Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Impact of refrigerant undercharge faults on building indoor conditions and HVAC system operation in residential Buildings: A simulation study

This study investigates the impact of refrigerant undercharge on indoor temperature and HVAC system performance in residential buildings. Simulation models for typical residential buildings in Orlando, FL and Indianapolis, IN were developed using the ResStock database. A refrigerant undercharge fault model was then applied to the simulations with varying levels of fault intensity. The paper offers an extensive analysis, revealing that variations in supply air temperature, equipment runtime, and cooling energy consumption due to the level of refrigerant undercharge faults are notably significant on a summer representative day. Similarly, on a winter representative day, changes in supply air temperature and runtime are significant as well as changes in supplemental heat energy consumption. We find that occupants may remain oblivious to these faults during the cooling season, particularly when the HVAC system is oversized; in that case, supply air temperature data could help detect a fault. Another challenge is that during the heating season, when the supplemental heater operates, it is difficult to identify a refrigerant undercharge fault using only indoor and supply air temperature data. Finally, this study finds that supply air temperature, equipment runtime, and supplemental heater energy consumption data can help in detecting refrigerant undercharge faults.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detailed Evaluation of Electric Demand Load Shifting Potential of Heat Pump Water Heaters

Future utilities will emphasize home appliances to reduce greenhouse gas emissions while providing electric load shifting and demand profile management. Heat pump water heaters (HPWH) have demonstrated the ability to cut water heating energy by more than 65% compared with conventional electric resistance waters (ERWH). Laboratory research was conducted on the load shifting potential of grid-connected heat pump water heaters (HPWH), compared to ERWHs. Testing applied different CTA-2045 command designs. Highly-controlled laboratory experiments were conducted on one ERWH and four HPWHs, including a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load up above the tank setpoint. The prototype unit with the B-protocol increased tank temperature by 15oF (8.3C) under the advanced load up providing an increase of 1.8 kWh of storage for a 50-gallon (189 liter) tank. The prototype includes a built-in mixing valve to meet anti-scalding codes. With the load-shaping ability of CTA-2045-B, utilities might be able to store excess renewable energy in connected tanks when renewable wind and solar resource production is high. Tests were performed under baseline conditions (no load shift) and under several load-shifting schemes, including load up and advanced load up, ahead of shed commands. Grid-connected HPWHs reduced peak demand by as much as 0.5 kW, depending on tank volume, time of day, control scheme, and draw profile.

heat pump water heater, Demand flexibility, load s↗

Mass and energy flow near sunspots

Sunspots block the flow of energy to the solar surface. The blocked energy heats the volume beneath the spot, producing a pressure excess which drives an outflow of mass. Linear numerical models of the mass and energy flow around spots were constructed to estimate the predictions of this physical picture against the observed properties of sunspot bright rings and moat flows. The width of the bright ring and moat are predicted to be proportional to the depth of the spot penumbra, in conflict with the observed proportionality of the moat width to the spot diameter. Postulating that spot depths are proportional to spot diameters would bury the moat flow too deeply to be observed, because the radial velocity at the surface is found to be inversely proportional to the depth of the spot penumbra. The radial velocity at the surface is of order a few hundred meters per second after 1 day, in agreement with the observed excess of moat velocities over supergranule velocities.

Nye, Alan↗

Thermodynamic Cycle Analysis of Magnetohydrodynamic-Bypass Hypersonic Airbreathing Engines

The prospects for realizing a magnetohydrodynamic (MHD) bypass hypersonic airbreathing engine are examined from the standpoint of fundamental thermodynamic feasibility. The MHD-bypass engine, first proposed as part of the Russian AJAX vehicle concept, is based on the idea of redistributing energy between various stages of the propulsion system flow train. The system uses an MHD generator to extract a portion of the aerodynamic heating energy from the inlet and an MHD accelerator to reintroduce this power as kinetic energy in the exhaust stream. In this way, the combustor entrance Mach number can be limited to a specified value even as the flight Mach number increases. Thus, the fuel and air can be efficiently mixed and burned within a practical combustor length, and the flight Mach number operating envelope can be extended. In this paper, we quantitatively assess the performance potential and scientific feasibility of MHD-bypass engines using a simplified thermodynamic analysis. This cycle analysis, based on a thermally and calorically perfect gas, incorporates a coupled MHD generator-accelerator system and accounts for aerodynamic losses and thermodynamic process efficiencies in the various engin components. It is found that the flight Mach number range can be significantly extended; however, overall performance is hampered by non-isentropic losses in the MHD devices.

Litchford, R. J.↗

Experiments on the Recovery of Waste Heat in Cooling Ducts, Special Report

Tests have been conducted in the N.A.C.A. full-scale wind tunnel to investigate the partial recovery of the heat energy which is apparently wasted in the cooling of aircraft engines. The results indicate that if the radiator is located in an expanded duct, a part of the energy lost in cooling is recovered; however, the energy recovery is not of practical importance up to airplane speeds of 400 miles per hour. Throttling of the duct flow occurs with heated radiators and must be considered in designing the duct outlets from data obtained with cold radiators in the ducts.

Silverstein, Abe↗

Thermoradiative Arrays: A New Technology for Conversion of Heat into Electrical Power

The thermoradiative cell is a recently developed solid-state device for generating electrical power from heat energy. Thermoradiative arrays could be used as the conversion technology for production of electrical power from thermal sources such as nuclear reactors or radioisotope heat sources in space. The technology has the potential for efficient conversion compared to existing technologies used for space, but as yet is in a low state of development, with considerable work to be done. A roadmap of key research needs is given.

heat into electrical power↗

Improved Heat-of-Fusion Energy Storage

Alkali metal/alkali-halide mixtures proposed for preventing solid buildup during energy recovery. When mixture melts (by absorption of heat of fusion), it forms two immiscible liquids. Salt-rich phase is heavier and has higher melting/recrysallization temperature; so during energy recovery salt crystallizes in this phase first. Since heat exchanger for energy recovery is in lighter metal-rich phase, solids do not form and there is no reduction of heat-recovery efficiency.

Chen, K. H.↗

Composite Aerogel Multifoil Protective Shielding

New technologies are needed to survive the temperatures, radiation, and hypervelocity particles that exploration spacecraft encounter. Multilayer insulations (MLIs) have been used on many spacecraft as thermal insulation. Other materials and composites have been used as micrometeorite shielding or radiation shielding. However, no material composite has been developed and employed as a combined thermal insulation, micrometeorite, and radiation shielding. By replacing the scrims that have been used to separate the foil layers in MLIs with various aerogels, and by using a variety of different metal foils, the overall protective performance of MLIs can be greatly expanded to act as thermal insulation, radiation shielding, and hypervelocity particle shielding. Aerogels are highly porous, low-density solids that are produced by the gelation of metal alkoxides and supercritical drying. Aerogels have been flown in NASA missions as a hypervelocity particle capture medium (Stardust) and as thermal insulation (2003 MER). Composite aerogel multifoil protective shielding would be used to provide thermal insulation, while also shielding spacecraft or components from radiation and hypervelocity particle impacts. Multiple layers of foil separated by aerogel would act as a thermal barrier by preventing the transport of heat energy through the composite. The silica aerogel would act as a convective and conductive thermal barrier, while the titania powder and metal foils would absorb and reflect the radiative heat. It would also capture small hypervelocity particles, such as micrometeorites, since it would be a stuffed, multi-shock Whipple shield. The metal foil layers would slow and break up the impacting particles, while the aerogel layers would convert the kinetic energy of the particles to thermal and mechanical energy and stop the particles.

Jones, Steven M.↗

Observation of a heated electron population associated with the 6300 A SAR arc emission

Conjunctive observations of the Dynamics Explorer satellite pair and the Pacific Northwest Laboratory scanning photometer unit at Richland, WA have allowed identification of the low energy, heated, electron population associated with the 6300 A Stable Auroral Red (SAR) arc emission. Measurements over the SAR arc on day 296 of 1981 show an enhanced flux in the low altitude 5-12 eV electrons. Analysis of this electron population shows them to be fairly Maxwellian, with temperatures on the order of 9900 + or - 1100 K and an earthward field aligned velocity of approximately 275 + or - 60 km/sec. The electrons are not accompanied by ion precipitation. The ion loss cone is empty at least as high as 6000 km. This fact may cast some doubt as to the role of the ring current ions in the SAR arc production.

Gurgiolo, C.↗

Heat Pumps and Energy Recovering Ventilators in Northern Alaska

The intended purpose of this project was to bring alternative heat and ventilation options to rural communities off the road system in Northwestern Alaska. Most of the residents of these communities are reliant upon kerosene or other fossil fuels to provide heat to their homes. Our intention was to offer an alternative to using those sources by providing heat pumps to 45 homes in the communities of Elim and Koyuk. When projecting energy use for these units based on the fuel prices at the time, it was discovered that energy costs for heat pumps would equal or slightly exceed the costs of existing kerosene units. Secondly, as part of our E&l grant we installed 45 energy recovery ventilators (ERV’s) in those same homes. This was important given our experience over the years with moisture and comfort issues in most homes within this region. Exhaust-only systems are rarely used due to the high heating costs. Additionally, exhaust-only systems have a potential risk of back drafting due to tight building construction. Balanced systems like this eliminate that risk while improving indoor air quality. Another benefit to these types of systems is the fact that they help transfer heat from a single heat source equally throughout the building. Our overall goal was to offer new technology options to improve these structures and the families that reside in them where, given their location and extreme seasonal temperature swings, they have historically never been offered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Free energy and specific heat near a quantum critical point of a metal

We analyze the free energy and the specific heat for fermions interacting with a gapless boson at a quantum-critical point (QCP) in a metal. We use the Luttinger-Ward-Eliashberg formula for the free energy in the normal state, which includes contributions from bosons, fermions, and their interaction, all expressed via fully dressed fermionic and bosonic propagators. The sum of the last two contributions is the free energy F γ of an effective low-energy model of fermions with boson-mediated dynamical 4-fermion interaction V(Ω m ) ∝ 1/|Ω m | γ (the γ model). This purely electronic model has been used to analyze the interplay between non-Fermi liquid behavior and pairing near a QCP, which are both independent of the upper energy cutoff Λ. However, the specific heat C γ (T), obtained from F γ , does depend on Λ. We argue that this dependence is spurious and cancels out, once we include the contribution from bosons. We further argue that the full C(T) is the sum of the contribution from free fermions and the one from a critical boson, with the fully dressed propagator, other terms cancel out. We compare the full C(T) with the C γ (T), obtained using recently proposed regularization of F γ . We argue that for γ < 1, the full C(T) and the regularized C γ (T) differ by a γ-dependent prefactor, while for γ > 1, the full C(T) and C γ (T) differ by the positive contribution from free massless fermions (a positive constant for the electron-phonon case γ = 2). For these γ, C γ (T) is negative, but the full C(T) is positive. We argue that only the full C(T) matters as the positive and the negative contributions originate from the term in C(T) which contains the fully dressed bosonic propagator. Here, we then argue that the normal state remains stable until the pairing instability develops.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Energy-Efficient, Continuous-Flow Ash Lockhopper

Pressure balance in control gas prevents loss of reactor gas. Energy efficiency of continuous-flow ash lockhopper increased by preventing hot gases from flowing out of reactor vessel through ash-hopper outlet and carrying away heat energy. Stopping loss of reactor gases also important for reasons other than energy efficiency; desired reaction product toxic or contained to prevent pollution. In improved continuous-flow ash lockhopper, pressure-driven loss of hot gas from reactor vessel through ash-hopper outlet prevented by using control gas in fluidic flow-control device to equalize pressure in reactor vessel. Also enables reactor to attain highest possible product yield with continuous processing while permitting controllable, continuous flow of ash.

Collins, Earl R., Jr.↗

Solar heating and cooling technical data and systems analysis

The acquisition and processing of selected parametric data for inclusion in a computerized Data Base using the Marshall Information Retrieval and Data System (MIRADS) developed by NASA-MSFC is discussed. This data base provides extensive technical and socioeconomic information related to solar energy heating and cooling on a national scale. A broadly based research approach was used to assist in the support of program management and the application of a cost-effective program for solar energy development and demonstration.

Christensen, D. L.↗

Thermoradiative Conversion for Space Power Systems

The thermoradiative cell is a new method for converting heat energy to electrical power, first detailed by Strandberg in 2015. The cell is structurally similar to a photovoltaic cell, in that it is a p-n junction semiconductor device, but thermodynamically operates in the reverse direction, converting the thermal dark current into electrical power by utilizing the recombination radiation from thermally-generated electron hole pairs to radiate waste heat to space. This technology may have application for space missions in converting thermal energy produced by a radioisotope source or from a nuclear reactor into power. The power and efficiency can be calculated as a function of bandgap in the detailed-balance case (the Shockley-Queisser limit), in which all of the thermal emissivity of the cell is due to the recombination of thermally generated electron-hole pairs, and all other recombination losses are ignored. The current produced is directly proportional to the recombination radiation, and thus the more thermally generated pairs, the higher the current. The voltage is proportional to the external bias. These two constraints allow optimization of the optimum bias point for maximum power, and allow calculation of the efficiency at maximum power point. Unlike photovoltaic cells, the maximum power operating point is not the same as the maximum efficiency point, and higher efficiency can be achieved at a higher (negative) bias in the ideal case. Incorporating non-ideal losses, however, shifts the maximum efficiency point toward lower bias. Since a thermoradiative cell operates by radiating directly to space, the current produced by a themoradiative cells will increase with the Stefan-Boltzman radiative efficiency; roughly the fourth power of the temperature. Thus, in contrast to a photovoltaic converter, the power produced is highest at high operating temperatures. Likewise, in contrast to conventional thermal conversion, high radiator temperature increases, rather than decreases the efficiency. Thus, the thermoradiative conversion may fill a mission niche in which small radiator size is required. The basic operation will be summarized, applications to space power discussed, and the requirements for further research outlined.

Photovoltaic Cell↗

Investigation of HVAC operation strategies for office buildings during COVID-19 pandemic

To minimize the indoor transmission of contaminants, such as the virus that can lead to COVID-19, buildings must provide the best indoor air quality possible. Improving indoor air quality can be achieved through the building's HVAC system to decrease any concentration of indoor contaminants by dilution and/or by source removal. However, doing so has practical downsides on the HVAC operation that are not always quantified in the literature. This paper develops a temporal simulation capability that is used to investigate the indoor virus concentration and operational cost of an HVAC system for two mitigation strategies: (1) supplying 100% outdoor air into the building and (2) using different HVAC filters, including MERV 10, MERV 13, and HEPA filters. These strategies are applied to a hypothetical medium office building consisting of five occupied zones and located in a cold and dry climate. We modeled the building using the Modelica Buildings library and developed new models for HVAC filtration and virus transmission to evaluate COVID-19 scenarios. We show that the ASHRAE-recommended MERV 13 filtration reduces the average virus concentration by about 10% when compared to MERV 10 filtration, with an increase in site energy consumption of about 3%. In contrast, the use of 100% outdoor air reduces the average indoor concentration by about an additional 1% compared to MERV 13 filtration, but significantly increases heating energy consumption. Use of HEPA filtration increases the average indoor concentration and energy consumption compared to MERV 13 filtration due to the high resistance of the HEPA filter.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FEED Study of Carbon Capture Inc. DAC and CarbonCure Utilization Using United States Steel's Gary Works Waste Plant

The University of Illinois Urbana-Champaign (UIUC) is spearheading a front-end engineering design (FEED) study of a Direct Air Capture and Utilization System (DACUS) that can remove 5,000 tonnes/yr net CO2 from ambient air, utilizing it in the production of concrete. The designed system, if built, would be larger than any currently existing DAC collector. Such carbon negative technologies are critical to meeting the goals of the DOE’s program to accelerate climate-critical technology. DAC is a promising new technology for reducing the greenhouse gas in the atmosphere but is expensive, partly due to the energy required to capture and then release CO2 during the process. By integrating CarbonCapture Technologies Inc. DAC collector at United States Steel's Gary Works and utilizing steel plant's waste heat, energy, and location so energy & transportation costs can be minimized. CarbonCapture has developed an innovative DAC system using novel adsorbents to cost- effectively capture CO2. The captured, liquified CO2 will be trucked to ready-mix concrete plants across Illinois, Indiana, & Wisconsin, where CarbonCure will inject it into concrete during the mixing process. The carbon dioxide reacts with concrete, mineralizing into calcium carbonate (CaCO3), sequestering the CO2 into the concrete, and reducing the amount of cement, the manufacturing of which is among the major sources of CO2 emissions. This FEED study demonstrates a full CO2 value chain for DACUS from industrial facilities. It also provided an opportunity to assess the impact of this holistic approach on job creation, regional economic impact, and environmental justice.

Carbon management, ccus, carbon capture, utilizati↗

The Use of Long-wave Infrared Cameras for Hazardous Waste Remediation - 20457

For over fifty years, infrared cameras have been used in military applications, nondestructive testing, condition monitoring, and predictive maintenance. As infrared cameras continue to become more sophisticated and less expensive, they are providing value in an ever-increasing variety of unique applications, including hazardous waste remediation. This paper describes several instances of how infrared cameras have been used within the US Department of Defense and the US Department of Energy in support of waste remediation projects, including the author's recent use of an infrared camera in support of the Calcine Retrieval Project at the Idaho National Laboratory. Infrared cameras provide images of infrared radiation, or heat energy, which is otherwise invisible to the unaided eye. Infrared radiation is part of the electromagnetic spectrum, which includes visible light. But unlike visible light, infrared has wavelengths longer than the human eye can detect. Infrared is emitted by everything with a temperature above absolute zero (-273 deg. C, or -459 deg. F); the higher the temperature, the greater the infrared thermal radiation, or heat, that is emitted. Even objects that feel cold to us, like ice, emit thermal radiation and can be imaged by infrared cameras. These cameras are typically used to look for abnormally hot or cold spots on a component or target area under normal operating conditions. The method provides a rapid, wide-area, noncontact technique for identifying problems associated with a temperature differential. All infrared cameras can provide qualitative thermal information by displaying relative differences in temperatures within a two-dimensional image. More expensive infrared cameras can also provide quantitative information where an absolute temperature value is assigned to each pixel associated with the displayed two-dimensional image. Proper camera calibration and a solid understanding of heat transfer and thermography techniques are required when using an infrared camera to obtain quantitative information. Case studies outlined in this paper include the rapid, non-intrusive detection of hazardous decontamination solution within one-ton shipping containers at Pine Bluff Arsenal, the non-intrusive identification of residual elemental sodium within the cooling loops of the Experimental Breeder Reactor II (EBR-II) reactor at the Idaho National Laboratory, process monitoring of heat exchanger melt-and-drain efforts during EBR-II decommissioning, and the remote detection of internal steel supports within calcine storage bins prior to bin penetration. For each use of thermography, the author describes a summary of the waste remediation effort, the infrared camera used, the thermal imaging technique employed, and the results obtained. The paper concludes with a discussion on common mistakes to avoid for similar applications of thermography. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗