Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Focuses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Stationary self-focusing of intense laser beam in cold quantum plasma using ramp density profile

By using a transient density profile, we have demonstrated stationary self-focusing of an electromagnetic Gaussian beam in cold quantum plasma. The paper is devoted to the prospects of using upward increasing ramp density profile of an inhomogeneous nonlinear medium with quantum effects in self-focusing mechanism of high intense laser beam. We have found that the upward ramp density profile in addition to quantum effects causes much higher oscillation and better focusing of laser beam in cold quantum plasma in comparison to that in the classical relativistic case. Our computational results reveal the importance and influence of formation of electron density profiles in enhancing laser self-focusing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Self-focusing of circularly polarized laser pulse in the hot magnetized plasma in the quasi-neutral limit

In this paper the problem of self-focusing of an intense laser beam in the hot magnetized plasma is studied. Using a relativistic two-fluid model, the propagation of intense circularly polarized laser beam along the external magnetic field is considered. The nonlinear equation describing the interaction of laser beam with magnetized hot plasma in the quasi-neutral approximation is derived. Expanding the nonlinear terms of current density and saving only the parabolic nonlinear terms, we investigated the self-focusing phenomenon for right- and left-hand circularly polarized laser beam. The evolution of laser beam spot size with Gaussian profile for both polarizations is considered and the effect of the temperature and external magnetic field on the self-focusing quality is studied. It is shown that for the right-hand polarization, the effect of temperature and external magnetic field on the self-focusing property is more considerable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new adaptive light beam focusing principle for scanning light stimulation systems

In this article a novel principle to achieve optimal focusing conditions or rather the smallest possible beam diameter for scanning light stimulation systems is presented. It is based on the following methodology: First, a reference point on a camera sensor is introduced where optimal focusing conditions are adjusted and the distance between the light focusing optic and the reference point is determined using a laser displacement sensor. In a second step, this displacement sensor is used to map the topography of the sample under investigation. Finally, the actual measurement is conducted, using optimal focusing conditions in each measurement point at the sample surface, that are determined by the height difference between camera sensor and the sample topography. This principle is independent of the measurement values, the optical or electrical properties of the sample, the used light source, or the selected wavelength. Furthermore, the samples can be tilted, rough, bent, or of different surface materials. In the following the principle is implemented using an optical beam induced current system, but basically it can be applied to any other scanning light stimulation system. Measurements to demonstrate its operation are shown, using a polycrystalline silicon solar cell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Re-appraisal and extension of the Gratton-Vargas two-dimensional analytical snowplow model of plasma focus evolution in the context of contemporary research

Recent resurgence of interest in applications of dense plasma focus and doubts about the conventional view of dense plasma focus as a purely irrotational compressive flow have re-opened questions concerning device optimization. In this context, this paper re-appraises and extends the analytical snowplow model of plasma focus sheath evolution developed by F. Gratton and J. M. Vargas [Energy Storage, Compression and Switching, edited by V. Nardi, H. Sahlin, and W. H. Bostick (Plenum, New York, 1983), Vol. 2, p. 353)] and shows its relevance to contemporary research. The Gratton-Vargas (GV) model enables construction of a special orthogonal coordinate system in which the plasma flow problem can be simplified and a model of sheath structure can be formulated. The Lawrenceville Plasma Physics (LPP) plasma focus facility, which reports neutron yield better than global scaling law, is shown to be operating closer to an optimum operating point of the GV model as compared with PF-1000.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimally focused cold atom systems obtained using density-density correlations

Resonant absorption imaging is a common technique for detecting the two-dimensional column density of ultracold atom systems. In many cases, the system's thickness along the imaging direction greatly exceeds the imaging system's depth of field, making the identification of the optimally focused configuration difficult. Here we describe a systematic technique for bringing Bose-Einstein condensates (BEC) and other cold-atom systems into an optimal focus even when the ratio of the thickness to the depth of field is large: a factor of 8 in this demonstration with a BEC. This technique relies on defocus-induced artifacts in the Fourier-transformed density-density correlation function (the power spectral density, PSD). The spatial frequency at which these artifacts first appear in the PSD is maximized on focus; the focusing process therefore both identifies and maximizes the range of spatial frequencies over which the PSD is uncontaminated by finite-thickness effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatiotemporal focusing dynamics in plasmas at X-ray wavelength

Using a finite curvature beam, we investigate here the spatiotemporal focusing dynamics of a laser pulse in plasmas at X-ray wavelength. We trace the dependence of curvature parameter on the focusing of laser pulse and recognize that the self-focusing in plasma is more intense for the X-ray laser pulse with curved wavefront than with flat wavefront. The simulation results demonstrate that spatiotemporal focusing dynamics in plasmas can be controlled with the appropriate choice of beam-plasma parameters to explore the high intensity effects in X-ray regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stimulated Brillouin scattering reduction induced by self-focusing for a single laser speckle interacting with an expanding plasma

The origin of the low level of stimulated Brillouin scattering (SBS) observed in laser-plasma experiments carried out with a single laser speckle is investigated by means of three-dimensional simulations and modeling in the limit when the laser beam power P is well above the critical power for ponderomotive self-focusing We find that the order of magnitude of the time averaged reflectivities, together with the temporal and spatial SBS localization observed in our simulations, are correctly reproduced by our modeling. It is observed that, after a short transient stage, SBS reaches a significant level only (i) as long as the incident laser pulse is increasing in amplitude and (ii) in a single self-focused speckle located in the low-density front part of the plasma. In order to describe self-focusing in an inhomogeneous expanding plasma, we have derived a new Lagrangian density describing this process. Using then a variational approach, our model reproduces the position and the peak intensity of the self-focusing hot spot in the front part of the plasma density profile as well as the local density depletion in this hot spot. The knowledge of these parameters then makes it possible to estimate the spatial amplification of SBS as a function of the laser beam power and consequently to explain the experimentally observed SBS reflectivity, considerably reduced with respect to standard theory in the regime of large laser beam power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laboratory-based micro-X-ray fluorescence setup using a von Hamos crystal spectrometer and a focused beam X-ray tube

The high-resolution von Hamos bent crystal spectrometer of the University of Fribourg was upgraded with a focused X-ray beam source with the aim of performing micro-sized X-ray fluorescence (XRF) measurements in the laboratory. The focused X-ray beam source integrates a collimating optics mounted on a low-power micro-spot X-ray tube and a focusing polycapillary half-lens placed in front of the sample. The performances of the setup were probed in terms of spatial and energy resolution. In particular, the fluorescence intensity and energy resolution of the von Hamos spectrometer equipped with the novel micro-focused X-ray source and a standard high-power water-cooled X-ray tube were compared. The XRF analysis capability of the new setup was assessed by measuring the dopant distribution within the core of Er-doped SiO{sub 2} optical fibers.

36 MATERIALS SCIENCE↗

Effect of polarization and focusing on laser pulse driven auto-resonant particle acceleration

The effect of laser polarization and focusing is theoretically studied on the final energy gain of a particle in the Auto-resonant acceleration scheme using a finite duration laser pulse with Gaussian shaped temporal envelope. The exact expressions for dynamical variables viz. position, momentum, and energy are obtained by analytically solving the relativistic equation of motion describing particle dynamics in the combined field of an elliptically polarized finite duration pulse and homogeneous static axial magnetic field. From the solutions, it is shown that for a given set of laser parameters viz. intensity and pulse length along with static magnetic field, the energy gain by a positively charged particle is maximum for a right circularly polarized laser pulse. Further, a new scheme is proposed for particle acceleration by subjecting it to the combined field of a focused finite duration laser pulse and static axial magnetic field. In this scheme, the particle is initially accelerated by the focused laser field, which drives the non-resonant particle to second stage of acceleration by cyclotron Auto-resonance. The new scheme is found to be efficient over two individual schemes, i.e., auto-resonant acceleration and direct acceleration by focused laser field, as significant particle acceleration can be achieved at one order lesser values of static axial magnetic field and laser intensity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microsphere-chain waveguides: Focusing and transport properties

It is shown that the focusing properties of polystyrene microsphere-chain waveguides (MCWs) formed by sufficiently large spheres (D ≥ 20λ, where D is the sphere diameter and λ is the wavelength of light) scale with the sphere diameter as predicted by geometrical optics. However, this scaling behavior does not hold for mesoscale MCWs with D ≤ 10λ resulting in a periodical focusing with gradually reducing beam waists and in extremely small propagation losses. The observed effects are related to properties of nanojet-induced and periodically focused modes in such structures. The results can be used for developing focusing microprobes, laser scalpels, and polarization filters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Focusing of intense and divergent ion beams in a magnetic mass analyzer

A magnetic mass analyzer is used to determine the beam composition of a vacuum arc ion source. In the analyzer, we used the concentric multi-ring electrodes to focus the intense and divergent ion beams. We describe the principle, design, and the test results of the focusing device. The diameter of the beam profile is less than 20 mm when the accelerating voltage is 30 kV and the focusing voltage is about 2.0 kV. The focusing device has been successfully used in the magnetic mass analyzer to separate Ti{sup +}, Ti{sup 2+}, and Ti{sup 3+}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Focusing electrode and coaxial reflector used for reducing the guiding magnetic field of the Ku-band foilless transit-time oscillator

Based on the theoretical analysis of the intense relativistic electron beam propagation in the coaxial drift-tube, a focusing electrode and a coaxial reflector is proposed to lessen the demand of the coaxial Ku-band foilless transit-time oscillator (TTO) for the guiding magnetic field. Moreover, a Ku-band TTO with the focusing electrode and the coaxial reflector is designed and studied by particle in cell simulation. When the diode voltage is 390 kV, the beam current 7.8 kA, and the guiding magnetic field is only 0.3 T, the device can output 820 MW microwave pulse at 14.25 GHz by means of the simulation. However, for the device without them, the output power is only 320 MW. The primary experiments are also carried out. When the guiding magnetic field is 0.3 T, the output power of the device with the focusing electrode and the coaxial reflector is double that of the one without them. The simulation and experimental results prove that the focusing electrode and the coaxial reflector are effective on reducing the guiding magnetic field of the device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Figure correction of a metallic ellipsoidal neutron focusing mirror

An increasing number of neutron focusing mirrors is being adopted in neutron scattering experiments in order to provide high fluxes at sample positions, reduce measurement time, and/or increase statistical reliability. To realize a small focusing spot and high beam intensity, mirrors with both high form accuracy and low surface roughness are required. To achieve this, we propose a new figure correction technique to fabricate a two-dimensional neutron focusing mirror made with electroless nickel-phosphorus (NiP) by effectively combining ultraprecision shaper cutting and fine polishing. An arc envelope shaper cutting method is introduced to generate high form accuracy, while a fine polishing method, in which the material is removed effectively without losing profile accuracy, is developed to reduce the surface roughness of the mirror. High form accuracy in the minor-axis and the major-axis is obtained through tool profile error compensation and corrective polishing, respectively, and low surface roughness is acquired under a low polishing load. As a result, an ellipsoidal neutron focusing mirror is successfully fabricated with high form accuracy of 0.5 μm peak-to-valley and low surface roughness of 0.2 nm root-mean-square.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fine structure of modal focusing effect in a three dimensional plasma-sheath-lens formed by disk electrodes

Modal and discrete focusing effects associated with three-dimensional plasma-sheath-lenses show promising potential for applications in ion beam extraction, mass spectrometry, plasma diagnostics and for basic studies of plasma sheath. The ion focusing properties can be adjusted by controlling the geometrical structure of the plasma-sheath-lens and plasma parameters. The positive and negative ion kinetics within the plasma-sheath-lens are investigated both experimentally and theoretically and a modal focusing ring is identified on the surface of disk electrodes. The focusing ring is very sensitive to the sheath thickness and can be used to monitor very small changes in plasma parameters. Three dimensional simulations are found to be in very good agreement with experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A collimated focused ultrasound beam of high acoustic transmission and minimum diffraction achieved by using a lens with subwavelength structures

An acoustic focusing lens incorporated with periodically aligned subwavelength grooves corrugated on its spherical surface has been developed. It is demonstrated theoretically and experimentally that acoustic focusing achieved by using the lens can suppress the relative side-lobe amplitudes, enhance the focal gain, and minimize the shifting of the focus. Use of the lens coupled with a planar ultrasound transducer can generate an ultrasound beam with enhanced acoustic transmission and collimation effect, which offers the capability of improving the safety, efficiency, and accuracy of targeted surgery implemented by high intensity focused ultrasound.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Upgrading multilayer zone plate technology for hard x-ray focusing

Multilayer zone plate (MZP) technology for hard X-ray focusing was upgraded and its focusing performance was evaluated using 20-keV X-rays at the synchrotron beamline (BL24XU) of SPring-8. The MZP consists of MoSi{sub 2} and Si layers alternately deposited on a glass fiber by magnetron sputtering so that all zone boundaries satisfy the Fresnel zone configuration. The focused beam was evaluated using knife-edge scanning in which the measured intensity distribution is identical to the line spread function (LSF) in the focal plane. The focused beamsize of about 30 nm was estimated by oscillation peaks observed in the measured LSF according to Rayleigh’s criterion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broadband reflective metasurface for focusing underwater ultrasonic waves with linearly tunable focal length

We report a metasurface for focusing reflected ultrasonic waves over a wide frequency band of 0.45–0.55 MHz. The broadband focusing effect of the reflective metasurface is studied numerically and then confirmed experimentally using near-field scanning techniques. The focusing mechanism can be attributed to the hyperboloidal reflection phase profile imposed by different depths of concentric grooves on the metasurface. In particular, the focal lengths of the reflective metasurface are extracted from simulations and experiments, and both exhibit good linear dependence on frequency over the considered frequency band. The proposed broadband reflective metasurface with tunable focal length has potential applications in the broad field of ultrasonics, such as ultrasonic tomographic imaging, high intensity focused ultrasound treatment, etc.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of high-order harmonic focusing system based on ellipsoidal mirror

We have developed a focusing system for extreme ultraviolet light produced by high-order harmonic generation. An ellipsoidal mirror with a precise surface shape was fabricated and installed into the focusing system. A rigid mirror manipulator and a beam profiler were employed to perform precise and stable mirror alignment. As a demonstration of the focusing performance, high-order harmonics in the wavelength range of 13.5–19.5 nm were successfully focused into a 2.4 × 2.3 μm{sup 2} spot.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗