Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GRID”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?: Preprint

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converterinterfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. An interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a variedlength transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

14 SOLAR ENERGY↗

Definition and implementation of a SAML-XACML profile for authorization interoperability across Grid middleware implementations in OSG and EGEE.

In order to ensure interoperability between middleware and authorization infrastructures used in the Open Science Grid (OSG) and the Enabling Grids for E-science (EGEE) projects, an Authorization Interoperability activity was initiated in 2006. The interoperability goal was met in two phases: firstly, agreeing on a common authorization query interface and protocol with an associated profile that ensures standardized use of attributes and obligations; and secondly implementing, testing, and deploying on OSG and EGEE, middleware that supports the interoperability protocol and profile. The activity has involved people from OSG, EGEE, the Globus Toolkit project, and the Condor project. This paper presents a summary of the agreed-upon protocol, profile and the software components involved.

97 MATHEMATICS AND COMPUTING↗

Precise ROCOF estimation algorithm for low inertia power grids

The precise estimation of Rate Of Change Of Frequencies (ROCOFs) in a generation trip event can be helpful on power system inertia estimation, fast system response, and accurate event capturing. However, the ROCOF estimations from the existing Synchronized Measurement Devices (SMDs) are usually simply calculated by the finite difference between two adjacent frequency measurement points. The ineluctable noises, disturbances, and spikes from real-world frequency measurements can bring large dynamics to the ROCOF estimation and thus can result in an inaccurate estimation of the initial ROCOF. This issue becomes more serious when the target power grid has low inertia, and a large amount of distributed energy sources are deployed. To address this issue, a precise ROCOF estimation algorithm is designed based on least square method with flexible window size. In addition, a median filter is also designed and applied on the frequency measurements before using the proposed algorithm. The window size and thresholds in the proposed algorithm are determined with historical event data analysis. The proposed algorithm is deployed in a low cost, flexible, and distribution level universal grid analyzer (UGA) platform. In conclusion, multiple experiments are conducted in both a laboratory and the Hawaiian Islands to verify the effectiveness of the proposed algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stability analysis of nonlinear two-grid method for multigroup neutron diffusion problems

We present theoretical analysis of a nonlinear acceleration method for solving multigroup neutron diffusion problems. This method is formulated with two energy grids that are defined by (i) fine-energy groups structure and (ii) coarse grid with just a single energy group. The coarse-grid equations are derived by averaging of the multigroup diffusion equations over energy. The method uses a nonlinear prolongation operator. We perform stability analysis of iteration algorithms for inhomogeneous (fixed-source) and eigenvalue neutron diffusion problems. To apply Fourier analysis the equations of the method are linearized about solutions of infinite-medium problems. The developed analysis enables us to predict convergence properties of this two-grid method in different types of problems. Numerical results of problems in 2D Cartesian geometry are presented to confirm theoretical predictions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Emissions impacts and benefits of plug-in hybrid electric vehicles and vehicle-to-grid services

Plug-in hybrid electric vehicles (PHEVs) have been promoted as a potential technology to reduce emissions of greenhouse gases and other pollutants by using electricity instead of petroleum, and by improving electric system efficiency by providing vehicle-to-grid (V2G) services. We use an electric power system model to explicitly evaluate the change in generator dispatches resulting from PHEV deployment in the Texas grid, and apply fixed and non-parametric estimates of generator emissions rates, to estimate the resulting changes in generation emissions. Here, we find that by using the flexibility of when vehicles may be charged, generator efficiency can be increased substantially. By changing generator dispatch, a PHEV fleet of up to 15% of light-duty vehicles can actually decrease net generator NO x emissions during the ozone season, despite the additional charging load. By adding V2G services, such as spinning reserves and energy storage, CO 2 , SO 2 , and NO x emissions can be reduced even further.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An array of virtual Frisch-grid CdZnTe detectors and a front-end application-specific integrated circuit for large-area position-sensitive gamma-ray cameras

We developed a robust and low-cost array of virtual Frisch-grid CdZnTe (CZT) detectors coupled to a front-end readout ASIC for spectroscopy and imaging of gamma rays. The array operates as a self-reliant detector module. It is comprised of 36 close-packed 6x6x15 mm 3 detectors grouped into 3x3 sub-arrays of 2x2 detectors with the common cathodes. The front-end analog ASIC accommodates up to 36 anode and 9 cathode inputs. Several detector modules can be integrated into a single- or multi-layer unit operating as a Compton or a coded-aperture camera. We present the results from testing two fully assembled modules and readout electronics. The further enhancement of the arrays’ performance and reduction of their cost are made possible by using position-sensitive virtual Frisch-grid detectors, which allow for accurate corrections of the response of material non-uniformities caused by crystal defects.

36 MATERIALS SCIENCE↗

Development and Validation of a SiC Based 50 kW Grid-Connected PV Inverter: Preprint

In this digest a 50kW string PV inverter formed using all SiC semiconductor devices is presented. The inverter design includes additively manufactured power block, symmetrical Y-core inductors for ac side filter, and advanced inverter functionality for grid support. This inverter utilizes the conventional three-phase Voltage Source Inverter topology and optimizes the design for SiC based devices. This paper presents the full functional validation of the designed inverter along with quantification of the efficiency and power density. The performance of the inverter for high dc-bus voltage without multi-level topology to exploit SiC advantages is also presented in this digest. The full paper will include details of inverter design, optimization and further experimental validation.

14 SOLAR ENERGY↗

On Stability of PQ-Controlled Grid-Following and Droop-Control Grid-Forming Inverters

In this paper, the nonlinearity impacts of PQ-control schemes and LCL filter parameter variations on the stability of grid-interactive inverters are studied under weak grid conditions. This work demonstrates that the control nonlinearity and parameter variations can cause unexpected instability at low power levels. This instability issue in the nominal operating range may occur under specific control parameters due to the shift of the low-frequency eigenvalues of PQ-controlled inverters. A full-order small-signal model for PQ-controlled inverters is applied to analyze this instability issue. Furthermore, the impacts of the droop coefficients on the stability of the droop-controlled grid-forming inverter are also investigated using the closed-loop inverter model. The findings are experimentally verified using a small-scale two-level 208 V, 5 kVA inverter feeding a 12 kW NHR 9410 power grid emulator and a hardware setup of a microgrid fed by two 5 kVA 208V inverters.

Hossen, Tareq↗

Technology Readiness for the Smart Grid

Reluctance to adopt new technology into a utility application is understandable, given the critical nature of the infrastructure and the less-than-ideal experiences of some power companies. The authors of this paper have considered adapting the NASA approach of classifying technology readiness, but find it not quite appropriate because NASA was both the developer and the eventual user of the new technology it was evaluating, whereas a utility is ordinarily in the mode of a customer, acquiring a new product from a manufacturer. Instead of a generic scale of technology readiness, a scale of readiness is proposed specifically for the smart grid, based on the many standards that exist for the relevant technologies. In this paper we present an overall structure for organization those standards. The acceptance of new technology is organized into five SGL (Smart Grid Level) steps, numbered five through 9 to correspond approximately to the last five numbers of the NASA TRL scale. SGL 5 is a certification that the hardware and software of the technology is safe for the system into which is intended to be placed. SGL 6 is documentation that the system is safe for itself, and will have adequate reliability. It is thus clear that the steps differ from NASA’s TRL in that technology development is not required, the transition is more one of documenting already existing system readiness. Since SGL 6 describes a system that is safe for the power system and for itself, it should not be restricted from being in a pilot-scale study, and achieving SGL 7. A larger-scale demonstration in a realistic environment will demonstrate interoperability and achieve SGL 8. Only when systems are installed and operating, and when disposal plans are in place will the designation of fully operable at SGL 9 be granted.

Kirkham, Harold↗

Modeling DNP3 Traffic Characteristics of Field Devices in SCADA Systems of the Smart Grid

In the generation, transmission, and distribution sectors of the smart grid, intelligence of field devices is realized by programmable logic controllers (PLCs). Many smart-grid subsystems are essentially cyber-physical energy systems (CPES): For instance, the power system process (i.e., the physical part) within a substation is monitored and controlled by a SCADA network with hosts running miscellaneous applications (i.e., the cyber part). To study the interactions between the cyber and physical components of a CPES, several co-simulation platforms have been proposed. However, the network simulators/emulators of these platforms do not include a detailed traffic model that takes into account the impacts of the execution model of PLCs on traffic characteristics. As a result, network traces generated by co-simulation only reveal the impacts of the physical process on the contents of the traffic generated by SCADA hosts, whereas the distinction between PLCs and computing nodes (e.g., a hardened computer running a process visualization application) has been overlooked. To generate realistic network traces using co-simulation for the design and evaluation of applications relying on accurate traffic profiles, it is necessary to establish a traffic model for PLCs. In this work, we propose a parameterized model for PLCs that can be incorporated into existing co-simulation platforms. We focus on the DNP3 subsystem of slave PLCs, which automates the processing of packets from the DNP3 master. To validate our approach, we extract model parameters from both the configuration and network traces of real PLCs. Simulated network traces are generated and compared against those from PLCs. Our evaluation shows that our proposed model captures the essential traffic characteristics of DNP3 slave PLCs, which can be used to extend existing co-simulation platforms and gain further insights into the behaviors of CPES.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Demonstrating Distribution System Resiliency through Grid-Edge Microgrids, on a Multi-Site Networked Hardware-in-Loop Platform

With the increasing penetration of Distributed Energy Resources (DERs) at the grid-edge, power systems include more energy storage, remote switches, relays, voltage regulators, and other intelligent electronic devices (IED). Effective control of these grid-edge devices by using Advanced Distribution Management Systems (ADMS) can yield substantial improvements to the resiliency and power quality of distribution systems. In this paper, improvements to the resiliency of a distribution system are demonstrated using a multi-site evaluation environment consisting of a real-time Hardware-in-Loop (HIL) setup in which DERs and other IEDs are modeled; and an ADMS which monitors and is able to control the distribution system assets. The HIL model and the ADMS are located 2400 km away, with communication between the sites enabled by a data manager using Distributed Network Protocol 3 (DNP3), demonstrating the system's capabilities even over long distances. After a simulated transmission system failure in the HIL demonstration setup, DERs and other devices are operated to restore critical loads and node voltage profile (to within the 'nominal +/-5%' band) in the distribution system.

ADMS↗

Experimental Evaluation of Load Rejection Over-Voltage from Grid-Tied Solar Inverters

This paper investigates the impact of load rejection over-voltage (LRO) from commercially available grid-tied photovoltaic (PV) solar inverters. LRO can occur when a local feeder or breaker opens and the power output from a distributed energy resource exceeds the load power. Simplified models of current controlled inverters can over-predict over-voltage magnitudes, thus it is useful to quantify testing. The load rejection event was replicated using a hardware testbed at the National Renewable Energy Laboratory (NREL), and a set of commercially available PV inverters was tested to quantify the impact of LRO for a range of generation-to-load ratios. The magnitude and duration of the over-voltage events are reported in this paper along with a discussion of characteristic inverter output behavior. The results for the inverters under test showed that maximum over-voltage magnitudes were less than 200 percent of nominal voltage, and much lower in many test cases. These research results are important because utilities that interconnect inverter-based DER need to understand their characteristics under abnormal grid conditions.

14 SOLAR ENERGY↗

Robust Restoration From Cyber-Physical Attacks in Active Distribution Grids With Grid-Edge IBRs

The inverter-based resources (IBRs) have enabled the integration of renewable energy at the grid edge with enhanced control capabilities to support the reliable operation of power grids. Different control frameworks, such as hierarchical or distributed architecture, have been proposed with the expansion of cyber networks for real-time monitoring and control. This evolution of critical infrastructure into cyber-physical systems also brings more vulnerabilities for the broadened attack surfaces, and significantly increases the possibility of physical system failures or outages caused by cyberattacks. Among tremendous efforts in the defense-in-depth approach, it remains challenging to provide prompt detection and accurate location of attack entry points or paths. Therefore, the prevailing restoration framework may struggle to fully consider the cyber-physical interdependence, successfully isolate the compromised cyber and physical components, and safely recover the systems without the potential risks leading to secondary outages. This paper is motivated to develop a cyber-physical restoration framework for distribution grids to recover from cyber attacks by harnessing grid-edge IBRs. The framework is first built on the operational guidelines of IBRs considering the compromised cyber layer. Then, an ambiguity set is established to represent the uncertainty of attack scenarios and their possibility levels. Next, a distributionally robust optimization model is developed to provide the optimal load restoration strategy across all scenarios. The effectiveness of the proposed model is demonstrated through various use cases on the modified IEEE 13-node and 123-node test systems. Finally, simulation results demonstrate the effectiveness and advancement of developed post-attack restoration strategies.

Cybersecurity↗

FY2021 Isolated Grids and Grid-Connected Turbine Reference Systems

For individuals, businesses, and communities focused on building resilient electrical grid infrastructure, wind energy can provide an affordable, accessible, and compatible distributed energy resource option that also enhances the capabilities of local grid operations. However, there are technical barriers to realizing the market value and resilience benefits of distributed wind, and there is little to no ability to quantify those benefits so that stakeholders can compare grid investment options. The central aims of this report are: (1) to drive technology transfer of the methods and technologies developed under the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) project and (2) increase the number of referenceable case studies available to stakeholders interested in additional value-added capabilities of wind systems beyond bulk energy supply. We achieve this aim by applying three major methods developed under MIRACL to two real-world distributed wind reference systems. The two real-world distributed wind reference systems are the isolated grid of St. Mary’s, Alaska, and the two 10.5-megawatt (MW) front-of-the-meter wind turbine deployments owned and operated by Iowa Lakes Electric Cooperative (ILEC).

17 WIND ENERGY↗

An Overview of Arizona's Electric Grid Resilience Using TASTI-GRID

This document provides a concise overview of the analytical capabilities of the TASTI-GRID team. Utilizing additional data and resources, it synthesizes platform insights to present a distinct perspective on investing in grid resilience throughout Mississippi. This document is not intended to influence or direct state- level decisions related to investments in grid resilience and reliability. TASTI-GRID should not be used for real-time monitoring, supporting the ESF #12 emergency response functions, or predicting the restoration times for outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TASTI-GRID: An Overview of Minnesota's County and Tribal Electric Grid Resilience

This document provides a concise overview of the analytical capabilities of the TASTI-GRID team. Utilizing additional data and resources, it synthesizes platform insights to present a distinct perspective on investing in grid resilience throughout Mississippi. This document is not intended to influence or direct state- level decisions related to investments in grid resilience and reliability. TASTI-GRID should not be used for real-time monitoring, supporting the ESF #12 emergency response functions, or predicting the restoration times for outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗