Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ice water content”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

WACCM6 Projections of Polar Mesospheric Cloud Abundance Over the 21st Century

Polar mesospheric clouds (PMC), or noctilucent clouds, can be observed over high latitudes with the naked eye from the ground or from space near the summer solstice. PMC are considered a direct and sensitive indicator of climate change and have been reported to appear more frequently in recent decades. How PMC will change in the future under the influence of natural variability and anthropogenic forcing is uncertain. In this study, we utilize model output from the Whole Atmosphere Community Climate Model under several shared socioeconomic pathway (SSP) scenarios and input the water vapor, temperature, and pressure information into a 0-d PMC model to project the trend and variation of PMC over the 21st century, and their relationship to future changes of temperature, water vapor, and the solar cycle. The 0-d model calculations indicate that PMC ice water content (IWC) will increase and PMC will extend to lower latitudes under high SSP scenarios. Under these scenarios, more mesospheric water vapor leads to an increased IWC of PMC over the polar region, and colder mesopause temperature leads to more PMC over the mid-latitudes. There is a significant anti-correlation between the solar cycle and PMC IWC over the 21st century, but the anti-correlation is not always significant on the decadal scale. Finally, methane oxidation in the stratosphere and water vapor entering from the troposphere are both responsible for future changes in mesospheric water vapor and thus PMC.

Polar Mesospheric Clouds↗

Implementation of A New Microwave Scattering Database and A Forward Model for Active Microwave Sensors in CRTM

Radiative transfer models are extensively used for the assimilation of satellite observations into NWP models as well as retrieving geophysical products from satellite measurements. CRTM is a community model developed by NOAA JCSDA and widely used for different purposes requiring RT calculations. CRTM requires bulk scattering lookup tables in order to perform all-sky RT calculations. However, the current CRTM lookup tables for microwave frequencies were generated based on the Mie theory by assuming spherical frozen particles. The scattering lookup tables generated using the DDA technique has shown to largely improve the RT scattering calculations in the MW region. This presentation targets (i) the implementation and validation of a DDA database that was originally developed for the ARTS RT model into CRTM, and (ii) developing the CRTM active sensor module that takes advantage of the backscattering coefficients computed using the DDA method. The DDA database only provides single scattering properties of different habits, while CRTM requires bulk scattering properties. The CRTM cloud coefficients were previously generated based on the effective radius for representing the size of the particles. However, effective radius is neither measurable nor provided by the NWP models, thus need to be estimated from other geophysical variables such as water content. Therefore, in addition to calculating the CRTM bulk scattering properties from the DDA single scattering database, the CRTM was also largely modified to use cloud water content (kg.m-3), instead of effective radius, for performing the interpolation over size/mass of the particles. CRTM already requires water content as input, thus no extra variables are required for performing scattering calculations using the new ARTS DDA database. The CRTM scattering modules search for effective radius in cloud coefficient files and will use the cloud water content if the effective radius dimension is not found in the cloud coefficient files. Figure 1 shows the CRTM simulated brightness temperatures computed using different cloud coefficients versus ATMS observed values over Hurricane Irma on September 7, 2017 at 18:00 UTC. We used all the cloud water content values included in ERA5 with default CRTM/DDA habits for water, rain, snow, ice, hail, and graupel. ERA5 does not provide separate water content values for ice, hail, and graupel, thus the ice water content values were divided between ice, hail, and graupel clouds similar to what was explained in the previous section. In channels with a frequency lower than 90 GHz, emission from water and rain clouds can compensate for cloud scattering so that cloud contaminated Tbs are larger than corresponding clear sky Tbs. The DDA simulations for channels 1-7 largely perform better than the Mie simulations. The DDA simulations show a mix of small negative and positive simulated minus observed values, while the Mie results show large negative biases. The weighting functions for some of the ATMS temperature sounding channels (channels 9-15) peak mostly above the clouds, therefore the measured Tbs become less sensitive to clouds so that the results of both Mie and DDA become very similar. The Mie lookup tables generate excessive scattering for channel 16, but not enough scattering for the water vapor channels. In the specific case of Hurricane Maria, the DDA lookup tables do not generate enough scattering for channel 16, but the DDA results are much more consistent with observations for water vapor channels than for channel 16. It should be noted that the results may vary if we use other habits to represent snow, hail, and graupel in the DDA simulations. Although these results clearly show the advantage of the DDA database over the Mie dataset, different error sources such as error in the observations, displacement of clouds in the ERA5 reanalysis, and also lack of convective clouds or in general errors in the input atmospheric and cloud profiles contribute to the differences between the simulated and observed values. Aside from the improvements in the simulations, a major advantage of the new dataset is a large number of habits that can be used to tune the data assimilation systems to perform well in different weather conditions.

Isaac Moradi↗

Cloud Uniformity Measurement from NASA's 2nd Fundamental Ice Crystal Icing Test Part 1 (Water Content & PSD)

This paper presents water content and particle measurements from the second Fundamental Ice Crystal Icing Physics test conducted in the NASA Propulsion Systems Laboratory. The water content measurements came from the Science Engineering Associates Multi-Element Probe and the Isokinetic Probe whereas the Artium Technologies, Inc. Phase Doppler Interferometer and High Speed Imaging instruments measured the particle size distribution. Ice particle accretion due to the ingestion of ice-crystals is attributed to numerous jet engine powerloss events. The NASA PSL is an altitude jet-engine test facility which has recently added a capability to inject ice particles into the flow. This work focuses on characterizing the icing cloud by traversing the instruments across the test section at four different conditions where velocity and water content were varied. For this test, the nozzle patterns were selected to make a uniform cloud in the center 6-inch diameter of the test section. Radial trends for the ice and water content measurements are presented and the melt ratio is calculated at the measurement locations. Particle size distributions are also presented. The measured water content, melt ratio, and particle size decreased moving out radially. Measured water content trends show uniformity to within 19.2% for the center 6 inches of the cloud, as intended. In addition, the total water content increased at centerline with velocity, whereas the melt ratio decreased.

Ice-Crystal Icing↗

Cloud Uniformity Measurements from NASA's 2nd Fundamental Ice Crystal Icing Test Part 1 (Water Content & PSD)

This paper presents water content and particle measurements from the second Fundamental Ice Crystal Icing Physics test conducted in the NASA Propulsion Systems Laboratory. The water content measurements came from the Science Engineering Associates Multi-Element Probe and the Isokinetic Probe whereas the Artium Technologies, Inc. Phase Doppler Interferometer and High Speed Imaging instruments measured the particle size distribution. Ice particle accretion due to the ingestion of ice-crystals is attributed to numerous jet engine powerloss events. The NASA PSL is an altitude jet-engine test facility which has recently added a capability to inject ice particles into the flow. This work focuses on characterizing the icing cloud by traversing the instruments across the test section at four different conditions where velocity and water content were varied. For this test, the nozzle patterns were selected to make a uniform cloud in the center 6-inch diameter of the test section. Radial trends for the ice and water content measurements are presented and the melt ratio is calculated at the measurement locations. Particle size distributions are also presented. The measured water content, melt ratio, and particle size decreased moving out radially. Measured water content trends show uniformity to within 19.2% for the center 6 inches of the cloud, as intended. In addition, the total water content increased at centerline with velocity, whereas the melt ratio decreased.

Ice-Crystal Icing↗

Spatial Analysis of Great Lakes Regional Icing Cloud Liquid Water Content

Abstract Clustering of cloud microphysical conditions, such as liquid water content (LWC) and drop size, can affect the rate and shape of ice accretion and the airworthiness of aircraft. Clustering may also degrade the accuracy of cloud LWC measurements from radars and microwave radiometers being developed by the government for remotely mapping icing conditions ahead of aircraft in flight. This paper evaluates spatial clustering of LWC in icing clouds using measurements collected during NASA research flights in the Great Lakes region. We used graphical and analytical approaches to describe clustering. The analytical approach involves determining the average size of clusters and computing a clustering intensity parameter. We analyzed flight data composed of 1-s-frequency LWC measurements for 12 periods ranging from 17.4 minutes (73 km) to 45.3 minutes (190 km) in duration. Graphically some flight segments showed evidence of consistency with regard to clustering patterns. Cluster intensity varied from 0.06, indicating little clustering, to a high of 2.42. Cluster lengths ranged from 0.1 minutes (0.6 km) to 4.1 minutes (17.3 km). Additional analyses will allow us to determine if clustering climatologies can be developed to characterize cluster conditions by region, time period, or weather condition. Introduction

Ryerson, Charles C.↗

The Calculated and Measured Performance Characteristics of a Heated-Wire Liquid-Water-Content Meter for Measuring Icing Severity

Ground tests have been made of an instrument which, when assembled in a more compact form for flight installation, could be used to obtain statistical flight data on the liquid-water content of icing clouds and to provide an indication of icing severity. The sensing element of the instrument consists of an electrically heated wire which is mounted in the air stream. The degree of cooling of the wire resulting from evaporation of the impinging water droplets is a measure. of the liquid-water content of the cloud. Determination of the value of the liquid-water content from the wire temperature at any instant requires a knowledge of the airspeed, altitude, and air temperature. An analysis was made of the temperature response of a heated wire exposed to an air stream containing water drops. Comparisons were made of the liquid-water content as measured with several heated wires and absorbent cylinders in an artificially produced cloud. For one of the wires, comparative tests were made with a rotating-disk icing-rate meter in an icing wind tunnel. From the test results, it was shown that an instrument for measuring the concentration of liquid water in an air stream can be built using an electrically heated wire of known temperatureresistance characteristics, and that the performance of such a device can be predicted using appropriate theory. Although an instrument in a form suitable for gathering statistical data in flight was not built, the practicability of constructing such an instrument was illustrated. The ground-test results indicated that a flight heated-wire instrument would be simple and durable, would respond rapidly to variations in liquid-water content, and could be used for the measurement of water content in clouds which are above freezing temperature, as well as in icing clouds.

Neel, Carr B.↗

An Investigation of Glaciated Cloud Capabilities in the NASA Glenn Icing Research Tunnel

In 2015 the FAA added Appendix D to Part 33 engine certification requirements that included Mixed Phase and Ice Crystal Icing to aircraft engine certification. Replicating the ice crystal environment that is seen in nature has proven to be a challenge, which multiple engine ground testing facilities and icing wind tunnels have achieved to varying degrees. The Icing Research Tunnel (IRT) at NASA Glenn has always been focused on super-cooled liquid water to produce FAA Part 23 and Part 25 regulations, targeting Appendix C and lately also Appendix O. However, due to a growing interest in the field of ice crystals and the high cost of operating engine icing facilities, the IRT staff have recently completed testing using the Multi-Element Sensor (also known as the multi-wire) to measure glaciated cloud conditions. Results indicate that turning off the heat to the nozzle air and water supply can create a stable, fully glaciated cloud in the test section for a small range of conditions: drop-size distribution values below 20 microns (median volumetric diameter), air temperatures as warm as -7 deg C, and airspeeds between 100 and 250 knots. These tests also revealed how varying the total temperature, airspeed, nozzle air pressure, and nozzle water pressure affect the glaciation of the IRT cloud.

ice water content↗

Improved Instrument for Detecting Water and Ice in Soil

An instrument measures electrical properties of relatively dry soils to determine their liquid water and/or ice contents. Designed as a prototype of instruments for measuring the liquid-water and ice contents of lunar and planetary soils, the apparatus could also be utilized for similar purposes in research and agriculture involving terrestrial desert soils and sands, and perhaps for measuring ice buildup on aircraft surfaces. This instrument is an improved version of the apparatus described in Measuring Low Concentrations of Liquid Water and Ice in Soil (NPO-41822), NASA Tech Briefs, Vol. 33, No. 2 (February 2009), page 22. The designs of both versions are based on the fact that the electrical behavior of a typical soil sample is well approximated by a network of resistors and capacitors in which resistances decrease and capacitances increase (and the magnitude and phase angle of impedance changes accordingly) with increasing water content. The previous version included an impedance spectrometer and a jar into which a sample of soil was placed. Four stainless-steel screws at the bottom of the jar were used as electrodes of a fourpoint impedance probe connected to the spectrometer. The present instrument does not include a sample jar and can be operated without acquiring or handling samples. Its impedance probe consists of a compact assembly of electrodes housed near the tip of a cylinder. The electrodes protrude slightly from the cylinder (see Figure 1). In preparation for measurements, the cylinder is simply pushed into the ground to bring the soil into contact with the electrodes.

Buehler, Martin↗

Statistical Survey of Icing Data Measured on Scheduled Airline Flights over the United States and Canada from November 1951 to June 1952

A statistical survey and a preliminary analysis are made of icing data collected from scheduled flights over the United States and Canada from November 1951 to June 1952 by airline aircraft equipped with NACA pressure-type icing-rate meters. This interim report presents information obtained from a continuing program sponsored by the NACA with the cooperation of the airlines. An analysis of over 600 icing encounters logged by three airlines operating in the United States, one operating in Canada and one operating up the coast to Alaska, is presented. The icing conditions encountered provided relative frequencies of many icing-cloud variables, such as horizontal extent, vertical thickness, temperatures, icing rate, liquid-water content, and total ice accumulation. Liquid-water contents were higher than data from earlier research flights in layer-type clouds but slightly lower than previous data from cumulus clouds. Broken-cloud conditions, indicated by intermittent icing, accounted for nearly one-half of all the icing encounters. About 90 percent of the encounters did not exceed a distance of 120 miles, and continuous icing did not exceed 50 miles for 90 percent of the unbroken conditions. Icing cloud thicknesses measured during climbs and descents were less than 4500 feet for 90 percent of the vertical cloud traverses.

Perkins, Porter J↗

Isokinetic Probe Total Water Content Measurements in the NASA Icing Research Tunnel with Supercooled Large Drop Conditions

An Isokinetic Total Water Content Evaporator (IKP2) was used to measure liquid water content (LWC) in the NASA Icing Research Tunnel (IRT) with spray conditions that ranged in LWC and cloud drop size spectra as characterized by the median volumetric diameter (MVD). The IKP2 measurements were made as part of an international collaborative effort to investigate the measurement of supercooled large drop (SLD) conditions in several icing wind tunnels. This report focuses on the IKP2 and background water vapor (BWV) measurements made within the NASA IRT during the October 2017 test entry. The IKP2 TWC results are compared to the IRT LWC calibration values for a range of LWC and MVD values. The IRT LWC calibration is based on measurements from a multi-element hot-wire probe. In general, the IKP2 TWC values were approximately 9% greater than the IRT LWC calibration values over a range of LWC from 0.4 g/m3 to 3.0 g/m3. The ratio of IKP2 TWC to IRT LWC calibration ranged from approximately 0.9 to 1.27 over a range of MVD from 15µm to 460 µm. Comparisons of this data set to IKP2 data from a 2014 IRT test entry show similar results in the regions where overlaps occurred. The results support the theory and observations of water mass loss from hot-wire TWC sensors when subjected to large MVD conditions.

Icing cloud instruments↗

Isokinetic Probe Total Water Content Measurements in the NASA Icing Research Tunnel with Supercooled Large Drop Conditions

An Isokinetic Total Water Content Evaporator (IKP2) was used to measure liquid water content (LWC) in the NASA Icing Research Tunnel (IRT) with spray conditions that ranged in LWC and cloud drop size spectra as characterized by the median volumetric diameter (MVD). The IKP2 measurements were made as part of an international collaborative effort to investigate the measurement of supercooled large drop (SLD) conditions in several icing wind tunnels. This report focuses on the IKP2 and background water vapor (BWV) measurements made within the NASA IRT during the October 2017 test entry. The IKP2 TWC results are compared to the IRT LWC calibration values for a range of LWC and MVD values. The IRT LWC calibration is based on measurements from a multi-element hot-wire probe. In general, the IKP2 TWC values were approximately 9% greater than the IRT LWC calibration values over a range of LWC from 0.4 g/m3 to 3.0 g/m3. The ratio of IKP2 TWC to IRT LWC calibration ranged from approximately 0.9 to 1.27 over a range of MVD from 15m to 460 m. Comparisons of this data set to IKP2 data from a 2014 IRT test entry show similar results in the regions where overlaps occurred. The results support the theory and observations of water mass loss from hot-wire TWC sensors when subjected to large MVD conditions.

o Aircraft Icing↗

Isokinetic Probe Total Water Content Measurements in the NASA Icing Research Tunnel with Supercooled Large Drop Conditions

An Isokinetic Total Water Content Evaporator (IKP2) was used to measure liquid water content (LWC) in the NASA Icing Research Tunnel (IRT) with spray conditions that ranged in LWC and cloud drop size spectra as characterized by the median volumetric diameter (MVD). The IKP2 measurements were made as part of an international collaborative effort to investigate the measurement of supercooled large drop (SLD) conditions in several icing wind tunnels. This report focuses on the IKP2 and background water vapor (BWV) measurements made within the NASA IRT during the October 2017 test entry. The IKP2 TWC results are compared to the IRT LWC calibration values for a range of LWC and MVD values. The IRT LWC calibration is based on measurements from a multi-element hot-wire probe. In general, the IKP2 TWC values were approximately 9% greater than the IRT LWC calibration values over a range of LWC from 0.4 g/m3 to 3.0 g/m3. The ratio of IKP2 TWC to IRT LWC calibration ranged from approximately 0.9 to 1.27 over a range of MVD from 15um to 460 um. Comparisons of this data set to IKP2 data from a 2014 IRT test entry show similar results in the regions where overlaps occurred. The results support the theory and observations of water mass loss from hot-wire TWC sensors when subjected to large MVD conditions.

o Aircraft Icing↗

Ice Particle Impact on Cloud Water Content Instrumentation

Determining the total amount of water contained in an icing cloud necessitates the measurement of both the liquid droplets and ice particles. One commonly accepted method for measuring cloud water content utilizes a hot wire sensing element, which is maintained at a constant temperature. In this approach, the cloud water content is equated with the power required to keep the sense element at a constant temperature. This method inherently assumes that impinging cloud particles remain on the sensing element surface long enough to be evaporated. In the case of ice particles, this assumption requires that the particles do not bounce off the surface after impact. Recent tests aimed at characterizing ice particle impact on a thermally heated wing section, have raised questions about the validity of this assumption. Ice particles were observed to bounce off the heated wing section a very high percentage of the time. This result could have implications for Total Water Content sensors which are designed to capture ice particles, and thus do not account for bouncing or breakup of ice particles. Based on these results, a test was conducted to investigate ice particle impact on the sensing elements of the following hot-wire cloud water content probes: (1) Nevzorov Total Water Content (TWC)/Liquid Water Content (LWC) probe, (2) Science Engineering Associates TWC probe, and (3) Particle Measuring Systems King probe. Close-up video imaging was used to study ice particle impact on the sensing element of each probe. The measured water content from each probe was also determined for each cloud condition. This paper will present results from this investigation and attempt to evaluate the significance of ice particle impact on hot-wire cloud water content measurements.

Emery, Edward F.↗

An Assessment of the Icing Blade and the SEA Multi-Element Sensor for Liquid Water Content Calibration of the NASA GRC Icing Research Tunnel

The Icing Research Tunnel at NASA Glenn has recently switched to from using the Icing Blade to using the SEA Multi-Element Sensor (also known as the multi-wire) for its calibration of cloud liquid water content. In order to perform this transition, tests were completed to compare the Multi-Element Sensor to the Icing Blade, particularly with respect to liquid water content, airspeed, and drop size. The two instruments were found to compare well for the majority of Appendix C conditions. However, it was discovered that the Icing Blade under-measures when the conditions approach the Ludlam Limit. This paper also describes data processing procedures for the Multi-Element Sensor in the IRT, including collection efficiency corrections, mounting underneath a splitter plate, and correcting for a jump in the compensation wire power. Further data is presented to describe the repeatability of the IRT with the Multi-Element sensor, health-monitoring checks for the instrument, and a sensing-element configuration comparison.

multi-element sensor↗

An Assessment of the Icing Blade and the SEA Multi-Element Sensor for Liquid Water Content Calibration of the NASA GRC Icing Research Tunnel

The Icing Research Tunnel at NASA Glenn has recently switched from using the Icing Blade to using the SEA Multi-Element Sensor (also known as the multi-wire) for its calibration of cloud liquid water content. In order to peform this transition, tests were completed to compare the Multi-Element Sensor to the Icing Blade, particularly with respect to liquid water content, airspeed, and drop size. The two instruments were found to compare well for the majority of Appendix C conditions. However, it was discovered that the Icing Blade under-measures when the conditions approach the Ludlam Limit. This paper also describes data processing procedures for the Multi-Element Sensor in the IRT, including collision efficiency corrections, mounting underneath a splitter plate, and correcting for a jump in the compensation wire power. Further data is presented to describe the repeatability of the IRT with the Multi-Element Sensor, health-monitoring checks for the instrument, and a sensing-element configuration comparison. Ultimately these tests showed that in the IRT, the multi-wire is a better instrument for measuring cloud liquid water content than the blade.

aircraft icing↗

An Assessment of the SEA Multi-Element Sensor for Liquid Water Content Calibration of the NASA GRC Icing Research Tunnel

The NASA Glenn Icing Research tunnel has been using an Icing Blade technique to measure cloud liquid water content (LWC) since 1980. The IRT conducted tests with SEA Multi-Element sensors from 2009 to 2011 to assess their performance in measuring LWC. These tests revealed that the Multi-Element sensors showed some significant advantages over the Icing Blade, particularly at higher water contents, higher impingement rates, and large drop sizes. Results of these and other tests are presented here.

multi-wire↗