Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ITERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A path to stable low-torque plasma operation in ITER with test blanket modules

New experiments in the low-torque ITER Q = 10 scenario on DIII-D demonstrate that n = 1 magnetic fields from a single row of ex-vessel control coils enable operation at ITER performance metrics in the presence of applied non-axisymmetric magnetic fields from a test blanket module (TBM) mock-up coil. With n = 1 compensation, operation below the ITER-equivalent injected torque is successful at three times the ITER equivalent toroidal magnetic field ripple for a pair of TBMs in one equatorial port, whereas the uncompensated TBM field leads to rotation collapse, loss of H-mode and plasma current disruption. In companion experiments at high plasma beta, where the n = 1 plasma response is enhanced, uncorrected TBM fields degrade energy confinement and the plasma angular momentum while increasing fast ion losses; however, disruptions are not routinely encountered owing to increased levels of injected neutral beam torque. In this regime, n = 1 field compensation leads to recovery of a dominant fraction of the TBM-induced plasma pressure and rotation degradation, and an 80% reduction in the heat load to the first wall. These results show that the n = 1 plasma response plays a dominant role in determining plasma stability, and that n = 1 field compensation alone not only recovers most of the impact on plasma performance of the TBM, but also protects the first wall from potentially damaging heat flux. Despite these benefits, plasma rotation braking from the TBM fields cannot be fully recovered using standard error field control. Lastly, given the uncertainty in extrapolation of these results to the ITER configuration, it is prudent to design the TBMs with as low a ferromagnetic mass as possible without jeopardizing the TBM mission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ripple-induced neoclassical toroidal viscous torque in Augmented-First Plasma operation phase in ITER

Abstract A systematic calculation is performed on the ripple-induced neoclassical toroidal viscous (NTV) torque for new ITER scenarios designed for the Augmented-First Plasma (A-FP) operation phase with the full tungsten wall, where the plasma-wall gap is varied in view of mitigating the impact of tungsten wall-plasma interactions. The torque calculation includes drift kinetic response of the plasma thermal and energetic particles to the n = 18 ( n is the toroidal harmonic number) ripple field. For the plasma scenario with ~45 cm plasma-wall gap at the outboard mid-plane and considering the corrected ripple level of 0.17% by the ferritic steel inserts, the computed net NTV torque acting on the plasma column is in the sub-Nm level. However, with decreasing the plasma-wall gap, the computed net NTV torque can reach a level comparable to that produced by the neutral-beam momentum injection in ITER. Ripple correction by ferritic inserts reduces the net torque by a factor of 3.3 for all the three A-FP scenarios considered. The n ω d = l ω b (with ω d and ω b being the toroidal precession and bounce frequencies of trapped particles, respectively, and l an integer number) type of resonance-enhancement of the NTV torque, due to thermal particles, is found to be weak in ITER despite high- n of 18. The same also holds for the ITER 10 MA steady state scenario from the D-T operation phase, where the aforementioned resonance associated with fusion-born alphas is also included. The ripple-induced NTV torque is well below that produced by the resonant magnetic perturbation applied for controlling the type-I edge-localized mode in ITER.

ITER↗

Error field predictability and consequences for ITER

Abstract ITER coil tolerances are re-evaluated using the modern understanding of coupling to least-stable plasma modes and an updated center-line-traced model of ITER’s coil windings. This reassessment finds the tolerances to be conservative through a statistical, linear study of n = 1 error fields (EFs) due to tilted, shifted misplacements and nominal windings of central solenoid and poloidal field coils within tolerance. We also show that a model-based correction scheme remains effective even when metrology quality is sub-optimal, and compare this to projected empirical correction schemes. We begin with an analysis of the necessity of error field correction (EFC) for daily operation in ITER using scalign laws for the EF penetration threshold. We then consider the predictability of EF dominant mode overlap across early planned ITER scenarios and, as measuring EFs in high power scenarios can pose risks to the device, the potential for extrapolation to the ITER Baseline Scenario (IBS). We find that carefully designing a scenario matching currents proportionally to those of the IBS is far more important than plasma shape or profiles in accurately measuring an optimal correction current set.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Testing and modeling of diffusion bonded prototype optical windows under ITER conditions

Glass-metal joints are a part of ITER optical diagnostics windows. These joints must be leak tight for the safety (presence of tritium in ITER) and to preserve the vacuum. They must also withstand the ITER environment: temperatures up to 220 deg.C and fast neutron fluxes of {approx}3.10{sup 9} n/cm{sup 2}.s. At the moment, little information is available about glass-metal joints suitable for ITER. Therefore, we performed mechanical and thermal tests on some prototypes of an aluminium diffusion bonded optical window. Finite element modeling with Abaqus code was used to understand the experimental results. The prototypes were helium leaking probably due to very tiny cracks in the interaction layer between the steel and the aluminium. However, they were all able to withstand a thermal cycling test up to 200 deg. C; no damage could be seen after the tests by visual inspection. The prototypes successfully passed push-out test with a 500 N load. During the destructive push-out tests the prototypes broke at a 6-12 kN load between the aluminium layer and the steel or the glass, depending on the surface quality of the glass. The microanalysis of the joints has also been performed. The finite element modeling of the push-out tests is in a reasonable agreement with the experiments. According to the model, the highest thermal stress is created in the aluminium layer. Thus, the aluminium joint seems to be the weakest part of the prototypes. If this layer is improved, it will probably make the prototype helium leak tight and as such, a good ITER window candidate. (authors)

42 ENGINEERING↗

Verification Testing of ITER Nb 3 Sn Strand at the NHMFL

The large amount of Nb 3 Sn superconducting wire needed by ITER presents a significant challenge to ensure that all wires adhere to ITER specifications. The National High Magnetic Field Laboratory, USA performed verification tests for Nb 3 Sn strands used in ITER TF magnets. Converting a research laboratory into a large quantity testing facility presented many challenges in developing standard operating procedures for all the verification tests. Verification tests required by ITER include: unreacted-chrome-plated strand diameter, twist pitch and twist direction, chrome-plating thickness, unreacted-chrome-plated strand Cu-to-non-Cu volume ratio, residual resistivity ratio of Cr-plated strand (RRR), critical current at 4.22 K and 12 T (I c ), resistive transition index at 4.22 K and 12 T (n-value), and hysteresis loss per strand unit volume at 4.22 K over a ±3 T cycle. Additionally, due to the brittle nature of Nb 3 Sn superconducting wire, some samples were damaged in a controlled manner to explore the negative extremes of damage due to sample handling. Finally, we successfully completed the verification tests of ITER TF Nb 3 Sn strands made by US vendors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Information-theoretic discrepancy based iterative reconstructions (IDIR) for polychromatic x-ray tomography

Purpose: X-ray photons generated from a typical x-ray source for clinical applications exhibit a broad range of wavelengths, and the interactions between individual particles and biological substances depend on particles' energy levels. Most existing reconstruction methods for transmission tomography, however, neglect this polychromatic nature of measurements and rely on the monochromatic approximation. In this study, we developed a new family of iterative methods that incorporates the exact polychromatic model into tomographic image recovery, which improves the accuracy and quality of reconstruction.Methods: The generalized information-theoretic discrepancy (GID) was employed as a new metric for quantifying the distance between the measured and synthetic data. By using special features of the GID, the objective function for polychromatic reconstruction which contains a double integral over the wavelength and the trajectory of incident x-rays was simplified to a paraboloidal form without using the monochromatic approximation. More specifically, the original GID was replaced with a surrogate function with two auxiliary, energy-dependent variables. Subsequently, the alternating minimization technique was applied to solve the double minimization problem. Based on the optimization transfer principle, the objective function was further simplified to the paraboloidal equation, which leads to a closed-form update formula. Numerical experiments on the beam-hardening correction and material-selective reconstruction were conducted to compare and assess the performance of conventional methods and the proposed algorithms.Results: The authors found that the GID determines the distance between its two arguments in a flexible manner. In this study, three groups of GIDs with distinct data representations were considered. The authors demonstrated that one type of GIDs that comprises “raw” data can be viewed as an extension of existing statistical reconstructions; under a particular condition, the GID is equivalent to the Poisson log-likelihood function. The newly proposed GIDs of the other two categories consist of log-transformed measurements, which have the advantage of imposing linearized penalties over multiple discrepancies. For all proposed variants of the GID, the aforementioned strategy was used to obtain a closed-form update equation. Even though it is based on the exact polychromatic model, the derived algorithm bears a structural resemblance to conventional methods based on the monochromatic approximation. The authors named the proposed approach as information-theoretic discrepancy based iterative reconstructions (IDIR). In numerical experiments, IDIR with raw data converged faster than previously known statistical reconstruction methods. IDIR with log-transformed data exhibited superior reconstruction quality and faster convergence speed compared with conventional methods and their variants.Conclusions: The authors' new framework for tomographic reconstruction allows iterative inversion of the polychromatic data model. The primary departure from the traditional iterative reconstruction was the employment of the GID as a new metric for quantifying the inconsistency between the measured and synthetic data. The proposed methods outperformed not only conventional methods based on the monochromatic approximation but also those based on the polychromatic model. The authors have observed that the GID is a very flexible means to design an objective function for iterative reconstructions. Hence, the authors expect that the proposed IDIR framework will also be applicable to other challenging tasks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Iterative image-domain decomposition for dual-energy CT

Purpose: Dual energy CT (DECT) imaging plays an important role in advanced imaging applications due to its capability of material decomposition. Direct decomposition via matrix inversion suffers from significant degradation of image signal-to-noise ratios, which reduces clinical values of DECT. Existing denoising algorithms achieve suboptimal performance since they suppress image noise either before or after the decomposition and do not fully explore the noise statistical properties of the decomposition process. In this work, the authors propose an iterative image-domain decomposition method for noise suppression in DECT, using the full variance-covariance matrix of the decomposed images. Methods: The proposed algorithm is formulated in the form of least-square estimation with smoothness regularization. Based on the design principles of a best linear unbiased estimator, the authors include the inverse of the estimated variance-covariance matrix of the decomposed images as the penalty weight in the least-square term. The regularization term enforces the image smoothness by calculating the square sum of neighboring pixel value differences. To retain the boundary sharpness of the decomposed images, the authors detect the edges in the CT images before decomposition. These edge pixels have small weights in the calculation of the regularization term. Distinct from the existing denoising algorithms applied on the images before or after decomposition, the method has an iterative process for noise suppression, with decomposition performed in each iteration. The authors implement the proposed algorithm using a standard conjugate gradient algorithm. The method performance is evaluated using an evaluation phantom (Catphan©600) and an anthropomorphic head phantom. The results are compared with those generated using direct matrix inversion with no noise suppression, a denoising method applied on the decomposed images, and an existing algorithm with similar formulation as the proposed method but with an edge-preserving regularization term. Results: On the Catphan phantom, the method maintains the same spatial resolution on the decomposed images as that of the CT images before decomposition (8 pairs/cm) while significantly reducing their noise standard deviation. Compared to that obtained by the direct matrix inversion, the noise standard deviation in the images decomposed by the proposed algorithm is reduced by over 98%. Without considering the noise correlation properties in the formulation, the denoising scheme degrades the spatial resolution to 6 pairs/cm for the same level of noise suppression. Compared to the edge-preserving algorithm, the method achieves better low-contrast detectability. A quantitative study is performed on the contrast-rod slice of Catphan phantom. The proposed method achieves lower electron density measurement error as compared to that by the direct matrix inversion, and significantly reduces the error variation by over 97%. On the head phantom, the method reduces the noise standard deviation of decomposed images by over 97% without blurring the sinus structures. Conclusions: The authors propose an iterative image-domain decomposition method for DECT. The method combines noise suppression and material decomposition into an iterative process and achieves both goals simultaneously. By exploring the full variance-covariance properties of the decomposed images and utilizing the edge predetection, the proposed algorithm shows superior performance on noise suppression with high image spatial resolution and low-contrast detectability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-93: Improved Imaging Quality for Multislice Helical CT Via Sparsity Regularized Iterative Image Reconstruction Method Based On Tensor Framelet

Purpose: Inspired by compressive sensing, sparsity regularized iterative reconstruction method has been extensively studied. However, its utility pertinent to multislice helical 4D CT for radiotherapy with respect to imaging quality, dose, and time has not been thoroughly addressed. As the beginning of such an investigation, this work carries out the initial comparison of reconstructed imaging quality between sparsity regularized iterative method and analytic method through static phantom studies using a state-of-art 128-channel multi-slice Siemens helical CT scanner. Methods: In our iterative method, tensor framelet (TF) is chosen as the regularization method for its superior performance from total variation regularization in terms of reduced piecewise-constant artifacts and improved imaging quality that has been demonstrated in our prior work. On the other hand, X-ray transforms and its adjoints are computed on-the-fly through GPU implementation using our previous developed fast parallel algorithms with O(1) complexity per computing thread. For comparison, both FDK (approximate analytic method) and Katsevich algorithm (exact analytic method) are used for multislice helical CT image reconstruction. Results: The phantom experimental data with different imaging doses were acquired using a state-of-art 128-channel multi-slice Siemens helical CT scanner. The reconstructed image quality was compared between TF-based iterative method, FDK and Katsevich algorithm with the quantitative analysis for characterizing signal-to-noise ratio, image contrast, and spatial resolution of high-contrast and low-contrast objects. Conclusion: The experimental results suggest that our tensor framelet regularized iterative reconstruction algorithm improves the helical CT imaging quality from FDK and Katsevich algorithm for static experimental phantom studies that have been performed.

60 APPLIED LIFE SCIENCES↗

Sci—Thur PM: Imaging — 04: An iterative triple energy window (TEW) approach to cross talk correction in quantitative small animal Tc99m and In111 SPECT

Dual isotope SPECT allows simultaneous measurement of two different tracers in vivo. With In111 (emission energies of 171keV and 245keV) and Tc99m (140keV), quantification of Tc99m is degraded by cross talk from the In111 photons that scatter and are detected at an energy corresponding to Tc99m. TEW uses counts recorded in two narrow windows surrounding the Tc99m primary window to estimate scatter. Iterative TEW corrects for the bias introduced into the TEW estimate resulting from un-scattered counts detected in the scatter windows. The contamination in the scatter windows is iteratively estimated and subtracted as a fraction of the scatter-corrected primary window counts. The iterative TEW approach was validated with a small-animal SPECT/CT camera using a 2.5mL plastic container holding thoroughly mixed Tc99m/In111 activity fractions of 0.15, 0.28, 0.52, 0.99, 2.47 and 6.90. Dose calibrator measurements were the gold standard. Uncorrected for scatter, the Tc99m activity was over-estimated by as much as 80%. Unmodified TEW underestimated the Tc99m activity by 13%. With iterative TEW corrections applied in projection space, the Tc99m activity was estimated within 5% of truth across all activity fractions above 0.15. This is an improvement over the non-iterative TEW, which could not sufficiently correct for scatter in the 0.15 and 0.28 phantoms.

60 APPLIED LIFE SCIENCES↗

SU-F-I-49: Vendor-Independent, Model-Based Iterative Reconstruction On a Rotating Grid with Coordinate-Descent Optimization for CT Imaging Investigations

Purpose: Iterative reconstruction methods show promise for improving image quality and lowering the dose in helical CT. We aim to develop a novel model-based reconstruction method that offers potential for dose reduction with reasonable computation speed and storage requirements for vendor-independent reconstruction from clinical data on a normal desktop computer. Methods: In 2012, Xu proposed reconstructing on rotating slices to exploit helical symmetry and reduce the storage requirements for the CT system matrix. Inspired by this concept, we have developed a novel reconstruction method incorporating the stored-system-matrix approach together with iterative coordinate-descent (ICD) optimization. A penalized-least-squares objective function with a quadratic penalty term is solved analytically voxel-by-voxel, sequentially iterating along the axial direction first, followed by the transaxial direction. 8 in-plane (transaxial) neighbors are used for the ICD algorithm. The forward problem is modeled via a unique approach that combines the principle of Joseph’s method with trilinear B-spline interpolation to enable accurate reconstruction with low storage requirements. Iterations are accelerated with multi-CPU OpenMP libraries. For preliminary evaluations, we reconstructed (1) a simulated 3D ellipse phantom and (2) an ACR accreditation phantom dataset exported from a clinical scanner (Definition AS, Siemens Healthcare). Image quality was evaluated in the resolution module. Results: Image quality was excellent for the ellipse phantom. For the ACR phantom, image quality was comparable to clinical reconstructions and reconstructions using open-source FreeCT-wFBP software. Also, we did not observe any deleterious impact associated with the utilization of rotating slices. The system matrix storage requirement was only 4.5GB, and reconstruction time was 50 seconds per iteration. Conclusion: Our reconstruction method shows potential for furthering research in low-dose helical CT, in particular as part of our ongoing development of an acquisition/reconstruction pipeline for generating images under a wide range of conditions. Our algorithm will be made available open-source as “FreeCT-ICD”. NIH U01 CA181156; Disclosures (McNitt-Gray): Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP2-12: The Effect of Iterative Reconstruction and CT Tube Voltage On Hounsfield Unit Values of Iodinated Contrast

Purpose: To investigate the effects of changing iterative reconstruction strength and tube voltage on Hounsfield Unit (HU) values of varying concentrations of Iodinated contrast medium in a phantom. Method: Iodinated contrast (Omnipaque 300, GE Healthcare, Princeton NJ) was diluted with distilled water to concentrations of 0.6, 0.9, 1.8, 3.6, 7.2, and 10.8 mg/mL of Iodine. The solutions were scanned in a patient equivalent water phantom on two MDCT scanners: VCT 64 slice (GE Medical Systems, Waukesha, WI) and an Aquilion One 320 slice scanner (Toshiba America Medical Systems, Tustin CA). The phantom was scanned at 80, 100, 120, 140 kV using 400, 255, 180, and 130 mAs, respectively, for the VCT scanner, and 80, 100, 120, and 135 kV using 400, 250, 200, and 150 mAs, respectively, on the Aquilion One. Images were reconstructed at 2.5 mm (VCT) and 0.5 mm (Aquilion One). The VCT images were reconstructed using Advanced Statistical Iterative Reconstruction (ASIR) at 6 different strengths: 0%, 20%, 40%, 60%, 80%, and 100%. Aquilion One images were reconstructed using Adaptive Iterative Dose Reduction (AIDR) at 4 strengths: no AIDR, Weak AIDR, Standard AIDR, and Strong AIDR. Regions of interest (ROIs) were drawn on the images to measure the HU values and standard deviations of the diluted contrast. Second order polynomials were used to fit the HU values as a function of Iodine concentration. Results: For both scanners, there was no significant effect of changing the iterative reconstruction strength. The polynomial fits yielded goodness-of-fit (R2) values averaging 0.997. Conclusion: Changing the strength of the iterative reconstruction has no significant effect on the HU values of Iodinated contrast in a tissue-equivalent phantom. Fit values of HU vs Iodine concentration are useful in quantitative imaging protocols such as the determination of cardiac output from time-density curves in the main pulmonary artery.

60 APPLIED LIFE SCIENCES↗

Behaviors of impurity in ITER plasma with standard type I ELMy H-mode and steady-state scenarios

Self-consistent simulations of impurity behaviors in ITER plasmas in standard Type I ELMy H-mode and steady-state scenarios are investigated using 1.5D BALDUR integrated predictive modeling code. In these simulations, the plasma core transports, including electron and ion thermal, hydrogenic and impurity transports, are predicted using a linear combination of anomalous and neoclassical transports. An anomalous transport is calculated using a theory-based Multimode (MMM95) model; while the neoclassical transport is calculated using NCLASS model. The temperature and density boundary conditions are described at the top of the pedestal. Two different models for hydrogenic and impurity boundary density conditions are considered. The first model is called a 'static boundary density model,' in which the hydrogenic and impurity densities at the boundary are fixed. For the second model, called a 'dynamic boundary density model,' the hydrogenic and impurity densities at the boundary are assumed to be a large fraction of its line-averaged density. For simplicity, the pedestal temperature is assumed to be a constant in all simulations. The combination of a core transport model together with the boundary density models is used to simulate the time evolution of plasma current, temperature, and density profiles for ITER plasmas in standard type I ELMy H-mode and steady-state scenarios. As a result, the behaviors of impurity in ITER plasmas can be investigated. It is found in both ITER scenarios that the total amount of impurity, including beryllium and helium, in plasma core increases rapidly in early state and reaches a steady-state value. The level of impurity content in the steady state depends sensitively on the impurity boundary conditions. The effective charge at the edge is found to be about 1.4 and 1.1 using a static boundary density model and a dynamic boundary density model, respectively. It is also found that the hydrogenic and impurity transports in ITER plasmas for both scenarios is dominated by the kinetic ballooning modes, while the ITG and TEM modes provide the largest contributions for both thermal transports in most of region. In addition, a sensitivity study is carried out to investigate the impacts of pedestal temperature, pedestal density and line-averaged density on the impurity behaviors. It is found that increasing the pedestal temperature results in a reduction of the impurity content. On the other hand, increasing the pedestal density, line-averaged density or impurity influx result in an increase of the impurity content.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Combining Sparse Approximate Factorizations with Mixed-precision Iterative Refinement

The standard LU factorization-based solution process for linear systems can be enhanced in speed or accuracy by employing mixed-precision iterative refinement. Most recent work has focused on dense systems. We investigate the potential of mixed-precision iterative refinement to enhance methods for sparse systems based on approximate sparse factorizations. In doing so, we first develop a new error analysis for LU- and GMRES-based iterative refinement under a general model of LU factorization that accounts for the approximation methods typically used by modern sparse solvers, such as low-rank approximations or relaxed pivoting strategies. We then provide a detailed performance analysis of both the execution time and memory consumption of different algorithms, based on a selected set of iterative refinement variants and approximate sparse factorizations. Our performance study uses the multifrontal solver MUMPS, which can exploit block low-rank factorization and static pivoting. We evaluate the performance of the algorithms on large, sparse problems coming from a variety of real-life and industrial applications showing that mixed-precision iterative refinement combined with approximate sparse factorization can lead to considerable reductions of both the time and memory consumption.

97 MATHEMATICS AND COMPUTING↗

Cold Test Facility for the ITER Central Solenoid Coils

The United States, along with the European Union, Russia, Japan, China. South Korea and India, is a collaborative partner in the design, construction and operation of the ITER International Tokamak which will be located a Cadarache, France. One component of the US in kind contribution to the project is the Central Solenoid System for the tokamak magnet system. The Central Solenoid System is a massive assembly 4.4 meters outside diameter, 18.8 meters high and weighing ~ 1,000 tons. Operating conditions (not simultaneous) are 45kA and 13 T with a maximum field ramp rate of 1.3 T/s producing a maximum flux swing of 277 V s. This combination of performance parameters make the ITER Central Solenoid one the most challenging magnet system ever built Using CICC provide by Japan, the US will deliver the final CS System by fabricating the magnet from six (6) separate 100 ton coils supported and restrained by an external structure. Part of the US responsibilities in delivering this magnet system to the ITER International Organization is to acceptance test each Central Solenoid Coil separately at operating (4K) temperature. The principal acceptance test objectives are coil leak tightness, insulation integrity and overall coil joint quality. Peak test field and test current are reduced without field contributions from adjacent coils and practical installation considerations. This paper will describe an ITER Central Solenoid Cold Test Facility study undertaken by the National High Magnetic Field Laboratory at Florida State University and the United States ITER Project Office at Oak Ridge, TN.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experiments on water detritiation and cryogenic distillation at TLK; Impact on ITER fuel cycle subsystems interfaces

The ITER Isotope Separation System (ISS) and Water Detritiation System (WDS) should be integrated in order to reduce potential chronic tritium emissions from the ISS. This is achieved by routing the top (protium) product from the ISS to a feed point near the bottom end of the WDS Liquid Phase Catalytic Exchange (LPCE) column. This provides an additional barrier against ISS emissions and should mitigate the memory effects due to process parameter fluctuations in the ISS. To support the research activities needed to characterize the performances of various components for WDS and ISS processes under various working conditions and configurations as needed for ITER design, an experimental facility called TRENTA representative of the ITER WDS and ISS protium separation column, has been commissioned and is in operation at TLK The experimental program on TRENTA facility is conducted to provide the necessary design data related to the relevant ITER operating modes. The operation availability and performances of ISS-WDS have impact on ITER fuel cycle subsystems with consequences on the design integration. The preliminary experimental data on TRENTA facility are presented. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Fusion Power measurement at ITER

Nuclear fusion research aims to provide energy for the future in a sustainable way and the ITER project scope is to demonstrate the feasibility of nuclear fusion energy. ITER is a nuclear experimental reactor based on a large scale fusion plasma (tokamak type) device generating Deuterium - Tritium (DT) fusion reactions with emission of 14 MeV neutrons producing up to 700 MW fusion power. The measurement of fusion power, i.e. total neutron emissivity, will play an important role for achieving ITER goals, in particular the fusion gain factor Q related to the reactor performance. Particular attention is given also to the development of the neutron calibration strategy whose main scope is to achieve the required accuracy of 10% for the measurement of fusion power. Neutron Flux Monitors located in diagnostic ports and inside the vacuum vessel will measure ITER total neutron emissivity, expected to range from 1014 n/s in Deuterium - Deuterium (DD) plasmas up to almost 10{sup 21} n/s in DT plasmas. The neutron detection systems as well all other ITER diagnostics have to withstand high nuclear radiation and electromagnetic fields as well ultrahigh vacuum and thermal loads. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration of the ITER Tokamak C-model with the Building Model

The pellet injector system is designed to accommodate the requirement of continuous plasma refueling during ITER Tokamak operations. Through pellet flight tubes/injection lines, the pellets can directly reach the interior of the tokamak vacuum vessel. The pellet injector system is located at a port cell outside of the Tokamak bio-shield. The plasma radiation source in the tokamak vacuum vessel, together with the highly activated surrounding water in port cells, present major radiation challenges for the pellet injector system during ITER operation and after shutdown. These sources produce a radiation field encompassing the entire Tokamak complex. The ITER neutronics reference model C-model is an ITER radiation transport model. It represents a 40 deg. regular torus sector out to the bio-shield, which consists of 38 individual systems. The Monte Carlo N-Particle (MCNP) input of the C-model consists of more than a hundred thousand cell definitions and surface definitions, and over three hundred material compositions. The latest tokamak complex MCNP model is significantly more detailed than any previous releases. It consists of 36,863 cell definitions, 57,105 surface definitions, and a total of 21 different types of materials. The C-model and tokamak building model share the bio-shield as the boundary between them. In general, the radiation fields in the building due to the plasma source during tokamak operation are determined by generating the radiation source in the inner faces of the bio-shield. An inherent limitation of this approach is that it can only approximate the directions in which streaming paths are produced through the bio-shield plugs. To better estimate the shutdown dose rate for the pellet injector system due to the plasma source, we have decided to integrate the tokamak model (C-model) with the complex building model. Both MCNP models are provided by the ITER International Organization (IO) to the Oak Ridge National Laboratory (ORNL) Radiation Transport (RT) group.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced Simulation of ITER Core X-ray Crystal Spectroscopy

X-Ray Simulation Analysis (XRSA) is an analytical ray-tracing mixed code developed specifically for the ITER Core X-Ray Crystal Spectroscopy (XRCS-Core) diagnostic, which employs a dual-reflection configuration incorporating multiple pre-reflectors made of Highly Oriented Pyrolytic Graphite (HOPG) and spherically curved analyzing crystals. The ITER XRCS-Core is designed for high spectral resolution measurement in specific wavelength ranges, including narrow bands around 1.354 Å for W 64+ , 2.19 Å for Xe 51+ , and 2.555 Å for Xe 44+ and Xe 47+ , enabling diagnostic capability across a broad electron temperature range in the ITER plasma. XRSA facilitates efficient simulation of the spectral performance of this complex X-ray spectroscopic system. Recent updates to the XRSA code have incorporated two critical effects: auto-focusing, which specifically applies to HOPG, and polarization. These two effects are particularly important in the dual-reflection configuration used in the ITER XRCS-Core system to provide more accurate modeling results. Here, simulations conducted with the updated code demonstrate that polarization has a substantial impact on the performance of the dual-reflection system. Additionally, the combined influence of polarization and system layout introduces performance variations across channels through the same crystal.

Computer graphics↗