Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IBR Model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

192 records · Page 11

Grid Operator Analytics and Assessment Tools for Inverter- Based Resources Dominated Grid (GOAAT-IBR) Project Update

This presentation provides an update on the OPTIMA GOAAT project, with emphasis on the cloud-native data platform developed in-house to ingest, manage, and operationalize high-resolution power system data. Since our last NASPI presentation, accessible via OSTI ID #2671437, the project team advanced the design and deployment of a scalable architecture capable of handling both synchronized and non-synchronized streams, including PMU, point-on-wave (POW), COMTRADE, and SCADA data. These materials review the project status, recent progress, and key lessons learned. The core of the presentation examines the architecture and engineering of our cloud-native ingestion and data management platform. We then explain how pipelines were designed to collect, normalize, time-align, store, and serve heterogeneous data at scale. We will discuss design choices such as data models, streaming versus batch ingestion, storage tiers, and interoperability with analytics applications. Practical experiences with cloud-native technologies were shared during the event, including benefits, limitations, and integration challenges in a utility environment, along with methods used to improve performance, reduce latency, and optimize resource usage. The presentation also showcases user interface designs and visualization tools that convert raw measurements and analytics results into intuitive, actionable insights for operators and engineers. During the presentation examples were provided demonstrating how visualization, event views, and summarized analytics enhance situational awareness and support operational decision-making. These use cases illustrate how a well-designed data infrastructure can bridge the gap between high-volume measurements and practical grid operations.

Aminifar, Farrokh↗

Parallel Grid-Forming Inverter-Driven Black Start: Power-Hardware-in-the-Loop Validation: Preprint

With power systems encountering increasing deployment levels of inverter-based resources (IBRs), system restoration using grid-forming (GFM) IBRs has gained attention. Engineered to establish grid voltages in the absence of a stiff grid, black-start-capable GFM IBRs are expected to enhance power system resilience by playing a critical role in bottom-up system restoration. This paper experimentally studies the feasibility of the novel approach through power-hardware-in-the-loop (PHIL) testing and validation with a commercial GFM inverter. The PHIL test setup demonstrates an inverter-driven black start of a 5-MW unbalanced distribution feeder where two GFM inverters collectively black start the feeder: one is a commercial hardware GFM inverter interacting through the PHIL interface, and the other is a software GFM emulated by a real-time simulation with full electromagnetic transient (EMT) models. Both GFM inverters are equipped with negative-sequence voltage control to suppress the voltage imbalance resulting from the unbalanced loading, allowing us to study the dynamic interactions between the GFMs with their control parameters unknown. To evaluate the dynamic behavior of the GFM inverters under the entire black-start process, the EMT model of the distribution system details the transformer and motor dynamics to emulate their inrush and startup behaviors. It abstracts conventional grid-connected inverter dynamics, i.e., grid-following inverters. Oscilloscope measurements of the hardware GFM inverter are also presented for critical steps. Takeaways for further study and field deployment are provided.

grid-forming inverter↗

Predicting kinase inhibitors using bioactivity matrix derived informer sets

Prediction of compounds that are active against a desired biological target is a common step in drug discovery efforts. Virtual screening methods seek some active-enriched fraction of a library for experimental testing. Where data are too scarce to train supervised learning models for compound prioritization, initial screening must provide the necessary data. Commonly, such an initial library is selected on the basis of chemical diversity by some pseudo-random process (for example, the first few plates of a larger library) or by selecting an entire smaller library. These approaches may not produce a sufficient number or diversity of actives. An alternative approach is to select an informer set of screening compounds on the basis of chemogenomic information from previous testing of compounds against a large number of targets. We compare different ways of using chemogenomic data to choose a small informer set of compounds based on previously measured bioactivity data. We develop this Informer-Based-Ranking (IBR) approach using the Published Kinase Inhibitor Sets (PKIS) as the chemogenomic data to select the informer sets. We test the informer compounds on a target that is not part of the chemogenomic data, then predict the activity of the remaining compounds based on the experimental informer data and the chemogenomic data. Through new chemical screening experiments, we demonstrate the utility of IBR strategies in a prospective test on three kinase targets not included in the PKIS.

59 BASIC BIOLOGICAL SCIENCES↗

Decentralized Microgrid Protection Through Relative Fault Direction Classification: Preprint

Protection in inverter-based resources (IBRs) dominated microgrids generally face significant challenges due to the low fault current and inconsistent fault behaviors from IBRs. Recently, machine learning-based approaches have attracted considerable attention to address these challenges. This paper introduces a novel decentralized protection strategy for microgrids. The proposed method decomposes the protection challenge into several distributed learning tasks, enabling individual relays to autonomously determine the direction of faults using a binary classification framework based on support vector machine (SVM) algorithms. Following the distributed fault direction estimation, classifier outcomes are shared among neighboring relays, facilitating a local decision-making process to ascertain the presence of faults within the neighborhood. Finally, a tripping signal is generated based on the classifier results of each relay to operate the circuit breaker. To test and validate this approach, a 100% renewable microgrid model is simulated in MATLAB/Simulink. In the numerical analysis, the application of SVM classifiers in our approach yields impressive results: an average relay classification accuracy of 98%, and a 96% accuracy in circuit breaker control. These findings highlight the potential of machine-learning-based approaches in enhancing the efficiency and reliability of microgrid protection systems.

decentralized algorithm↗

Cyber-Resilient Automatic Generation Control for Systems of AC Microgrids

In this paper we propose a co-design of the secondary frequency regulation in systems of AC microgrids and its cyber security solutions. We term the secondary frequency regulator a Micro-Automatic Generation Control (μ AGC) for highlighting its same functionality as the AGC in bulk power systems. We identify sensory challenges and cyber threats facing the μ AGC. To address the sensory challenges, we introduce a new microgrid model by exploiting the rank-one deficiency property of microgrid dynamics. This model is used to pose an optimal μ AGC control problem that is easily implemented, because it does not require fast frequency measurements. An end-to-end cyber security solution to the False Data Injection (FDI) attack detection and mitigation is developed for the proposed μ AGC. The front-end barrier of applying off-the-shelf algorithms for cyber attack detection is removed by introducing a data-driven modeling approach. Finally, we propose an observer-based corrective control for an islanded microgrid and a collaborative mitigation scheme in systems of AC microgrids. We demonstrate a collaborative role of systems of microgrids during cyber attacks. Furthermore, the performance of the proposed cyber-resilient μ AGC is tested in a system of two networked microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving Frequency Stability and Minimizing Load Shedding Events by Adopting Grid-Scale Energy Storage with Grid Forming Inverters

The upward adoption trend of renewable generation not only means cleaner energy integrated into modern power grids, but also that most new generation sources are based on front-end inverter bridges, used as interfaces to most wind generation and all the solar PV. It is well known that due to their power electronics-based construction rather than rotational shafts, these sources do not provide inertia inherently, nor substantial amounts of short-circuit currents. However, stable energy such as what can be stored in energy storage systems, although interfaced via inverters, can be controlled to respond to system disturbances in a manner that emulates inertial behavior. This paper focuses on the application of such energy storage systems to augment inertia in the island of Puerto Rico. To do so, a user defined inverter model that contains grid forming capabilities and fast frequency response is modeled and integrated into the real transmission system in power flow and dynamics software. Energy storage is then connected to two selected areas so that it not only provides frequency regulation to avoid widespread load shedding events, but also other tangible benefits. The simulated cases suggest that even relatively small energy storage systems can avert load shedding events if adequately placed in the transmission network.

Grid-forming inverters, IBR, Inertia↗

ReNew100: Reliable Power System Operation with 100% Renewable Generation

The ReNew100 project has developed and demonstrated an operator support system (OSS) to operate power systems with 100% renewable power generation from inverter-based resources (IBRs) like wind and solar that significantly reduces the risk of widespread power outages in a simulated operational environment at Technology Readiness Level (TRL) 6. The OSS achieves resilient operation for power systems under changing operation modes including varying combinations of conventional and renewable generation, including cases with 100% renewable generation from wind and solar IBRs. The OSS continuously monitors the N-1 security of the power system, which refers to the ability of the power systems to survive single outages of power system elements, like the loss of a generator or a power line, without causing widespread power outages beyond those expected and planned for. If the OSS identifies that the system is not N-1 secure, an automatic Controller Parameter Optimization (CoPO) developed within Renew100 is activated to optimize the N-1 security of the system by tuning controller parameters within different assets like batteries, wind, and solar plants. The core innovation of ReNew100 is the development of this CoPO as well as the demonstration of the OSS for a real-time simulation of the Hawai'i Island power system. Moreover, Renew100 has developed new model calibration techniques for dynamic power system models and demonstrated them for Hawai'i Island.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Testing GFM and GFL Inverters Operating With Synchronous Condensers

Inverter-based resources (IBRs) are quickly evolving into a source of reliability services to the electric grid. Penetration levels of variable generation are rapidly increasing, ranging from 60% -70% in some systems. To go further, a fundamental shift is required to address challenges associated with grid stability. Synchronous condensers (SCs) are considered an important complementary technology in such transitions. This paper provides one-of-a-kind insights into real experimental results from operating a real MW-scale system consisting of a 2.2-MVA grid-forming (GFM) and grid-following (GFL) battery energy storage system, 2.5-MVA SCs, and a 3-MVA load bank operating as a small, islanded grid. Challenges that are expected in larger systems were mimicked in this small but real system to demonstrate seamless transitions from one mode to another as well as stable operation with different combinations of GFM and GFM resources, including a "loss of last synchronous generator" case. The experimental results presented in this paper are a valuable resource to everyone involved in developing and validating models or developing controls of power systems consisting of inverters and synchronous condensers.

grid-following converter↗

Innovative Gasification to Produce Fischer-Tropsch Jet and Diesel Fuel

The primary objective of this project and the U.S. DOE’s integrated biorefinery (“IBR”) program was to demonstrate conversion of biomass and waste-derived feedstocks into military spec liquid fuels. Frontline’s proposed integrated process was to incorporate several novel technologies and innovative applications of existing technologies that would serve both to increase plant efficiency and also to lower the cost of the produced biofuels. The project was intended to demonstrate Frontline Bioenergy’s technologies for gasification and synthesis gas clean-up configuration to produce a syngas stream suitable for a proven Fischer-Tropsch (“F-T”) unit that would produce F-T intermediate products. These F-T intermediate products were to be upgraded to military spec diesel and jet fuel, including F76, JP5, and JP8. Specifically, these technologies consisted of: 1. Frontline’s PMFreeGas® ultra low particulate matter (PM) hot gas filtration technology 2. Application of Frontline’s TarFreeGas® ultra low-tar gasification technology 3. Frontline’s novel approach to syngas conditioning The proposed gasifier system was to operate at 10 tpd capacity while the F-T plant was capable of approximately one barrel per day. Although the gasifier output would have been roughly ten times the F-T plant’s required input, the 10 tpd capacity was chosen to enable scaling to commercial capacity. Project partners included i) SGC Energia, owner of the F-T technology and owner of the proposed demonstration site in Pasadena, Texas; ii) Stanley Consultants, a reputable engineering company that provided detailed electrical engineering services; and iii) Delphi Engineering & Construction LLC, a consulting company that provided project management advisory services. The integrated plant was never constructed due to lack of cost share funds. However, the commercialization plan and associated financial model suggested such a plant could be economically viable when the price of oil exceeds $70 per barrel. The price of feedstock plays a significant role in the profitability of the plant for a given value of oil. An integrated biorefinery capable of producing liquid transportation fuels and other chemical feedstocks would benefit the public by providing a sustainable pathway to convert domestically available feedstocks into fuels that might otherwise be imported from countries or regions of the world that are typically hostile to the United States.

09 BIOMASS FUELS↗

Eastern Interconnection Wide-Area Oscillation Assessment and Study Report

To meet the government mandates such as Renewable Portfolio Standards (RPS), conventional synchronous generators with rotating mass are being displaced by inverter-based resources (IBRs), leading to high penetration of renewable energy sources (RES). As a result, the inherent properties and characteristics of the transformed generation mix may significantly impact the grid behaviour, and it is of paramount significance that the impact and the consequences of the resource mix change is thoroughly understood to adopt measures to maintain reliable grid operations. Of great concern is the inter-area low-frequency oscillation, which usually propagates through a large region and has a system-wide impact. Such oscillations may lead to unnecessary or inadvertent tripping of generators, that may be simply reacting to the oscillation originating from geographically remote sites. Such tripping of generators can lead to cascading outages, system split and load loss events. Over the years, several system-wide oscillation events have been observed across all three North American interconnections. This project titled Wide-area Oscillation Assessment and Trending Study, sponsored by the Office of Electricity (OE) of the Department of Energy (DOE), aims to conduct the required research to capture and investigate the potential changes in wide-area oscillatory performance of the system as a result of resource mix transition. The Pacific Northwest National Laboratory (PNNL) conducted this research and technical staff of Federal Energy Regulatory Commission (FERC) served as advisors to the project. The primary objective of this study is to assess whether there are significant trends in the power system wide-area oscillatory behaviours, as a result of the generation-mix changes due to the increased penetration of RES in the U.S. Eastern Interconnection (EI). The analysis presented in this report can serve as reference for future grid planning and operation of the EI system. This research conducted in this project evaluates the wide-area oscillatory behaviour of the EI, using a model-based approach for potential future resource mixes, and the measurement-based analysis with 21-month phasor measurement unit (PMU) time series. The oscillation modes in EI system along with the impact of the changes of the generation mix on the frequency and damping ratio (DR) of the oscillations have been studied.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SIW21-95: Hybridizing Synchronous Condensers with Grid-Forming Battery Energy Storage Systems

One of the main challenges associated with deployment of high shares of inverter-based resources (IBRs) in power grid is not only reduced system inertia but also degrading system strength that may cause severe stability impacts. A minimum level of system strength is needed for the power system to remain stable under normal conditions and to return to a steady state condition following a system disturbance. Significant system strength reduction is expected in almost all planned areas for solar and wind generation deployment. Synchronous condensers (SC) have been considered as one main technology to address the system strength issues for the areas with high levels of IBRs. SCs can help improving reliability and resiliency of power system but they do not provide the full range of services needed by power systems for reliable and economic integration of high shares of inverter-coupled variable generation such as PV generation. Services related to active power controls cannot be provided by SCs due to lack of prime mover. Even for provision of reactive power SCs have certain constraints based on their thermal and stability limits. NREL has been conducting research on a hybridized concept that combines SCs with grid forming (GFM) battery energy storage systems (BESS). This super flexible AC transmission system (SuperFACTS) that combines these two technologies in a single plant under the same controller offers a unique scalable set of services to the power system at all levels (transmission, sub-transmission, distribution, islands and isolated microgrids). Depending on use cases, SuperFACTS can be controlled to provide fully dispatchable and flexible operation using energy storage component, provide a full range of existing and future ancillary and reliability services to the grid (similar or better than conventional sources), maintain adequate levels of grid strength and inertia, and provide fault current for proper operation of protection systems. Therefore, this economic and easy to commercialize solution has potential for significant impacts on certain segments of global energy sector. All types of gird services (market based, reliability and resiliency) can be provided by SuperFACTS plants. GFM BESS can act as a self-black start source for each SuperFACTS module, which in turn can act a black start resource for co-located PV and wind power plants, segments of transmission and distribution networks, for conventional power plants, etc. The issue of in-rush currents during black start is addressed by overcurrent capability of SCs. In this paper we describe the results of modeling for SuperFACTS concept.

grid forming↗