Activation of Thermal Insulation and Contamination Prevention
The goals of this paper are to enhance the understanding of the potential activation and contamination hazards from the use of insulating materials in the Molten Chloride Reactor Experiment and to foster safer work environments through informed decision-making and strategic planning. It was written to resolve a gating comment from the core heating system preliminary design review. The largest dose expected from the considered insulation materials is about 0.1 mrem per year from Pyrogel. Although Cerablanket stood out among the insulation materials for encouraging ALARA practices, it has a higher thermal conductivity. At low power levels, focusing on reducing the generation of dust from ERD activities may be more effective for reducing the potential spread of contamination than changing the insulating material type. However, regardless of the material chosen, PPE and safety conscious procedural practices can help reduce the production and spread of activated dust––thus minimizing the radiological hazard to workers.