Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Multiresolution image gathering and restoration

In this paper we integrate multiresolution decomposition with image gathering and restoration. This integration leads to a Wiener-matrix filter that accounts for the aliasing, blurring, and noise in image gathering, together with the digital filtering and decimation in signal decomposition. Moreover, as implemented here, the Wiener-matrix filter completely suppresses the blurring and raster effects of the image-display device. We demonstrate that this filter can significantly improve the fidelity and visual quality produced by conventional image reconstruction. The extent of this improvement, in turn, depends on the design of the image-gathering device.

Fales, Carl L.↗

Photon-Sparse, Poisson Light-Sheet Microscopy

Light-sheet microscopy has revolutionized bioimaging by enabling approximately an order of magnitude reduction in specimen irradiance compared to confocal imaging. Here, we introduce a light-sheet imaging system that enables an additional order of magnitude reduction in specimen irradiance by operating at the Poisson limit. To operate at this limit, we integrated classical illumination with single-photon detection and wavelet-based image reconstruction. This integration enabled brightness quantification and object recognition from fewer than one detected photon per image pixel, corresponding to more than 10-fold lower irradiance levels than modern systems. We demonstrate how such photon-sparse imaging can eradicate photobleaching and enable both dim and bright object imaging, thus, further enhancing the related gains of light-sheet microscopy.

60 APPLIED LIFE SCIENCES↗

Image Compression Algorithm Altered to Improve Stereo Ranging

A report discusses a modification of the ICER image-data-compression algorithm to increase the accuracy of ranging computations performed on compressed stereoscopic image pairs captured by cameras aboard the Mars Exploration Rovers. (ICER and variants thereof were discussed in several prior NASA Tech Briefs articles.) Like many image compressors, ICER was designed to minimize a mean-square-error measure of distortion in reconstructed images as a function of the compressed data volume. The present modification of ICER was preceded by formulation of an alternative error measure, an image-quality metric that focuses on stereoscopic-ranging quality and takes account of image-processing steps in the stereoscopic-ranging process. This metric was used in empirical evaluation of bit planes of wavelet-transform subbands that are generated in ICER. The present modification, which is a change in a bit-plane prioritization rule in ICER, was adopted on the basis of this evaluation. This modification changes the order in which image data are encoded, such that when ICER is used for lossy compression, better stereoscopic-ranging results are obtained as a function of the compressed data volume.

Kiely, Aaron↗

Computing Challenges in Coded Mask Imaging

This slide presaentation reviews the complications and challenges in developing computer systems for Coded Mask Imaging telescopes. The coded mask technique is used when there is no other way to create the telescope, (i.e., when there are wide fields of view, high energies for focusing or low energies for the Compton/Tracker Techniques and very good angular resolution.) The coded mask telescope is described, and the mask is reviewed. The coded Masks for the INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL) instruments are shown, and a chart showing the types of position sensitive detectors used for the coded mask telescopes is also reviewed. Slides describe the mechanism of recovering an image from the masked pattern. The correlation with the mask pattern is described. The Matrix approach is reviewed, and other approaches to image reconstruction are described. Included in the presentation is a review of the Energetic X-ray Imaging Survey Telescope (EXIST) / High Energy Telescope (HET), with information about the mission, the operation of the telescope, comparison of the EXIST/HET with the SWIFT/BAT and details of the design of the EXIST/HET.

Skinner, Gerald↗

Distributed Stochastic Optimization of a Neural Representation Network for Time-Space Tomography Reconstruction

4D time-space reconstruction of dynamic events or deforming objects using X-ray computed tomography (CT) is an important inverse problem in non-destructive evaluation. Conventional back-projection based reconstruction methods assume that the object remains static for the duration of several tens or hundreds of X-ray projection measurement images (reconstruction of consecutive limited-angle CT scans). However, this is an unrealistic assumption for many in-situ experiments that causes spurious artifacts and inaccurate morphological reconstructions of the object. To solve this problem, we propose to perform a 4D time-space reconstruction using a distributed implicit neural representation (DINR) network that is trained using a novel distributed stochastic training algorithm. Our DINR network learns to reconstruct the object at its output by iterative optimization of its network parameters such that the measured projection images best match the output of the CT forward measurement model. Here, we use a forward measurement model that is a function of the DINR outputs at a sparsely sampled set of continuous valued 4D object coordinates. Unlike previous neural representation architectures that forward and back propagate through dense voxel grids that sample the object's entire time-space coordinates, we only propagate through the DINR at a small subset of object coordinates in each iteration resulting in an order-of-magnitude reduction in memory and compute for training. DINR leverages distributed computation across several compute nodes and GPUs to produce high-fidelity 4D time-space reconstructions. We use both simulated parallel-beam and experimental cone-beam X-ray CT datasets to demonstrate the superior performance of our approach.

36 MATERIALS SCIENCE↗

Synchrotron X-ray microtomography and multifractal analysis for the characterization of pore structure and distribution in softwood pellet biochar

Biochar pores in the micrometer range (1–100 µm) derive from cellular structures of the plant biomass subjected to pyrolysis or can be the result of mechanical processing, such as pelleting. In this study, synchrotron X-ray microtomography was used to investigate the internal pore structure of softwood pellet biochar produced by slow pyrolysis at 550 and 700 °C. The microtomographic data sets consisted of 2025 images of 2560 × 2560 voxels with a voxel side length of 0.87 µm. The three-dimensional reconstructions revealed that pelleting and pyrolysis significantly altered the pore structures of the wood feedstock, creating a network of connected pores between fragments that resembled the wood morphology. While higher pyrolysis temperature increased the specific surface area (as determined by BET nitrogen adsorption), it did not affect the total observed porosity. Multifractal analysis was applied to assess the characteristics of the frequency distribution of pores along each of the three dimensions of reconstructed images of five softwood pellet biochar samples. The resulting singularity and Rényi spectra (generalized dimensions) indicated that the distribution of porosity had monofractal scaling behavior, was homogeneous within the analyzed volumes and consistent between replicate samples. Moreover, the pore distributions were isotropic (direction-independent), which is in strong contrast with the anisotropic pore structure of wood. As pores at the scale analyzed in this study are relevant, for example, for the supply of plant accessible water and habitable space for microorganisms, our findings combined with the ability to reproduce biochar with such pore distribution offer substantial advantages in various biochar applications.

59 BASIC BIOLOGICAL SCIENCES↗

Assessing methods in fusion and fitting for time series construction in remote sensing-based earth observations

This study evaluates the comparative performance of spatiotemporal fusion and time-series fitting methods for constructing high-spatiotemporal-resolution remote sensing time-series data. Due to in-class similarity of fusion methods and fitting methods, we employ the Fit-FC (Fitting, spatial Filtering, and residual Compensation) model as a representative fusion method and the linear harmonic fitting model as a representative fitting method. Both Fit-FC and the linear harmonic fitting are widely used for high-spatiotemporal-resolution time-series data construction, and we modify the original Fit-FC model to enable automatic time-series fusion. To ensure data representativeness, we use 3 years (2019–2021) of Harmonized Landsat and Sentinel-2 surface reflectance datasets and Terra MCD43A4 products. Eight experimental regions are selected worldwide to guarantee generalization of the comparative performance between fusion and fitting methods, covering diverse land-use types (cropland, developed land, forest, and grassland) and varying climatological conditions. Time-series of NDVI and surface reflectance are analyzed under both actual observations and simulated data-missing scenarios. The constructed time-series data reveals that (1) the modified Fit-FC and linear harmonic fitting model achieve excellent performance in constructing high-resolution time-series images; (2) the fusion method outperforms the fitting method in constructing time-series of NDVI and surface reflectance images in cropland-, forest-, and grassland-dominated regions; (3) both methods achieve comparable performance in developed-dominated regions; (4) the fusion method is more robust to missing data, and better captures abrupt phenological transitions under conditions of continuous missing data; (5) the fitting method is computationally more efficient, making it suitable for large-scale time-series image reconstruction. This study provides valuable insights for selecting optimal strategies to generate high-resolution time-series images across diverse application scenarios and lays a foundation for extensions to other vegetation indices or land surface variables.

54 ENVIRONMENTAL SCIENCES↗

Fidelity-preserving enhancement of ptychography with foundational text-to-image models

Ptychographic phase retrieval enables high-resolution imaging of complex samples but often suffers from artifacts such as grid pathology and multislice crosstalk, which degrade reconstructed images. We propose a plug-and-play (PnP) framework that integrates physics model-based phase retrieval with text-guided image editing using foundational diffusion models. By employing the alternating direction method of multipliers, our approach ensures consensus between data fidelity and artifact removal subproblems, maintaining physical consistency while enhancing image quality. Artifact removal is achieved using a text-guided diffusion image editing method (LEDITS++) with a pre-trained foundational diffusion model, allowing users to specify artifacts for removal in natural language. Demonstrations on simulated and experimental datasets show significant improvements in artifact suppression and structural fidelity, validated by metrics such as peak signal-to-noise ratio and diffraction pattern consistency. This work highlights the combination of text-guided generative models and model-based phase retrieval algorithms as a transferable and fidelity-preserving method for high-quality diffraction imaging.

image editing↗

Ringing Artifact Reduction Method for Ultrasound Reconstruction Using Multi-Agent Consensus Equilibrium

Non-destructive characterization of multi-layered structures that can be accessed from only a single side is important for applications such as well-bore integrity inspection. Existing methods related to Synthetic Aperture Focusing Technique (SAFT) rapidly produce acceptable results but with significant artifacts. Recently, ultrasound model-based iterative reconstruction (UMBIR) approaches have shown significant improvements over SAFT. However, even these methods produce ringing artifacts due to the high fractional-bandwidth of the excitation signal.In this paper, we propose a ringing artifact reduction method for ultrasound image reconstruction that uses a multi-agent consensus equilibrium (RARE-MACE) framework. Our approach integrates a physics-based forward model that accounts for the propagation of a collimated ultrasonic beam in multi-layered media, a spatially varying image prior, and a denoiser designed to suppress the ringing artifacts that are characteristic of reconstructions from high-fractional bandwidth ultrasound sensor data. We test our method on simulated and experimental measurements and show substantial improvements in image quality compared to SAFT and UMBIR.

Alanazi, Abdulrahman M↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

Super Resolution Digital Image Correlation (SR-DIC): an Alternative to Image Stitching at High Magnifications

Abstract Background High-resolution Digital Image Correlation (DIC) measurements have previously been produced by stitching of neighboring images, which often requires short working distances. Separately, the image processing community has developed super resolution (SR) imaging techniques, which improve resolution by combining multiple overlapping images. Objective This work investigates the novel pairing of super resolution with digital image correlation, as an alternative method to produce high-resolution full-field strain measurements. Methods First, an image reconstruction test is performed, comparing the ability of three previously published SR algorithms to replicate a high-resolution image. Second, an applied translation is compared against DIC measurement using both low- and super-resolution images. Third, a ring sample is mechanically deformed and DIC strain measurements from low- and super-resolution images are compared. Results SR measurements show improvements compared to low-resolution images, although they do not perfectly replicate the high-resolution image. SR-DIC demonstrates reduced error and improved confidence in measuring rigid body translation when compared to low resolution alternatives, and it also shows improvement in spatial resolution for strain measurements of ring deformation. Conclusions Super resolution imaging can be effectively paired with Digital Image Correlation, offering improved spatial resolution, reduced error, and increased measurement confidence.

Hansen, R. S.↗

Speckle interferometry of asteroids

Steward Observatory's two-dimensional power spectrum signature analysis of speckle interferometry observations is summarized. Results for six asteroids are presented. The poles and triaxial ellipsoid dimensions of 4 Vesta, 433 Eros, 511 Davida, and 532 Herculina have been previously reported. New results for 2 Pallas and 29 Amphitrite are given, as well as further results for Vesta. Image reconstruction is ultimately required to minimize biasing effects of asteroid surface features on the simpler power spectrum analysis. Preliminary imaging results have been achieved for Vesta and Eros, and images for these two are displayed. Speckle interferometry and radiometry diameters are compared, and diameters from the two occultations of Pallas are addressed.

Drummond, Jack D.↗

Astronomy and astrophysics with the Advanced X-ray Astrophysics Facility

The optics and instruments of the Advanced X-ray Astrophysics Facility (AXAF) are described. The instrument capabilities are reviewed so that potential users of AXAF may plan supporting research in the years prior to launch. The AXAF is to be built around a large-area high-resolution grazing-incidence X-ray telescope, with a complement of imaging and spectroscopic instruments which can be maintained and/or replaced in orbit. An important feature of the AXAF is the aspect system. It utilizes solid state star cameras and fiducial lights to permit both image reconstruction (on the ground) with minimal blurring due to spacecraft and internal motions, and placement of the X-ray image on the sky to an accuracy of 1 arcsec.

Weisskopf, Martin C.↗

Computerized tomographic imaging for space plasma physics

The measurement of plasma electron velocity distribution functions as a problem in imaging and image reconstruction is considered. A model instrument that measures the integral of the distribution function along lines in velocity space is presented. This allows the use of the powerful mathematical and numerical methods that have recently been so successful in other areas of imaging. It is found that this approach leads to classes of instruments that are qualitatively different from contemporary designs. An investigation of different methods of reconstruction of the distribution function from integral measurements reveals that the mathematical tools appropriate to one particular imaging problem may be very different from those required to deal with another.

Zhang, Yuhong↗

Compressing subbanded image data with Lempel-Ziv-based coders

A method of improving the compression of image data using Lempel-Ziv-based coding is presented. Image data is first processed with a simple transform, such as the Walsh Hadamard Transform, to produce subbands. The subbanded data can be rounded to eight bits or it can be quantized for higher compression at the cost of some reduction in the quality of the reconstructed image. The data is then run-length coded to take advantage of the large runs of zeros produced by quantization. Compression results are presented and contrasted with a subband compression method using quantization followed by run-length coding and Huffman coding. The Lempel-Ziv-based coding in conjunction with run-length coding produces the best compression results at the same reconstruction quality (compared with the Huffman-based coding) on the image data used.

Glover, Daniel↗

Reduced volume of diabetic pancreatic islets in rodents detected by synchrotron X-ray phase-contrast microtomography and deep learning network

The pancreatic islet is a highly structured micro-organ that produces insulin in response to rising blood glucose. Here we develop a label-free and automatic imaging approach to visualize the islets in situ in diabetic rodents by the synchrotron radiation X-ray phase-contrast microtomography (SRμCT) at the ID17 station of the European Synchrotron Radiation Facility. The large-size images (3.2 mm × 15.97 mm) were acquired in the pancreas in STZ-treated mice and diabetic GK rats. Each pancreas was dissected by 3000 reconstructed images. The image datasets were further analysed by a self-developed deep learning method, AA-Net. All islets in the pancreas were segmented and visualized by the three-dimension (3D) reconstruction. After quantifying the volumes of the islets, we found that the number of larger islets (=>1500 μm 3 ) was reduced by 2-fold (wt 1004 ± 94 vs GK 419 ± 122, P < 0.001) in chronically developed diabetic GK rat, while in STZ-treated diabetic mouse the large islets were decreased by half (189 ± 33 vs 90 ± 29, P < 0.001) compared to the untreated mice. Our study provides a label-free tool for detecting and quantifying pancreatic islets in situ. It implies the possibility of monitoring the state of pancreatic islets in vivo diabetes without labelling.

59 BASIC BIOLOGICAL SCIENCES↗