Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IEEE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Introducing the 9500 Node Distribution Test System to Support Advanced Power Applications: An Operations-Focused Approach

The 9500 Node Test System is a representative section of distribution power system model developed as a part of the GridAPPS-D™ project, an effort funded by DOE as a part of the Grid Modernization Lab Consortium (GMLC) program. The test system was developed to fulfill a growing need to represent the rapidly evolving state of electric distribution systems by combining elements of legacy infrastructure systems, modern feeder topologies, and an anticipated future with smart grid technologies. It also provides a network model capable of supporting the simulation of operational scenarios such as the ones in a utility distribution control center. This test system allows the evaluation of the performance of advanced power applications in real-time, such as one that simulates the operations of an Advanced Distribution Management Systems (ADMS), Distributed Energy Resource Management Systems (DERMS), etc. in a Distribution control center. This model is an extension of the widely used IEEE 8500 Node Test Feeder and is currently being validated to become an IEEE test case to help increase adoption and widespread usage among both academia and industry. It is a full-size model representative of a section of a utility’s distribution system with multiple feeders fed from different substations. The model includes multiple distribution circuits, a sub-transmission system, multiple substations, behind the meter customer rooftop photovoltaics (PV), and multiple utility-scale distributed energy resources. To enable accurate simulations of operational scenarios, the 9500 Node Test System is designed to support procedure-based operations, with the ability to realistically demonstrate switching operations, feeder reconfiguration, adjustment of volt-var control equipment, dispatch of distributed generation, and response to planned and unplanned outages. The 9500 Node Test System includes three radial distribution feeders with 12.3 MVA of average load, consisting of both medium voltage and low voltage equipment each supplied by a different distribution substation. The three distribution feeders are connected to each other through Normally-Open switches which can be closed when needed to simulate restoration scenarios due to a fault. One feeder represents today’s grid with low penetration of customer-side renewables. The second represents a potential future grid with microgrids and 100% renewable penetration. The third has no customer generation resources, a district steam plant, and a utility-scale solar farm. The three diverse circuits were created to allow the simulation of both today’s situation as well as potential future scenarios. All three feeders have customers connected by low-voltage secondary triplex lines. This test system meets all requirements outlined in the report for creating a simulation environment that would enable discussion between key technical stakeholders as well as having the potential to accelerate operational application development and their subsequent testing and integration. The new model is a possible representation of what we believe the distribution grid may look like in the future: a high penetration of renewables, reconfigurable radial and mesh topology, numerous DERs, islanded microgrids, and significantly increased data and measurement density. The system supports both the solution of existing and newer algorithms but also enables the evaluation of applications in a realistic operational environment defined by task oriented procedural steps that represent the interaction between the control center operator and field personnel.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SiC Based Modular Transformer-less MW-Scale Power Conditioning System and Control for Flexible CHP System

This project aims at developing a SiC-based, modular, transformer-less (60-Hz-transformers-free), MW-scale, four-wire DC/AC power conditioning system (PCS) converter, and a corresponding control system for flexible-CHP (F-CHP) systems. With the help of an F-CHP controller and power electronics converters, different CHP sources, renewable sources, and batteries can be assembled to the DC grid, which is then connected to the medium voltage (MV) AC grid through the PCS converter. To meet grid support and performance requirements, the F-CHP controller design and PCS converter design follow IEEE 1547 and IEEE 2030.7 standards. Five main tasks, including PCS converter design, F-CHP controller development, PCS converter prototype building and testing, F-CHP controller testing, and PCS paralleling, have been carried out. In this project, the F-CHP controller testing has been completed in simulation, HIL and HTB, and the PCS converter prototypes have been successfully built and tested.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Review of Distributed Wind Interconnection Technology and Standards

The objectives of this report are to discuss the uniqueness of power converters in distributed wind (DW), identify challenges in complying with existing standards, prioritize technological innovations to facilitate interconnection of DW energy systems, and, where necessary, propose potential clarifications or revisions to standards. This report evaluates IEEE 1547-2018, IEEE 1547.1-2020, and UL 1741 SB standards and their implications for DW. A standards review and interviews of DW industry stakeholders were conducted to identify challenges in the application of current standards to DW. The study concludes with a combination of recommendations of pathways towards facilitating DW product commercialization and DW interconnection, which draws on participation from multiple stakeholders in the space. These solutions can continue to be explored to improve DW standards compliance, improve the applicability of the standards to DW, reduce certification testing barriers, and ensure the safe and reliable operation of DW energy resources and electric power systems.

17 WIND ENERGY↗

Universal Passive Synchronization Method for Grid-Forming Inverters Without Mode Transition

Power systems are transforming with increasing levels of inverter-based resources (IBRs). This transformation requires critical roles of grid-forming (GFM) inverters replacing synchronous generators for bulk power system stabilization and ancillary services, also allowing flexible power system operation, such as microgrid that is operated by multiple GFM IBRs to achieve system resilience against contingencies. To realize the resilient power systems allowing flexible in-and-out operation of GFM IBRs potentially programmed with different primary controls, a synchronization method universally applicable, i.e., independent of control types, would be beneficial to ease the integration process, but it has not been actively studied. To fill the gap, this paper proposes a universal synchronization method that achieves a passive synchronization to enable a smooth transition in a grid with off-nominal system parameters, i.e., voltage and frequency. The logic proposed requires no modification on the primary control, thus applicable to any type of GFMs with a voltage reference input. To validate the concept, a simulation of an IEEE 13-bus benchmark system modified with 3 GFM inverters is presented. It simulates an inverter-driven black start scenario in which GFM inverters autonomously turn on and connect to the grid under heavy loading, using the synchronization logic. The case study demonstrates that GFM inverters can tune their voltage reference to smoothly synchronize without severe transients, and contribute to a seamless black start of the grid under unbalanced load conditions. Two GFM methods - Droop and dispatchable virtual oscillator control - are used for the demo to validate feasibility and interoperability of the passive synchronization.

black start↗

Protection Against Graph-Based False Data Injection Attacks on Power Systems

Graph signal processing (GSP) has emerged as a powerful tool for practical network applications, including power system monitoring. By representing power system voltages as smooth graph signals, recent research has focused on developing GSP-based methods for state estimation, attack detection, and topology identification. Included, efficient methods have been developed for detecting false data injection (FDI) attacks, which until now were perceived as non-smooth with respect to the graph Laplacian matrix. Consequently, these methods may not be effective against smooth FDI attacks. In this paper, we propose a graph FDI (GFDI) attack that minimizes the Laplacian-based graph total variation (TV) under practical constraints. In addition, we develop a low-complexity algorithm that solves the non-convex GDFI attack optimization problem using ell_1-norm relaxation, the projected gradient descent (PGD) algorithm, and the alternating direction method of multipliers (ADMM). We then propose a protection scheme that identifies the minimal set of measurements necessary to constrain the GFDI output to high graph TV, thereby enabling its detection by existing GSP-based detectors. Our numerical simulations on the IEEE-57 bus test case reveal the potential threat posed by well-designed GSP-based FDI attacks. Moreover, we demonstrate that integrating the proposed protection design with GSP-based detection can lead to significant hardware cost savings compared to previous designs of protection methods against FDI attacks.

Morgenstern, Gal↗

ModuleOT: A Hardware Security Module for Operational Technology: Preprint

With increasing penetration levels of distributed energy resources (DERs) on the distribution grid, as well as new technological advancements in the cyber space, new cyberattack vectors are being introduced, and the available attack surface is constantly increasing. Despite this increasing risk, the standard IEEE 1547-2018 does not yet recommend cybersecurity measures for DERs. To address this and to better protect data on the distribution grid - from the standpoints information security as well as operational security - ModuleOT has been developed. The module aims to significantly reduce cyberattack vectors by improving data privacy for user applications. This is accomplished by performing the core functions of encryption, authentication, authorization, certificate management, and user access control. The module integrates a custom security application with hardware cryptographic acceleration. The application secures all communications using Transmission Control Protocol over Internet Protocol (TCP/IP). These include the three most commonly used communications protocols for power systems information exchange: Modbus, Distributed Network Protocol 3 (DNP3), and Smart Energy Profile 2.0 (SEP2.0). These three protocols are also supported by IEEE 1547-2018 for all DER devices. This paper tests the data encryption/decryption feature on a physical networking test bed with emulated Modbus devices reporting grid data and presents the results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Aggregated PV on Subsynchronous Torsional Interaction

This paper investigates induced oscillation (specifically subsynchronous torsional interactions) in power systems arising from photovoltaic (PV) power modulation. Time domain simulations of a modified IEEE first-benchmark system are presented and analyzed. In the IEEE benchmark system, a PV generator was added at the same bus where the synchronous generator is connected. The impact of different parameters of the PV inverters’ volt-volt-ampere reactive (volt-var) curve on SSTI is examined. The most severe impact found arises from the time response of the inverter’s reactive power change. A second-order time response with natural frequency matching the rotor speed deviation oscillation frequency and low-damping ratio quickly drives the system to an unstable region. Although it is highly unlikely that conditions necessary for distributed energy resource-induced oscillations would occur in the field, with knowledge of this vulnerability in mind, inverters' control parameters can be designed to avoid it.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Grid Code Essentials and Streamlining Process for Interconnections

This presentation was part of a webinar entitled "A Practitioner's Guide to Implementing Solar Rooftop Programs and Navigating Net-Metering Policies," hosted by USAID Clean Power Asia and included speakers the Hawaii Natural Energy Institute as well as NREL. This presentation outlines grid codes in general, and IEEE Std 1547-2018 specifically, and discusses their adoption into interconnection requirements. Key capabilities, now enabled by IEEE Std 1547-2018, such as voltage regulation and frequency ride-through are described.

DER↗

Large-Scale Adoption of Self-Synchronized Universal Droop Controller-Based Inverters to Enable Ancillary Services for Different Modes of Distribution System Operations

This work proposes the large-scale adoption of self-synchronized universal droop controller (SUDC)-based inverters to enable ancillary services for different modes of distribution system operations. The IEEE 123 bus system was modeled on a real-time simulator to study the performance of large-scale adoption of SUDC inverters in a distribution system. The resulting data collected shows that the voltage and the frequency were regulated within ranges, such as less than 5% for voltage and less than 0.5% for frequency, under different load variations and grid operations. Also, the black start was achieved within 0.4 s without any voltage overshoot. Through the simulation and validation on a small microgrid and the IEEE 123 bus distribution system, it can be concluded that the SUDC was successfully adopted to regulate the voltage and the frequency within the given ranges, and black start achieved within 1 s without voltage overshoot for different modes of distribution system operations.

14 SOLAR ENERGY↗

Data Driven Online Learning of Power System Dynamics

With the advancement of sensing and communication in power networks, high-frequency real-time data from a power network can be used as a resource to develop better monitoring capabilities. In this work, a systematic approach based on data-driven operator theoretic methods involving Koopman operator is proposed for the online identification of power system dynamics. In particular, a new algorithm is provided, which unlike any previously existing algorithms, updates the Koopman operator iteratively as new data points are acquired. The proposed algorithm has three advantages: a) allows for real-time monitoring of the power system dynamics b) linear power system dynamics (this linear system is usually in a higher dimensional feature space and is not same as linearization of the underlying nonlinear dynamics) and c) computationally fast and less intensive when compared to the popular Extended Dynamic Mode Decomposition (EDMD) algorithm. The efficiency of the proposed algorithm is illustrated on an IEEE 9 bus system using synthetic data from the nonlinear model and on IEEE 39 bus system using synthetic data from the linearized model.

Sinha, Subhrajit↗

A Computationally Improved Heuristic Algorithm for Transmission Switching Using Line Flow Thresholds for Load Shed Reduction

We present a computationally improved heuristic algorithm for transmission switching (TS) to recover load shed. Research from the past showed that changing power system topology may control power flows and remove line congestion. Hence, TS may reduce the required load shed. One of the main challenges is to find a potential TS candidate in a suitable time. Here, we propose a novel heuristic method that is capable of finding the potential TS candidate faster than existing algorithms in literature. The proposed method is compatible with both the AC and DC optimal power flows (OPF). Three metrics are used to compare the proposed algorithm with the state-of-the-art from literature to show the speedup and accuracy achieved. The proposed method is implemented on the IEEE 30-bus system, PEGASE 89-bus system, IEEE 118-bus system, and Polish 2383- bus system. The results on the large-scale Polish 2383-bus system shows that the proposed algorithm is scalable to large real-world systems. Parallel computing is implemented to further improve the computational performance of the proposed algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Privacy-Preserving Strategy for the Trust Layer of the Energy Grid of Things Distributed Energy Resource Management System

Emergent from the shadows of the traditional grid flaws, the Smart Grid (SG) idea was born and led by government mandates toward cleaner energy production. The SG represents the next generation of electricity distribution systems that subsume recent technological innovations. It uses digital communication between its components and entities to attain more automation, self-sufficiency, and reliability. Unfortunately, this relatively new concept is not flawless; the intrinsic reliance on increased digital communication spreads open attack paths for adversaries. Therefore, finding solutions that address information exchange vulnerabilities has become imperative. The Energy Grid of Things (EGoT) is Portland State University’s (PSU’s) implementation of a Distributed Energy Resource Management System (DERMS). The EGoT DERMS requires access to customers’ information to achieve operational objectives. The system’s access to customers’ information needs to be restricted such that it does not violate customers’ privacy. Applying privacy protection models such as K-anonymity to EGoT DERMS sub-components safeguards that privacy. This thesis work proposes a strategy to ensure communication in the EGoT DERMS is privacy-preserving and secure. Specifically, it provides an approach to applying the Mondrian Algorithm to ensure data within the system excludes Personally Identifiable Information (PII) and provides means for securing the communication according to industry standards (IEEE 2030.5). Results suggest that the generalization hierarchy derived for the EGoT DERMS exhibits an Identical Generalization Hierarchy structure. Guarantees of sameness manifested in the test feeder topology would not hold in real-world scenarios. This thesis work proposes a strategy to ensure communication in the EGoT DERMS is privacy-preserving and secure. Specifically, it provides an approach to applying the Mondrian Algorithm to ensure data within the system excludes Personally Identifiable Information (PII) and provides means for securing the communication according to industry standards (IEEE 2030.5). Results suggest that the generalization hierarchy derived for the EGoT DERMS exhibits an Identical Generalization Hierarchy structure. Guarantees of sameness manifested in the test feeder topology would not hold in real-world scenarios.

Alsiad, Mohammed↗

Standardization of Smart Contracts for Energy Markets and Operation

This work presents a formal review of smart contracts, including definitions, technical requirements, and potential power and energy-related use cases. This includes in-depth discussions covering cybersecurity, legality and interoperability goals that must be taken into consideration by potential end-users. The paper presents a first attempt towards the standardization of smart contracts (SCs) within the field of power and energy as a work in progress activity under the IEEE Standards Association (IEEE SA) P2418.5 Working Group. This work also proposes a holistic, language-agnostic reference model that is intended to accelerate the adoption of Distributed Ledger Technology (DLT) by industry stakeholders by providing standardized processes. Finally, the paper discusses key takeaways that must continue to be developed to increase SC usage within the energy industry.

Blockchain, smart contracts, DLT↗

Development and Refinement of DER Steady State Model for QSTS Analysis

EPRI formed a working group of utilities and software vendors called the Distribution Advanced PV Model Working Group (DAWG). The working group has been focused on building consensus regarding the models that represent the reactive power capabilities outlined in Section 5 of IEEE Std 1547™-2018. This report provides an overview of the reactive and active power capabilities specified in IEEE Std 1547™-2018 and outlines a specification of key functions for usage during steady state snapshot and time series power flow analysis. Additionally, it presents a framework for performing tests to verify the correct operation of functions during power flow analysis.

14 SOLAR ENERGY↗

Efficient Network Partitioning: Application for Decentralized State Estimation in Power Distribution Grids: Preprint

Increase in the proliferation of DERs requires real-time situational awareness for efficient grid operations. State estimation plays an important role for real time control and management of the power grid. As the sensing infrastructure grows, aggregating and handling high volumes of data at a centralized location is extremely difficult. To address this challenge, this paper first proposes a novel and efficient hierarchical spectral clustering-based network partition algorithm followed by a decentralized compressive sensing (DCS) based state estimation. The applicability of the proposed network partitioning algorithm is tested on IEEE-123 bus, IEEE-8500 node, and a 6204-node distribution network. The results shows that the proposed approach efficiently divides the network into multiple sub-networks with the minimum edge connections among the neighbors. Then, we perform DCS-based state estimation on the 6204-node distribution network after dividing the network into 18 optimal partitions. Simulation results show that DCS-based state estimation recovers the system states with high accuracy and low complexity.

ADMM↗

Sensitivity-Based Reactive Power Dispatch of DERs to Support Transmission Grid During Emergency

This paper proposes a TSO-DSO framework including DER set-point dispatch using sensitivity analysis. We address all three steps of TSO-DSO integration stating by estimating the capability curve of an unbalanced distribution system and then modeling of capability curve on the transmission side grid and estimating the reactive power needed from DSO during emergencies, and ending by dispatching the requested reactive power from TSO. The proposed interaction framework is tested on an IEEE 37-node distribution network connected to IEEE 9 bus transmission system. The simulation shows that using sensitivity-based dispatch would reduce the number of communication signals between DERs and DSO and that can decrease the risk of communication contingency.

Alkhonain, Ahmed↗

Sample IEEE123 Bus system for OEDI SI

Time series load and PV data from an IEEE123 bus system. An example electrical system, named the OEDI SI feeder, is used to test the workflow in a co-simulation. The system used is the IEEE123 test system, which is a well studied test system (see link below to IEEE PES Test Feeder), but some modifications were made to it to add some solar power modules and measurements on the system. The aim of this project is to create an easy-to-use platform where various types of analytics can be performed on a wide range of electrical grid datasets. The aim is to establish an open-source library of algorithms that universities, national labs and other developers can contribute to which can be used on both open-source and proprietary grid data to improve the analysis of electrical distribution systems for the grid modeling community. OEDI Systems Integration (SI) is a grid algorithms and data analytics API created to standardize how data is sent between different modules that are run as part of a co-simulation. The readme file included in the S3 bucket provides information about the directory structure and how to use the algorithms. The sensors.json file is used to define the measurement locations.

123 bus↗

Development of an integrated platform for hardware-in-the-loop evaluation of microgrids prior to site commissioning

This paper presents an integrated hardware-in-the-loop (HIL) platform for testing the operation and control of a real-world microgrid system prior to site commissioning. The proposed testing approach shows the value of setting up an integrated HIL platform to test multiple hardware devices (including the system-level controller, device controllers, and field devices). A test bed developed for the Borrego Springs community microgrid is used as an example to demonstrate the feasibility of the integrated platform. Comprehensive tests are carried out using the Borrego Springs test bed to validate the platform, meet the test objectives, and gain valuable insight prior to site commissioning. The selected test scenarios, initial conditions, events, test metrics, etc., are similar to those defined in IEEE P2030.8. The test objectives are to evaluate the microgrid controller and the operation of the microgrid. The HIL platform presented in this paper shows good value for microgrid testing in terms of its flexibility and scalability for testing various microgrids; its accuracy in its representation of the field; the comprehensiveness of the testing capability; and the efficiency of testing, which can reduce risks prior to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗