Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fourier transforms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Internal energy of HCl upon photolysis of 2-chloropropene at 193 nm investigated with time-resolved Fourier-transform spectroscopy and quasiclassical trajectories

Following photodissociation of 2-chloropropene (H{sub 2}CCClCH{sub 3}) at 193 nm, vibration-rotationally resolved emission spectra of HCl ({upsilon}{<=}6) in the spectral region of 1900-2900 cm{sup -1} were recorded with a step-scan time-resolved Fourier-transform spectrometer. All vibrational levels show a small low-J component corresponding to {approx}400 K and a major high-J component corresponding to 7100-18 700 K with average rotational energy of 39{+-}{sub 3}{sup 11} kJ mol{sup -1}. The vibrational population of HCl is inverted at {upsilon}=2, and the average vibrational energy is 86{+-}5 kJ mol{sup -1}. Two possible channels of molecular elimination producing HCl+propyne or HCl+allene cannot be distinguished positively based on the observed internal energy distribution of HCl. The observed rotational distributions fit qualitatively with the distributions of both channels obtained with quasiclassical trajectories (QCTs), but the QCT calculations predict negligible populations for states at small J. The observed vibrational distribution agrees satisfactorily with the total QCT distribution obtained as a weighted sum of contributions from both four-center elimination channels. Internal energy distributions of HCl from 2-chloropropene and vinyl chloride are compared.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fourier-transform spectroscopy and coupled-channels deperturbation treatment of the A {sup 1{Sigma}+}-b {sup 3{Pi}} complex of KCs

The laser-induced fluorescence (LIF) A {sup 1{Sigma}+}-b {sup 3{Pi}{yields}}X {sup 1{Sigma}+} spectra of the KCs molecule were recorded in a near infrared region by a Fourier-transform spectrometer with a resolution of 0.03 cm{sup -1}. Overall more than 200 collisionally enhanced LIF spectra were rotationally assigned to {sup 39}K{sup 133}Cs and {sup 41}K{sup 133}Cs isotopomers yielding more than 3400 rovibronic term values of the strongly mixed singlet A {sup 1{Sigma}+} and triplet b {sup 3{Pi}} states with the uncertainty of 0.003-0.01 cm{sup -1}. Experimental data massive starts from the lowest vibrational level v{sub A}=0 of the singlet and nonuniformly covers the energy range E is an element of [10 040,13 250] cm{sup -1} with rotational quantum numbers J{sup '} is an element of [7,225]. Besides the dominating regular A {sup 1{Sigma}+}-b {sup 3{Pi}}{sub {Omega}=0} interactions, the weak local heterogeneous A {sup 1{Sigma}+}-b {sup 3{Pi}}{sub {Omega}=1} perturbations have been discovered and analyzed. Coupled-channels deperturbation analysis of the experimental {sup 39}K{sup 133}Cs e-parity term values of the A {sup 1{Sigma}+}-b {sup 3{Pi}}{sub {Omega}=0,1,2} complex was accomplished in the framework of the phenomenological 4x4 Hamiltonian accounting implicitly for regular interactions with the remote {sup 1{Pi}} and {sup 3{Sigma}+} states. The diabatic potential energy curves of the A {sup 1{Sigma}+} and b {sup 3{Pi}} states, as well as relevant spin-orbit coupling matrix elements, were defined analytically with the expanded Morse oscillators model. The obtained parameters reproduce 95% of experimental data field of the {sup 39}K{sup 133}Cs isotopomer with a standard deviation of 0.004 cm{sup -1}, which is consistent with the uncertainty of the experiment. Reliability of the derived parameters was confirmed by a good agreement between the predicted and experimental term values of the {sup 41}K{sup 133}Cs isotopomer. The calculated relative intensity distributions in A-b{yields}X LIF progressions are also consistent with their experimental counterparts. The deperturbation model was applied for simulation of a pump-dump optical cycle a {sup 3{Sigma}+{yields}}A {sup 1{Sigma}+}-b {sup 3{Pi}{yields}}X {sup 1{Sigma}+} proposed for transformation of ultracold KCs molecules to their absolute ground state v{sub X}=0;J{sub X}=0.

74 ATOMIC AND MOLECULAR PHYSICS↗

Applications of Micro-Fourier Transform Infrared Spectroscopy (FTIR) in the Geological Sciences—A Review

Fourier transform infrared spectroscopy (FTIR) can provide crucial information on the molecular structure of organic and inorganic components and has been used extensively for chemical characterization of geological samples in the past few decades. In this paper, recent applications of FTIR in the geological sciences are reviewed. Particularly, its use in the characterization of geochemistry and thermal maturation of organic matter in coal and shale is addressed. These investigations demonstrate that the employment of high-resolution micro-FTIR imaging enables visualization and mapping of the distributions of organic matter and minerals on a micrometer scale in geological samples, and promotes an advanced understanding of heterogeneity of organic rich coal and shale. Additionally, micro-FTIR is particularly suitable for in situ, non-destructive characterization of minute microfossils, small fluid and melt inclusions within crystals, and volatiles in glasses and minerals. This technique can also assist in the chemotaxonomic classification of macrofossils such as plant fossils. These features, barely accessible with other analytical techniques, may provide fundamental information on paleoclimate, depositional environment, and the evolution of geological (e.g., volcanic and magmatic) systems.

58 GEOSCIENCES↗

Geometric Representations for Discrete Fourier Transforms

Simple geometric representations show symmetry and periodicity of discrete Fourier transforms (DFT's). Help in visualizing requirements for storing and manipulating transform value in computations. Representations useful in any number of dimensions, but particularly in one-, two-, and three-dimensional cases often encountered in practice.

Cambell, C. W.↗

Fourier Transform Infrared Spectroscopy of CF4 on the GEC Reference Cell

Fourier Transform Infrared Spectroscopy (FTIR) has been used to characterize inductively coupled CF4 plasmas in a GEC Reference Cell in-situ In examining these FTIR spectra, several assumptions and approximations of FTIR analysis are addressed. This includes the density dependence of cross-sections, non-linear effects in the addition of overlapping bands and the effect of spatial variations in density and temperature, This analysis demonstrates that temperatures extracted from MR spectra may provide a poor estimate of the true neutral plasma temperature. The FTIR spectra are dominated by unreacted CF, accounting for 40-60% of the gas products. The amount of CF4 consumption is found to have a marked dependence on power, and is nearly independent of pressure in the range of 10-50 mtorr. Small amounts of C2F6 are observed at low power. Also observed are etching products from the quartz window SiF4 COF2 and CO which occur in approximately equal ratios and together account for less than 10% of the gas. The concentrations of these species are nearly independent of pressure. CFx radicals are below the detection limit of this apparatus (approx. 1012/cc).

Rao, M. V. V. S.↗

A Synthetic Quadrature Phase Detector/Demodulator for Fourier Transform Transform Spectrometers

A method is developed to demodulate (velocity correct) Fourier transform spectrometer (FTS) data that is taken with an analog to digital converter that digitizes equally spaced in time. This method makes it possible to use simple low cost, high resolution audio digitizers to record high quality data without the need for an event timer or quadrature laser hardware, and makes it possible to use a metrology laser of any wavelength. The reduced parts count and simplicity implementation makes it an attractive alternative in space based applications when compared to previous methods such as the Brault algorithm.

Campbell, Joel↗

On integral and finite Fourier transforms of continuous q-Hermite polynomials

We give an overview of the remarkably simple transformation properties of the continuous q-Hermite polynomials H{sub n}(x vertical bar q) of Rogers with respect to the classical Fourier integral transform. The behavior of the q-Hermite polynomials under the finite Fourier transform and an explicit form of the q-extended eigenfunctions of the finite Fourier transform, defined in terms of these polynomials, are also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of fast Fourier transforms to the direct solution of a class of two-dimensional separable elliptic equations on the sphere

An efficient, direct, second-order solver for the discrete solution of a class of two-dimensional separable elliptic equations on the sphere (which generally arise in implicit and semi-implicit atmospheric models) is presented. The method involves a Fourier transformation in longitude and a direct solution of the resulting coupled second-order finite-difference equations in latitude. The solver is made efficient by vectorizing over longitudinal wave-number and by using a vectorized fast Fourier transform routine. It is evaluated using a prescribed solution method and compared with a multigrid solver and the standard direct solver from FISHPAK.

Moorthi, Shrinivas↗

Techniques for Handling Channeling in High Resolution Fourier Transform Spectra Recorded with Synchrotron Sources

Seven different techniques in dealing the problem of channel spectra in Fourier transform Spectroscopy utilizing synchrotron source were examined and compared. Five of these techniques deal with the artifacts (spikes) in the recorded interferogram which in turn result in channel spectra within the spectral domain. Such interferogram editing method include replacing these spikes with zeros, straight line, fitted polynomial curve, rescaled spike and spike reduced with Gauss Function. Another two techniques try to target this issue in the spectral domain instead by either generating a synthetic background simulating the channels or measuring the channels parameters (amplitude, spacing and phase) to use in the spectral fitting program. Results showed spectral domain techniques produces higher quality results in terms of signal to noise and fitting residual. The effect of each method on the line parameters such as position, intensity are air broadening are also measured and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A gain and bandwidth enhanced transimpedance preamplifier for Fourier-transform ion cyclotron resonance mass spectrometry

The nature of the ion signal from a 12-T Fourier-transform ion cyclotron resonance mass spectrometer and the electronic noise were studied to further understand the electronic detection limit. At minimal cost, a new transimpedance preamplifier was designed, computer simulated, built, and tested. The preamplifier design pushes the electronic signal-to-noise performance at room temperature to the limit, because of its enhanced tolerance of the capacitance of the detection device, lower intrinsic noise, and larger flat mid-band gain (input current noise spectral density of around 1 pA/{radical}(Hz) when the transimpedance is about 85 dB{Omega}). The designed preamplifier has a bandwidth of {approx}3 kHz to 10 MHz, which corresponds to the mass-to-charge ratio, m/z, of approximately 18 to 61 k at 12 T. The transimpedance and the bandwidth can be easily adjusted by changing the value of passive components. The feedback limitation of the circuit is discussed. With the maximum possible transimpedance of 5.3 M{Omega} when using an 0402 surface mount resistor, the preamplifier was estimated to be able to detect {approx}110 charges in a single scan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FOURIER TRANSFORM EMISSION SPECTROSCOPY OF THE A {sup 2}{Pi}-X {sup 2}{Sigma}{sup +} (RED) SYSTEM OF {sup 13}C{sup 14}N

Emission spectra of the A {sup 2{Pi}}-X {sup 2}{Sigma}{sup +} transition (red system) of {sup 13}C{sup 14}N have been measured in the 4000-15,000 cm{sup -1} region using the Fourier transform spectrometer associated with the McMath-Pierce Solar Telescope of the National Solar Observatory. The {sup 13}C{sup 14}N free radical was produced in microwave discharge of a mixture of {sup 13}CH{sub 4} and {sup 14}N{sub 2}. Rotational analysis of 22 vibrational bands involving vibrational levels up to v' = 8 and v'' = 5 of the excited and ground states has been obtained and much improved spectroscopic constants have been determined. An experimental line list and calculated term values are provided. The results of the present analysis are useful for the identification of {sup 13}C{sup 14}N lines in late-type stars in the red and near-infrared spectral regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Absolute atomic oxygen and nitrogen densities in radio-frequency driven atmospheric pressure cold plasmas: Synchrotron vacuum ultra-violet high-resolution Fourier-transform absorption measurements

Reactive atomic species play a key role in emerging cold atmospheric pressure plasma applications, in particular, in plasma medicine. Absolute densities of atomic oxygen and atomic nitrogen were measured in a radio-frequency driven non-equilibrium plasma operated at atmospheric pressure using vacuum ultra-violet (VUV) absorption spectroscopy. The experiment was conducted on the DESIRS synchrotron beamline using a unique VUV Fourier-transform spectrometer. Measurements were carried out in plasmas operated in helium with air-like N{sub 2}/O{sub 2} (4:1) admixtures. A maximum in the O-atom concentration of (9.1 {+-} 0.7) Multiplication-Sign 10{sup 20} m{sup -3} was found at admixtures of 0.35 vol. %, while the N-atom concentration exhibits a maximum of (5.7 {+-} 0.4) Multiplication-Sign 10{sup 19} m{sup -3} at 0.1 vol. %.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray Rietveld analysis and Fourier transform infrared spectra of the solid solutions [Eu{sub 2-x}M{sub x}][Sn{sub 2-x}M{sub x}]O{sub 7-3x/2} (M = Mg or Zn)

Two series of mixed oxides with formula [Eu{sub 2-x}M{sub x}][Sn{sub 2-x}M{sub x}]O{sub 7-3x/2} (M = Mg or Zn) have been synthesized. The study by X-ray diffraction and Fourier transform infrared spectroscopy shows that the solids obtained are new non-stoichiometric solid solutions with the pyrochlore type structure. For both series a decrease of the cell parameter is observed when the degree of substitution, x, increases. The structural refinements (X-ray studies) were achieved in the space group Fd-3m, no. 227 (origin at center -3m) by using the Fullprof software. The Rietveld refinements show that the divalent cations M{sup 2+} (Mg{sup 2+}, Zn{sup 2+}) substitute isomorphically for Eu{sup 3+} and Sn{sup 4+} ions producing vacancies in the anionic sublattice.

36 MATERIALS SCIENCE↗

Fourier transform infrared identification of the ν{sub 5}(σ{sub u}) fundamental of SiC{sub 5}Si

The Fourier transform infrared spectrum of SiC{sub 5}Si was observed by trapping the vapor from the Nd:YAG laser ablation of sintered Si/C rods in solid Ar at ∼20 K. Measurements of {sup 13}C and {sup 29,30}Si isotopic shifts have enabled the identification of the ν{sub 5}(σ{sub u}) vibrational fundamental of the linear isomer of SiC{sub 5}Si at 1590.8 ± 0.2 cm{sup −1}. The results are in excellent agreement with the predictions of density functional theory calculations at the B3LYP/cc-pVDZ level. A second fundamental, ν{sub 4}(σ{sub u}), can only be tentatively identified at 2021.0 cm{sup −1}, because its isotopic shifts are overlapped by absorptions from other species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗