At least 199 records · Page 11

In-glovebox container

A container having two different closing mechanism designs including an upright strike-less latch design and a Buttress thread design.

Oka, Jude M.↗

Evaluation Of Elbow Exoskeleton in Glovebox Operations To Minimize Injuries – 25704

In nuclear facilities across the DOE, ergonomic injuries pose a significant occupational hazard for GB workers. Recent studies at Los Alamos National Laboratory (LANL) have revealed concerning trends in worker health, with approximately 50% of GB workers reporting musculoskeletal symptoms after 25 years of service [1]. The current GB design, largely unchanged since the 1960s, presents several ergonomic challenges including inappropriate finger lengths, nonexistent joint angles, and incorrect thumb placement. These design flaws directly contribute to conditions such as lateral epicondylitis (tennis elbow) and De Quervain's tenosynovitis which causes pain and inflammation in the tendons at the base of the thumb. These are examples of conditions caused by workers performing repetitive precision tasks [2].

Ramon, Rodrigo N. [Savannah River National Laborat↗

A Novel and Cost Effective Approach to the Decommissioning and Decontamination of Legacy Glove Boxes - Minimizing TRU Waste and Maximizing LLW Waste - 13634

This paper describes the process of decommissioning two gloveboxes at the Argonne National Laboratory (ANL) that were employed for work with plutonium and other radioactive materials. The decommissioning process involved an initial phase of clearing tools and materials from the glove boxes and disconnecting them from the laboratory infrastructure. The removed materials, assessed as Transuranic (TRU) waste, were packaged into 55 gallon (200 litre) drums and prepared for ultimate disposal at the Waste Isolation Pilot Plant (WIPP) at Carlsbad New Mexico. The boxes were then sampled to determine the radioactive contents by means of smears that were counted with alpha and beta detectors to determine the residual surface contamination, especially in terms of alpha particle emitters that are an indicator of TRU activity. Paint chip samples were also collected and sent for laboratory analysis in order to ascertain the radioactive contamination contributing to the TRU activity as a fixed contamination. The investigations predicted that it may be feasible to reduce the residual surface contamination and render the glovebox structure low level waste (LLW) for disposal. In order to reduce the TRU activity a comprehensive decontamination process was initiated using chemical compounds that are particularly effective for lifting and dissolving radionuclides that adhere to the inner surfaces of the gloveboxes. The result of the decontamination process was a reduction in the TRU surface activity on the inner surfaces of the gloveboxes by four orders of magnitude in terms of disintegrations per unit area (DPA). The next phase of the process involved a comprehensive assay of the gloveboxes using a combination of passive neutron and gamma ray scintillation detectors and a shielded and collimated high purity Germanium (HPGe) gamma ray detector. The HPGe detector was used to obtain gamma ray spectra for a variety of measurement positions within the glovebox. The spectra were used to determine the TRU content of the boxes by assessing the activity of Am-241 (59 keV) and Pu-241 (414 keV). Using the data generated it was possible for qualified subject matter experts (SME) to assess that the gloveboxes could be consigned for disposition as LLW and not as TRU. Once this determination was assessed and accepted the gloveboxes were prepared for final disposition to the Nevada National Security Site (NNSS) - formerly the Nevada Test Site (NTS). This preparation involved fixing any remaining radioactive contamination within the gloveboxes by filling them with a foam compound, prior to transportation. Once the remaining contamination was fixed the gloveboxes were removed from the laboratory and prepared for transported by road to NNSS. This successful glovebox decontamination and decommissioning process illustrates the means by which TRU waste generation has been minimized, LLW generation has been maximized, and risk has been effectively managed. The process minimizes the volume of TRU waste and reduced the decommissioning time with significant cost savings as the result. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Developing a new criticality methodology to support decommissioning of legacy plutonium facilities

To decommission a legacy plutonium finishing facility, a number of gloveboxes need to be disposed of. These gloveboxes have been in place since the 1960's and were operational until the 1980's. A period of initial clean out and decommissioning took place in the 1990's and the first gloveboxes were removed from the line in the early 2000's. Compliance with downstream waste handling facility requirements meant that the gloveboxes needed to be removed using intensive 'hands-on' methods in order to size reduce them to fit into 200 litre (55 gallon) drums. This is the standard approach for handling waste items known as Plutonium Contaminated Material (PCM) on the Sellafield site and was credited in the criticality safety case for the decommissioning of the gloveboxes as it allowed each waste drum to be individually assayed such that the fissile content of the waste could be known. Not only was this approach time-consuming and laborious but as it involved operators working with cutting tools in a highly contaminated area it was challenged as being overly restrictive to operations and potentially hazardous to the workers. In order to decommission the remaining nine gloveboxes in the facility, a new decommissioning approach and associated criticality methodology has been developed. Instead of intensive size reduction and waste drum assay, the gloveboxes will be removed with little or no size reduction and put into storage crates without assay. The criticality assessor will review the operational history of each glovebox, along with the decommissioning records and relevant plant data, to make an evidence-based judgement that the crated glovebox represents no greater a residual criticality risk than would have been realised from the equivalent number of PCM drums that the standard decommissioning approach would have generated. This method identifies, in conjunction with the plant personnel, a number of review points to ensure that before the glovebox is removed any bulk residue material has been recovered and no more than a safe amount of moderating material (fixative) has been added to fix any remaining fissile contamination. Finally, once these review points have been confirmed to be complete - through a stakeholder meeting with criticality safety, plant operators and project managers - the glovebox will be placed in a crate, and this crate will be declared a Low Criticality Risk crate. No formal assay will be required prior to exporting the crate to the downstream waste handling facility and no fissile mass value will be assigned to the contents of the crate. No further intrusive work will be required on the crate and it can be safely stored without any spacing requirements, pending final disposal. (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Remotely Teleoperating a Humanoid Robot to Perform Fine Motor Tasks with Virtual Reality - 18446

In this paper, we describe our ongoing work to develop cooperative control of NASA's R5 Valkyrie humanoid robot for performing dexterous manipulation tasks inside gloveboxes commonly found in many nuclear facilities. These tasks can be physically demanding and provide some element of risk to the operator when done by a person in situ. For example, if a glove is ruptured, the operator could be exposed to radioactive material. In many cases, the operator has low visibility and is unable to reach the entire task space, requiring the use of additional tools located inside the glovebox. Such tasks include cleaning particulate from inside the glovebox via sweeping or vacuuming, separating a specific amount of a compound to be weighed on a scale, or grasping and manipulating objects inside the glovebox. There is potential to move the operator to a nearby, safe location and instead place a humanoid robot in the potentially hazardous environment. However, teleoperating a humanoid robot to perform dexterous tasks at a comparable level to a human hand remains a difficult problem. Previous work for controlling humanoid robots often involves one or more operators using a standard 2D display with a mouse and keyboard as controllers. Successful interfaces use sensor fusion to provide information to the operator for increased situation awareness, but these designs have limitations. Gaining proper situation awareness by visualizing 3D information on a 2D screen requires time and increases the cognitive load on the user. Instead, if the operator is able to visualize and control the robot properly in three dimensions, it can increase situation and task awareness, reduce task time, reduce the chance of mistakes, and increase the likelihood of overall task success. We propose a two-part system that combines an HTC Vive virtual reality headset with either the Vive handheld controllers, or the Manus VR wearable gloves as the primary control. The operator wears the headset in a remote location and can visualize a reconstruction of the glovebox, created live by sensor scans from the robot and with sensors located inside the glovebox for a perspective traditionally unavailable to operators. By using the controllers or gloves to control the humanoid robots hands directly, they can plan actions in the virtual reconstruction. When the operator is satisfied with the plan, the actions are sent to the real robot. To test this system we have created a mockup of a glovebox that is accessible by Valkyrie, as well as several tasks that are a subsample of the tasks that might be required when working in a real glovebox. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Conceptual Approach For Estimating Potential Air Toxics And Radionuclide Airborne Emissions From A Temporary Exhaust System For The 216-Z-9 Crib Removal Action

The 216-Z-9 Crib, located at the Hanford Nuclear Reservation in southeastern Washington State, was the site of a successful mining effort to recover plutonium from the contaminated soils at the disposal site. A CERCLA Action Memorandum (AM) issued by the U.S. Department of Energy (DOE) requires the removal of the buildings associated with this mining effort to facilitate a remedial action planned for the near future. The decontamination and demolition of the 216 Z-9 Crib facilities is required under a consent order between the DOE, the U.S Environmental Protection Agency (EPA) and the Washington State Department of Ecology (Ecology). Removal of the buildings located on and near the concrete cover slab over the 216-Z-9 Crib will require removal of the large soil-packaging glovebox located inside the 216-Z- 9A Building. Prior to cleaning out the glovebox, it will be necessary to provide active filtered ventilation capability to ensure a negative pressure exists between the glovebox and the adjacent airspace while hands-on work proceeds within. The glovebox floor is open to the Z-9 crib cavern environment below. For this reason the crib and glovebox currently share a common airspace. The functional requirements for safely conducting work within the glovebox include provision of a negative pressure in the box of about 0.5 inches of water gage (nominal) less than the interior of the building. In addition, the building surrounding the glovebox will be maintained at a slight negative pressure with respect to outdoor ambient pressure. In order to assess the relevant and appropriate clean air requirements for the new temporary ventilation system and associated emissions monitoring, it was necessary to reliably predict the nature of the exhaust air stream. Factors used to predict the presence and concentrations of certain radionuclide particulates and certain gases considered to be air toxics, included reliability parameters, flow rates, radionuclide content, and off-gas compositions. Radionuclide content includes transuranic isotopes, primarily of plutonium and americium. Air toxics include carbon tetrachloride, butane, methanol, acetone and toluene. Flow rate prediction was based on available design and test data and considered equipment sizes, glovebox negative pressure requirements, and filter flow characteristics. The approach used to predict the off-gas composition from the crib required experience-based predictive analysis combined with crib head space analytical results. Input information for emission estimates included: (1) gas composition sample data obtained from recent samples taken within the crib head space during static conditions, and (2) air in-leakage/dilution estimates based on physical characteristics of both the crib and the new temporary ventilation system. The conceptual approach combined measurement-based data with conservative assumptions, and provides the estimates necessary to determine relevance and appropriateness of substantive requirements under federal and state laws and regulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Geolab 2010: Desert Rats Field Demonstration

In 2010, Desert Research and Technology Studies (Desert RATS), NASA's annual field exercise designed to test spacesuit and rover technologies, will include a first generation lunar habitat facility, the Habitat Demonstration Unit (HDU). The habitat will participate in joint operations in northern Arizona with the Lunar Electric Rover (LER) and will be used as a multi-use laboratory and working space. A Geology Laboratory or GeoLab is included in the HDU design. Historically, science participation in Desert RATS exercises has supported the technology demonstrations with geological traverse activities that are consistent with preliminary concepts for lunar surface science Extravehicular Activities (EVAs). Next year s HDU demonstration is a starting point to guide the development of requirements for the Lunar Surface Systems Program and test initial operational concepts for an early lunar excursion habitat that would follow geological traverses along with the LER. For the GeoLab, these objectives are specifically applied to support future geological surface science activities. The goal of our GeoLab is to enhance geological science returns with the infrastructure that supports preliminary examination, early analytical characterization of key samples, and high-grading lunar samples for return to Earth [1, 2] . Figure 1: Inside view schematic of the GeoLab a 1/8 section of the HDU, including a glovebox for handling and examining geological samples. Other outfitting facilities are not depicted in this figure. GeoLab Description: The centerpiece of the GeoLab is a glovebox, allowing for samples to be brought into the habitat in a protected environment for preliminary examination (see Fig. 1). The glovebox will be attached to the habitat bulkhead and contain three sample pass-through antechambers that would allow direct transfer of samples from outside the HDU to inside the glovebox. We will evaluate the need for redundant chambers, and other uses for the glovebox antechambers, such as a staging area for additional tools or samples. The sides of the glovebox are designed with instrument ports and additional smaller ports for cable pass-through, imagery feeds and environmental monitoring. This first glovebox version will be equipped with basic tools for manipulating, viewing, and early analysis of samples. The GeoLab was also designed for testing additional analytical instruments in a field setting.

Evans, Cindy A.↗

Transuranic (Tru) waste volume reduction operations at a plutonium facility

Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA 55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through use of a variety of gloveboxes (the glovebox, coupled with an adequate negative pressure gradient, provides primary confinement). Size-reduction operations on glovebox equipment are a common activity when a process has been discontinued and the room is being modified to support a new customer. The Actin ide Processing Group at TA-55 uses one-meter-long glass columns to process plutonium. Disposal of used columns is a challenge, since they must be size-reduced to get them out of the glovebox. The task is a high-risk operation because the glass shards that are generated can puncture the bag-out bags, leather protectors, glovebox gloves, and the worker's skin when completing the task. One of the Lessons Learned from these operations is that Laboratory management should critically evaluate each hazard and provide more effective measures to prevent personnel injury. A bag made of puncture-resistant material was one of these enhanced controls. We have investigated the effectiveness of these bags and have found that they safely and effectively permit glass objects to be reduced to small pieces with a plastic or rubber mallet; the waste can then be easily poured into a container for removal from the glove box as non-compactable transuranic (TRU) waste. This size-reduction operation reduces solid TRU waste generation by almost 2% times. Replacing one-time-use bag-out bags with multiple-use glass crushing bags also contributes to reducing generated waste. In addition, significant costs from contamination, cleanup, and preparation of incident documentation are avoided. This effort contributes to the Los Alamos National Laboratory Continuous Improvement Program by improving the efficiency, cost-effectiveness, and formality of glovebox operations. In this report, the technical issues, associated with implementing this process improvement are addressed, the results discussed, effectiveness of Lessons Learned evaluated, and waste savings presented.

57↗

Plutonium Oxide Containment and the Potential for Water-Borne Transport as a Consequence of ARIES Oxide Processing Operations

The question of oxide containment during processing and storage has become a primary concern when considering the continued operability of the Plutonium Facility (PF-4) at Los Alamos National Laboratory (LANL). An Evaluation of the Safety of the Situation (ESS), “Potential for Criticality in a Glovebox Due to a Fire” (TA55-ESS-14-002-R2, since revised to R3) first issued in May, 2014 summarizes these concerns: “The safety issue of fire water potentially entering a glovebox is: the potential for the water to accumulate in the bottom of a glovebox and result in an inadvertent criticality due to the presence of fissionable materials in the glovebox locations and the increased reflection and moderation of neutrons from the fire water accumulation.” As a result, the existing documented safety analysis (DSA) was judged inadequate and, while it explicitly considered the potential for criticality resulting from water intrusion into gloveboxes, criticality safety evaluation documents (CSEDs) for the affected locations did not evaluate the potential for fire water intrusion into a glovebox.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Remote Decommissioning of the Plutonium Experimental Extraction Facility, Sellafield - 17031

A redundant suite of gloveboxes formerly used for an experimental plutonium extraction process required decommissioning to avoid further degradation and a risk to other users of the Analytical Services building on Sellafield site. Following a full option selection process, remote techniques were chosen as the most appropriate (i.e. ALARP) decommissioning method. A nearby ventilation system from a previous project was re-engineered to ventilate the laboratory. Gloveboxes in neighbouring labs were cleared to create space to install a personnel access facility. The containment was reinforced where necessary to provide adequate protection from the remote machinery. Following a campaign of manual waste removal, including approximately 21 tonnes of lead chevron bricks released as exempt waste, a Brokk{sup R} 90 remotely-operated vehicle (ROV) was deployed to perform remote size reduction of the glovebox suite. The resulting plutonium-contaminated material (PCM) was delivered to a Kraft Raptor manipulator for sorting and consignment to an on-site store in 200-litre drums. Despite indications from pre-decommissioning surveys of the presence of ILW in the shielded section, none was found. Following the successful removal of the glovebox suite, and the emergence during the project of additional redundant gloveboxes within the Analytical Services building, the Remediation team has taken the opportunity to retain the decommissioning infrastructure as a remote glovebox breakdown facility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design and Development of a Robotic Exoskeleton Device for use in Glove Boxes - 20374

Glovebox operators in nuclear facilities often operate under radioactive environment and typically perform monotonous, dull and repetitive work. This can result in muscle fatigue leading to increased levels of accidents. Current research work aims in assisting the glovebox operators by designing a novel upper limb exoskeleton device to reduce injuries and increase worker efficiency. Almost none of the commercially available hand and upper body exoskeletons are directly suitable for use in gloveboxes. This explains the novelty of the present work in developing a wearable powered robotic exoskeleton device. The device consists of electronics, motors and spring systems mounted on adjustable plates and is supported by a stationary frame behind the worker. The device is intended to be portable and adjustable according to the operator height. The elbow has a flexion movement assisted with motor control by way of a Bowden cable system. The system is floated on a spring and pulley combination that allows for extra safety and smoothness of operation. The end points are fixed near the pivot points to help minimize unwanted movement/torque. The extension movement of the upper and lower arm are assisted by gravity and a counter spring. The shoulder and upper arm movement are held in a neutral position with a spring system for counter balance allowing small movements within the glovebox. This initial concept considers only the vertical movement of the arm. The abduction and adduction movement will not be assisted or impeded by the over shoulder plate or at the forearm plate allowing for full range of motion. Several glovebox aspects such as the level of task assistance, ergonomic design, minimum hindrance in dexterity/operator movements and tear resistance for hazardous safety reasons will be considered in the design of the exoskeleton. Computer models will be simulated to test the load levels and stress conditions on the exoskeleton to enhance the designs. The exoskeleton focusses on major muscular involvement reduction through weight offset and active assistance with minimal parts and hence the device is derived with several joint links and contains both passive and active joints. The paper details the various stages in the design development and prototype testing of the exoskeleton device. Upon successful prototype device development, human testing will be conducted in a replica of the SRS-235F hot cell facility constructed at FIU-ARC. The final stage of the project will be potential testing/deployment of the exoskeleton device in one of the glovebox facilities in Savannah River Nuclear Waste site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reducing Organic Contamination in NASA JSC Astromaterial Curation Facility

Future robotic and human spaceflight missions to the Moon, Mars, asteroids and comets will require handling and storing astromaterial samples with minimal inorganic and organic contamination to preserve the scientific integrity of each sample. Much was learned from the rigorous attempts to minimize and monitor organic contamination during Apollo, but it was not adequate for current analytical requirements; thus [1]. OSIRIS-REx, Hayabusa-2, and future Mars sample return will require better protocols for reducing organic contamination. Future isolation con-tainment systems for astromaterials, possibly nitrogen enriched gloveboxes, must be able to reduce organic and inorganic cross-contamination. In 2012, a baseline study established the current state of organic cleanliness in gloveboxes used by NASA JSC astromaterials curation labs that could be used as a benchmark for future mission designs [2, 3]. After standard ultra-pure water (UPW) cleaning, the majority of organic contaminates found were hydrocarbons, plasticizers, silicones, and solvents. Hydro-carbons loads (> C7) ranged from 1.9 to 11.8 ng/cm2 for TD-GC-MS wafer exposure analyses and 5.0 to 19.5 ng/L for TD-GC-MS adsorbent tube exposure. Plasticizers included < 0.6 ng/cm2 of DBP, DEP, TXIB, and DIBP. Silicones included < 0.5 ng/cm2 of cyclo(Me2SiO)x (x = 6, 8, 9, 10) and siloxane. Solvents included < 1.0 ng/cm2 of 2-cyclohexen-1-one, 3,5,5-trimethyl- (Isopho-rone), N-formylpiperidine, and 2-(2-butoxyethoxy) ethanol. In addition, DBF, rubber/polymer additive was found at < 0.2 ng/cm2 and caprolactam, nylon-6 at < 0.6 ng/cm2. Reducing Organics: The Apollo program was the last sam-ple return mission to place high-level organic requirements and biological containment protocols on a curation facility. The high vacuum complex F-201 glovebox in the Lunar Receiving Labora-tory used ethyl alcohol (190 proof), 3:1 benzene/methanol (nano grade solution), and heat sterilization at 130degC for 48 hours to reduce organic contamination. In addition, both heat sterilization and peracetic acid sterilization were used in the atmospheric de-contamination (R) cabinets. Later, Lunar curation gloveboxes were degreased with a pressurized Freon 113 wash. Today, UPW has replaced Freon as the standard cleaning procedure, but does not have the degreasing solvency power of Freon. Future Cleaning Studies: Cleaning experiments are cur-rently being orchestrated to study how to degrease and reduce organics in a JSC curation glovebox lower than the established baseline. Several new chemicals in the industry have replaced traditional degreasing solvents such as Freon and others that are now federally restricted. However, these new suites of chemicals remain untested for lowering organics in curation gloveboxes. 3M's HFE-7100DL and DuPont's Vertrel XF are currently being tested as a replacement for Freon 113 as a degreaser at JSC cura-tion facilities. In addition, the use of UPW as a final rinse is be-ing tested, which presumably can maintain a lower total organic carbon load than the filtered purity of chemical solutions. References: [1] Allton J.H. et al. (2012) LPS XLIII, 2439; [2] Calaway M.

Calaway, M. J.↗

Implementation of a System of Gamma Imagers for Measuring Plutonium Holdup

The Surplus Plutonium Disposition (SPD) project is an effort to dilute and dispose of many tonsof weapons grade plutonium. This work will take place in a shielded glovebox to protect workers fromradiological dose. Accurate measurements of the holdup, or material left behind, in the gloveboxes is im-portant for Nuclear Material Control and Accountancy, worker dose minimization, criticality safety, andprocess monitoring. Shielding around the gloveboxes presents an obstacle for the traditional GeneralizedGamma Holdup (GGH) method. The uncertainties associated with that method, at around 28%, arealso detrimental since the amount of holdup must be kept below an established limit with a high level ofconfidence.Passive gamma-ray imaging provides a more complete depiction of the distribution of radioactivematerials. Recent refinement of the method has demonstrated that quantitative information can beextracted from the images with a well-characterized system. A permanently installed system of gamma-ray imagers is currently being developed to measure plutonium holdup in the SPD gloveboxes. Thispaper will report on progress with the development of this system.This application requires that the features of current commercially available instruments from H3Dand PHDS, optimized for measurement performance in a mobile application, be translated into theconstraints of the operational environment with fixed installations. The interaction between facilityconstraints and measurement capabilities will be addressed.A series of measurements with plutonium sources in a mocked-up glovebox geometry with imagersmounted above the ceiling of the glovebox have been taken. Imager performance with respect to angularresolution, minimum measurement time for quantification, and signal-to-noise ratio with a multitudeof sources will be evaluated for those measurements. A series of prototypes of user interfaces will bepresented for display of the data to its various consumers for the purposes of Nuclear Material Controland Accountancy, worker dose minimization, criticality safety, and process monitoring.

Schmitt, Kyle↗

Custom Equipment Development for Processing of Surplus Plutonium

The Strategic Laboratory Assessment (SLA), a collaborative team of SRNL and ORNL personnel, has been established to advance the objectives of the Surplus Plutonium Disposition (SPD) Project, by identifying and developing technologies to accelerate disposition, reduce life cycle costs, minimize worker radiation exposure, improve worker safety, and minimize Surplus Plutonium Disposition Program risks. [1] The SLA team has identified can cutting and plutonium (Pu) oxide size reduction as two glovebox processes where technology enhancements would be valuable. The DOE&#x2;STD-3013 package currently in use for Pu downblending requires cutting two nested cans before the inner convenience can that holds the Pu oxide may be accessed for further processing. A rotary tubing-style cutter is used for opening the 3013 packages within the glovebox. Collet changeouts are required between cutting of the outer and inner cans. The SLA team is currently developing and testing an adjustable-clamp can cutter design that eliminates collet changeouts and allows cutting of the outer and inner can at the same time, resulting in significant reduction of radiological dose and process time, as well as improved ergonomics. To meet the Pu oxide particle size requirement, size reduction of Pu oxide agglomerations must be performed within the process gloveboxes. The SLA team has identified jaw crushing technology as an alternative to the currently employed rotary mill. Jaw crusher advantages include reduced dust within the glovebox, increased batch sizes, and easier integration with other glovebox processes due to the flow-through nature of jaw crushing. Commercially manufactured jaw crushers are either too large and/or too heavy for implementation in the SPD gloveboxes, so the SLA team is developing and testing a custom jaw crusher to meet the needs of the SPD Project.

Krementz, Daniel [Savannah River National Laborato↗

Verification study of an emerging fire suppression system

Self-contained fire extinguishers are a robust, reliable and minimally invasive means of fire suppression for gloveboxes. Moreover, plutonium gloveboxes present harsh environmental conditions for polymer materials; these include radiation damage and chemical exposure, both of which tend to degrade the lifetime of engineered polymer components. Several studies have been conducted to determine the robustness of selfcontained fire extinguishers in plutonium gloveboxes in a nuclear facility, verification tests must be performed. These tests include activation and mass loss calorimeter tests. In addition, compatibility issues with chemical components of the self-contained fire extinguishers need to be addressed. Our study presents activation and mass loss calorimeter test results. After extensive studies, no critical areas of concern have been identified for the plutonium glovebox application of Fire Foe™, except for glovebox operations that use large quantities of bulk plutonium or uranium metal such as metal casting and pyro-chemistry operations.

42 ENGINEERING↗