Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPACT LOAD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

High-Efficiency Conversion of Ionic Liquid-Pretreated Woody Biomass to Ethanol at the Pilot Scale

We report that with a diverse and widely distributed global resource base, woody biomass is a compelling organic feedstock for conversion to renewable liquid fuels. In California, woody biomass comprises the largest fraction of underutilized biomass available for biofuel production, but conversion to fuels is challenged both by recalcitrance to deconstruction and by toxicity toward downstream saccharification and fermentation due to organic acids and phenolic compounds generated during pretreatment. In this study, we optimize pretreatment and scale-up of an integrated one-pot process for deconstruction of California woody biomass using the ionic liquid (IL) cholinium lysinate [Ch][Lys] as a pretreatment solvent. By evaluating the impact of solid loading, solid removal, yeast acclimatization, fermentation temperature, fermentation pH, and nutrient supplementation on final ethanol yields and titers, we achieve nearly full conversion of both glucose and xylose to ethanol with commercial C5-utilizing Saccharomyces cerevisiae. We then demonstrate process scalability in 680 L pilot-scale fermentation, achieving >80% deconstruction efficiency, >90% fermentation efficiency, 27.7 g/L ethanol titer, and >80% ethanol distillation efficiency from the IL-containing hydrolysate post fermentation. This fully integrated process requires no intermediate separations and no intermediate detoxification of the hydrolysate. Using an integrated biorefinery model, current performance results in a minimum ethanol selling price of $\$$8.8/gge. Reducing enzyme loading along with other minor process improvements can reduce the ethanol selling price to $\$$3/gge. This study is the largest scale demonstration of IL pretreatment and biofuel conversion known to date, and the overall biomass-to-ethanol efficiencies are the highest reported to date for any IL-based biomass-to-biofuel conversion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthetic residential load models for smart city energy management simulations

The ability to control tens of thousands of residential electricity customers in a coordinated manner has the potential to enact system-wide electric load changes, such as reduce congestion and peak demand, among other benefits. To quantify the potential benefits of demand-side management and other power system simulation studies (e.g. home energy management, large-scale residential demand response), synthetic load datasets that accurately characterize the system load are required. This study designs a combined top-down and bottom-up approach for modelling individual residential customers and their individual electric assets, each possessing their own characteristics, using time-varying queueing models. The aggregation of all customer loads created by the queueing models represents a known city-sized load curve to be used in simulation studies. The three presented residential queueing load models use only publicly available data. An open-source Python tool to allow researchers to generate residential load data for their studies is also provided. The simulation results presented consider the ComEd region (utility company from Chicago, IL) and demonstrate the characteristics of the three proposed residential queueing load models, the impact of the choice of model parameters, and scalability performance of the Python tool.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation of the nacelle blockage effect for a downwind turbine

As downwind turbines garner increasing research interest, nacelle blockage becomes an important consideration. This paper examines nacelle blockage effects under a variety of Reynolds numbers, turbulence intensities, and nacelle geometries and proposes a computationally inexpensive nacelle blockage engineering model. Results show minimal nacelle blockage impacts on rotor loading and performance, except for tall (low-aspect-ratio) nacelles, which can cause an increase in rotor C p of up to 0.6%. In all cases, nacelle blockage increases rotor loading and performance metrics, however little. Finally, (more expensive) geometry-resolved and (less expensive) body-force computational fluid dynamics modeling techniques are compared, and body-force models are found to need improvement to adequately model nacelle blockage.

17 WIND ENERGY↗

Lifetime fatigue response due to wake steering on a pair of utility-scale wind turbines

Quantifying the impacts on turbine loads during wind farm control is an important consideration in assessing power production benefits. Wake steering controls aim to improve total wind farm performance by coordinating the control actions of individual turbines, wherein an upstream turbine is intentionally yawed at an offset angle from the measured wind direction. Consequently, this redirects its wake for improved power production and potentially reduces fatigue loads of the downstream turbines. This paper studies the lifetime fatigue loads associated with wake steering by using utility-scale wind turbine experimental data to conduct an analysis on a pair of wind turbines. This study was part of a large field experiment in which a group of five GE 1.5-MW SLE CWE turbines were selected as targets for conducting wake steering research. A standard loads instrumentation package and data acquisition system were installed on two turbines within the cluster to measure turbine fundamental loads. The time-series databases were used to calculate loads statistics as well as short-term and lifetime damage equivalent loads. Fatigue calculations followed the guidance in Annex H of the International Electrotechnical Commission standard 61400-1, Edition 4. Lifetime fatigue calculation results are presented in this analysis; three methods of assessing lifetime fatigue were used to determine percent difference for blade root moments, main shaft moments, main shaft torque, and tower top torque. For all three fatigue treatments, some components’ lifetime fatigue increases for the controlled turbine; however, the downwind turbine experienced a reduction in lifetime fatigue and combined effect for the turbine pair results in a reduction of fatigue when wake steering controls are applied.

17 WIND ENERGY↗

Temperature and nutrients drive eco-phenotypic dynamics in a microbial food web

Anthropogenic increases in temperature and nutrient loads will likely impact food web structure and stability. Although their independent effects have been reasonably well studied, their joint effects—particularly on coupled ecological and phenotypic dynamics—remain poorly understood. Here we experimentally manipulated temperature and nutrient levels in microbial food webs and used time-series analysis to quantify the strength of reciprocal effects between ecological and phenotypic dynamics across trophic levels. We found that (1) joint—often interactive—effects of temperature and nutrients on ecological dynamics are more common at higher trophic levels, (2) temperature and nutrients interact to shift the relative strength of top-down versus bottom-up control, and (3) rapid phenotypic change mediates observed ecological responses to changes in temperature and nutrients. Our results uncover how feedback between ecological and phenotypic dynamics mediate food web responses to environmental change. As a result, this suggests important but previously unknown ways that temperature and nutrients might jointly control the rapid eco-phenotypic feedback that determine food web dynamics in a changing world.

59 BASIC BIOLOGICAL SCIENCES↗

Bilevel Nodal Behind-the-meter Solar Disaggregation Under Unexpected Extreme Weather Conditions

As the power grid undergoes significant paradigm shift due to the increasing penetration of renewable generation, the ever-growing installation of behind-the-meter (BTM) solar generation in the power grid also has a significant impact on nodal loads, posing challenges on transmission operators. Furthermore, increasing frequent and severe extreme weather events intertwine with ubiquitous BTM solar generations and have amplified the challenges of accurately model nodal load profiles, especially under the lack of ground-truth information for verification. To tackle these challenges, this paper introduces a bilevel model that utilizes year-long data (e.g., proxy solar, zonal load, and individual node load profiles) to disaggregate metered profiles into actual demand and BTM solar generation at each transmission node. The proxy solar not only scales the BTM solar generation of individual nodes but also create a compensation term for enhancing performance on days with unexpected extreme weather events. The proposed algorithm is validated with real-world PJM Interconnection data during unexpected events like the recent Winter Storm Elliott. For quantitative evaluations, a novel Score error is introduced, which is based on mean percentages and load scales and offers a universal assessment method suitable for all nodes and different data formats (e.g., normalized or raw values).

behind-the-meter solar, load disaggregations, load↗

TPCPF: Three-Phase Continuation Power Flow Tool for Voltage Stability Assessment of Distribution Networks With Distributed Energy Resources

This article presents a three-phase unbalanced continuation power flow algorithm for voltage stability assessment of distribution systems with high penetration of distributed energy resources (DERs). Analyzing distribution system voltage stability with DER will allow high penetration of renewable energy necessary for the sustainability goals. The developed algorithm can analyze voltage stability for both the meshed and radial systems and the balanced and unbalanced three-phase distribution systems. The developed tool allows the voltage stability analysis to facilitate the planning, operation, control, and distribution system management. The impact of DER on the voltage stability of several test cases has been analyzed considering constant power (P Q) and regulated-voltage (P V ) modes of operation for DER units. Moreover, different voltage stability case studies are presented to demonstrate the impact of unbalance, load increment, and network topology on the maximum loading capacity. Finally, results using the IEEE 13-node feeder, the 18-bus balanced shipboard system, the 13-node CIGRE benchmark system, and the 136-bus redial distribution feeder demonstrate that the developed continuation power flow tool can efficiently perform voltage stability analysis for active distribution systems.

42 ENGINEERING↗

tell: a Python package to model future total electricity loads in the United States

The purpose of the Total ELectricity Load (tell) model is to generate 21st century profiles of hourly electricity load (demand) across the Conterminous United States (CONUS). tell loads reflect the impact of climate and socioeconomic change at a spatial and temporal resolution adequate for input to an electricity grid operations model. tell uses machine learning to develop profiles that are driven by projections of climate/meteorology and population. tell also harmonizes its results with United States (U.S.) state-level, annual projections from a national- to global-scale energy-economy model. This model accounts for a wide range of other factors affecting electricity demand, including technology change in the building sector, energy prices, and demand elasticities, which stems from model coupling with the U.S. version of the Global Change Analysis Model (GCAM-USA). tell was developed as part of the Integrated Multisector Multiscale Modeling (IM3) project. IM3 explores the vulnerability and resilience of interacting energy, water, land, and urban systems in response to compound stressors, such as climate trends, extreme events, population, urbanization, energy system transitions, and technology change

24 POWER TRANSMISSION AND DISTRIBUTION↗

Empirical Validation of Multi-Zone HVAC System Model: Evaluation of Existing Infiltration Models used in Building Energy Simulation

Infiltration can have a significant impact on building loads. Studies have shown that infiltration can account for 15-40% of annual space conditioning needs in commercial buildings (Emmerich et al. 2019; Younes et al. 2012). The driving force of infiltration is the pressure difference across the building envelope caused by wind, the stack effect (known as buoyancy effect), and the operation of ventilation equipment. Wind pressure is governed by wind direction, speed, building shape, and other structures around the building. The stack effect is a function of the building height and air density differences of ambient air (Han, 2015). The effect of wind is dominant in low-rise residential buildings, and the stack effect is dominant in highrise buildings (ASHRAE 2017). In building energy simulation programs (e.g., EnergyPlus), various empirical infiltration models (e.g., the effective leakage area model, the flow coefficient model) are available to simulate infiltration rates. To help users in selecting a proper infiltration model for modeling of the two-story Flexible Research Platform (FRP), the team evaluates the existing infiltration models in EnergyPlus based on field measurements from the FRP. The blower door and tracer gas decay tests were performed in the FRP. The blower door test result was used to estimate input parameters required in the infiltration models. The actual infiltration rates were estimated with the tracer gas decay test results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aeroacoustic Assessment of Wind Plant Controls

The Aeroacoustic Assessment project aims to quantify changes in aeroacoustic noise generation by a utility scale wind turbine operating under imposed yaw offsets common for wake steering and wind plant control strategies. Active plant control utilizing wake deflection control strategies have been shown experimentally and computationally to reliably produce 1-2% of additional annual energy production (AEP) without significant changes in turbine structural loads, the potential impact on aeroacoustic emissions has yet to be quantified or completely understood. Yawed operation of a wind turbine changes the three-dimensional aerodynamic interaction between the rotor blades and the incoming atmospheric flow, leading to changes in noise generation. This work quantifies the extent to which active control induces additional aeroacoustic emissions from additional separation and other flow interaction dynamic effects. Given public concerns about wind turbine noise and the need for observational data required for regulators to establish noise restrictions, we must understand potential acoustic emissions resulting from active control prior to commercial deployment and the development of practical noise reduction methods and technologies. The work outlined in this report details the new aeroacoustic measurement capability developed at NREL and its application to making full-field observations of noise from a utility-scale wind turbine. Preliminary noise modeling with the aeroacoustics module in OpenFAST helped to establish the design of the experiment, specifically targeting the noise observed at observers distributed around the DOE-owned GE 1.5 MW wind turbine. Low-frequency and infrasound measurement capability implemented in this project establish an operational baseline for the wind turbine, setting the stage for future control, rotor blade, and turbine design research.

17 WIND ENERGY↗

Datasets for Widespread Residential Space Heating Electrification in Texas

In this experiment, we explore long term patterns in electricity demand driven by the dual effects of full electrification of space heating in Texas (by adoption of electric heat pumps), and climate change. We use a predictive model of electricity demand, climate projections, and an open source nodal power system (DC Optimal Power Flow) model of the Electric Reliability Council of Texas (ERCOT) system. Heat pumps are a more energy efficient way of providing space heating and cooling in homes. We attempt to exhaustively investigate the impacts of full residential space heating electrification by adoption of heat pumps for the segment of Texas households that currently rely on fossil fuels (about 40%), while simultaneously incorporating climate change meteorological variables. We explore a range of scenarios of heat pump efficiency and climate uncertainty over a long period of future years (2020-2099). In total, the simulation experiment generates 1,280 simulation years of hourly data. We report and analyze results in form of impacts on residential load, total load, peak load, seasonality of peaking, and reliability measured by occurrence and frequency of loss of load events. While the experiment is for ERCOT, the insights and approach can be applied to other regions. The results from the analysis can inform system planners on a range of potential capacity requirements/ reliability implications and/or risks of full space heating electrification via the adoption of electric heat pumps, given the uncertainty in the scenarios/ climate futures. The dataset includes model output for residential, non residential and total load, and the results from the GO ERCOT model runs for 4 RCP Scenarios (RCP 4.5 Cooler, RCP 4.5 Hotter, RCP 8.5 Cooler, RCP 8.5 Hotter), 4 Heating electrification Scenarios (Base , Standard Efficiency HP, High Efficiency HP, Ultra-High Efficiency HP) over 80 years (2020-2099). The metrological variables at BA scale were weighted weighted using population projections consistent with the SSP3 scenario.

Climate Change↗

Charging Infrastructure Technologies: Development of a Multiport, >1 MW Charging System for Medium- and Heavy-Duty Electric Vehicles

Development of a Multiport, >1 MW Charging System for Medium- and Heavy-Duty Electric Vehicles project will develop research tools for a framework to design, optimize, and demonstrate key components of a multi-port 1+ MW medium-voltage connected charging system. The objectives of this effort are to develop strategies and technologies for multi-port 1+ MW grid-connected stations to recharge MD/HD electric vehicles at fast-charging travel plazas or at fleet depots; through industry engagement, charging station utilization and load analysis, grid impacts and interconnection analysis, detailed power electronics component design and controller demonstration, site and battery charge control design and controller demonstration; and charging connector design.

1+MW charging↗

Seismic isolation: A pathway to standardized advanced nuclear reactors

Standardizing advanced nuclear reactors is a pathway to substantially reducing their overnight capital cost and achieving parity with other power sources, including renewables and fossil fuels. The seismic load case has thwarted standardization of nuclear power plants because site-specific seismic hazard and local near-surface geology has triggered soil-structure-interaction analysis, design, equipment qualification, regulatory review, and licensing, ensuring that each build is different. To achieve standardized or site-independent certified advanced reactor designs, the impact of the seismic load case on the engineering and construction cost and time must be substantially mitigated. Seismic isolation is a mature technology that has been used for more than 30 years in non-nuclear sectors to substantially reduce earthquake demands in buildings and other infrastructure. In this paper, seismic isolation is used to enable standardization of advanced reactor designs, aimed at the complete re-use of a site-independent, certified design and repeated procurement of safety-class equipment. A pathway to standardized designs using seismic isolation is demonstrated for two fundamentally different advanced reactors: a molten salt reactor and a high temperature gas reactor. Each reactor building is equipped with three specialized pieces of safety-class equipment, namely, a reactor vessel, a steam generator, and a control rod drive mechanism housing that is attached to the reactor head. Analysis is performed per ASCE and ASME standards to design the buildings and the equipment for two base conditions: conventional (fixed base) and base isolated. The impact of the seismic load case is characterized for the reinforced concrete walls in the buildings and for the equipment, measured using vessel wall thickness and horizontal accelerations. Here the analysis results show that the fixed-base buildings, designed for a site of low seismic hazard (peak ground acceleration, PGA = 0.15 g) could be constructed at a site of much greater seismic hazard (PGA = 0.7 g) if seismic base isolation is employed. Importantly, the scope of the site-specific analysis, design, and qualification would be limited to the seismic isolators and the isolated substructure, drastically reducing plant-specific engineering, review, and licensing, and time to construction start. Regulatory challenges and opportunities with standardized reactor designs are identified.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of 304L stainless steel deformation and failure under cyclic loading

The motivation for this work came from the simulation of components subjected to impact. In these problems, repeated loading can be generated by vibrational motion between internal parts of the component or by the occurrence of multiple impacts. Graphs of tensile equivalent plastic strain $(\overline{\varepsilon}_T^\rho)$ versus time from such cases had the character shown in Fig. 1. The equivalent plastic strain grew by alternating periods of accumulation and hold. The periods of hold indicate times when $d\overline{\varepsilon}_T^\rho$ did not accumulate. This can be due to the material unloading into the elastic range, or actually plastically reverse loading with hydrostatic stress σ h < 0 as was demonstrated for an impact simulation. Similar observations were made from the simulation of a 2-degree-of-freedom mass-elastic-plastic-spring system subjected to impact.

36 MATERIALS SCIENCE↗

Impact of power flow on Z-pinch loads

Magnetically insulated transmission lines (MITLs) are used to deliver tens of MA to a Z-pinch load. The MITLs suffer current losses due to contaminant plasma located in the anode–cathode gap which is swept toward the load along the power flow. The swept up contaminant plasma can deposit mass and energy onto the load resulting in deformations or the seeding of macroscopic instabilities. This paper discusses 2D fully kinetic simulations of the contaminant plasma evolution which predict the current losses and the flux of mass and energy onto the load. Furthermore, the effects of a dynamic, i.e., imploding, load are shown to increase both the current loss and the mass and energy flux. The MITL used is a conical, radially converging design which is a feature common to MA-scale Z-pinch accelerators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

U.S. Distribution Transformer Demand Phase III - Key Drivers and Managing Demand [Slides]

This presentation demonstrates a significant analysis, on forecasting the demand for distribution transformers. The analysis is conducted for the United States, estimating the initial in-service capacity of these assets, and forecasting demand for these assets through 2050 with several sensitivities conducted. It examines not only demand for these assets, but importantly, how utility planning practices can impact the demand for theses assets in time. Under load growth scenarios, whether utilities practice like-for-like replacement strategies as failures occur, or whether they practice proactive up-sizing, anticipating electric load growth, can have major impacts on future demand. It also examines several other growth factors, such as the increasing demand for step-up transformers, which share many of the same characteristics as distribution transformers, and the demand for specific transformers for large project growth from data centers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinated Modeling of Electric Grid and Natural Gas Network Operations

Presentation based upon full report of a Colorado case study and coordination framework, which is available at https://www.nrel.gov/docs/fy20osti/77096.pdf. JISEA analysts Brian Sergi, Omar Guerra, and Bri-Mathias Hodge will present on recent JISEA work on coordination between the natural gas and electricity sectors. Power and gas are becoming increasingly interdependent but weren't designed to function together. How does greater coordination impact system operations with different levels of solar and wind penetrations? This free JISEA presentation will take place in a Webinar on Tuesday, May 11, 2021 at 12 p.m.: Learn how greater coordination between the natural gas and electricity sectors impacts system operations with different levels of solar and wind penetrations. Presentation information includes: Historical and projected data for natural gas consumption and power generation in the United States as demonstrated by 2014 East Coast Polar Vortex, 2021 Texas Winter Storm Uri. Showing coupling points, FERC identified need for better coordination, different levels of coordination (decision making and optimization control), coordination framework. Case study on Colorado Front Range, ramping requirements and gas nominations, real-time dispatch (June and December scenarios), results of analysis of impacts of coordination on unserved load. Total real-time gas offtakes by node, impacts on unserved gas, effect on CO2 emissions. Discussions on clusions drawn from Colorado Case study expanded co-simulation via HELICS, objectives of the HELICS+ natural gas use case, modeling of hydrogen blending, techno economic assessment of blending, and blending impacts on energy content and pressure.

analysis↗

Storage Requirements for Grid Integration of Marine Renewable Energy - a Parametric Study

Marine resources such as waves and tides house immense potential to serve as energy-rich sources of renewable power generation. They are known to be highly available,persistent and predictable in nature. Therefore, these can serve as one of the critical components for a primarily renewable energy-driven, resilient and robust future power grid. Although some inherent temporal characteristics of these resources lend themselves favorably to potential grid applications, the inclusion of storage allows the benefits and value streams to become realized more fully. In this paper, we present a framework for assessing impact of marine energy resources inclusion on the overall load generation balance and its impact on the relevant storage requirements to obtain the desired level of renewable energy penetration. From this study, we can critically infer two main points - (a) the relative storage requirements for grid operations with and without marine energy, and (b) the avoided cost of storage by including marine energy into the generation mix. We demonstrate our framework for two different locations across the United States.

Hanif, Sarmad↗