Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Germanium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Empirical Correction of Crosstalk in a Low-Background Germanium γ–γ Analysis System

ABSTRACT The Pacific Northwest National Laboratory is currently developing a custom software suite capable of automating many of the tasks required to accurately analyze coincident signals within gamma spectrometer arrays. During the course of this work, significant crosstalk was identified in the energy determination for spectra collected with a new low-background intrinsic germanium (HPGe) array at PNNL. The HPGe array is designed for high detection efficiency, ultra-low-background performance, and sensitive gamma gamma coincidence detection. The first half of the array, a single cryostat containing 7 HPGe crystals, was recently installed into a new shallow underground laboratory facility. This update will present a brief review of the germanium array, describe the observed crosstalk, and present a straight-forward empirical correction that significantly reduces the impact of this crosstalk on the spectroscopic performance of the system.

coincidence↗

Germanium as negative electrode material for sodium-ion batteries

Germanium electrodes show a reversible Na-ion reaction at potentials of 0.15 and 0.6 V during discharge and charge, respectively. The reaction is accompanied with a reversible capacity close to 350 mAh g-1, which matches the value expected for the formation of NaGe. The electrode capacity retention is stable over 15 cycles but declines somewhat rapidly afterwards. This decline is typical for alloying systems undergoing large volume expansion, and calls for engineering solutions to confine the mechanical stress and control the electrolyte decomposition reactions that are likely to be the main sources of degradations. The rate performance results highlight the huge potential of nanosized germanium as a potential Na-ion anode. The reaction kinetics is found to be very good with about 220 mAh g-1 delivered at 170 C. Finally, the preliminary XRD results do not reveal the formation of crystalline phases at full (dis)charge.

Baggetto, Loic↗

Performance tests of large area position-sensitive planar germanium detectors with conventional and amorphous contacts.

Large area position-sensitive planar germanium wafers are increasingly being used for a variety of gamma-ray imaging and tracking tasks. Position sensitivity can be achieved through measuring charge collected on orthogonal strip electrodes, and by digital pulse shape analysis. However, the development of this detector technology has been slow, and criteria to measure improved performance have not been well established. We have studied 93 and 88 mm square segmented detectors of 20 mm thickness made with conventional boron and lithium electrodes, and two 100 mm circular segmented detectors of 14 mm thickness with amorphous germanium contacts. We have compared these detectors with a planar detector of 15 mm thickness. Conventional energy resolution tests of individual strips are insufficient to fully categorize the performance of the position sensitive detectors. We propose some basic tests which can rapidly quantify any segmented detector characteristics, and show potential inadequacies which become important when imaging or tracking is attempted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of high purity germanium point contact detectors with low net impurity concentration

High Purity germanium point-contact detectors have low energy thresholds and excellent energy resolution over a wide energy range, and are thus widely used in nuclear and particle physics. In rare event searches, such as neutrinoless double beta decay, the point-contact geometry is of particular importance since it allows for pulse-shape discrimination, and therefore for a significant background reduction. In this paper we investigate the pulse-shape discrimination performance of ultra-high purity germanium point contact detectors. It is demonstrated that a minimal net impurity concentration is required to meet the pulse-shape performance requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GADGET: a Gaseous Detector with Germanium Tagging

The Gaseous Detector with Germanium Tagging (GADGET) is a new detection system devoted to the measurement of weak, low-energy β-delayed proton decays relevant for nuclear astrophysics studies. It is comprised of a new gaseous Proton Detector equipped with a Micromegas readout for charged particle detection, surrounded by the existing Segmented Germanium Array (SeGA) for the high-resolution detection of the prompt γ-rays. Here in this work we describe in detail for the first time the design, construction, and operation of the GADGET system, including performance of the Proton Detector. We present the results of a recent commissioning experiment performed with 25 Si beam at the National Superconducting Cyclotron Laboratory (NSCL). GADGET provided low-background, low-energy β-delayed proton detection with efficiency above 95%, and relatively good efficiency for proton-gamma coincidences (2.7% at 1.37 MeV).

β-delayed proton emission↗

Correlation Between Optical Properties And Chemical Composition Of Sputter-deposited Germanium Cxide (GeO x ) Films

Germanium oxide (GeO x ) films were grown on (1 0 0) Si substrates by reactive Direct-Current (DC) magnetron sputter-deposition using an elemental Ge target. The effects of oxygen gas fraction, Г = O 2 /(Ar + O 2 ), on the deposition rate, structure, chemical composition and optical properties of GeOx films have been investigated. The chemistry of the films exhibits an evolution from pure Ge to mixed Ge + GeO + GeO 2 and then finally to GeO 2 upon increasing Г from 0.00 to 1.00. Grazing incidence X-ray analysis indicates that the GeO x films grown were amorphous. The optical properties probed by spectroscopic ellipsometry indicate that the effect of Г is significant on the optical constants of the GeO x films. The measured index of refraction (n) at a wavelength (λ) of 550 nm is 4.67 for films grown without any oxygen, indicating behavior characteristic of semiconducting Ge. The transition from germanium to mixed Ge + GeO + GeO 2 composition is associated with a characteristic decrease in n (λ = 550 nm) to 2.62 and occurs at Г = 0.25. Finally n drops to 1.60 for Г = 0.50–1.00, where the films become GeO 2 . A detailed correlation between Г, n, k and stoichiometry in DC sputtered GeO x films is presented and discussed.

36 MATERIALS SCIENCE↗

Nuclear charge radii of germanium isotopes around N = 40

Collinear laser spectroscopy measurements were performed on 68−74 Ge isotopes (Z=32) at ISOLDE-CERN, by probing the 4s 2 4p 2 3 P 1 → 4s 2 4p5s 3 P$^{o}_{1}$ atomic transition (269~nm) of germanium. Nuclear charge radii are determined via the measured isotope shifts, revealing a larger local variation than the neighboring isotopic chains. Nuclear density functional theory with the Fayans functionals Fy(Δr,HFB) and Fy(IVP), and the SV-min Skyrme describes the experimental data for the differential charge radii δ⟨r 2 ⟩ and charge radii R c within the theoretical uncertainties. The observed large variation in the charge radii of germanium isotopes is better accounted for by theoretical models incorporating ground state quadrupole correlations. This suggests that the polarization effects due to pairing and deformation contribute to the observed large odd-even staggering in the charge radii of the Ge isotopic chain.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct and simultaneous observation of ultrafast electron and hole dynamics in germanium

Understanding excited carrier dynamics in semiconductors is crucial for the development of photovoltaics and efficient photonic devices. However, overlapping spectral features in optical pump-probe spectroscopy often render assignments of separate electron and hole carrier dynamics ambiguous. Here, ultrafast electron and hole dynamics in germanium nanocrystalline thin films are directly and simultaneously observed by ultrafast transient absorption spectroscopy in the extreme ultraviolet at the germanium M 4,5 edge. We decompose the spectra into contributions of electronic state blocking and photo-induced band shifts at a carrier density of 8 × 10 20 cm –3 . Separate electron and hole relaxation times are observed as a function of hot carrier energies. A first-order electron and hole decay of ~1 ps suggests a Shockley–Read–Hall recombination mechanism. Furthermore, the simultaneous observation of electrons and holes with extreme ultraviolet transient absorption spectroscopy paves the way for investigating few- to sub-femtosecond dynamics of both holes and electrons in complex semiconductor materials and across junctions.

36 MATERIALS SCIENCE↗

A digital method for separation and reconstruction of pile-up events in germanium detectors

The problem of pulse pile-up is very often encountered in precise measurements of {gamma}-rays using germanium detectors. The standard method of treating the pile-up events is to identify and reject them using an appropriate electronic system. Digital acquisition techniques now allow the recording of waveforms of pile-up events that can be analyzed and the contributing single pulses recovered, rather than simply tolerating the losses associated with pile-up. In this paper, a method for the off-line digital processing of pile-up events from germanium detectors is demonstrated. The method is based on an appropriate fitting of the detector signals, shaped with a suitable digital pulse shaper. It is shown that the method is able to recover the pile-up events with good accuracy even when the constituent signals are in close proximity. The method is very useful for {gamma}-ray spectroscopy in nuclear physics experiments, where the low intensity signals can be lost due to the pile-up in a high-rate environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploration Of Activity Measurements And Equilibrium Checks For Sediment Dating Using Thick-Window Germanium Detectors

Activity measurements on sediment samples for trapped-charge geological dating using gamma-ray spectroscopy are an important verification of the field-site dose rate determination. Furthermore gamma-ray spectroscopy can check if the natural decay series are in secular equilibrium which is a crucial assumption in such dating. Typically the activities of leading members of the Thorium and Uranium decay series are measured, which requires Germanium detectors with thin windows and good energy resolution in order to effectively detect the associated low energy gamma-rays. Such equipment is not always readily available. The potential of conventional Germanium detectors with thick entrance window has been explored towards routine gamma-ray spectroscopy of sediment samples using higher energy gamma-rays. Alternative isotopes, such as Ac-228 and Pb-212 for the Thorium series, and Pa-234m, Ra-226 and Bi-214 for the Uranium series, have been measured in order to determine the mass-specific activity for the respective series and possibly provide a check of secular equilibrium. In addition to measurements of the K-40 activity, with the alternative approach, the activities of both decay series can be accurately determined. The secular equilibrium condition may be tested for the Thorium series. Measurement accuracy for Pa-234m is, however, not sufficient to permit also a reliable check of equilibrium for the Uranium series.

07 ISOTOPE AND RADIATION SOURCES↗

HEROICA: A fast screening facility for the characterization of germanium detectors

In the course of 2012, a facility for the fast screening of germanium detectors called HEROICA (Hades Experimental Research Of Intrinsic Crystal Appliances) has been installed at the HADES underground laboratory in the premises of the Belgian Nuclear Research Centre SCK•CEN, in Mol (Belgium). The facility allows performing a complete characterization of the critical germanium detectors' operational parameters with a rate of about two detectors per week.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Driving chemical interactions at graphene-germanium van der Waals interfaces via thermal annealing

Despite its extraordinary charge carrier mobility, the lack of an electronic bandgap in graphene limits its utilization in electronic devices. To overcome this issue, researchers have attempted to chemically modify the pristine graphene lattice in order to engineer its electronic bandstructure. While significant progress has been achieved, aggressive chemistries are often employed that are difficult to pattern and control. In an effort to overcome this issue, here we utilize the well-defined van der Waals interface between crystalline Ge(110) and epitaxial graphene to template covalent chemistry. In particular, by annealing atomically pristine graphene-germanium interfaces synthesized by chemical vapor deposition under ultra-high vacuum conditions, chemical bonding is driven between the germanium surface and the graphene lattice. The resulting bonds act as charge scattering centers that are identified with scanning tunneling microscopy. The generation of atomic-scale defects are independently confirmed with Raman spectroscopy, revealing significant densities within the graphene lattice. Furthermore, the resulting chemically modified graphene has the potential to impact next-generation nanoelectronic applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Formation of distinctive nanostructured metastable polymorphs mediated by kinetic transition pathways in germanium

High-pressure β -Sn germanium may transform into diverse metastable allotropes with distinctive nanostructures and unique physical properties via multiple pathways under decompression. However, the mechanism and transition kinetics remain poorly understood. Here, we investigate the formation of metastable phases and nanostructures in germanium via controllable transition pathways of β -Sn Ge under rapid decompression at different rates. High-resolution transmission electron microscopy reveals three distinct metastable phases with the distinctive nanostructures: an almost perfect st12 Ge crystal, nanosized bc8/r8 structures with amorphous boundaries, and amorphous Ge with nanosized clusters (0.8–2.5 nm). Fast in situ x-ray diffraction and x-ray absorption measurements indicate that these nanostructured products form in certain pressure regions via distinct kinetic pathways and are strongly correlated with nucleation rates and electronic transitions mediated by compression rate, temperature, and stress. This work provides deep insight into the controllable synthesis of metastable materials with unique crystal symmetries and nanostructures for potential applications.

36 MATERIALS SCIENCE↗

Femtosecond tracking of carrier relaxation in germanium with extreme ultraviolet transient reflectivity

Extreme ultraviolet (XUV) transient reflectivity around the germanium M 4,5 edge (3d core-level to valence transition) at 30 eV is advanced to obtain the transient dielectric function of crystalline germanium [100] on femtosecond to picosecond time scales following photoexcitation by broadband visible-to-infrared (VIS/NIR) pulses. By fitting the transient dielectric function, carrier-phonon induced relaxations are extracted for the excited carrier distribution. The measurements reveal a hot electron relaxation rate of 3.2±0.2ps attributed to the X-L intervalley scattering and a hot hole relaxation rate of 600±300fs ascribed to intravalley scattering within the heavy hole (HH) band, both in good agreement with previous work. An overall energy shift of the XUV dielectric function is assigned to a thermally induced band gap shrinkage by formation of acoustic phonons, which is observed to be on a timescale of 4-5 ps, in agreement with previously measured optical phonon lifetimes. The results reveal that the transient reflectivity signal at an angle of 66° with respect to the surface normal is dominated by changes to the real part of the dielectric function, due to the near critical angle of incidence of the experiment (66°-70° for the range of XUV energies used. Finally, this work provides a methodology for interpreting XUV transient reflectivity near core-level transitions, and it demonstrates the power of the XUV spectral region for measuring ultrafast excitation dynamics in solids.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ionization yield measurement in a germanium CDMSlite detector using photo-neutron sources

Two photo-neutron sources, Y 88 Be 9 and Sb 124 Be 9 , have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. In this study, we evaluate the yield for nuclear recoil energies between 1 and 7 keV at a temperature of ~ 50 mK . We use a geant4 simulation to model the neutron spectrum assuming a charge yield model that is a generalization of the standard Lindhard model and consists of two energy dependent parameters. We perform a likelihood analysis using the simulated neutron spectrum, modeled background, and experimental data to obtain the best fit values of the yield model. The ionization yield between recoil energies of 1 and 7 keV is shown to be significantly lower than predicted by the standard Lindhard model for germanium. There is a general lack of agreement among different experiments using a variety of techniques studying the low energy range of the nuclear recoil yield, which is most critical for interpretation of direct dark matter searches. This suggests complexity in the physical process that many direct detection experiments use to model their primary signal detection mechanism and highlights the need for further studies to clarify underlying systematic effects that have not been well understood up to this point.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the low-energy quenching factor in germanium using an Y 88 / Be photoneutron source

Here, we employ an 88 Y/Be photoneutron source to derive the quenching factor for neutron-induced nuclear recoils in germanium, probing recoil energies from a few hundred eV nr to 8.5 keV nr . A comprehensive Monte Carlo simulation of our setup is compared to experimental data employing a Lindhard model with a free electronic energy loss k and an adiabatic correction for sub-keV nr nuclear recoils. The best fit k = 0.179 ± 0.001 obtained using a Monte Carlo Markov chain (MCMC) ensemble sampler is in good agreement with previous measurements, confirming the adequacy of the Lindhard model to describe the stopping of few-keV ions in germanium crystals at a temperature of ~77 K. This value of k corresponds to a quenching factor of 13.7% to 25.3% for nuclear recoil energies between 0.3 and 8.5 keV nr , respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evidence of Coherent Elastic Neutrino-Nucleus Scattering with COHERENT’s Germanium Array

We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on natural germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low-noise, high-purity germanium spectrometers, enabling excellent energy resolution, and an analysis threshold of 1.5 keV electron-equivalent ionization energy. We observe an on-beam excess of 20.6$^{+7.1}_{−6.3}$ counts with a total exposure of 10.22 GWhkg, and we reject the no-CEvNS hypothesis with 3.9⁢𝜎 significance. The result agrees with the predicted standard model of particle physics signal rate within 2⁢𝜎.

Electroweak interaction↗

A High-Efficiency Fieldable Germanium Detector Array

Historically, large germanium arrays for field applications have consisted of multiple detectors each housed in their own cryostat. In order to ruggedize the detectors for field use these cryostats have had additional support material introduced that significantly impacted cryogenic performance. This paper presents the development of a new cryostat design suitable for deployment of ~10 kg of high purity germanium detectors that achieves outstanding cryogenic performance (~5 W at 80 K) while providing the high detection efficiency required for stand-off measurements and the ruggedization required for use in a variety of field applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗