Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUOROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Percutaneous Intraluminal Recanalization of Long, Chronic Superficial Femoral and Popliteal Occlusions Using the Frontrunner XP CTO Device: A Single-Center Experience

The purpose of this study was to examine the safety and efficacy of the Frontrunner XP CTO (chronic total occlusion) Catheter (Cordis) for recanalization of long femoropopliteal artery occlusions. A Frontrunner catheter was used to treat 26 CTOs in SFA after guidewire failure (68.3 {+-} 8.8 years). Sixty-seven percent of patients had severe claudication. Critical lower limb ischemia with rest pain or minor tissue loss was present in three and eight patients, respectively. All the lesions were considered complex (TASC B, C, and D); 68% of the lesions were heavily calcified. The mean lesion length was 17.6 cm (range, 10-42 cm). The initial attempt to cross the occlusion with the CTO guidewire V18 was unsuccessful in 26 of 76 limbs (34.26%). A secondary attempt using the Frontrunner catheter (crossover approach, 27%; antegrade, 73%) performed in all 26 failed cases was successful in 17 limbs (65.38%), increasing the technical success rate to 88.12%. The main reasons for failure with the Frontrunner were inability to cross the lesion due to heavy calcification (six of nine) and inability to re-enter the true lumen after subintimal passage of the occluded segment (three of nine). The mean fluoroscopy time was 22.9 min. Minor complications included one distal extension of the dissection with involvement of the first popliteal segment and one perforation in the occluded segment. No major complications were seen. In conclusion, recanalization with the Frontrunner CTO catheter is a simple and safe method with a high technical success rate in the endovascular treatment of long superficial femoral artery occlusions and should be an alternative method after guidewire failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Screw Placement and Osteoplasty Under Computed Tomographic-Fluoroscopic Guidance in a Case of Advanced Metastatic Destruction of the Iliosacral Joint

We present a case of combined surgical screw placement and osteoplasty guided by computed tomography-fluoroscopy (CTF) in a 68-year-old man with unilateral osteolytic destruction and a pathological fracture of the iliosacral joint due to a metastasis from renal cell carcinoma. The patient experienced intractable lower back pain that was refractory to analgesia. After transarterial particle and coil embolization of the tumor-feeding vessels in the angiography unit, the procedure was performed under general anesthesia by an interdisciplinary team of interventional radiologists and trauma surgeons. Under intermittent single-shot CTF, two K wires were inserted into the left iliosacral joint from a lateral transiliac approach at the S1 level followed by two self-tapping surgical screws. Continuous CTF was used for monitoring of the subsequent polymethylmethacrylate injection through two vertebroplasty cannulas for further stabilization of the screw threads within the osteolytic sacral ala. Both the screw placement and cement injection were successful, with no complications occurring during or after the procedure. With additional nonsteroidal anti-inflammatory and opioid medication, the patient reported a marked decrease in his lower back pain and was able to move independently again at the 3-month follow-up assessment. In our patient with intolerable back pain due to tumor destruction and consequent pathological fracture of the iliosacral joint, CTF-guided iliosacral screw placement combined with osteoplasty was successful with respect to joint stabilization and a reduction in the need for analgesic therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Transhepatic Endoscopic Holmium Laser Lithotripsy for Intrahepatic and Choledochal Biliary Stones

Purpose: To report our approach for treating complicated biliary calculi by percutaneous transhepatic endoscopic biliary holmium laser lithotripsy (PTBL). Patients and Methods: Twenty-two symptomatic patients (11 men and 11 women, age range 51 to 88 years) with intrahepatic or common bile duct calculi underwent PTBL. Nine patients had undergone previous gastrectomy and small-bowel anastomosis, thus precluding endoscopic retrograde cholangiopancreatography. In the other 13 patients, stone removal attempts by ERCP failed due to failed access or very large calculi. We used a 7.5F flexible ureteroscope and a 200-{mu}m holmium laser fiber by way of a percutaneous transhepatic tract, with graded fluoroscopy, to fragment the calculi with direct vision. Balloon dilatation was added when a stricture was seen. The procedure was performed with the patient under general anaesthesia. A biliary drainage tube was left at the end of the procedure. Results: All stones were completely fragmented and flushed into the small bowel under direct vision except for one patient in whom the procedure was aborted. In 18 patients, 1 session sufficed, and in 3 patients, 2 sessions were needed. In 7 patients, balloon dilatation was performed for benign stricture after Whipple operation (n = 3), for choledochalenteric anastomosis (n = 3), and for recurrent cholangitis (n = 1). Adjunctive 'balloon push' (n = 4) and 'rendezvous' (n = 1) procedures were needed to completely clean the biliary tree. None of these patients needed surgery. Conclusion: Complicated or large biliary calculi can be treated successfully using PTBL. We suggest that this approach should become the first choice of treatment before laparoscopic or open surgery is considered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Transosseous Embolization of Internal Iliac Artery Aneurysm Type II Endoleak: Report of Two Cases

This report describes two cases of successful treatment of an internal iliac artery aneurysm (IIAA) type II endoleak utilizing a percutaneous transosseous access that could not be treated using an endovascular or standard percutaneous approach. A direct percutaneous approach through bone was chosen to avoid vital structures and the surrounding bowel. The procedure was successful and required minimal fluoroscopy time compared with other treatment options. We believe this procedure is an alternative to some of the more complex and technically challenging means of treating this lesion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computed Tomography-Guided Access to the Cisterna Chyli: Introduction of a Technique for Direct Lymphangiography to Evaluate and Treat Chylothorax

The purpose of this report is to introduce a technique of direct lymphangiography to enable chylothorax treatment. Using a hybrid computed tomography (CT) and fluoroscopy imaging system, a 21-gauge needle was placed under CT guidance into the cisterna chyli to allow contrast lymphangiography and CT lymphangiography in two patients with presumed postoperative chylothorax. Water-soluble contrast media injection demonstrated the thoracic duct anatomy in both patients. Further successful needle disruption of the cisterna chyli was performed in one patient to interrupt lymph flow and stop the chylous leak, with subsequent resolution of the chylothorax.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pull-Through Technique for Recanalization of Occluded Portosystemic Shunts (TIPS): Technical Note and Review of the Literature

Transjugular intrahepatic portosystemic shunt (TIPS) dysfunction is an important problem after creation of shunts. Most commonly, TIPS recanalization is performed via the jugular vein approach. Occasionally it is difficult to cross the occlusion. We describe a hybrid technique for TIPS revision via a direct transhepatic access combined with a transjugular approach. In two cases, bare metal stents or polytetrafluoroethylene (PTFE)-covered stent grafts had been placed in TIPS tract previously, and they were completely obstructed. The tracts were inaccessible via the jugular vein route alone. In each case, after fluoroscopy or computed tomography-guided transhepatic puncture of the stented segment of the TIPS, a wire was threaded through the shunt and snared into the right jugular vein. The TIPS was revised by balloon angioplasty and additional in-stent placement of PTFE-covered stent grafts. The patients were discharged without any complications. Doppler sonography 6 weeks after TIPS revision confirmed patency in the TIPS tract and the disappearance of ascites. We conclude that this technique is feasible and useful, even in patients with previous PTFE-covered stent graft placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Iatrogenic Aortic Dissection During Left Subclavian Artery Stenting: Immediate Detection by Calcium Sign Under Fluoroscope

Calcified aorta with acute iatrogenic aortic dissection is a potential but rarely reported complication of subclavian or innominate artery intervention. We report a patient who developed aortic dissection during stenting for left subclavian artery. A newly developed 'calcium sign,' signifying displacement of the intimal calcification from the outer soft-tissue margin and which is traditionally recognized on chest radiograph, was detected by real-time fluoroscopy and served as the diagnostic clue. Type B aortic dissection was further confirmed by chest computed tomography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optease Vena Cava Filter Optimal Indwelling Time and Retrievability

The purpose of this study was to assess the indwelling time and retrievability of the Optease IVC filter. Between 2002 and 2009, a total of 811 Optease filters were inserted: 382 for prophylaxis in multitrauma patients and 429 for patients with venous thromboembolic (VTE) disease. In 139 patients [97 men and 42 women; mean age, 36 (range, 17-82) years], filter retrieval was attempted. They were divided into two groups to compare change in retrieval policy during the years: group A, 60 patients with filter retrievals performed before December 31 2006; and group B, 79 patients with filter retrievals from January 2007 to October 2009. A total of 128 filters were successfully removed (57 in group A, and 71 in group B). The mean filter indwelling time in the study group was 25 (range, 3-122) days. In group A the mean indwelling time was 18 (range, 7-55) days and in group B 31 days (range, 8-122). There were 11 retrieval failures: 4 for inability to engage the filter hook and 7 for inability to sheathe the filter due to intimal overgrowth. The mean indwelling time of group A retrieval failures was 16 (range, 15-18) days and in group B 54 (range, 17-122) days. Mean fluoroscopy time for successful retrieval was 3.5 (range, 1-16.6) min and for retrieval failures 25.2 (range, 7.2-62) min. Attempts to retrieve the Optease filter can be performed up to 60 days, but more failures will be encountered with this approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Image-Guided Management of a Uterine Arteriovenous Malformation

The investigators present a novel image-guided embolization, not previously described, of a uterine arteriovenous malformation (AVM) resistant to endovascular management. The uterus was exposed surgically, and Histoacryl (Braun, Fulda, Germany) was injected directly into the nidus using ultrasound guidance and fluoroscopy. The patient had a successful full-term pregnancy after this procedure. This technique may be a useful alternative management strategy in patients with uterine AVM who fail traditional endovascular embolization and who still desire fertility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Staff Radiation Doses in a Real-Time Display Inside the Angiography Room

MethodsThe evaluation of a new occupational Dose Aware System (DAS) showing staff radiation doses in real time has been carried out in several angiography rooms in our hospital. The system uses electronic solid-state detectors with high-capacity memory storage. Every second, it archives the dose and dose rate measured and is wirelessly linked to a base-station screen mounted close to the diagnostic monitors. An easy transfer of the values to a data sheet permits further analysis of the scatter dose profile measured during the procedure, compares it with patient doses, and seeks to find the most effective actions to reduce operator exposure to radiation.ResultsThe cumulative occupational doses measured per procedure (shoulder-over lead apron) ranged from 0.6 to 350 {mu}Sv when the ceiling-suspended screen was used, and DSA (Digital Subtraction Acquisition) runs were acquired while the personnel left the angiography room. When the suspended screen was not used and radiologists remained inside the angiography room during DSA acquisitions, the dose rates registered at the operator's position reached up to 1-5 mSv/h during fluoroscopy and 12-235 mSv/h during DSA acquisitions. In such case, the cumulative scatter dose could be more than 3 mSv per procedure.ConclusionReal-time display of doses to staff members warns interventionists whenever the scatter dose rates are too high or the radiation protection tools are not being properly used, providing an opportunity to improve personal protection accordingly.

61 RADIATION PROTECTION AND DOSIMETRY↗

Standards of Practice: Quality Assurance Guidelines for Percutaneous Treatments of Intervertebral Discs

Percutaneous treatments are used in the therapy of small- to medium-sized hernias of intervertebral discs to reduce the intradiscal pressure in the nucleus and theoretically create space for the herniated fragment to implode inward, thus reducing pain and improving mobility and quality of life. These techniques involve the percutaneous removal of the nucleus pulposus by using a variety of chemical, thermal, or mechanical techniques and consist of removal of all or part of nucleus pulposus to induce more rapid healing of the abnormal lumbar disc. These guidelines are written to be used in quality improvement programs for assessing fluoroscopy- and/or computed tomography-guided percutaneous intervertebral disc ablative techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Safety and Effectiveness of the 'OptEase' Vena Cava Filter

Purpose: To assess the long-term safety and effectiveness of the OptEase inferior vena cava (IVC) filter. Materials and Methods: In this Institutional Review Board-approved, retrospective study, we reviewed data of 71 patients who received an OptEase filter at our institution from 2002 to 2007. Thirty-nine (55%) patients had symptoms of venous thromboembolism before filter placement. The indications for filter included contraindication to anticoagulation in 31 (44%) patients, prophylaxis against pulmonary embolism (PE) in 29 (41%) patients, and failure of anticoagulation in 11 (15%) patients. Procedure-related complications, such as symptomatic post-filter PE, deep venous thrombosis (DVT), IVC occlusion, and incidental imaging-evident filter-related complications, were recorded. Safety was assessed by the occurrence of filter-related complications during placement and follow-up. Effectiveness was assessed by the occurrence of post-filter PE. Results: Sixty-five (92%) filters were placed under fluoroscopy, and 6 (8%) were placed using intravascular ultrasound guidance. Seventy (99%) filters were placed successfully. Seven (10%) filters were placed in the suprarenal cava. Retrieval was attempted in 14 (20%) patients, and 12 filters were successfully retrieved. Clinical follow-up was available for 20 {+-} 21 months. Symptoms of postfilter PE and DVT occurred in 15% (n = 11) and 10% (n = 7) patients, respectively. None of these patients had computed tomography (CT)-proven PE, and only one had ultrasound-proven new DVT. One patient had symptomatic IVC occlusion. Follow-up abdominal CT in 20 patients showed thrombus in the filter in two of them. There were no instances of filter migration, filter tilt, or caval wall penetration. Conclusion: The OptEase filter appears to have an acceptable long-term safety profile. The filter was effective against PE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Discomanometry: Correlation of Intradiscal Pressure Values to Pain Reduction in Patients With Intervertebral Disc Herniation Treated With Percutaneous, Minimally Invasive, Image-Guided Techniques

Purpose: To illustrate quantitative discomanometry's (QD) diagnostic efficacy and predictive value in discogenic-pain evaluation in a prospective study correlating intradiscal pressure values with pain reduction after percutaneous image-guided technique (i.e., percutaneous decompression, PD). Materials and Methods: During the last 3 years, 36 patients [21 male and 15 female (mean age 36 {+-} 5.8 years)] with intervertebral disc hernia underwent QD before PD. Under absolute sterilization and fluoroscopy, a mixture of contrast medium and normal saline (3:1 ratio) was injected. A discmonitor performed a constant rate injection and recorded pressure and volume values, thus producing the relative pressure-volume curve. PD was then performed. Pain reduction and improved mobility were recorded at 3, 12, and 24 months after PD using clinical evaluation and a numeric visual scale (NVS; 0 to 10 units). Results: Mean pain values of 7.5 {+-} 1.9 (range 4 to 8) NVS units were recorded before PD; these decreased to 2.9 {+-} 2.44 at 3 months, 1.0 {+-} 1.9 at 12 months, and 1.0 {+-} 1.9 NVS units at 24 months after PD. Recorded correlations (pressure, volume, significant pain-reduction values) with bilateral statistical significance included a maximum injected volume of 2.4 ml (p = 0.045), P{sub o} < 14 psi [initial pressure required to inject 0.1 ml of the mixture inside the disc (p = 0.05)], P{sub max} {<=} 65 psi [greatest pressure value on the curve (p = 0.018)], and P{sub max} - P{sub o} {<=} 47 psi (p = 0.038). Patients meeting these pressure or volume cut-off points, either independently or as a total, had significant pain reduction (>4 NVS units) after PD. No complications were noted. Conclusions: QD is an efficient technique that may have predictive value for discogenic pain evaluation. It might serve as a useful tool for patient selection for intervertebral disc therapies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transsinusoidal Portal Vein Embolization with Ethylene Vinyl Alcohol Copolymer (Onyx): A Feasibility Study in Pigs

Purpose: Portal vein embolization is performed to increase the future liver remnant before liver surgery in patients with liver malignancies. This study assesses the feasibility of a transsinusoidal approach for portal vein embolization (PVE) with the ethylene vinyl alcohol copolymer, Onyx. Methods: Indirect portography through contrast injection in the cranial mesenteric artery was performed in eight healthy pigs. Onyx was slowly injected through a microcatheter from a wedged position in the hepatic vein and advanced through the liver lobules into the portal system. The progression of Onyx was followed under fluoroscopy, and the extent of embolization was monitored by indirect portography. The pigs were euthanized immediately (n = 2), at 7 days (n = 4), or at 21 days postprocedure (n = 2). All pigs underwent necropsy and the ex vivo livers were grossly and histopathologically analyzed. Results: Transsinusoidal PVE was successfully performed in five of eight pigs (63%). In 14 of 21 injections (67%), a segmental portal vein could be filled completely. A mean of 1.6 liver lobes per pig was embolized (range 1-2 lobes). There were no periprocedural adverse events. Focal capsular scarring was visible on the surface of two resected livers, yet the capsules remained intact. Histopathological examination showed no signs of recanalization or abscess formation. Mild inflammatory reaction to Onyx was observed in the perivascular parenchyma. Conclusions: The porcine portal vein can be embolized through injection of Onyx from a wedged position in the hepatic vein. Possible complications of transsinusoidal PVE and the effect on contralateral hypertrophy need further study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Protective Embolization of the Gastroduodenal Artery with a One-HydroCoil Technique in Radioembolization Procedures

Protective occlusion of the gastroduodenal artery (GDA) is required to avoid severe adverse effects and complications in radioembolization procedures. Because of the expandable features of HydroCoils, our goal was to occlude the GDA with only one HydroCoil to provide particle reflux protection. Twenty-three subjects with unresectable liver tumors, who were scheduled for protective occlusion of the GDA before radioembolization therapy, were included. The primary end point was to achieve a proximal occlusion of the GDA with only one detachable HydroCoil. Evaluated parameters were duration of deployment, and early (during the intervention) and late (7-21 days) occlusion rates of GDA. Secondary end points included complete duration of the intervention, amount of contrast medium used, fluoroscopy rates, and adverse effects. In all cases, the GDA was successfully occluded with only one HydroCoil. The selected diameter/length range was 4/10 mm in 2 patients, 4/15 mm in 6 patients, and 4/20 mm in 15 patients. HydroCoils were implanted, on average, 3.75 mm from the origin of the GDA (range 1.5-6.8 mm), with an average deployment time of 2:47 (median 2:42, range 2:30-3:07) min. In 21 (91%) of 23 patients, a complete occlusion of the GDA was achieved during the first 30 min after the coil implantation; however, in all patients, a late occlusion of the GDA was present after 6 to 29 days. No clinical or technical complications were reported. We demonstrated that occlusion of the GDA with a single HydroCoil is a safe procedure and successfully prevents extrahepatic embolization before radioembolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 {+-} 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 {+-} 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 {+-} 0.42 Gy) were <2 Gy without relevant dependence on procedure complexity. Local DRL values for kerma area product (KAP), fluoroscopy time (FT), and number of frames (N{sub FR}) were 269 Gy cm{sup 2}, 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1-102.7, p < 0.05) and N{sub FR} overexposures (OR 10.8, 95 % CI 1.1-109.5, p < 0.05). Type I aortic arch decreased the risk of FT overexposure (OR 0.4, 95 % CI 0.1-0.9, p = 0.042), and stenosis {>=} 90 % increased the risk of N{sub FR} overexposure (OR 2.8, 95 % CI 1.1-7.4, p = 0.040). At multivariable analysis, stenosis {>=} 90 % (OR 2.8, 95 % CI 1.1-7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1-109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preoperative Direct Puncture Embolization of Advanced Juvenile Nasopharyngeal Angiofibroma in Combination with Transarterial Embolization: An Analysis of 22 Consecutive Patients

ObjectiveThis study was designed to evaluate the clinical application of preoperative auxiliary embolization for juvenile nasopharyngeal angiofibroma (JNA) by direct puncture embolization (DPE) of the tumor in combination with transarterial embolization (TAE). The study included 22 patients. An 18-gauge needle was used to puncture directly into the tumor, and 20-25 % N-butyl cyanoacrylate was injected under the guidance of fluoroscopy after confirming the placement of the needle into the JNA and no leaking into the surrounding tissue. Tumors were obstructed later via TAE. The supplying arteries of JNA were from branches of the internal carotid and external carotid arteries. Control angiography showed the obliteration of contrast stain in the entire tumor mass and the distal supplying arteries disappeared after DPE in combination with TAE. Surgical resection was performed within 4 days after embolization and none of the patients required blood transfusion. The use of DPE in combination with TAE was a safe, feasible, and efficacious method. It can devascularize effectively the JNAs and reduce intraoperative bleeding when JNAs are extirpated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Short-Term Effects of Ankaferd Hemostat for Renal Artery Embolization: An Experimental Study

Renal artery embolization (RAE) is a minimally invasive therapeutic technique that is utilized in a number of disorders. Ankaferd is a novel hemostatic agent with a new mechanism of action independent of clotting factors. We used Ankaferd for RAE in a sheep model. Seven adult female sheep were included in the study. Selective renal arteriogram using 5-F diagnostic catheter was performed to make sure that each kidney was fed by a single renal artery and the animal had normal renal vasculature. Coaxial 2.7-F microcatheter was advanced to the distal main renal artery. Under fluoroscopic guidance, 2 mL of Ankaferd mixed with 2 mL of nonionic iodinated contrast agent was slowly injected. Fluoroscopy was used to observe the deceleration of flow and stagnation. Control renal angiograms were performed just after embolization. After the procedure, the animals were observed for 1 day and then sacrificed with intravenous sodium thiopental. The technical success was observed in seven of the seven animals.. After embolization procedure, none of the animals died or experienced a major systemic adverse event. On macroscopic examination of the embolized kidneys, thrombus at the level of main renal artery formed after Ankaferd embolization was more compact compared with the thrombi that was not Ankaferd-associated, which was observed elsewhere. Microscopically, majority of the renal tubular cells (80-90 %) were necrotic, and there was epithelial cell damage in a small portion of the cells (10-20 %). RAE was safe and effective in the short-term with Ankaferd in studied animals. Further studies should be conducted to better delineate the embolizing potential of this novel hemostatic agent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗