Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Reducing the Requirements and Cost of Astronomical Telescopes

Limits on astronomical telescope apertures are being rapidly approached. These limits result from logistics, increasing complexity, and finally budgetary constraints. In an historical perspective, great strides have been made in the area of aperture, adaptive optics, wavefront sensors, detectors, stellar interferometers and image reconstruction. What will be the next advances? Emerging data analysis techniques based on communication theory holds the promise of yielding more information from observational data based on significant computer post-processing. This paper explores some of the current telescope limitations and ponders the possibilities increasing the yield of scientific data based on the migration computer post-processing techniques to higher dimensions. Some of these processes hold the promise of reducing the requirements on the basic telescope hardware making the next generation of instruments more affordable.

Smith, W. Scott↗

Visualization of Subsurface Defects in Composites using a Focal Plane Array Infrared Camera

A technique for enhanced defect visualization in composites via transient thermography is presented in this paper. The effort targets automated defect map construction for multiple defects located in the observed area. Experimental data were collected on composite panels of different thickness with square inclusions and flat bottom holes of different depth and orientation. The time evolution of the thermal response and spatial thermal profiles are analyzed. The pattern generated by carbon fibers and the vignetting effect of the focal plane array camera make defect visualization difficult. An improvement of the defect visibility is made by the pulse phase technique and the spatial background treatment. The relationship between a size of a defect and its reconstructed image is analyzed as well. The image processing technique for noise reduction is discussed.

Plotnikov, Yuri A.↗

An overview of vertebrate mineralization with emphasis on collagen-mineral interaction

The nucleation, growth, and development of mineral crystals through their interaction principally with collagen in normal bone and calcifying tendon have been elaborated by applying a number of different techniques for analysis of the inorganic and organic constituents of these tissues. The methods have included conventional and high voltage electron microscopy, electron diffraction, microscopic tomography and 3D image reconstruction, and atomic force microscopy. This summary presents results of these studies that have now characterized the size, shape, and aspects of the chemical nature of the crystals as well as their orientation, alignment, location, and distribution with respect to collagen. These data have provided the means for understanding more completely the formation and strength of the collagen-mineral composite present in most vertebrate calcifying tissues and, from that information, a basis for the adaptation of such tissues under mechanical constraints. In the context of the latter point, other data are given showing effects on collagen in bone cell cultures subjected to the unloading parameters of spaceflight. Implications of these results may be particularly relevant to explaining loss of bone by humans and other vertebrate animals during missions in space, during situations of extended fracture healing, long-term bedrest, physical immobilization, and related conditions. In a broader sense, the data speak to the response of bone and mineralized vertebrate tissues to changes in gravitational loading and applied mechanical forces in general.

Non-NASA Center↗

Testing the TPF Interferometry Approach before Launch

One way to directly detect nearby extra-solar planets is via their thermal infrared emission, and with this goal in mind, both NASA and ESA are investigating cryogenic infrared interferometers. Common to both agencies' approaches to faint off-axis source detection near bright stars is the use of a rotating nulling interferometer, such as the Terrestrial Planet Finder interferometer (TPF-I), or Darwin. In this approach, the central star is nulled, while the emission from off-axis sources is transmitted and modulated by the rotation of the off-axis fringes. Because of the high contrasts involved, and the novelty of the measurement technique, it is essential to gain experience with this technique before launch. Here we describe a simple ground-based experiment that can test the essential aspects of the TPF signal measurement and image reconstruction approaches by generating a rotating interferometric baseline within the pupil of a large singleaperture telescope. This approach can mimic potential space-based interferometric configurations, and allow the extraction of signals from off-axis sources using the same algorithms proposed for the space-based missions. This approach should thus allow for testing of the applicability of proposed signal extraction algorithms for the detection of single and multiple near-neighbor companions...

interferometry↗

South Pole Hydrogen Distribution for Present Lunar Conditions: Implications for Past Impacts

It has been known since the Lunar Prospector mission that the poles of the Moon evidently harbor enhanced concentrations of hydrogen [1,2]. The physical and chemical form of the hydrogen has been much debated. Using imagery from Clementine it was possible to roughly estimate permanently-shadowed regions (PSRs), and to perform image reconstructions of the Lunar Prospector epithermal neutron flux maps [3,4]. The hydrogen concentrations resulting from these reconstructions were consistent with a few weight percent water ice in selected locations. With the LCROSS impact, we now know that hydrogen in the form of ice does exist in lunar polar cold traps [5]. Armed with this information, and new data from LRO/Diviner, we can examine whether the pre-sent-day distribution of hydrogen in the form of water ice is consistent with a past large impact that delivered a large mass of volatiles to the lunar surface. These volatiles, mixed with solid impact ejecta, would then be lost from locations having high mean temperatures but would otherwise remain trapped in locations with sufficiently low mean annual temperatures [6]. The time scales for loss would depend on the location-dependent temperatures as well as impact history.

Elphic, R. C.↗

Sampling Theorem in Terms of the Bandwidth and Sampling Interval

An approach has been developed for interpolating non-uniformly sampled data, with applications in signal and image reconstruction. This innovation generalizes the Whittaker-Shannon sampling theorem by emphasizing two assumptions explicitly (definition of a band-limited function and construction by periodic extension). The Whittaker- Shannon sampling theorem is thus expressed in terms of two fundamental length scales that are derived from these assumptions. The result is more general than what is usually reported, and contains the Whittaker- Shannon form as a special case corresponding to Nyquist-sampled data. The approach also shows that the preferred basis set for interpolation is found by varying the frequency component of the basis functions in an optimal way.

Dean, Bruce H.↗

Reconciling LCROSS and Orbital Neutron Water Abundance Estimates in Cabeus Crater

The Lunar Prospector Neutron Spectrometer (LPNS) first revealed Cabeus crater (84.9 deg S, 35.5degW) as having the highest inferred hydrogen on the Moon. Because of the broad LPNS footprint (approximately 40 km FWHM), the apparent peak water-equivalent hydrogen (WEH) concentration is only approximately 0.25 wt%, but could be much higher in smaller areas than the spectrometer footprint. Earlier image reconstruction work suggested that areas within permanent shadow have abundances approximately 1 wt% WEH. However, the LCROSS impact yielded total water estimates, ice plus vapor, of between 3 and 10 wt%. The large disagreement between LCROSS and apparent orbital values imply that either the ice is buried, by perhaps as much as 50 to 100 cm; or the ice distribution within Cabeus is spatially inhomogeneous, or both. Modeling reveals that the areal extent of a "shallow permafrost zone" is far greater than the area of permanent shadow. Ice can be virtually stable for billions of years within a few tens of centimeters of the surface in these areas. However, the LCROSS impact took place in an area of permanent shadow. If stably-trapped volatiles can be found in locales that receive occasional, oblique sunlight, landed missions may target these sites and eventual resource exploitation may be done more easily. Are orbital neutron data consistent with areally-extensive, volatile-rich cold traps? Orbital epithermal neutron data over the northern half of Cabeus (near the LCROSS impact site) are consistent with 0.2 wt% WEH or less in the "permafrost zone" near the crater. On the other hand, pixon reconstructions that confine the hydrogen enhancements to permanent shadow result in higher abundance estimates -- around 1 wt% if homogeneously mixed. But if the PSR abundance is increased to 10 wt%, consistent with the sum of all H-bearing compounds seen by LCROSS, a much larger-than-observed reduction in neutron count rate would be seen from orbit. It is likely that volatiles are inhomogeneously distributed, due to both impact processes and emplacement history. Two possibilities may bring consistency to the orbital and LCROSS measurements. Inhomogeneous lateral distribution: Consider the extreme case of a bimodal distribution within the crater -- dry and wet. In this case the epithermal leakage flux seen from orbit is a mixture of two different values, weighted according to fractional areas. Two possible outcomes, depending on whether the inferred leakage flux for the PSR or "permafrost" areas are considered. In the first case, approximately 40% of the PSR may be "wet", the remainder dry (and LCROSS was slightly lucky). However, if the whole area of permafrost is considered, then as little as 20% of the area will be as "wet" as the LCROSS results (and LCROSS was quite lucky). Inhomogeneous depth distribution: The leakage flux of thermal and epithermal neutrons depends on depth of burial of an icy layer beneath dry ferroan anorthosite soil (FAn). For the Cabeus PSR, the pixon reconstruction values for the epithermal flux allows a range of abundance and burial depth, while that of the thermal+epi detector constrains this range. (Uncertainties in iron abundance in the FAn can have significant impact on thermal neutron leakage flux estimates.) Between 20% and 40% of the Cabeus floor may be "wet", or alternatively a 5-10 wt% "wet" layer exists between 50 and 100 cm beneath a layer of dry regolith within the PSR. But volatile abundances of 5 wt% or more, distributed uniformly and homogeneously throughout the Cabeus PSR do not agree with orbital measurements

Elphic, Richard↗

Spatially Resolved Temperature and Water Vapor Concentration Distributions in Supersonic Combustion Facilities by TDLAT

Detailed knowledge of the internal structure of high-enthalpy flows can provide valuable insight to the performance of scramjet combustors. Tunable Diode Laser Absorption Spectroscopy (TDLAS) is often employed to measure temperature and species concentration. However, TDLAS is a path-integrated line-of-sight (LOS) measurement, and thus does not produce spatially resolved distributions. Tunable Diode Laser Absorption Tomography (TDLAT) is a non-intrusive measurement technique for determining two-dimensional spatially resolved distributions of temperature and species concentration in high enthalpy flows. TDLAT combines TDLAS with tomographic image reconstruction. More than 2500 separate line-of-sight TDLAS measurements are analyzed in order to produce highly resolved temperature and species concentration distributions. Measurements have been collected at the University of Virginia's Supersonic Combustion Facility (UVaSCF) as well as at the NASA Langley Direct-Connect Supersonic Combustion Test Facility (DCSCTF). Due to the UVaSCF s unique electrical heating and ability for vitiate addition, measurements collected at the UVaSCF are presented as a calibration of the technique. Measurements collected at the DCSCTF required significant modifications to system hardware and software designs due to its larger measurement area and shorter test duration. Tomographic temperature and water vapor concentration distributions are presented from experimentation on the UVaSCF operating at a high temperature non-reacting case for water vitiation level of 12%. Initial LOS measurements from the NASA Langley DCSCTF operating at an equivalence ratio of 0.5 are also presented. Results show the capability of TDLAT to adapt to several experimental setups and test parameters.

Busa, K. M.↗

Measurements on NASA Langley Durable Combustor Rig by TDLAT: Preliminary Results

Detailed knowledge of the internal structure of high-enthalpy flows can provide valuable insight to the performance of scramjet combustors. Tunable Diode Laser Absorption Spectroscopy (TDLAS) is often employed to measure temperature and species concentration. However, TDLAS is a path-integrated line-of-sight (LOS) measurement, and thus does not produce spatially resolved distributions. Tunable Diode Laser Absorption Tomography (TDLAT) is a non-intrusive measurement technique for determining two-dimensional spatially resolved distributions of temperature and species concentration in high enthalpy flows. TDLAT combines TDLAS with tomographic image reconstruction. Several separate line-of-sight TDLAS measurements are analyzed in order to produce highly resolved temperature and species concentration distributions. Measurements have been collected at the University of Virginia's Supersonic Combustion Facility (UVaSCF) as well as at the NASA Langley Direct-Connect Supersonic Combustion Test Facility (DCSCTF). Measurements collected at the DCSCTF required significant modifications to system hardware and software designs due to its larger measurement area and shorter test duration. Initial LOS measurements from the NASA Langley DCSCTF operating at an equivalence ratio of 0.5 are presented. Results show the capability of TDLAT to adapt to several experimental setups and test parameters.

Busa, Kristin↗

Time-Domain Terahertz Computed Axial Tomography NDE System

NASA has identified the need for advanced non-destructive evaluation (NDE) methods to characterize aging and durability in aircraft materials to improve the safety of the nation's airline fleet. 3D THz tomography can play a major role in detection and characterization of flaws and degradation in aircraft materials, including Kevlar-based composites and Kevlar and Zylon fabric covers for soft-shell fan containment where aging and durability issues are critical. A prototype computed tomography (CT) time-domain (TD) THz imaging system has been used to generate 3D images of several test objects including a TUFI tile (a thermal protection system tile used on the Space Shuttle and possibly the Orion or similar capsules). This TUFI tile had simulated impact damage that was located and the depth of damage determined. The CT motion control gan try was designed and constructed, and then integrated with a T-Ray 4000 control unit and motion controller to create a complete CT TD-THz imaging system prototype. A data collection software script was developed that takes multiple z-axis slices in sequence and saves the data for batch processing. The data collection software was integrated with the ability to batch process the slice data with the CT TD-THz image reconstruction software. The time required to take a single CT slice was decreased from six minutes to approximately one minute by replacing the 320 ps, 100-Hz waveform acquisition system with an 80 ps, 1,000-Hz waveform acquisition system. The TD-THZ computed tomography system was built from pre-existing commercial off-the-shelf subsystems. A CT motion control gantry was constructed from COTS components that can handle larger samples. The motion control gantry allows inspection of sample sizes of up to approximately one cubic foot (.0.03 cubic meters). The system reduced to practice a CT-TDTHz system incorporating a COTS 80- ps/l-kHz waveform scanner. The incorporation of this scanner in the system allows acquisition of 3D slice data with better signal-to-noise using a COTS scanner rather than the gchirped h scanner. The system also reduced to practice a prototype for commercial CT systems for insulating materials where safety concerns cannot accommodate x-ray. A software script was written to automate the COTS software to collect and process TD-THz CT data.

Zimdars, David↗

PATOKA: Simulating Electromagnetic Observables of Black Hole Accretion

The Event Horizon Telescope (EHT) has released analyses of reconstructed images of horizon-scale millimeter emission near the supermassive black hole at the center of the M87 galaxy. Parts of the analyses made use of a large library of synthetic black hole images and spectra, which were produced using numerical general relativistic magnetohydrodynamics fluid simulations and polarized ray tracing. In this article, we describe the PATOKA pipeline, which was used to generate the Illinois contribution to the EHT simulation library. We begin by describing the relevant accretion systems and radiative processes. We then describe the details of the three numerical codes we use, iharm, ipole, and igrmonty, paying particular attention to differences between the current generation of the codes and the originally published versions. Finally, we provide a brief overview of simulated data as produced by PATOKA and conclude with a discussion of limitations and future directions.

supermassive black holes↗

Electric Field Reconstruction in the Image Plane of a High-Contrast Coronagraph Using a Set of Pinholes around the Lyot Plane

In a setup similar to the self coherent camera, we have added a set of pinholes in the diffraction ring of the Lyot plane in a high-contrast stellar Lyot coronagraph. We describe a novel complex electric field reconstruction from image plane intensity measurements consisting of light in the coronagraph's dark hole interfering with light from the pinholes. The image plane field is modified by letting light through one pinhole at a time. In addition to estimation of the field at the science camera, this method allows for self-calibration of the probes by letting light through the pinholes in various permutations while blocking the main Lyot opening. We present results of estimation and calibration from the High Contrast Imaging Testbed along with a comparison to the pair-wise deformable mirror diversity based estimation technique. Tests are carried out in narrow-band light and over a composite 10% bandpass.

coronagraphs↗

Three-Dimensional Imaging and Numerical Reconstruction of Graphite/Epoxy Composite Microstructure Based on Ultra-High Resolution X-Ray Computed Tomography

A combined experimental and computational study aimed at high-resolution 3D imaging, visualization, and numerical reconstruction of fiber-reinforced polymer microstructures at the fiber length scale is presented. To this end, a sample of graphite/epoxy composite was imaged at sub-micron resolution using a 3D X-ray computed tomography microscope. Next, a novel segmentation algorithm was developed, based on concepts adopted from computer vision and multi-target tracking, to detect and estimate, with high accuracy, the position of individual fibers in a volume of the imaged composite. In the current implementation, the segmentation algorithm was based on Global Nearest Neighbor data-association architecture, a Kalman filter estimator, and several novel algorithms for virtualfiber stitching, smoothing, and overlap removal. The segmentation algorithm was used on a sub-volume of the imaged composite, detecting 508 individual fibers. The segmentation data were qualitatively compared to the tomographic data, demonstrating high accuracy of the numerical reconstruction. Moreover, the data were used to quantify a) the relative distribution of individual-fiber cross sections within the imaged sub-volume, and b) the local fiber misorientation relative to the global fiber axis. Finally, the segmentation data were converted using commercially available finite element (FE) software to generate a detailed FE mesh of the composite volume. The methodology described herein demonstrates the feasibility of realizing an FE-based, virtual-testing framework for graphite/fiber composites at the constituent level.

Czabaj, M. W.↗

A New Method to Use Chandra Data to Resolve the X-Ray Halos Around Point Sources and Its Application to Cygnus X-1

The excellent angular resolution, good energy resolution and broad energy band make Chandra ACIS the best instrument for studying the X-ray halos around some galactic x-ray point sources caused by the dust scattering of X-rays in the interstellar medium, but direct images of bright sources of b r i g h t sources obtained with ACIS usually from severe pile- UP - Making use of the fact that an isotropic image could be reconstructed from it's projection on any direction, we can reconstruct the images of the X-ray halos from data obtained with the regular HETGS and/or the CC mode. With the reconstructed high resolution images, we can probe the X-ray halos as close as 1 arcsecond to their associated point sources.

Yao, Y.↗

Comprehensive Non-Destructive Conservation Documentation of Lunar Samples Using High-Resolution Image-Based 3D Reconstructions and X-Ray CT Data

Established contemporary conservation methods within the fields of Natural and Cultural Heritage encourage an interdisciplinary approach to preservation of heritage material (both tangible and intangible) that holds "Outstanding Universal Value" for our global community. NASA's lunar samples were acquired from the moon for the primary purpose of intensive scientific investigation. These samples, however, also invoke cultural significance, as evidenced by the millions of people per year that visit lunar displays in museums and heritage centers around the world. Being both scientifically and culturally significant, the lunar samples require a unique conservation approach. Government mandate dictates that NASA's Astromaterials Acquisition and Curation Office develop and maintain protocols for "documentation, preservation, preparation and distribution of samples for research, education and public outreach" for both current and future collections of astromaterials. Documentation, considered the first stage within the conservation methodology, has evolved many new techniques since curation protocols for the lunar samples were first implemented, and the development of new documentation strategies for current and future astromaterials is beneficial to keeping curation protocols up to date. We have developed and tested a comprehensive non-destructive documentation technique using high-resolution image-based 3D reconstruction and X-ray CT (XCT) data in order to create interactive 3D models of lunar samples that would ultimately be served to both researchers and the public. These data enhance preliminary scientific investigations including targeted sample requests, and also provide a new visual platform for the public to experience and interact with the lunar samples. We intend to serve these data as they are acquired on NASA's Astromaterials Acquisistion and Curation website at http://curator.jsc.nasa.gov/. Providing 3D interior and exterior documentation of astromaterial samples addresses the increasing demands for accessability to data and contemporary techniques for documentation, which can be realized for both current collections as well as future sample return missions.

Blumenfeld, E. H.↗

Dictionary Approaches to Image Compression and Reconstruction

This paper proposes using a collection of parameterized waveforms, known as a dictionary, for the purpose of medical image compression. These waveforms, denoted as lambda, are discrete time signals, where y represents the dictionary index. A dictionary with a collection of these waveforms Is typically complete or over complete. Given such a dictionary, the goal is to obtain a representation Image based on the dictionary. We examine the effectiveness of applying Basis Pursuit (BP), Best Orthogonal Basis (BOB), Matching Pursuits (MP), and the Method of Frames (MOF) methods for the compression of digitized radiological images with a wavelet-packet dictionary. The performance of these algorithms is studied for medical images with and without additive noise.

Ziyad, Nigel A.↗

Dictionary Approaches to Image Compression and Reconstruction

This paper proposes using a collection of parameterized waveforms, known as a dictionary, for the purpose of medical image compression. These waveforms, denoted as phi(sub gamma), are discrete time signals, where gamma represents the dictionary index. A dictionary with a collection of these waveforms is typically complete or overcomplete. Given such a dictionary, the goal is to obtain a representation image based on the dictionary. We examine the effectiveness of applying Basis Pursuit (BP), Best Orthogonal Basis (BOB), Matching Pursuits (MP), and the Method of Frames (MOF) methods for the compression of digitized radiological images with a wavelet-packet dictionary. The performance of these algorithms is studied for medical images with and without additive noise.

Ziyad, Nigel A.↗

A New Method to Resolve X-Ray Halos around Point Sources with Chandra Data and Its Application to Cygnus X-1

With excellent angular resolution, good energy resolution, and a broad energy band, the Chandra Advanced CCD Imaging Spectrometer (ACIS) is the best instrument for studying the X-ray halos around some Galactic X-ray point sources caused by the dust scattering of X-rays in the interstellar medium. However, the direct images of bright sources obtained with the ACIS usually suffer from severe pileup. Making use of the fact that an isotropic image could be reconstructed from its projection in to any direction, we can reconstruct the images of the X-ray halos from the data obtained with the High Energy Transition Grating Spectrometer (HETGS) and/or in continuos clocking (CC) mode. These data have no or less serious pileup and enable us to take full advantage of the excellent angular resolution of Chandra. With the reconstructed high-resolution images, we can probe the X-ray halos as close as 1" to their associated point sources. Applying this method to Cygnus X-1 observed with the Chandra HETGS in CC mode, we derived an energy-dependent radial halo flux distribution and concluded that in a circular region (2' in radius) centered a the point source: (1) relative to the total intensity, the fractional halo intensity is about 15% at keV and drops to aboout 5% at approximately 6 keV (2) about 50% of the halo photons are within the region of a radius less than 40 inches and (3) the spectrum of the pooint source is slightly distorted by the halo contamination.

Yao, Yangsen↗