Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gamma ray spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Simulations of Terrestrial in-situ Cosmogenic-Nuclide Production

Targets of silicon and silicon dioxide were irradiated with spallation neutrons to simulate the production of long-lived radionuclides in the surface of the Earth. Gamma-ray spectroscopy was used to measure Be-7 and Na-22, and accelerator mass spectrometry was used to measure Be-10, C-14, and Al-26. The measured ratios of these nuclides are compared with calculated ratios and with ratios from other simulations and agree well with ratios inferred from terrestrial samples.

Reedy, R. C.↗

MASTER: An Orbiter for the Detailed Study of Vesta

MASTER (Mainbelt Asteroid Exploration/Rendezvous), a Discovery-class orbiter, will carry out a global geological and geochemical survey of Vesta. Primary goals include determining Vesta's mean density and interior structure through detailed mapping of the gravity field, imaging surface morphology at 3-m resolution, mapping mineralogy between 0.4 and 2.5 microns, and determining abundances of key elements through X-ray and gamma-ray spectroscopy. Spectroscopic evidence indicates the presence of basaltic lava flows on Vesta and suggests that impact basins may have exposed mantle materials. These possibilities, combined with the likelihood that Vesta is the ultimate source of HED meteorites, makes this asteroid an important target for a comprehensive orbiter mission. MASTER's global survey, combined with ongoing studies of HED meteorites, will be a major step in understanding the chemical, thermal, and geological evolution of Vesta. A particularly attractive opportunity involves a launch in June 2003 with arrival at Vesta in November 2009. The orbital phase of the mission is scheduled to last one year. A flyby of another mainbelt asteroid enroute to Vesta may be possible.

Veverka, J.↗

CGRO Observations

This final report presents an investigation of the CGRO (Compton Gamma Ray Observatory) observations. The investigation includes: Diffuse Gamma-Ray Emission at High Latitudes; and Echoes in X-Ray Novae; A Localized Excess of Gamma-Radiation; Transient Hard X-Ray Emission from Globular Clusters; and A Search for Be/X-Ray Binaries in Hard X-Rays; Hard X-Ray Emission from X-Ray Bursters; X-Ray Transients in Star-Forming Regions; Gamma-ray Emission from Globular Clusters; Shock High Energy Emission from Be-Star/Pulsar System PSR 1259-63m; Gamma-Ray Spectroscopy of Nearby OB Associations; Long Term Hard X-Ray Monitoring of X-Ray Busters; and Periodic Hard X-Ray Emission from GRO J1849-03.

Kaaret, Philip↗

Scientific Objectives of the Mars Surveyor 2001 Gamma-Ray Spectrometer

The Gamma-Ray Spectrometer (GRS) is one of the instruments on the Mars Surveyor 2001 Orbiter, which is part of NASA's Mars-Surveyor program. The GRS is really an instrument suite consisting of the GRS, a neutron spectrometer (NS), and a high-energy neutron detector (FIEND). Each of these instruments/sensors are remotely mounted at different locations on the spacecraft and connect to a central electronics box. The GRS will achieve global mapping of the elemental composition of the surface and the abundance of hydrogen in the shallow subsurface. It is an updated design using the same technology as the lost Mars Observer mission. The Martian surface is continuously bombarded by cosmic ray particles; their interactions with the constituents of the soil produces nuclear reaction cascades with fast neutrons being the main secondaries. Those neutrons interact in turn with the nuclei of the elements that make up the soil and they eventually get slowed to thermal energies. In this process they leave the nuclei in an excited state that decays via the emission of characteristic gamma rays. All these processes are precisely known and have been simulated by means of numerical models. Thus, remote gamma-ray spectroscopy is a useful method for quantitatively measuring the geochemical composition of the surface down to a few tens of g/sq cm. Additional information is contained in original extended abstract.

Boynton, W. V.↗

Crustal Heat Production and the Thermal Evolution of Mars

The chemical compositions of soils and rocks from the Pathfinder site and Phobos-2 orbital gamma-ray spectroscopy indicate that the Martian crust has a bulk composition equivalent to large-ion lithophile (LIL) and heat-producing element (HPE) enriched basalt, with a potassium content of about 0.5%. A variety of radiogenic isotopic data also suggest that separation of LIL-enriched crustal and depleted mantle reservoirs took place very early in Martian history (greater than 4.0 Ga). Accordingly, if the enriched Martian crust is greater than 30km thick it is likely that a large fraction (up to at least 50%) of the heat-producing elements in Mars was transferred into the crust very early in the planet's history. This would greatly diminish the possibility of early widespread melting of the Martian mantle.

McLennan, Scott M.↗

Crustal Heat Production and the Thermal Evolution of Mars

The chemical composition of soils and rocks from the Pathfinder site and Phobos-2 orbital gamma-ray spectroscopy indicate that the Martian crust has a bulk composition equivalent to large-ion lithophile (LIL) and heat-producing element (K, Th, U) enriched basalt, with a potassium content of about 0.5%. A variety of radiogenic isotope data also suggest that separation of LIL-enriched crust and depleted mantle reservoirs took place very early in Martian history (>4.0 Ga). Accordingly, if the enriched Martian crust is >30 km thick it is likely that a large fraction (up to at least 50%) of the heat-producing elements in Mars was transferred into the crust very early in the planet's history. This would greatly diminish the possibility of early widespread melting of the Martian mantle.

McLennan, Scott M.↗

Gamma Ray Burst Discoveries with the Swift Mission

There is a great synergy between the Swift and INTEGRAL missions. Swift provides wide-field hard x-ray monitoring and sensitive x-ray and UV/optical observations. INTEGRAL provides optical through gamma-ray coverage with emphasis on hard xray imaging and gamma-ray spectroscopy. For hard x-ray survey studies, the BAT and IBIS instruments are complementary with BAT covering the full sky every day and IBIS scanning the galactic plane. For GRBs, Swift follows up bursts detected by INTEGRAL. X-ray and optical observations give arcsecond positions and afterglow lightcurves. For IGR sources, X-ray observations identify counterparts. The joint BAT and IBIS survey data are giving the most complete picture of the hard x-ray sky ever obtained. This talk will review Swift capabilities and discuss joint observations that are taking place and planned

Gehrels, Neil↗

Silicon Photo-Multiplier Readouts for Scintillators in High-Energy Astronomy

New scintillator materials have recently been shown to hold great potential for low-cost, reliable gamma-ray detectors in high-energy astronomy. New devices for the detection of scintillation light promise to make scintillator-based instruments even more attractive by reducing mass and power requirements,in particular, silicon photo-multipliers (SiPMs) are starting to become commercially available that offer gains and quantum efficiencies similar to those of photo-multiplier tubes (PMTs), but with greatly reduced mass, high ruggedness, low voltage requirements, and no sensitivity to magnetic fields. We have conducted laboratory tests of a sample of commercially available SiPMs coupled to LaBr3;Ce, a scintillator of relevance to to future high-energy astrophysics missions. We present results for gamma-ray spectroscopy. compare the SiPM performance to that of a PMT, and discuss the extent to which SiPMs offer significant advantages for scintillator-based space missions.

Bloser, Peter F.↗

Cumulative short-lived photofission product yields for nuclear forensic application

Experiments have long been carried out with linear accelerator (linac) produced bremsstrahlung X-rays to study high-energy photon-induced fission, known as “photofission”. One benefit of photofission, when compared with neutron-induced fission, is the ability to investigate fundamental physics of fission at excitation energies lower than what is possible with neutrons [1]. Absorption of an incident neutron results in a compound nucleus with an excitation energy at least equal to the neutron binding energy; thus, the lowest energy region of the fission barrier cannot be studied. Fission product yield distributions are dependent on the incident particle energy and the target nucleus mass. They are generally represented by a double-humped curve, with low and high mass “peaks” and an intermediate mass “valley”. As incident particle energy increases, the excitation energy of the nucleus increases, thereby increasing the overall yield of isotopes in the valley with respect to the two maxima or peaks of the fission product curve [3]. Photofission is most probable for incident photons around 14 MeV due to the giant dipole resonance. Induced photofission around this energy results in a fission product yield distribution that resembles 14 MeV DT neutron fission more than thermal or fast (500 keV) neutron fission. In post-detonation nuclear forensics, the peak-to-valley ratio of the fission product yield curve could be used for characterizing device type by providing an indication of the neutron energy spectrum that had induced fission (e.g., 500 keV vs. 14 MeV). The goal of this work is to improve nuclear data for isotopes of interest in nuclear forensics and special nuclear material (SNM) detection, specifically the fission product yield data via photofission experiments for the isotopes of 238U and 232Th. Photofission has been proposed as a less costly and more flexible production method for the valley isotopes that are representative of DT neutron fission product yield distributions, which would benefit nuclear forensics exercises in testing for analysis techniques. Natural uranium and thorium targets were irradiated with bremsstrahlung photons (nominal endpoint energies of 8, 14, and 20 MeV), generated via impingement of high-energy electrons on a tungsten electron-to-photon radiator. Gamma-ray spectroscopy was used to observe and identify the decay of the resulting fission products. The photofission yields of 102 fission products were measured for the set of the 238U and 232Th targets at the three bremsstrahlung X-ray endpoint energies 8, 14, and 20 MeV. These fragments included masses ranging from A=84 to A=144, with half-lives as short as 1.07 seconds.

07 ISOTOPE AND RADIATION SOURCES↗

Correlated Signal Analysis for Nuclear Emergency Response

In the context of nuclear emergency response (NER) scenarios, the critical task is to quickly identify a "black box" as a potential threat, as failing to do so could have catastrophic consequences. Techniques for passive assay of a “black box” typically include gamma-ray spectroscopy and neutron coincidence/multiplicity counting. However, there are significant challenges associated with these type of measurements. First, the presence of intervening materials can obstruct the detection of relevant signatures. Second, the presence of strong non-fission neutron sources, like (α, n) emitters, can add uncertainties to the neutron multiplicity analysis. In our LDRD-MFR Phase II work, a portable neutron spectrometer, called the Compact Fast Neutron Spectrometer (CFNS), was developed for NER applications. The CFNS system leverages information-rich neutron energy spectra to derive actionable information. This work investigates the use of correlated signals in the CFNS from special nuclear material (SNM) to characterize physical properties, such as intervening shielding material and fission to non-fission neutron contributions. In this report, the Phase II results from bulk SNM measurements at the National Criticality Experiments Research Center (NCERC) are briefly discussed along with the motivation for this work. Afterwards, simulations using the MCNPX-PoliMi transport code are discussed, which were used to expand our correlated signal study. Signal triggered analysis for neutron multiplicity extraction will also be discussed. Lastly, the use neutron-photon correlations for intervening material identification are shown, along with the use of correlated neutron energy spectra for α-ratio extraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Internal-Gelation Production of Uranium Oxide Sol-Gel Particles for Forensic Applications

The purpose of this project was to develop and demonstrate a novel method for the production of uranium oxide microsphere particles with tunable chemical compositions via a sol-gel process using a 3D-printer setup. These particles can serve several purposes in research and development as a forensic training tool or as standard reference materials. A key component of the project was to demonstrate the ability to control physical and chemical parameters of the particles created. First, we demonstrated the ability to employ an internal gelation sol-gel process to create individual uranium oxide particles. The particles were successfully dispensed using a unique 3D-printing setup onto a substrate to react and then were collected and thermally processed. A series of temperatures for the annealing process was tested on individual samples to investigate the effect on the sol-gel chemical composition and physical integrity. Next, we demonstrated the ability to control matrix composition of the particles by separately incorporating fission product isotopes as well as Np-237 into the sol-gel solution. It was shown by gamma-ray spectroscopy that these matrix elements were successfully retained during the gelation process. We studied the retention of the elements across a series of annealing temperatures. Additionally, we demonstrated the ability to quantitatively control the isotopic composition of the particles by altering the U-237/U-238 ratio to a controlled value. Finally, X-ray diffraction analysis (XRD) was used to investigate the oxidation state of the sol-gel after annealing at different temperatures.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

3x3 array module of 8×8×32 mm 3 position-sensitive virtual frisch-grid CdZnTe detectors for imaging and spectroscopy of cosmic gamma-rays

Here, we evaluated the performance of the 3x3 array of 32-mm long position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors read out by the IDEAS GDS-100 data acquisition system. The array is a mechanically solid module designed for integration into a large effective area gamma-ray telescope proposed for imaging and spectroscopy of cosmic gamma-rays. The array employs the bar-shaped 8x8x32 mm 3 CZT crystals which recently became available from Redlen Technologies, Inc. and Kromek-eV Group PLC at affordable costs. The waveform sampling IDE3421 application-specific integrated circuit (ASIC), developed by the University of Michigan and IDEAS for CZT pixel detectors, was adapted to capture the signals from the array's VFG detectors. We showed good spectral performance of the Redlen detectors with an energy resolution of <1% FWHM at 662 keV and slightly poorer performance of the Kromek-eV detectors with a resolution of <2% measured at a reduced temperature of 13 °C. By testing the same detectors as single devices using hybrid charge-sensitive preamplifiers, we demonstrated improved energy resolutions at a normal temperature of ~25°C: <1% and 1.3-1.7%, respectively. However, the Kromek-eV detectors did not perform as well as the Redlen ones. We explained this by the space charge formation (polarization) decreasing the electric field and the electron drift times. The polarization was likely caused by the high injections of holes from the anode contacts. The absence of polarization in Redlen detectors suggested that the quality of the contacts might have played a role in this case.

47 OTHER INSTRUMENTATION↗

Gamma-ray burst and spectroscopy instrumentation development at the Goddard Space Flight Center

This paper summarizes the activities that are specifically related to the development of instrumentation for gamma-ray astronomy. Three programs are described: (1) the Gamma-Ray Imaging Spectrometer (GRIS), a balloon-borne array of seven germanium detectors for high-resolution spectrographic studies of persistent gamma-ray sources; (2) the Transient Gamma-Ray Spectrometer (TGRS), a single radiatively-cooled germanium detector for the spectrographic study of gamma-ray bursts, and (3) the Rapidly Moving Telescope (RMT), a ground-based optical telescope for the detection and study of short-lived optical transients, particularly those that occur in coincidence with gamma-ray bursts.

Teegarden, B. J.↗

X-ray remote sensing and in-situ spectroscopy for planetary exploration missions and gamma-ray remote sensing and in-situ spectroscopy for planetary exploration missions

Detectors that will be used for planetary missions must have their responses calibrated in a reproducible manner. A calibration facility is being constructed at Schlumberger-Doll Research for gamma and x ray detectors. With this facility the detector response can be determined in an invariant and reproducible fashion. Initial use of the facility is expected for the MARS94 detectors. Work is continuing to better understand the rare earth oxyorthosilicates and to define their characteristics. This will allow a better use of these scintillators for planetary missions. In a survey of scintillating materials two scintillators were identified as promising candidates besides GSO, LSO, and YSO. These are CdWO4 and CsI(Tl). It will be investigated if a detector with a better overall performance can be assembled with various photon converters. Considerable progress was achieved in photomultiplier design. The length of an 1 inch diameter PMT could be reduced from 4.2 to 2.5 inches without performance degradation. This technology is being employed in the gamma ray detector for the NEAR project. A further weight and size reduction of the detector package can be achieved with miniaturized integrated power supplies.

Mahdavi, M.↗

National Diagnostic Working Group (NDWG) for inertial confinement fusion (ICF)/high-energy density (HED) science: The whole exceeds the sum of its parts

The National Diagnostic Working Group (NDWG) has led the effort to fully exploit the major inertial confinement fusion/high-energy density facilities in the US with the best available diagnostics. These diagnostics provide key data used to falsify early theories for ignition and suggest new theories, recently leading to an experiment that exceeds the Lawson condition required for ignition. The factors contributing to the success of the NDWG, collaboration and scope evolution, and the methods of accomplishment of the NDWG are discussed in this Review. Examples of collaborations in neutron and gamma spectroscopy, x-ray and neutron imaging, x-ray spectroscopy, and deep-ultraviolet Thomson scattering are given. Here, an abbreviated history of the multi-decade collaborations and the present semiformal management framework is given together with the latest National Diagnostic Plan.

47 OTHER INSTRUMENTATION↗

Exploring Gamma-Ray and Neutron Spectroscopy Missions to Mars Caves [Slides]

In this work, we investigate the sensitivity of active neutron detector systems in Mars caves using MCNP6 to model neutron transport in different cave geometries, compositions, and detectors to determine if active neutron measurements can be used to identify the hydration of cave walls vs floor vs ceilings, and to perform a concept study for potential future Mars cave missions in search of hydration and habitable regions.

79 ASTRONOMY AND ASTROPHYSICS↗

The Spectral Properties of Gamma-ray Bursts: a Review of Recent Development

Developments in the spectroscopy of gamma ray bursts (GRB) are reviewed. The general question of the validity of the spectral results, particularly with regard to features in the spectrum, is discussed. Confirmations of these spectral features are summarized. Results from the KONUS experiments on Venera 13 and 14 are reviewed. The status of models of the continuum spectrum is summarized. A number of different radiation mechanisms appear capable of fitting the data. These include thermal bremsstrahlung, thermal synchrotron and inverse Compton. Rapid variability of the spectra shape on time scales 76] 0.25 sec. was reported. The characteristic energy of the spectrum was observed to vary over nearly an order of magnitude during individual events. A strong correlation between spectral hardness and luminosity was found. Low-energy (50 keV) absorption features and high-energy (400 keV) emission features continue to appear in GRB spectra. Understanding the origin of these lines in the context of the existing continuum models remains a difficult problem.

Teegarden, B. J.↗