Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GaGe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Low temperature coefficient of resistance and high gage factor in beryllium-doped silicon

The gage factor and resistivity of p-type silicon doped with beryllium was studied as a function of temperature, crystal orientation, and beryllium doping concentration. It was shown that the temperature coefficient of resistance can be varied and reduced to zero near room temperature by varying the beryllium doping level. Similarly, the magnitude of the piezoresistance gage factor for beryllium-doped silicon is slightly larger than for silicon doped with a shallow acceptor impurity such as boron, whereas the temperature coefficient of piezoresistance is about the same for material containing these two dopants. These results are discussed in terms of a model for the piezoresistance of compensated p-type silicon.

Robertson, J. B.↗

Flight loads measurements obtained from calibrated strain-gage bridges mounted externally on the skin of a low-aspect-ratio wing

Flight-test measurements of wingloads (shear, bending moment, and torque) were obtained by means of strain-gage bridges mounted on the exterior surface of a low-aspect-ratio, thin, swept wing which had a structural skin, full-depth honeycomb core, sandwich construction. Details concerning the strain-gage bridges, the calibration procedures used, and the flight-test results are presented along with some pressure measurements and theoretical calculations for comparison purposes.

Eckstrom, C. V.↗

Reliability analysis of forty-five strain-gage systems mounted on the first fan stage of a YF-100 engine

The reliability of 45 state-of-the-art strain gage systems under full scale engine testing was investigated. The flame spray process was used to install 23 systems on the first fan rotor of a YF-100 engine; the others were epoxy cemented. A total of 56 percent of the systems failed in 11 hours of engine operation. Flame spray system failures were primarily due to high gage resistance, probably caused by high stress levels. Epoxy system failures were principally erosion failures, but only on the concave side of the blade. Lead-wire failures between the blade-to-disk jump and the control room could not be analyzed.

Holanda, R.↗

Gage for 3-d contours

Simple gage, used with template, can help inspectors determine whether three-dimensional curved surface has correct contour. Gage was developed as aid in explosive forming of Space Shuttle emergency-escape hatch. For even greater accuracy, wedge can be made of metal and calibrated by indexing machine.

Haynie, C. C.↗

Elevated-temperature effects on strain gages on the YF-12A wing

A general study is made of the effects of structural heating on calibrated-strain-gage load measurements on the wing of a supersonic airplane. The primary emphasis is on temperature-induced effects as they relate to slope changes and thermal shifts of the applied load/strain relationships. These effects are studied by using the YF-12A airplane, a structural computer model, and subsequent analyses. Such topics as the thermal environment of the structure, the variation of load paths at elevated temperature, the thermal response characteristics of load equations, elevated-temperature load-measurement approaches, the thermal calibration of wings, and the correlation of strains are discussed. Ways are suggested to measure loads with calibrated strain gages in the supersonic environment.

Jenkins, J. M.↗

Attaching of strain gages to substrates

A method and apparatus for attaching strain gages to substrates is described. A strain gage having a backing plate is attached to a substrate by using a foil of brazing material between the backing plate and substrate. A pair of electrodes that are connected to a current source, are applied to opposite sides of the backing plate, so that heating of the structure occurs primarily along the relatively highly conductive foil of brazing material. Field installations are facilitated by utilizing a backing plate with wings extending at an upward incline from either side of the backing plate, by attaching the electrodes to the wings to perform the brazing operation, and by breaking off the wings after the brazing is completed.

Lemcoe, M. M.↗

Fibre-Optic Semiconductor Temperature Gage

"Safe" temperature gage for explosive liquids is based on optical transmission. Semiconductor crystal inserted between input and output optical fibers is temperature-sensing element in a new approach to measuring temperature of cryogens. Since no electrical components are immersed in liquid, new sensor minimizes danger of electrically ignited explosions in hazardous cryogens such as oxygen and hydrogen. Gage also useful for handling noncryogenic liquids in aircraft, automobiles, boats and water tanks.

Sharma, M.↗

A modified T-value method for selection of strain gages for measuring loads on a low aspect ratio wing

A technique which may be useful for selecting strain gages for use in load equations is described. The technique is an adaptation of the previously used T-value method and is applied to a multispar structure. The technique, called the modified T-value method, is used to reduce the number of strain gages used in a load equation from twelve to two. A parallel reduction is made by calculating relative equation accuracies from three applied load distributions. The equations developed from the modified T-value method proved to be accurate more consistently than the T-value method.

Tang, M. H.↗

Inexpensive Bolt-Load Gage

"Built-in" gage determines whether large bolt or stud has been torqued to desired load and provides for continuous inspection to ensure proper load is being maintained. Gage detects longitudinal stress/strain bolt; requires no electronic or sonic test equipment.

Long, M. J.↗

Electronic Force Gage for Welders

Welding force monitored in process. Electronic force gage uses strain gage on deformable member. Oscilloscope trace of welding force photographed and compared with standard trace during calibration and troubleshooting of resistance welding equipment. Adaptable to small scale resistance welding in electronics industry.

Bradley, J. W.↗

Attaching Strain Gages to Composite Materials

Polyurethane adhesive bonds strain gages reliably to graphite/epoxy composites. Adhesive easy to apply, used over wide temperature range (ambient to cryogenic), and applied in short time. Tests on gages bonded to composite with adhesive demonstrated reliability of attachment.

Penn, B.↗

Creep testing of foil-gage metals at elevated temperature using an automated data acquisition system

A method is being developed to obtain creep data on foil gage metals at elevated temperatures using an automated data acquisition system in conjunction with a mechanically counter balanced extensometer. The automated system components include the Hewlett-Packard (HP) 9845A desktop computer, the HP 3455A digital voltmeter and the HP 3495A scanner. Software for test monitoring and data collection was developed; data manipulation, including curve plotting was done with a HP regression analysis software package. Initial creep tests were conducted on .003 in. thick foil specimens of Ti-6A1-4V at temperatures of 800 F and 1000 F and at stress levels of 25 ksi and 45 ksi. For comparison, duplicate tests were run on .049 in. thick specimens sheet of the same alloy. During testing, the furnace and specimen temperature, bridge voltage, strain and load output were automatically monitored and recorded at predetermined intervals. Using the HP regression analysis program, recorded strain output was plotted as a function of time. These resultant creep curves indicate that, under similar conditions of temperature and stress, foil gage specimens exhibit a higher creep rate than sheet specimens.

Blackburn, L. B.↗

Aerodynamic force measurements with a strain-gage balance in a cryogenic wind tunnel

Aerodynamic force measurements on a generalized 75 deg delta wing model with sharp leading edges were made with a three component internal strain gage balance in a cryogenic wind tunnel at stagnation temperatures of 300 K, 200 K, and 110 K. The feasibility of using a strain gage balance without thermal control in a cryogenic environment as well as the use of electrical resistance heaters, an insulator between the model and the balance, and a convection shield on the balance was investigated. Force and moment data on the delta wing model as measured by the balance are compared at the different temperatures while holding constant either the Reynolds number or the tunnel stagnation pressure. Tests were made at Mach numbers of 0.3 and 0.5 and at angles of attack up to 29 deg. The results indicate that it is feasible to acquire accurate force and moment data while operating at steady state thermal conditions in a cryogenic wind tunnel, either with or without electrical heaters on the balance. Within the limits of the balance accuracy, there were no apparent Reynolds number effects on the aerodynamic results for the delta wind model.

Boyden, R. P.↗

Embedded gage impact study

Impact damage in graphite/epoxy laminates was characterized and transient strain history during impact was correlated. The material investigated was AS-4/3501-6 graphite/epoxy. Eight-ply and sixteen-ply quasi-isotropic laminates of 45/0/-45/90 sub s and 45/0/-45/90 sub 2s layups were fabricated with strain gages embedded between plies during the strain gages and leads from the highly conductive graphite fibers. The specimens were circular plates 12.7 cm (5 in.) in diameter and clamped along their circumference. The specimens were impacted with a 185 gm impactor, dropped from heights of 1.20 m and 1.65 m. An accelerometer was attached to the back surface of the specimen opposite the impact point and was used to trigger the recording instrumentation. The transient strain data were recorded with an eight channel waveform digitizer capable of sampling data at 0.5 microsec intervals. The data were stored, processed, and plotted by means of a microcomputer. Transient strain data were correlated with results from ultrasonic inspection of the specimens.

Schramm, S. W.↗

Elevated-Temperature Tensile-Testing of Foil-Gage Metals

Automated system for measuring strain in metal foils at temperatures above 500 degrees F (260 degrees C) uses mechanical extensometer and displacement transducer. System includes counterbalance feature, which eliminates weight contribution of extensometer and reduces grip pressure required for attachment to specimen. Counterbalancing feature overcomes two major difficulties in using extensometers with foil-gage specimens: (1) Weight of extensometer and transducer represents significant fraction of total load applied to specimen and may actually damage it; and (2) grip pressure required for attachment of extensometer to specimens may induce bending stresses in foil-gage materials.

Blackburn, L. B.↗

Calculating Bearing Forces From Strain-Gage Signals

Technique for obtaining force components on cylindrical bearing holder uses pairs of opposing strain gages. Signals proportional to outputs of pairs of opposing gages subtracted from each other. Subtraction nearly eliminates crosstalk between orthogonal force components. Signal-processing technique equally applicable to rotating as well as stationary loads.

Fenwick, J. R.↗

Closed-loop strain controlled testing at elevated temperatures with a non-contacting gage

Normal strains were measured over a 100 micron gage length at a distance of 50 microns from the edge of a notch using a non-contacting, laser-based interferometric technique. Tests were performed at 600 C under direct strain control from this interferometric 'micro-gage'. A minicomputer system, that produced a voltage analog of strain as a final output, controlled the strain measuring apparatus. This analog output was used directly as the feedback signal to a closed-loop, electrohydraulic mechanical test system. This allowed both strain rate and strain amplitude to be controlled at the notch root of the specimen.

Martin, J. F.↗

Continuous, Multielement, Hot-Film Transition Gage

Accurate measurement of location where laminar boundary layer undergoes transition to turbulent one serves many purposes in basic aero-dynamic research and developmental testing. Individual gages must be staggered to prevent formation of turbulence at gages downstream. This arrangement precludes accurate measurements of laminar/turbulent transition regions along streamline. Complete understanding of performance, stability, and control of laminar-flow airplane requires knowledge of transition locations on wing surface, empennage surfaces, fuselage, and nacelles. Visual, acoustic, and electronic methods capable of providing this transition information.