Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Hydrothermal mineral alterations in the Brady and Desert Peak geothermal fields

Results of the analysis of HyMap's spectra against know hydrothermally altered minerals in the Brady-Desert Peak Geothermal Areas. The analysis was performed using ENVI's Target Detection process against USGS library spectra for Chalcedony, Kaolinite, Gypsum, Hematite and Epsomite. Each compressed file includes three raster images created after fusing the target detection results for all minerals: _fusion_all - Contains the 8 layers resulting from target detection and fusion of the 5 minerals _fusion_all_normal - Contains each layer as above, after Winsorization (99% percentile on the positive side only due to skewness of results), and normalization of each layer to achieve a range between [0-1] _fusion_final - Contains a fused raster by sub-setting the normalized layers, with the results of MTMF, MTTCIMF, OSP and SAM. Both CEM and MF were discarded as being less accurate than MTMF, and TCIMF is less accurate than MTTCIMF, ACE results were discarded because they were notably different from the rest of the analyses. The base_names are: brady - Brady geothermal area only desert - Desert Peak geothermal area only hymap - Full image analysis comprising both the Brady and Desert Peak geothermal areas

15 GEOTHERMAL ENERGY↗

Using deep machine learning to interpret proton radiography data from a pulsed power experiment

Deep machine learning is used to analyze a proton radiograph from a tin pulsed power experiment and determine density values for each pixel in the image. Two promising convolutional neural network architectures that have proven to be effective for image analysis in other applications are applied to analyze a proton radiograph and find density values. The process of creating a suitable training dataset is described, involving the Lagrangian hydrodynamic model used for simulations of the experiment, the proton radiography forward model to make synthetic images for training, and the manner in which data augmentation is used to expand the resulting image dataset. It is shown that machine learning not only produces a reasonable density field but is also able to predict features in the density field that are suggested by the proton radiograph but not captured by simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Open Specy 1.0: Automated (Hyper)spectroscopy for Microplastics

Microplastic spectral analysis is one of the most time-consuming processes in studying microplastic pollution, often requiring days per sample. Researchers are transitioning to automated batch and hyperspectral image analysis techniques to enhance efficiency. Open Specy, initially aimed at manual single-spectrum analysis, has now integrated automated methods. This updated version, Open Specy 1.0, introduces several new features, including two algorithms for automated processing (smoothing and particle compression), an extensive library containing over 40,000 open-source Raman and FTIR spectra, and two machine learning classifiers (logistic regression and k medoids) developed from this library. Furthermore, it includes a revamped user interface, an R package, and a benchmark data set for testing future advancements in automated techniques. Researchers evaluated various configurations for hyperspectral smoothing, particle identification, compression, and splitting, to achieve combined recovery rates between 50 and 150% particle counts, identities, and sizes with a coefficient of variation (CV) of less than 40% (the accredited standard). Mean absorbance times the standard deviation provided a consistent particle identification. Hyperspectral smoothing led to a 96% combined recovery rate and reduced variability (CV = 38%) compared to the 86% recovery (CV = 83%) of nonsmoothed controls. Additionally, compressing spectra for particles was significantly faster (>3x) and showed similar accuracy but with reduced variability than processing each pixel individually. Key challenges persist in automating spectral analysis, particularly in refining particle splitting algorithms, and improving identification routines to minimize false positives and negatives. In conclusion, new methods in sample preparation for better stabilization and dispersion of particles could overcome some of these issues.

13 HYDRO ENERGY↗

3D Structure of Oil Droplets in Hardened Geopolymer Emulsions: Impact of Various Commercial Liquid Oils - 20184

Cement-based solidification/stabilization (S/S) is a widely applied technique for the immobilization of inorganic hazardous constituents. However, S/S is considered less compatible for organic liquid waste (OLW) because organic compounds may inhibit binder hydration. Geopolymers (i.e. alumino-silicate materials) are an alternative for applications in which Portland cements are inappropriate. In a previous work, we proposed a direct immobilization of organic liquid waste in a geopolymer binder (GEOIL composite). We demonstrated the feasibility for producing various composites on model system (hexadecane) and on a hydraulic oil, which are dispersed in the geopolymer binder as droplets (10-50 μm typical size). In nuclear facilities, legacy waste based on organic liquids are currently stored. Many of them have been used for various applications in the nuclear industry (lubrication, cutting, analysis, liquid/liquid extraction..) with very wide chemical compositions. In this study, we study the influence of various commercial organic oils immobilized in hardened geopolymer emulsions by X-ray micro-tomography. Image analysis make it possible to determine the 3D spatial and size distributions of oil droplets in geopolymer emulsions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A digital holography ex situ measurement characterization of plasma-exposed surface erosion from an electrothermal arc source

Digital holography has been proposed to fulfill a need for an imaging diagnostic capable of in situ monitoring of surface erosion caused by plasma–material interaction in nuclear fusion devices. A digital holography diagnostic for 3D surface erosion measurement has been developed at Oak Ridge National Laboratory with the goal of deployment on a plasma device. A proof-of-concept in situ demonstration is planned which would involve measurement of plasma erosion on targets exposed to an electrothermal arc source. This work presents the results of an ex situ characterization of the capability and limitations of holographic imaging of targets exposed to the arc source. Targets were designed to provide a fiducial for comparison of deformed and unaffected areas. The results indicated that the average net erosion was ~150 nm/plasma exposure, which is expected to be within the diagnostic’s measurement capacity. Surface roughness averages determined by holographic image analysis showed good agreement with measurements taken with a profilometer. Finally, the limit of the holography diagnostic’s x–y spatial resolution was characterized by comparison with scanning electron microscope imaging.

47 OTHER INSTRUMENTATION↗

Adaptively coupled phase retrieval in multi-peak Bragg coherent diffraction imaging

Recent advances in Bragg coherent diffraction imaging (BCDI) experimental techniques permit routine measurement of multiple Bragg peaks from a single crystalline grain. The resulting images contain the full lattice distortion vector field which can be differentiated to provide lattice strain and rotation. With the advent of fourth-generation synchrotron light sources, such multi-peak datasets are produced at high rates, facilitating the need for rapid phase retrieval of the multiple peaks and subsequent image analysis. Here we describe and demonstrate a new implementation of a coupled phase retrieval technique for multi-peak BCDI which simultaneously treats each Bragg peak of the dataset and produces a three-dimensional image of the crystal's morphology and lattice distortion field. In addition, this method uses the redundant information contained in the various Bragg diffraction patterns to detect and suppress spurious signal appearing on the detector in a subset of the measurements. Compared with manual data editing, adaptive coupling produces a more consistent phase profile in reciprocal space and sharper surfaces in direct space, with no significant difference in computational cost. These improvements reduce the need for manual preprocessing and enable robust high-throughput analysis of multi-peak BCDI data, supporting near-real-time strain microscopy at modern synchrotron facilities.

36 MATERIALS SCIENCE↗

ESIAS Pseudocode

The Explosive Shock Image Analysis System (ESAIS) is designed to provide a semiautomated quantitative analysis of fast-frame imagery taken during the detonation of high explosive (HE) rate sticks. ESIAS does this by assisting the user in identifying the HE stick geometry on the image (i.e., sides of the undetonated HE stick, detonation front, an axial reference point to assist in the inter-comparison of images); scaling the images based on the known diameter of the undetonated HE stick; identifying the profiles of various surfaces resulting from the detonation process such as the shock wave and product gases or the outer pipe surface; calculating the detonation speed of the HE by tracking the distance it travels between two images with a known time lapse between the images; and determining the slit velocities resulting from the detonation. ESIAS will also import scope traces from oscilloscopes and assist in identifying the time of arrival of significant peaks.

97 MATHEMATICS AND COMPUTING↗

Effects of overlapping sources on cosmic shear estimation: Statistical sensitivity and pixel-noise bias

The next generation of dark-energy imaging surveys — so called “Stage-IV” surveys, such as that of the Rubin Observatory Legacy Survey of Space and Time (LSST) — will cross a threshold in the number density of detected sources on the sky that requires qualitatively different image analysis and measurement techniques compared to the current generation of Stage-III surveys. In Stage-IV surveys, a significant amount of the cosmologically useful information is due to sources whose images overlap with those of other sources on the sky. Here, we focus on the weak gravitational lensing probe, for which we expect the largest impact since the cosmic shear signal is primarily encoded in the estimated shapes of observed galaxies and thus directly impacted by overlaps. We introduce a framework based on the Fisher formalism to analyze the effect of the overlapping sources (“blending”) on the estimation of cosmic shear. This method gives concrete predictions for the minimum loss of information due to noise and blending for any choice of “deblending” scheme and shape-measurement algorithm. Our studies account for undetected sources but do not address their full effects and biases they may introduce. We use simulated images and predict this impact of blending for three surveys: the Dark Energy Survey (DES), the Hyper-Suprime Cam Subaru Strategic Program (HSC-SSP), and the Rubin LSST. Our methodology successfully estimates the statistical sensitivity to weak lensing for DES and HSC early results. For LSST, we present the expected loss in statistical sensitivity for the ten-year survey due to blending. We find that for approximately 62% of galaxies that are likely to be detected in full-depth LSST images, at least 1% of the flux in their pixels is from overlapping sources. We also find that the statistical correlations between measures of overlapping galaxies and, to a much lesser extent (0.2%) the higher shot noise level due to their presence, decrease the effective number density of galaxies, N eff , by ~ 18%. We calculate an upper limit on N eff of 39.4 galaxies per arcmin 2 in r band. We study the impact of stars on as a function of stellar density and illustrate the diminishing returns of extending the survey into lower Galactic latitudes. We extend the simulation-based Fisher formalism to predict the expected increase in pixel-noise bias due to blending for maximum-likelihood (ML) shape estimators. We find that noise bias depends sensitively on the particular shape estimator and measure of ensemble-average shape that is used, and properties of the galaxy that include redshift-dependent quantities such as size and luminosity. The source code for these studies is available online.[The documented software developed for the catalog-level studies are available in the open-source LSST DESC github repository https://github.com/LSSTDESC/WeakLensingDeblending. The software for analyzing one or two galaxies with user-defined parameters is in the open-source github repository https://github.com/ismael-mendoza/ShapeMeasurementFisherFormalism.]

79 ASTRONOMY AND ASTROPHYSICS↗

Operando synchrotron X-ray analysis of melt pool dynamics in an Al-Sn immiscible alloy

The melt flow in an Al-50vol.% Sn immiscible alloy, produced by single-track laser melting of Al and Sn elemental powders, was studied in real time. High-speed synchrotron X-ray imaging was used to track Al and Sn liquids’ movements, and also to examine elemental distributions in the laser tracks, complimented by electron microscopy after solidification. Key aspects, including melt pool geometry, keyhole instability, and flow dynamics (flow pattern and velocity), were examined using digital image analysis. Relatively deeper melt pools formed at 400 W and 300 mm/s exhibited greater stability, with smooth surfaces, consistent outward flow, and minor vortices near the keyhole. In contrast, shallower pools produced at higher scanning speeds (>500 mm/s) demonstrated greater instability with increased surface waviness, and stronger velocity fluctuations, leading to numerous micro-vortices and increased Al-Sn heterogeneity. Velocity scale estimations, supported by experimental observations, examined the roles of vapour pressure, Marangoni effect, buoyancy, inertial, and surface tension forces in the flow. The results revealed that vapour pressure and mechanical waves dominated at high scanning speeds (shallow pools), while Marangoni forces were equally significant in deep pools at lower speeds (300 mm/s). Buoyancy was found to have minimal impact in both cases. Furthermore, the interaction between inertial and surface tension forces played a critical role in determining the degree of waviness of the pools’ surfaces. These findings offer valuable insights into melt pool dynamics during laser processing of immiscible alloys and other metallic systems using elemental powders, and provide guidance for developing high-fidelity computational fluid dynamics models.

immiscible alloys↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

Quantitative Particle Analysis of Neptunium-237 Oxides: Optimization of MAMA Analysis for Modified Direct Denitration Products

The production of plutonium-238 through irradiation of neptunium-237 ( 237 Np) target materials for the use in radioisotope thermoelectric generators is paramount for continued deep space exploration. This work employs scanning electron microscopy to analyze 237 Np materials coupled with a well-developed image analysis framework (Morphological Analysis for Material Attribution, or MAMA) to determine the degree of micron-scale homogeneity in the materials. This work demonstrated how the quantification of particle characteristics can validate production materials and affirm the qualitative similarities observed in micrographs. The 237 Np oxide particle analysis determined that the materials from five production runs were quantitatively homogenous (significant at α = 0.05) in particle area, circularity, equivalent circular diameter, and ellipse aspect ratio, with two of the sampling dates having statistically significant different means for one of the four characteristics. Furthermore, these metrics not only confirm general homogeneity of the material but also expand the application of MAMA workflows to 237 Np materials, demonstrating the utility of MAMA analysis for a wider breadth of nuclear materials than previously reported. In the open literature, this study is the first time that these microanalytical techniques were applied to 237 Np materials to this degree.

MAMA↗

Large-Scale Trajectory Analysis via Feature Vectors

The explosion of both sensors and GPS-enabled devices has resulted in position/time data being the next big frontier for data analytics. However, many of the problems associated with large numbers of trajectories do not necessarily have an analog with many of the historic big-data applications such as text and image analysis. Modern trajectory analytics exploits much of the cutting-edge research in machine-learning, statistics, computational geometry and other disciplines. We will show that for doing trajectory analytics at scale, it is necessary to fundamentally change the way the information is represented through a feature-vector approach. We then demonstrate the ability to solve large trajectory analytics problems using this representation.

58 GEOSCIENCES↗

Fusing Quantitative-Phase Imaging with Airy Light- Sheet Microscopy

We report the integration of quantitative-phase imaging (QPI) with light-sheet (LS) fluorescent microscopy on to a standard inverted microscope that retains compatibility with microfluidics. QPI enables label-free imaging and number-density quantification of single cells and their organelles. Conversely, LS yields considerable speed and phototoxicity gains in quantifying the 4D dynamics of gene-encoded fluorescent biomarkers. We will detail the system design that relied on spatial light interferometry for QPI and an accelerating Airy- beam light-sheet for fluorescence, its performance, as well as results of a representative multivariate imaging analysis of single-cell metabolism.

imaging, lattice light sheet, Yarrowia lipolytica,↗

Understanding kinetics of defect annihilation in chemoepitaxy-directed self-assembly.

Directed self-assembly (DSA) of block copolymers (BCP) has attracted considerable interest from the semiconductor industry because it can achieve semiconductor-relevant structures with a relatively simple process and low cost. However, the self-assembling structures can become kinetically trapped into defective states, which greatly impedes the implementation of DSA in high-volume manufacturing. Understanding the kinetics of defect annihilation is crucial to optimizing the process and eventually eliminating defects in DSA. Such kinetic experiments, however, are not commonly available in academic laboratories. To address this challenge, we perform a kinetic study of chemoepitaxy DSA in a 300 mm wafer fab, where the complete defectivity information at various annealing conditions can be readily captured. Through extensive statistical analysis, we reveal the statistical model of defect annihilation in DSA for the first time. The annihilation kinetics can be well described by a power law model, indicating that all dislocations can be removed by sufficiently long annealing time. We further develop image analysis algorithms to analyze the distribution of dislocation size and configurations and discover that the distribution stays relatively constant over time. The defect distribution is determined by the role of the guiding stripe, which is found to stabilize the defects. Although this study is based on polystyrene-b-poly(methyl methacrylate) (PS-b-PMMA), we anticipate that these findings can be readily applied to other BCP platforms as well.

block copolymer↗

Methods—Kintsugi Imaging of Battery Electrodes: Distinguishing Pores from the Carbon Binder Domain using Pt Deposition

The mesostructure of porous electrodes used in lithium-ion batteries strongly influences cell performance. Accurate imaging of the distribution of phases in these electrodes would allow this relationship to be better understood through simulation. However, imaging the nanoscale features in these components is challenging. While scanning electron microscopy is able to achieve the required resolution, it has well established difficulties imaging porous media. This is because the flat imaging planes prepared using focused ion beam milling will intersect with the pores, which makes the images hard to interpret as the inside walls of the pores are observed. It is common to infiltrate porous media with resin prior to imaging to help resolve this issue, but both the nanoscale porosity and the chemical similarity of the resins to the battery materials undermine the utility of this approach for most electrodes. In this study, a technique is demonstrated which uses in situ infiltration of platinum to fill the pores and thus enhance their contrast during imaging. Reminiscent of the Japanese art of repairing cracked ceramics with precious metals, this technique is referred to as the kintsugi method. The images resulting from applying this technique to a conventional porous cathode are presented and then segmented using a multi-channel convolutional method. We show that while some cracks in active material particles were empty, others appear to be filled (perhaps with the carbon binder phase), which will have implications for the rate performance of the cell. Energy dispersive X-ray spectroscopy was used to validate the distribution of phases resulting from image analysis, which also suggested a graded distribution of the binder relative to the carbon additive. The equipment required to use the kintsugi method is commonly available in major research facilities and so we hope that this method will be rapidly adopted to improve the imaging of electrode materials and porous media in general.

25 ENERGY STORAGE↗

Large-scale analysis of structural brain asymmetries in schizophrenia via the ENIGMA consortium

Left–right asymmetry is an important organizing feature of the healthy brain that may be altered in schizophrenia, but most studies have used relatively small samples and heterogeneous approaches, resulting in equivocal findings. We carried out the largest case–control study of structural brain asymmetries in schizophrenia, with MRI data from 5,080 affected individuals and 6,015 controls across 46 datasets, using a single image analysis protocol. Asymmetry indexes were calculated for global and regional cortical thickness, surface area, and subcortical volume measures. Differences of asymmetry were calculated between affected individuals and controls per dataset, and effect sizes were meta-analyzed across datasets. Small average case–control differences were observed for thickness asymmetries of the rostral anterior cingulate and the middle temporal gyrus, both driven by thinner left-hemispheric cortices in schizophrenia. Analyses of these asymmetries with respect to the use of antipsychotic medication and other clinical variables did not show any significant associations. Assessment of age- and sex-specific effects revealed a stronger average leftward asymmetry of pallidum volume between older cases and controls. Case–control differences in a multivariate context were assessed in a subset of the data (N = 2,029), which revealed that 7% of the variance across all structural asymmetries was explained by case–control status. Subtle case–control differences of brain macrostructural asymmetry may reflect differences at the molecular, cytoarchitectonic, or circuit levels that have functional relevance for the disorder. Reduced left middle temporal cortical thickness is consistent with altered left-hemisphere language network organization in schizophrenia.

60 APPLIED LIFE SCIENCES↗

Using Ultrasound Image Augmentation and Ensemble Predictions to Prevent Machine-Learning Model Overfitting

Deep learning predictive models have the potential to simplify and automate medical imaging diagnostics by lowering the skill threshold for image interpretation. However, this requires predictive models that are generalized to handle subject variability as seen clinically. Here, we highlight methods to improve test accuracy of an image classifier model for shrapnel identification using tissue phantom image sets. Using a previously developed image classifier neural network—termed ShrapML—blind test accuracy was less than 70% and was variable depending on the training/test data setup, as determined by a leave one subject out (LOSO) holdout methodology. Introduction of affine transformations for image augmentation or MixUp methodologies to generate additional training sets improved model performance and overall accuracy improved to 75%. Further improvements were made by aggregating predictions across five LOSO holdouts. This was done by bagging confidences or predictions from all LOSOs or the top-3 LOSO confidence models for each image prediction. Top-3 LOSO confidence bagging performed best, with test accuracy improved to greater than 85% accuracy for two different blind tissue phantoms. This was confirmed by gradient-weighted class activation mapping to highlight that the image classifier was tracking shrapnel in the image sets. Overall, data augmentation and ensemble prediction approaches were suitable for creating more generalized predictive models for ultrasound image analysis, a critical step for real-time diagnostic deployment.

60 APPLIED LIFE SCIENCES↗

Training Ultrasound Image Classification Deep-Learning Algorithms for Pneumothorax Detection Using a Synthetic Tissue Phantom Apparatus

Ultrasound (US) imaging is a critical tool in emergency and military medicine because of its portability and immediate nature. However, proper image interpretation requires skill, limiting its utility in remote applications for conditions such as pneumothorax (PTX) which requires rapid intervention. Artificial intelligence has the potential to automate ultrasound image analysis for various pathophysiological conditions. Training models require large data sets and a means of troubleshooting in real-time for ultrasound integration deployment, and they also require large animal models or clinical testing. Here, we detail the development of a dynamic synthetic tissue phantom model for PTX and its use in training image classification algorithms. The model comprises a synthetic gelatin phantom cast in a custom 3D-printed rib mold and a lung mimicking phantom. When compared to PTX images acquired in swine, images from the phantom were similar in both PTX negative and positive mimicking scenarios. We then used a deep learning image classification algorithm, which we previously developed for shrapnel detection, to accurately predict the presence of PTX in swine images by only training on phantom image sets, highlighting the utility for a tissue phantom for AI applications.

Boice, Emily N. (ORCID:0000000171802842)↗