Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMAGE TUBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Effect of Tube-Based X-Ray Microtomography Imaging on the Amino Acid and Amine Content of the Murchison CM2 Chondrite

X-ray and synchrotron X-ray micro-computed tomography (micro-CT) are increasingly being used for three dimensional reconnaissance imaging of chondrites and returned extraterrestrial material prior to detailed chemical and mineralogical analyses. Although micro-CT imaging is generally considered to be a non-destructive technique since silicate and metallic minerals in chondrites are not affected by X-ray exposures at the intensities and wavelengths typically used, there are concerns that the use of micro-CT could be detrimental to the organics in carbonaceous chondrites. We recently conducted a synchrotron micro-CT experiment on a powdered sample of the Murchison CM2 carbonaceous chondrite exposed to a monochromatic high energy (approximately 48 kiloelectronvolts) total X-ray radiation dose of approximately 1 kilogray (kGy) using the Advanced Photon Source beamline 13-BMD (13-Bending Magnet-D Beamline) at Argonne National Laboratory and found that there were no detectable changes in the amino acid abundances or enantiomeric compositions in the chondrite after exposure relative to a Murchison control sample that was not exposed. However, lower energy bremsstrahlung X-rays could interact more with amino acids and other lower molecular weight amines in meteorites. To test for this possibility, three separate micro-CT imaging experiments of the Murchison meteorite using the GE Phoenix v/tome/x s 240 kilovolt microfocus high resolution tungsten target X-ray tube instrument at the American Museum of Natural History (AMNH) were conducted and the amino acid abundances and enantiomeric compositions were determined. We also investigated the abundances of the C1-C5 amines in Murchison which were not analyzed in the first study.

Microtomography Imaging↗

Rays for Roots - Integrating Backscatter X-Ray Phenotyping, Modeling and Genetics to Increase Carbon Sequestration and Switchgrass Resource Use (Final Report)

To increase carbon (C) deposition in the soil and enhance crop resource use efficiency, characterizing root form and function is essential. Several root and soil traits have been linked to increased root-to-soil C transfer. Technology that could provide high-resolution characterization of many of these traits in field conditions would revolutionize our ability to study and understand how to increase C sequestration. In this effort, we developed an initial early prototype backscatter X-ray system for non-destructive imaging of root traits. We collected initial backscatter X-ray data in field and lab settings and carried out early analysis of these data. Along with this prototype, we also developed a suite of root phenotyping approaches including advanced minirhizotron image analysis, soil core imaging, and mesocosm imaging. Minirhizotron (MR) tubes are clear tubes inserted into the soil in the field and used to image roots and the surrounding soil. Our team has developed deep learning-based methods that can segment roots from soil that can learn from imprecise image-level labels. The ability to learn or fine-tune our deep learning algorithms from image-level labels allows easier and faster application of these approaches to new locations and new plant species. We have successfully implemented and applied our MR analysis approaches to thousands of switchgrass MR images collected across geographical regions. An advantage of MR imaging is the ability to collect root and soil images over time. Our soil core analysis included collecting hundreds of soil core samples from harvested switchgrass fields and imaging these cores with both X-ray CT and backscatter X-ray imaging. Initial segmentation approaches for the X-ray CT images of these cores have been developed and applied. An advantage of soil core analysis is that it preserves the three-dimensional structures of the roots and soil in the core collected. Our group also developed photogrammetry-based mesocosm root imaging and phenotyping approaches. In this approach, a plant was grown in a large mesocosm with a three-dimensional grid of thin supporting lines inserted throughout the mesocosm. After the plant (and, correspondingly, the root architecture is grown and established) the soil media was removed and the supporting lines approximately preserved the three-dimensional root architecture. Then, we applied photogrammetry techniques to create a three-dimensional digital representation of the root architecture for which we developed analysis algorithms including skeletonization. We carried out our phenotyping development with powerful switchgrass resources and physiological and agroecosystem modeling to deliver novel technology. This project contributes to multiple ARPA-E missions including reduction of foreign imports of energy, reduction of energy-related emissions including greenhouse gases, and ensuring that the United States maintains a technological lead in developing and deploying advanced energy technology. Furthermore, the developed tools could transform public and private plant breeding and could be broadly applicable to other crops and, potentially, other application areas. Our team of engineers, plant and soil scientists, and modelers i) developed an early prototype backscatter X-ray platform that can operate in field conditions; ii) developed a suite of root phenotyping and characterization approaches as described above; iii) developed and carried out plant biology and physiology roots studies and; iv) developed and implemented mechanistic physiological modeling.

42 ENGINEERING↗

Robotic System Would Inspect Tubes And Fillets

Proposed robotic system inspects arrays of brazed tubes being fabricated for use in heat exchangers and similar objects. Arrays contain coolant tubes mounted in nozzle of main engine of Space Shuttle. Other versions used to inspect components of terrestrial heat exchangers for powerplants, vehicles, and refrigeration equipment. Inspection system provides for automated, complete, objective, and efficient inspection of arrays of coolant tubes. Computer executing image-processing algorithms extracts profiles of tubes and braze fillets and identifies flaws.

Gilbert, Jeffrey L.↗

Imaging Fluorescent Combustion Species in Gas Turbine Flame Tubes: On Complexities in Real Systems

Planar laser-induced fluorescence (PLIF) is used to visualize the flame structure via OH, NO, and fuel imaging in kerosene- burning gas turbine combustor flame tubes. When compared to simple gaseous hydrocarbon flames and hydrogen flames, flame tube testing complexities include spectral interferences from large fuel fragments, unknown turbulence interactions, high pressure operation, and the concomitant need for windows and remote operation. Complications of these and other factors as they apply to image analysis are considered. Because both OH and gas turbine engine fuels (commercial and military) can be excited and detected using OH transition lines, a narrowband and a broadband detection scheme are compared and the benefits and drawbacks of each method are examined.

Hicks, Y. R.↗

Atmospheric Emission Photometric Imaging on Spacelab (AEPI)

Two parallel detector systems are used for atmospheric emission photometric emission. The top system is a TV system using the image intensified S.E.C. tube as the detector. The bottom system, the photon counting array (P.C.A.), uses a microchannel plate intensified anode array tube and is equivalent to a 100 channel photomultiplier. For the television, the filters are selected by means of a filter wheel set. The field of view of the is interchangeable between 20 and 6 degrees, by means of a moveable prism. The quartz window mu channel plate intensifier is fiber optically coupled to a 40-25 demagnifying tube which is in turn coupled to the S.E.C. tube. The PCA channel has a fixed field of view of 4 deg and a remote control interchangeable photometric converter optics which converts the imaging array into a multichannel photometer. The mu channel plate array tube amplifies the photons into detectable counts for the PCA electronics. The entire system is pointed by a two axis gimbal. The flight equipment to be acquired consists of a gyro package and an interactive flight control unit panel. The gyro package is necessary because of the inadequate attitude reference supplied by the current Spacelab systems.

Mende, S. B.↗

Neutron-image intensifier

Electronic intensifier tube with a demagnification ratio of 9-1 enhances the usefulness of neutron-radiographic techniques. A television signal can be obtained by optical coupling of a small-output phosphor-light image to a television camera.

Berger, H.↗

Electronic magnification for astronomical camera tubes

Definitions, test schemes, and analyses used to provide variable magnification in the image section of the television sensor for large space telescopes are outlined. Experimental results show a definite form of magnetic field distribution is necessary to achieve magnification in the range 3X to 4X. Coil systems to establish the required field shapes were built, and both image intensifiers and camera tubes were operated at high magnification. The experiments confirm that such operation is practical and can provide satisfactory image quality. The main problem with such a system was identified as heating of the photocathode due to concentration of coil power dissipation in that vicinity. Suggestions for overcoming this disadvantage are included.

Vine, J.↗

Thermographic Imaging of Material Loss in Boiler Water-Wall Tubing by Application of Scanning Line Source

Localized wall thinning due to corrosion in utility boiler water-wall tubing is a significant inspection concern for boiler operators. Historically, conventional ultrasonics has been used for inspection of these tubes. This technique has proven to be very manpower and time intensive. This has resulted in a spot check approach to inspections, documenting thickness measurements over a relatively small percentage of the total boiler wall area. NASA Langley Research Center has developed a thermal NDE technique designed to image and quantitatively characterize the amount of material thinning present in steel tubing. The technique involves the movement of a thermal line source across the outer surface of the tubing followed by an infrared imager at a fixed distance behind the line source. Quantitative images of the material loss due to corrosion are reconstructed from measurements of the induced surface temperature variations. This paper will present a discussion of the development of the thermal imaging system as well as the techniques used to reconstruct images of flaws. The application of the thermal line source coupled with the analysis technique represents a significant improvement in the inspection speed for large structures such as boiler water-walls. A theoretical basis for the technique will be presented which explains the quantitative nature of the technique. Further, a dynamic calibration system will be presented for the technique that allows the extraction of thickness information from the temperature data. Additionally, the results of applying this technology to actual water-wall tubing samples and in situ inspections will be presented.

Cramer, K. Elliott↗

Polarized $\mathrm{NORTIA}$ accumulation in response to pollen tube arrival at synergids promotes fertilization

Signal-mediated regulation of protein trafficking is an elegant mechanism for controlling the delivery of molecules to a precise location for critical signaling events that occur over short time frames. During plant reproduction, the FERONIA receptor complex is critical for intercellular communication that leads to gamete delivery; however, the impact of the FERONIA signal transduction cascade on protein trafficking in synergid cells remains unknown. Live imaging of pollen tube reception has revealed that a key outcome of FERONIA signaling is polar accumulation of the MLO protein NORTIA at the filiform apparatus in response to signals from an arriving pollen tube. Artificial delivery of NORTIA to the filiform apparatus is sufficient to bypass the FERONIA signaling pathway and to promote interspecific pollen tube reception. We propose that polar accumulation of NORTIA leads to the production of a secondary booster signal to ensure that pollen tubes burst to deliver the sperm cells for double fertilization.

59 BASIC BIOLOGICAL SCIENCES↗

Rendering Three-Dimensional Solar Coronal Structures

An X-ray or EUV image of the corona or chromosphere is a 2D representation of an extended 3D complex for which a general inversion process is impossible. A specific model must be incorporated in order to understand the full 3D structure. We approach this problem by modeling a set of optically-thin 3D plasma flux tubes which we render these as synthetic images. The resulting images allow the interpretation of the X-ray/EUV observations to obtain information on (1) the 3D structure of X-ray images, i.e., the geometric structure of the flux tubes, and on (2) the internal structure using specific plasma characteristics, i.e., the physical structure of the flux tubes. The data-analysis technique uses magnetograms to characterize photospheric magnetic fields and extrapolation techniques to form the field lines. Using a new set of software tools, we have generated 3D flux tube structures around these field lines and integrated the plasma emission along the line of sight to obtain a rendered image. A set of individual flux-tube images is selected by a non-negative least-squares technique to Provide a match with an observed X-ray image. The scheme minimizes the squares of the differences between the synthesized image and the observed image with a non-negative constraint on the coefficients of the brightness of the individual flux-tube loops. The derived images are used to determine the specific photospheric foot points and physical data, i.e., scaling laws for densities and loop lengths. The development has led to Computer efficient integration and display software that is compatible for comparison with observations (e.g., Yohkoh SXT data, NIXT, or EIT). This analysis is important in determining directly the magnetic field configuration, which provides the structure of coronal loops, and indirectly the electric currents or waves, which provide the energy for the heating of the plasma. We have used very simple assumptions (i.e., potential magnetic fields and isothermal corona) to provide an initial test of the techniques before complex models are introduced. We have separated the physical and geometric contributions of the emission for a set of flux tubes and concentrated, in this initial study, on the geometric contributions by making approximations to the physical contributions. The initial results are consistent with the scaling laws derived from Yohkoh SXT data.

Gary, G. Allen↗

Photometric imaging of Mars during the 1973 opposition

The paper discusses imaging of Mars at 20 wavelengths in the spectral region from 0.35 to 1.10 microns performed during the 1973 opposition with a photometric imaging system that uses a silicon vidicon tube as the detector. The imaging system and data-reduction procedures are described in detail, and relative reflectance spectra for several small areas in the images are presented along with vidicon images obtained during early phases in the development of the 1973 dust storms. Several anomalous blue brightenings are examined and attributed to ground fog and H2O frost. It is suggested that anomalously large amounts of H2O were pulsed into the atmosphere from the regolith by the storm system. An apparent fading and recession of the north polar hood is noted, surface units revealed in contrast-enhanced ratio images are identified, and the need for higher-spatial-resolution orbital spectroscopy of dark areas is emphasized.

Mccord, T. B.↗

Density variance dynamics in disparate shock tubes

This report discusses two experiments which investigate thin layer, heavy curtain fragmentation from the perspective of a Reynolds-Averaged mix model, in drastically disparate experimental regimes. The first, the centimeter/millisecond-scale “Horizontal Shock Tube” (HST) is a compressed-gas piston-driven shock tube experiment. The second, the “Multishock thin layer” (Mshock) experiment performed at the National Ignition Facility, is a micrometer/nanosecond-scale laser-driven shock tube experiment. Both are situations in which a heavy plane layer (a ‘curtain’) is initially suspended in a lighter medium. After being shocked from at least one side, the layer translates while its interfaces evolve due to the excitation of the Richtmyer-Meshkov instability at its surfaces. The evolution of density variance, which initially exists only on the surface of the layer, as it comes to encompass the whole layer interior is used as a description of layer fragmentation and dissolution. These experiments have each been simulated in the Los Alamos National Laboratory multi-physics code xRAGE, which includes fundamental hydrodynamics, extended plasma physics and radiation effects which are important to drive the high-energy density experiment, and the Besnard-Harlow-Rauenzahn (BHR) turbulence model. In each, the principal diagnostic for comparison is an experimental metric for the density (co)variance, b, which tracks the moments of the density field at the curtain interfaces and body. Due to experimental constraints in different regimes (i.e. optical diagnostics can be deployed on conventional shock tubes, while the plasma shock tubes must be imaged by x-rays; interfaces can be imposed to specification on laser-driven experiments, which are stored in the solid phase, while conventional experiments have imperfect control of the flow fields which separate the layer, etc.) the experiments are not designed to be perfect scaled cognates of one another. However, despite the separation of six orders of magnitude of scaling in time, and four in space, we are able to demonstrate that the same turbulence model, operating in the same fashion in the same computer code, is able to reproduce results in each experiment, by tracking evolution due to common relevant physics. Additionally, we will present preliminary work toward density variance comparisons in a single-interface Richtmyer-Meshkov configuration, the conventional fluid “Vertical Shock Tube” (VST) experiment, and the Modal Initial Conditions (ModCons) campaign fielded at the OMEGA-EP laser facility.

42 ENGINEERING↗

Observation of asymmetric explosive density evolution in the deflagration-to-detonation transition for porous explosives

We report deflagration-to-detonation transition phenomena in cylindrical columns of porous explosives based on octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX). The HMX powder and LX-14 (95.5 wt. % HMX and 4.5 wt. % estane polyurethane) prills were observed with high-speed cameras and flash x rays under conditions that allow for precise scaling and registration of the recorded images. These experimental results test the conventional assumption of axisymmetric, effective one-dimensional burning. Polycarbonate confinement tubes allowed this direct imaging with steel spheres employed as radio-opaque fiducials. Spheres embedded in the explosive column revealed the displacement of the explosive prior to deflagration. X-ray and fast camera images show that a dense plug of compact explosive develops ahead of the deflagration front. The internal fiducials register both internal changes in the plug and changes in the position between successive x-ray images. Tantalum witness strips placed on the inner wall of the explosive channel revealed radial expansion of the tube bore at successive x-ray exposures, indicating the internal pressure of about 100 MPa just before detonation. Images indicate that the deflagration is not only asymmetric but also involves newly observed transient phenomena just before detonation. Furthermore, we typically see a brief but continuous increase in deflagration speed and the formation of a deflagration channel that bypasses the plug just prior to detonation. We hypothesize that these phenomena play an important role in the deflagration-to-detonation transition itself.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗