Ultrafast Photofragmentation of Ln(hfac)3 with a Proposed Mechanism for forming High Mass Fluorinated Products

Abstract The photo-induced dissociative-ionization of lanthanide complexes Ln(hfac) 3 (Ln = Pr, Er, Yb) is studied using intense ultrafast transform limited (TL) and linearly chirped laser pulses in a time-of-flight (TOF) mass spectrometry setup. Various fluorine and Ln-containing high-mass fragments were observed in this experiment, including the molecular parent ion, which have not been seen with previous studies relying on relatively long-duration laser pulses (i.e., ns or longer). These new high-mass observations provide important formerly missing information for deducing a set of photo-fragmentation mechanistic pathways for Ln(hfac) 3 . An overall ultrafast control mechanism is proposed by combining insights from earlier studies and the fragments observed in this research to result in three main distinct photo-fragmentation processes: (a) ligand-metal charge transfer, (b) CF 3 elimination, and (c) C-C bond rotation processes. We conclude that ultrafast dissociative-ionization could be a promising technique for generating high-mass fragments for potential use in material science applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast rise breakdown in dielectric filled air gap for surge protection

Electric discharge across an air gap can be self-healing, providing a unique capability for repetitive, fast, high-voltage/current switching applications through arc conduction. Furthermore, incorporating dielectric granules in the air gap stimulates gas ionization, which lowers the breakdown voltage and narrows breakdown voltage distribution, thereby enabling engineered surge protection from multiple lightning strikes on aerospace vehicles and sensitive solid-state electronics in critical systems. This study investigates the effect of the permittivity of dielectric granules, gap filling, surface roughness, and metal work function on fast-rising, high-voltage breakdowns. In addition to the air gap width, these factors play important roles in gas ionization, field concentration, and initiation of electrical discharge and arcing. Therefore, they could potentially be used to control and narrow operational breakdown voltages for practical applications. Additionally, a modified Langevin–Debye model is developed to correlate the breakdown voltage and the permittivity of the dielectric filler. These investigations identify and highlight key underpinning mechanisms governing the gas discharge behavior across a dielectric filled air gap during voltage surge events.

42 ENGINEERING↗

Experiments with a prototype titanium hot cavity surface ionization source intended for electromagnetic separation of radioactive samarium and other lanthanide elements

This paper reports experimental results of a prototype titanium surface ionization source. For the first time, a lanthanide ion beam has been produced with a surface ionizer composed completely of titanium metal. Titanium does not readily activate with neutron irradiation. This offers the potential for inserting an ion source made of titanium directly into a reactor with a pre-loaded non-radioactive lanthanide target. This seamlessly integrates target irradiation with isotope separation, eliminating post irradiation sample manipulation. Samarium ion beam currents up to 960 nA have been produced in an off-line test bench equipped with rudimentary beam optics. This is a crucial step toward the development of an ionization source adopted for the electromagnetic isotope separator (EMIS) facility, which has been designed for high throughput separations of radioactive 153 Sm and other lanthanides of interest in the field of nuclear medicine. The ion current and important factors affecting the performance of the ion source, such as the ionizer temperature and thermal gradient, are discussed. Lastly, the experimental results are presented together with a discussion of future modifications to optimize the overall surface ionization source performance.

07 ISOTOPE AND RADIATION SOURCES↗

Advanced Thermoluminescence Spectroscopy as a Research Tool for Semiconductor and Photonic Materials: A Review and Perspective

Thermoluminescence (TL) or thermally stimulated luminescence (TSL) spectroscopy is based on liberating charge carriers from traps in the bandgap by providing enough thermal energy to overcome the potential barrier of the traps. It provides a powerful tool to measure the positions of the localized states/traps in the bandgap. Despite that, its applications in semiconductors are very limited. Herein, the basics of TL spectroscopy and the recent advances in the technique with focus on cryogenic thermally stimulated photoemission spectroscopy (C‐TSPS) which extends TL measurements to cryogenic regime and allows the detection of very low concentrations of shallow and deep localized states is discussed. One goal herein is to introduce the reader to the use of TL and C‐TSPS in the characterization of semiconductors, explaining how it can be applied and demonstrating its advantages as a powerful tool for measuring shallow donor/acceptor ionization energies in semiconductors and as a method for characterizing compensating defects. The article also discusses interesting potential applications of C‐TSPS in new research areas such as corrosion and formation of oxide layers on metal surfaces.

36 MATERIALS SCIENCE↗

Raman spectroscopy coupled with ambient ionization mass spectrometry: A forensic laboratory investigation into rapid and simple dual instrumental analysis techniques

We present a laboratory experiment, developed around a pair of instrumental analysis techniques, Raman spectroscopy and ambient ionization mass spectrometry (MS), conducted by senior chemistry undergraduate students for bulk analysis of over-the-counter drugs using benchtop versions of the two instruments, as well as trace analysis of illicit drugs utilizing the corresponding portable instruments. The identification and confirmation of seized drugs is a routine operation in forensic laboratories that can be simplified using these two instrumental techniques in tandem. Bulk samples are readily analyzed using conventional Raman spectroscopy followed by paper cone spray ionization (PCSI) MS, while trace analysis is allowed by a simple single-substrate dual-analyzer method using surface enhanced Raman spectroscopy (SERS) from paper followed by paper spray ionization (PSI) MS. The introduction of these novel strategies to the students exposed them to potential career paths in forensic science by means of a hands-on experience that provided fundamental knowledge about this set of analytical methods, including intercomparisons of their performance, as well as practical issues like costs, regulations and databases. The use of portable instrumentation represents an additional learning experience for the students, considering that it is cutting-edge technology that is just now being transferred from academic to industrial labs and that it allows a valuable discussion of the advantages and disadvantages of bringing the laboratory to the field.

47 OTHER INSTRUMENTATION↗

Mapping and imaging ionizing radiation in two and three dimensions

A two-dimensional imaging system and a two-dimensional or three-dimensional optical tomographic mapping system, each employing gas scintillation induced by ionizing radiation, i.e., radioluminescence, and corresponding methods, are disclosed. The systems may employ one or more cameras and corresponding UV filters (potentially solar blind filters) for imaging a radioluminescent scene. For two-dimensional or three-dimensional mapping, the resultant UV images are spatially registered with one another and then reconstructed to form a three-dimensional tomographic map of the ionizing radiation. The two-dimensional map is a plane of the three-dimensional map. The UV images may be spatially registered by using a reference source, optionally, a calibrated reference source allowing dosimetry calculations for the ionizing radiation. Molecular nitrogen is the primary candidate for the radioluminescent gas, though a controlled ambient in a chamber of nitric oxide, argon, krypton, or xenon may be employed. The reconstruction process employs an algebraic reconstruction technique or an Abel inversion.

Bentz, Brian Z.↗

The impact of halo concentration on the Sunyaev Zel’dovich effect signal from massive galaxy clusters

ABSTRACT The Sunyaev Zel’dovich (SZ) effect is sensitive to the pressure of ionized gas inside galaxy clusters, which is in turn controlled largely by the gravitational potential of the cluster. Changing the concentration parameter describing the cluster mass distribution impacts the gravitational potential and thus the cluster SZ signal, with implications for cosmological and other analyses of SZ-selected clusters. We investigate the concentration–SZ relation in theory and simulations. We find that the impact of concentration on the inner SZ profile (R ≲ 0.75R200c) can be captured with standard polytropic gas models. However, we find that such models do a poor job of reproducing the outer SZ profiles (R ≳ 0.75R200c) and the relation between the integrated SZ signal, Y, and concentration. This disagreement results from a sharp truncation of the gas pressure profile near the splashback radius, likely caused by virial shocks. We develop a simple description of the truncation that leads to a good match with the simulated SZ profiles out to several R200c for clusters of varying mass and concentration, and that also accurately predicts the concentration–Y relationship. Finally, we determine how inference of the linear bias parameter and splashback radius for SZ-selected clusters can be biased by ignoring the concentration dependence of the SZ signal, finding that bias to the former is essentially negligible, while bias to the latter can be as much as 2 per cent.

Astronomy & Astrophysics↗

High-resolution X-ray spectroscopy of the stellar wind in Vela X-1 during a flare

In this work, we present a ~130 ks observation of the prototypical wind-accreting, high-mass X-ray binary Vela X-1 collected with XMM-Newton at orbital phases between 0.12 and 0.28. A strong flare took place during the observation that allows us to investigate the reaction of the clumpy stellar wind to the increased X-ray irradiation. To examine the wind’s reaction to the flare, we performed both time-averaged and time-resolved analyses of the RGS spectrum and examined potential spectral changes. We focused on the high-resolution XMM-Newton RGS spectra and divided the observation into pre-flare, flare, and post-flare phases. We modeled the time-averaged and time-resolved spectra with phenomenological components and with the self-consistent photoionization models calculated via CLOUDY and XSTAR in the pre-flare phase, where strong emission lines due to resonant transitions of highly ionized ions are seen. In the spectra, we find emission lines corresponding to K-shell transitions in highly charged ions of oxygen, neon, magnesium, and silicon as well as radiative recombination continua (RRC) of oxygen. Additionally, we observe potential absorption lines of magnesium at a lower ionization stage and features identified as iron L lines. The, CLOUDY and XSTAR photoionization models provide contradictory results, either pointing towards uncertainties in theory or possibly a more complex multi-phase plasma, or both. We are able to demonstrate the existence of a plethora of variable narrow features, including the firm detection of oxygen lines and RRC that RGS enables to observe in this source for the first time. We show that Vela X-1 is an ideal source for future high-resolution missions, such as XRISM and Athena.

79 ASTRONOMY AND ASTROPHYSICS↗

Cooper minima of atoms in a plasma environment

Recent efforts have extended the calculations of photon ionization and associated Cooper minima to atoms in a plasma environment simulated by screening the atomic potential. Furthermore, in this paper previously unrecognized features of bound electron photon excitations in screened atomic potentials are examined. First, the Cooper minima location as a function of photon energy is shown to be weakly dependent on the screening, which is explained by stationary perturbation theory. Second, the screening transfers transition probability from high to low photon energies relative to the isolated atom result.

Cooper minima↗

Self-interaction-corrected Kohn–Sham effective potentials using the density-consistent effective potential method

Density functional theory (DFT) and beyond-DFT methods are often used in combination with photoelectron spectroscopy to obtain physical insights into the electronic structure of molecules and solids. The Kohn–Sham eigenvalues are not electron removal energies except for the highest occupied orbital. The eigenvalues of the highest occupied molecular orbitals often underestimate the electron removal or ionization energies due to the self-interaction (SI) errors in approximate density functionals. Here, we adapt and implement the density-consistent effective potential method of Kohut, Ryabinkin, and Staroverov (2014) to obtain SI-corrected local effective potentials from the SI-corrected Fermi–Löwdin orbitals and density in the Fermi–Löwdin orbital self-interaction correction scheme. The implementation is used to obtain the density of states (photoelectron spectra) and HOMO–LUMO gaps for a set of molecules and polyacenes. Good agreement with experimental values is obtained compared to a range of SI uncorrected density functional approximations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

U-Pb zircon age constraints on the earliest eruptions of the Deccan Large Igneous Province, Malwa Plateau, India

Climate instability driven by emission of volatiles during emplacement of large igneous provinces (LIPs) is frequently invoked as a potential cause of mass extinctions. However, documenting this process in the geologic record requires a holistic understanding of eruption rates, the location of eruptive centers, and potential sources of climate-changing volatiles. We present new chemical abrasion–isotope dilution–thermal ionization mass spectrometry (CA-ID-TIMS) U-Pb zircon geochronology from Malwa Plateau basalts on the northern margin of the Deccan LIP, India. These basalts have been previously interpreted as either an extension of the province's main volcanic stratigraphy or as an independent eruptive center active up to millions of years prior to the main eruptive phase. Our data instead demonstrate that the lower Malwa Plateau basalts are temporally correlative with the first pulse of Deccan volcanism and provide new constraints on its initiation and duration. Paleomagnetic data further indicate that upper Malwa Plateau basalts may be age-equivalent to the second, third, and fourth pulses of Deccan volcanism. The relative thicknesses of age-equivalent packages of basalt are consistent with eruption of the Deccan LIP from a southward-migrating eruptive center. The first eruptive pulse is coeval with a ~200 kyr Late Maastrichtian warming event preserved globally in contemporaneous stratigraphic sections. We propose that the first pulse of Deccan magmatism was more voluminous in the north, where it erupted through organic-rich sedimentary rocks of the Narmada-Tapti rift basin. Thermal metamorphism of these sediments could have been a source of sufficient CO 2 to drive the Late Maastrichtian warming event, which if true would reconcile the apparent dampened warming signals associated with later Deccan eruptive pulses.

58 GEOSCIENCES↗

Colloidal Stability of PFSA-Ionomer Dispersions. Part I. Single-Ion Electrostatic Interaction Potential Energies

Charged colloidal particles neutralized by a single counterion are increasingly important for many emerging technologies. Attention here is paid specifically to hydrogen fuel cells and water electrolyzers whose catalyst layers are manufactured from a perfluorinated sulfonic acid polymer (PFSA) suspended in aqueous/alcohol solutions. Partially dissolved PFSA aggregates, known collectively as ionomers, are stabilized by the electrostatic repulsion of overlapping diffuse double layers consisting of only protons dissociated from the suspended polymer. We denote such double layers containing no added electrolyte as "single ion". Size-distribution predictions build upon interparticle interaction potential energies from the Derjaguin-Landau-Verwey-Overbeek (DLVO) formalism. However, when only a single counterion is present in solution, classical DLVO electrostatic potential energies no longer apply. Accordingly, here a new formulation is proposed to describe how single-counterion diffuse double layers interact in colloidal suspensions. Part II (Srivastav, H.; Weber, A. Z.; Radke, C. J. Langmuir 2024 DOI: 10.1021/acs.langmuir.3c03904) of this contribution uses the new single-ion interaction energies to predict aggregated size distributions and the resulting solution pH of PFSA in mixtures of n-propanol and water. A single-counterion diffuse layer cannot reach an electrically neutral concentration far from a charged particle. Consequently, nowhere in the dispersion is the solvent neutral, and the diffuse layer emanating from one particle always experiences the presence of other particles (or walls). Thus, in addition to an intervening interparticle repulsive force, a backside osmotic force is always present. With this new construction, we establish that single-ion repulsive pair interaction energies are much larger than those of classical DLVO electrostatic potentials. The proposed single-ion electrostatic pair potential governs dramatic new dispersion behavior, including dispersions that are stable at a low volume fraction but unstable at a high volume fraction and finite volume-fraction dispersions that are unstable with fine particles but stable with coarse particles. Finally, the proposed single-counterion electrostatic pair potential provides a general expression for predicting colloidal behavior for any charged particle dispersion in ionizing solvents with no added electrolyte.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward the Development of Molten Salt Reactor Diagnostics based on Resonantly Enhanced Laser Spectroscopy

One emerging concern within the safeguards community is how to best ensure compliance with nuclear security regulations within molten salt reactor (MSR) facilities. This problem is nontrivial as molten salts used for fuel or coolant are highly corrosive, chemically complex, and inherently require high operational temperatures. Laser spectroscopy methods such as laser-induced breakdown spectroscopy (LIBS) and laser-induced fluorescence (LIF) have previously been suggested for molten salt diagnostics due to their compatibility with liquid phase samples and potential for in-situ measurements [1]. In the former, the laser is used to ionize the sample, allowing for the characteristic light from electronic de-excitation as the resultant plasma cools to be used for material characterization. In the latter, a tunable light source is set be resonant with a specific transition, resulting in element specific excitation and the emission of fluorescence light. In our previous work [2], we demonstrated that LIF could be used for the detection of fission fragments such as Nd in solution through the separation of laser scatter and fluorescence within the time domain. Here, we present progress towards two alternate measurement schemes: LIF measurements based on spectroscopic discrimination of fluorescence emissions and resonant LIBS measurements that induce plasma using a light source set to the resonant frequency of a specific electronic transition. Both methods aim to exploit resonant excitation methods to enhance the emitted signal. The studies may provide routes for element-specific detection of constituents within complicated matrices and a means to better understand the chemical behavior of lanthanides and actinides relevant to MSRs.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Pulse Detonation Engine for Advanced Oxy-Combustion of Coal-Based Fuel for Direct Power Extraction Applications

Pressure gain combustion and magnetohydrodynamic (MHD) systems have the potential to provide a step increase in the efficiency of combined-cycle power plants. Specific advantages include a net pressure increase to the system instead of a pressure drop, the high temperature of the detonation waves can increase the efficiency of power extraction compared to other processes, significant thermal energy can be released in a compact region, and the high velocities of the flow increase extraction of electrical power. In summary, a pressure gain combustor coupled with a MHD has the potential to be transformative. Despite the potential advantages, relatively little research has been conducted considering coupled pressure gain combustion systems with MHD systems. With this background and motivation, the overall goal of this effort was to advance the knowledge, technology, and computational tools associated with coupled detonation and MHD systems. A joint experimental and computational approach was used while seeking to accomplish the goals of this work. Specifically, two pulse detonation engines were developed and used for the experiments to produce detonations. Detonation speeds were measured for a variety of flow and fuel conditions (e.g., methane, propane, with coal particles). Preliminary electrical conductivity measurements were collected. An extensive amount of research was performed to identify sensitivities of detonation behaviors to the presence of combustion products. Computationally, a twofold approach was used in this work. First, a solver was developed for solving the governing equations for a reactive flow with coupled detonation and ionization chemistry. The solver was applied to study the impacts of seed material ionization on detonation. Second, a conservation element-solution element (CE-SE) based numerical solver for detonation studies with a reduced reaction mechanism for oxy-methane combustion was developed and verified on standard test cases. Key findings and contributions from this work are as follows. A system was developed for injecting powderized coal, or other seeding material, into a pulse-detonation system. The influence of a combustion product (i.e., CO 2 ) on detonation behavior was identified. Knowledge gained from this work is applicable to devices such as rotating detonation engines, where combustion products mix with fresh reactants. A system for measuring the electrical conductivity of the exhaust from a pulse-detonation engine was developed. The open-source solver, Clawpack, was extended to solve the reactive Euler equations for simulating detonations. A coupled combustion and ionization chemistry was developed in a single chemical kinetic model for methane oxidation. This model can be used to solve coupled MHD and detonation simulations. It was found that parasitic interactions from ionization chemistry with the magnetic field can reduce the detonation velocity by up to 8%, with a potential impact on power extraction of 15%. It is recommended that interactions between the detonation front and MHD field be considered. Higher gas temperatures and velocities were achieved owing to oxy-fuel detonations. Use of radical dissociation reactions in the reduced reaction mechanism, was found to be critical in predicting detonation temperature and velocity accurately.

01 COAL, LIGNITE, AND PEAT↗

Ambient Ion Trapping and Separations for High Throughput Structurally Selective Material Deposition

While ion mobility coupled to mass spectrometry (IMS/MS) has been increasingly adapted to biological analysis, the structural and molecular specificity offered by IMS/MS has untapped potential for creating novel materials (for energy, catalysis, biomolecular switches etc.) with rationally tailored properties by precisely controlling the chemical structure and composition of these materials. While electrochemical and catalytic properties of the bulk material are understood by mass-selective ion-soft-landing, different structures of one molecule can exhibit distinct properties from the bulk. Many biological phenomenon occur at interfaces and are highly structurally specific. IMS/MS offers means to separate molecules in a sample (which is first ionized and released to gas phase from the condensed phase) based on mass and structure. Species thus separated can potentially be deposited onto surfaces with molecular and structural specificity, to perform fundamental investigations for understanding critical interfacial phenomenon. Key performance metrics for IMS/MS analysis are resolution of separations and sensitivity. Recently developed Structures for Lossless Ion Manipulations (SLIM)4 enabled unprecedented resolution in IMS separations. In addition, high sensitivity was enabled in SLIM due to lossless confinement of ions using radio frequency fields. Thus, SLIM enabled extremely long path length separations (up to 0.1 km thus far) providing efficient separation of molecular ions never before achieved (e.g. isotopologues, D&L amino acids). While SLIM has unprecedented analytical separations power/utility, the use of SLIM platform for depositing mobility and mass selected molecular ions has two specific technological challenges: (a) Pulsed nature of IMS separations and their low duty cycle and (b) the need for a low vacuum of ~4 torr for lossless ion confinement. These limitations lead to long deposition times due to loss of ions generated from the sample. Enabling ion confinement at atmospheric pressure will be path-breaking contribution to the fundamental understanding of ion manipulations and separations and will also enable novel science currently precluded due to the inability of the present technologies to confine ions under ambient conditions. Traditionally used radio frequency fields are ineffective in confining ions at high pressures due to ion/neutral collisions. To address these, we propose to (a) develop methods for confining and manipulating ions for lossless IMS separations at atmospheric pressure enabling high sensitivity and throughput and (b) use the high specificity of IMS/MS and high throughput from ambient ion confinement to perform mobility and mass selective ion deposition at atmospheric pressure. Our goal is to enable the study of the fundamental properties of energy/catalysis materials and biomolecules. This project paves the way for high-throughput, mass and structure selective material deposition for highly specific surface creation/functionalization (discussed in Section 2 of the report). Further, the developments reported continue to push the boundaries of this process to ambient conditions (discussed in Section 3 of the report). We conclude with a list of specific intellectual property and publications which have been the outcome of this funded project.

36 MATERIALS SCIENCE↗

Effects of screening and pressure ionization on the electron broadening of spectral lines in dense plasmas

Collisions between electrons and radiating atoms broaden spectral absorption and emission lines in dense plasmas. High densities also introduce screening and pressure ionization effects that distort the wave functions of both bound and free electrons. In order to study how dense plasma effects influence the electron broadening of spectral lines, this paper incorporates electron wave functions from an average-atom (AA) model to calculate the linewidth of the B III 2⁢𝑝−2⁢𝑠 transition at 𝑇 = 10 eV for mass densities ranging from 𝜌 = 10 −4 to 0.4⁢ g⁡/cc. The calculation method uses the impact approximation, allowing the linewidth to be written in terms of electron-collision cross sections and an interference term. Compared to an otherwise identical calculation that uses Coulomb free wave functions, the AA method is found to modify both the cross sections and the resulting linewidth at sufficiently high density by introducing screening and pressure-ionized bound states. Screening lowers the cross sections at low energies and near electron excitation thresholds, while pressure-ionized bound states introduce resonances into the continuum. Thus, as the density increases, the relative linewidth between the AA and Coulomb calculations follows a general decrease because of screening, with sharp increases at various intervals due to pressure ionization. Finally, the AA results are also compared with a common approach to introduce screening through the interaction potential and reduced models that use the Bethe formula for the inelastic electron-collision cross sections.

electronic excitation & ionization↗

Partial-wave decomposition of the Keldysh ionization amplitude

We present an alternative way of calculating the Keldysh amplitude, i.e., the length-gauge form of the ionization amplitude in the strong-field approximation. The amplitude is evaluated exactly by expanding it in Fourier components and partial waves. Comparisons of the semianalytic model predictions with results of ab initio numerical simulations of the time-dependent Schrödinger equation for the interaction of electrons in short-range potentials with intense laser light yield excellent agreement, for wavelengths from the single photon to the multiphoton to the tunneling regime. Specifically, for ionization from initial states with higher angular momentum quantum number, e.g., p states, a significant improvement over predictions based on the popular saddle-point approximation is found. Furthermore, the current model rate allows for interpretation of the strong-field ionization process in terms of multiphoton absorption pathways and angular momentum selection rules.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-resolution modeling of indoor radon exposure with uncertainty quantification in Utah

Indoor radon accounts for 37% of population-level exposure to ionizing radiation in the United States. However, radon metrics are typically reported at coarse spatial scales, potentially obscuring meaningful local variation. We developed a high-resolution modeling framework to estimate indoor radon concentrations across Utah while explicitly quantifying predictive uncertainty. A total of 19,497 residential radon measurements collected between 2006 and 2017 were combined with environmental and housing characteristics and analyzed using a geospatial neural network that accommodates spatial dependence and nonlinear associations. Predictions were generated on a uniform hexagonal grid at 0.73 km2 resolution (H3 level 8). Out-of-sample predictions aggregated to the H3 level 8 grid showed good agreement with observed concentrations (Pearson r=0.64), while household-level predictions exhibited more moderate agreement (r=0.45). The model produced well-calibrated uncertainty estimates, with 24.1% of held-out observations exceeding the predicted 75th-percentile threshold. Maps of predicted radon concentrations and the probability of exceeding the U.S. EPA action level of 148 Bq/m3 (4 pCi/L) revealed substantial fine-scale spatial heterogeneity that was not apparent in conventional coarse-resolution summaries, with greater local variability observed in densely monitored urban counties than in sparsely sampled regions. High-resolution radon models that explicitly quantify uncertainty provide a useful framework for characterizing the spatial distribution of indoor radon and identifying areas of elevated exceedance risk. These findings highlight the value of fine-scale monitoring data and uncertainty-aware modeling approaches for radon exposure assessment, environmental risk characterization, and radon-related health research.

Wu, Yunhan [ORNL] (ORCID:0000000178842994)↗