the lesion was found for optimal gating image reconstruction with radioactivity trace when compared to a static 3D image. The mean and maximum SUVs on the image that was reconstructed with radioactivity trace were found comparable (0.4 % and 4.5 % increase, respectively) to the values derived from the image that was reconstructed with external trace. Conclusion: The image reconstructed using radioactivity trace showed that the blurring due to the motion was reduced with impact on derived SUVs. The resolution and contrast of the images reconstructed with radioactivity trace were comparable to the resolution and contrast of the images reconstructed with external respiratory traces. Research supported by Siemens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Iterative reconstruction techniques for industrial CT: application and performance

BWXT Y-12, Oak Ridge National Laboratory, and the University of Tennessee have been working toward improved high-resolution X-ray computed tomography for non-destructive testing of manufactured objects. The emphasis of this work has been on iterative reconstruction, calibration, and performance testing. Algebraic reconstruction algorithms for CT have been developed that are more robust in handling incomplete and noisy data and permit high-resolution volumetric imaging on metallic part assemblies. A key source of artifacts in reconstructed CT images for industrial components is poor image statistics due to areas of high attenuation. This loss of information in the captured projections not only affects reconstruction of those areas, but also the surrounding regions. To overcome numerical instabilities arising from the ill-posed nature of inverse problems, standard regularization techniques can be applied as can Bayesian reconstruction techniques using prior data such as CAD information to improve image quality. To accelerate the reconstruction of certain regions of interest and reduce memory requirements, subvolume reconstruction has been implemented and tested. A computational framework has been implemented that facilitates the use of sophisticated iterative algorithms for reconstruction of three-dimensional images from high-resolution X-ray cone-beam projection data. The code supports parallel computing at two levels: message passing is used to farm the computation out across a network of computers while threads allow all processors available on any one computer to be used.

99 GENERAL AND MISCELLANEOUS↗

Machine-Vision Aids for Improved Flight Operations

The development of machine vision based pilot aids to help reduce night approach and landing accidents is explored. The techniques developed are motivated by the desire to use the available information sources for navigation such as the airport lighting layout, attitude sensors and Global Positioning System to derive more precise aircraft position and orientation information. The fact that airport lighting geometry is known and that images of airport lighting can be acquired by the camera, has lead to the synthesis of machine vision based algorithms for runway relative aircraft position and orientation estimation. The main contribution of this research is the synthesis of seven navigation algorithms based on two broad families of solutions. The first family of solution methods consists of techniques that reconstruct the airport lighting layout from the camera image and then estimate the aircraft position components by comparing the reconstructed lighting layout geometry with the known model of the airport lighting layout geometry. The second family of methods comprises techniques that synthesize the image of the airport lighting layout using a camera model and estimate the aircraft position and orientation by comparing this image with the actual image of the airport lighting acquired by the camera. Algorithms 1 through 4 belong to the first family of solutions while Algorithms 5 through 7 belong to the second family of solutions. Algorithms 1 and 2 are parameter optimization methods, Algorithms 3 and 4 are feature correspondence methods and Algorithms 5 through 7 are Kalman filter centered algorithms. Results of computer simulation are presented to demonstrate the performance of all the seven algorithms developed.

Menon, P. K.↗

Visualization of Subsurface Defects in Composites using a Focal Plane Array Infrared Camera

A technique for enhanced defect visualization in composites via transient thermography is presented in this paper. The effort targets automated defect map construction for multiple defects located in the observed area. Experimental data were collected on composite panels of different thickness with square inclusions and flat bottom holes of different depth and orientation. The time evolution of the thermal response and spatial thermal profiles are analyzed. The pattern generated by carbon fibers and the vignetting effect of the focal plane array camera make defect visualization difficult. An improvement of the defect visibility is made by the pulse phase technique and the spatial background treatment. The relationship between a size of a defect and its reconstructed image is analyzed as well. The image processing technique for noise reduction is discussed.

Plotnikov, Yuri A.↗

Combined multi-analytical approach for study of pore system in bricks: How much porosity is there?

During the firing of bricks, mineralogical and textural transformations produce an artificial aggregate characterised by significant porosity. Particularly as regards pore-size distribution and the interconnection model, porosity is an important parameter to evaluate and predict the durability of bricks. The pore system is in fact the main element, which correlates building materials and their environment (especially in cases of aggressive weathering, e.g., salt crystallisation and freeze-thaw cycles) and determines their durability. Four industrial bricks with differing compositions and firing temperatures were analysed with “direct” and “indirect” techniques, traditional methods (mercury intrusion porosimetry, hydric tests, nitrogen adsorption) and new analytical approaches based on digital image reconstruction of 2D and 3D models (back-scattered electrons and computerised X-ray micro-Tomography, respectively). The comparison of results from different analytical methods in the “overlapping ranges” of porosity and the careful reconstruction of a cumulative curve, allowed overcoming their specific limitations and achieving better knowledge on the pore system of bricks. - Highlights: •Pore-size distribution and structure of the pore system in four commercial bricks •A multi-analytical approach combining “direct” and “indirect” techniques •Traditional methods vs. new approaches based on 2D/3D digital image reconstruction •The use of “overlapping ranges” to overcome the limitations of various techniques.

36 MATERIALS SCIENCE↗

MemXCT: Design, Optimization, Scaling, and Reproducibility of X-Ray Tomography Imaging

Here, this work extends our previous research entitled "MemXCT: Memory-centric X-ray CT Reconstruction with Massive Parallelization" that was originally published at SC19 conference (Hidayetoglu et al., 2019) with reproducibility of the computational imaging performance. X-ray computed tomography (XCT) is regularly used at synchrotron light sources to study the internal morphology of materials at high resolution. However, experimental constraints, such as radiation sensitivity, can result in noisy or undersampled measurements. Further, depending on the resolution, sample size and data acquisition rates, the resulting noisy dataset can be in the order of terabytes. Advanced iterative reconstruction techniques can produce high-quality images from noisy measurements, but their computational requirements have made their use an exception rather than the rule. We propose a novel memory-centric approach that avoids redundant computations at the expense of additional memory complexity. We develop a memory-centric iterative reconstruction system, MemXCT, that uses an optimized SpMV implementation with two-level pseudo-Hilbert ordering and multi-stage input buffering. We evaluate MemXCT on various supercomputer architectures involving KNL and GPU. MemXCT can reconstruct a large (11Kx11K) mouse brain tomogram in 10 seconds using 4096 KNL nodes (256K cores). The results presented in our original article at the SC19 were based on large-scale supercomputing resources. The MemXCT application was selected for the Student Cluster Competition (SCC) Reproducibility Challenge and evaluated on a variety of cloud computing resources by universities around the world in the SC20 conference. We summarize the results of the top-ranked SCC Reproducibility Challenge teams and identify the most pertinent measures for ensuring the reproducibility of our experiments in this article.

47 OTHER INSTRUMENTATION↗

The Pixon Method for Data Compression Image Classification, and Image Reconstruction

As initially proposed, this program had three goals: (1) continue to develop the highly successful Pixon method for image reconstruction and support other scientist in implementing this technique for their applications; (2) develop image compression techniques based on the Pixon method; and (3) develop artificial intelligence algorithms for image classification based on the Pixon approach for simplifying neural networks. Subsequent to proposal review the scope of the program was greatly reduced and it was decided to investigate the ability of the Pixon method to provide superior restorations of images compressed with standard image compression schemes, specifically JPEG-compressed images.

Puetter, Richard↗