Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FIBERGLASS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-humid Climates

BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Cold Climates - Bolingbrook, IL 60440 BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Hot-Humid Climates - Friendswood, TX 77546 To understand the long-term moisture performance of unvented roof assemblies with fibrous insulation, the U.S. Department of Energy's Building America team Building Science Corporation built and monitored test roofs in two climates: a cold-climate test house in Bolingbrook, Illinois (Chicago area; zone 5A), and a hot-humid test house in Friendswood, Texas (Houston area, zone 2A). The Chicago-area test bed had seven parallel experimental rafter bays. The assemblies included a control vented compact (cathedral) roof, a dense-pack cellulose unvented roof, and an unvented roof with a "diffusion vent" (a strip of vapor-permeable gypsum sheathing at the ridge to allow drying). The interior finish was gypsum wallboard (GWB) with latex paint. The other four bays were top vent roof assemblies, which have a polypropylene breather mesh between the roof sheathing and the asphalt shingles to allow ventilation drying of the assembly from underneath the vapor-impermeable shingles. Two of the four "top vent" roofs were fiberglass batt and two were dense-pack cellulose roofs with either interior GWB or open to the interior. Wintertime moisture-related failure was accelerated by providing interior humidification (22.2 degree C [72 degree F]/50% relative humidity [RH]), which is known to be an extreme interior loading). Data were captured over 8 months, including a winter and the following spring and early summer.

Array↗

Post-Deployment Characterization of Glass Fiber-Reinforced Thermoset and Thermoplastic Composite Tidal Turbine Blades

In 2021, the National Renewable Energy Laboratory (NREL) supported Verdant Power with the most successful tidal energy deployment in U.S. history. Three of their Gen5d 5 m turbines were deployed as part of the Roosevelt Island Tidal Energy project. Initially, the three rotors initially deployed were manufactured from glass fiber-reinforced epoxy composites. Midway through the deployment, one rotor was replaced with one manufactured at NREL. The new rotor utilized a novel infusible thermoplastic resin system. Since the deployment, one epoxy rotor and one thermoplastic rotor were returned to NREL for continued materials and manufacturing research. The two rotors underwent full-scale structural testing before being sectioned and cut into specimens for a variety of manufacturing quality tests, thermomechanical characterization, and evaluation of material performance in marine environments to understand the key differences between the fiberglass-reinforced epoxy and Elium composites used for the respective rotors. Matrix burn-off tests showed that the Elium blades had a considerably higher fiber volume fraction compared to the epoxy blades (61% vs. 49%). Environmental aging of the specimens showed that the epoxy laminates absorbed more water over the conditioning period; however, it was determined that the Elium laminates had higher diffusion coefficients, so they initially absorbed water faster. Finally, one full epoxy blade and one full Elium blade were conditioned at ambient temperatures for up to 11 months, while periodic mass measurements were taken. The datasets were extrapolated to assume a full 20-year operational life span, and it was determined that the blades would not reach full saturation during that time span.

composite manufacturing↗

Contextualizing Wind Turbine Blade Waste: Comparison to Other Global Waste Streams

Worldwide wind energy generation capacity has grown rapidly over the past several decades, and wind turbines installed at the beginning of this wave of growth are approaching the end of their design lifetimes. As an increasing number of wind power plants reach their end of life, both decommissioning and repowering (i.e., dismantling or refurbishing existing turbines and commissioning new ones) will produce waste material from the retired wind turbines, foundations, and balance of plant. However, the amount and type of waste, particularly for wind blades, is often mischaracterized. Although wind turbine components are largely recyclable, the blades are typically made of fiberglass composites, which can present challenges for material recovery and reuse. Within the USA, the accumulation of wind turbine blades in landfills has raised questions about whether the continued expansion of wind energy is sustainable if it results in substantial future waste. This study compares the mass and volume of potential global wind blade waste to other waste streams. It also discusses the materials used to manufacture wind turbine blades and summarizes current options for material redesign, recycling (recovery and reuse), repurposing, and disposal of used blades. The analysis indicates that, although wind turbine blades could represent 14% of the composite market by 2027, the potential future mass and volume of wind turbine blade waste is relatively small compared to other industries. These findings suggest that although the development of scalable, economically viable, and environmentally sustainable methods for wind turbine manufacturing, repurposing, and recycling is important, it may make sense to take advantage of synergies among multiple industries in recycling composite waste, rather than focusing solely on wind turbine blades. From a global perspective, larger sustainability, recycling, and waste stream reduction impacts can be made in other industries, such as transportation and construction.

17 WIND ENERGY↗

Operating Hardware Impact on the Heat Transfer Properties of Windows

Despite significant advancements in fenestration technology in the last two decades, the thermal transmittance of fenestration products is still significantly higher than that of walls. This corresponds to 60% of the total energy loss of a modern building envelope through the windows. Hence, further development and improvements of fenestration products are necessary. Increasingly stringent codes and standards for fenestration stimulate industry to work on improved solutions. Thus, it is crucial that assessment techniques are able to account for innovations accurately. The thermal effects of non-continuous hardware in window frames are currently ignored by international rating procedures. A preliminary investigation conducted by our team showed significant performance degradation in two of the three out-opening casement profiles caused by the presence of operating hardware. Frames with the structure made of vinyl and fiberglass consist of many air cavities that are penetrated by operating hardware made of highly conductive materials. In these frames, in order to have an accurate assessment, it may be required to employ three-dimensional modeling due to the convective nature of heat transfer within the cavities. However, in this study, we demonstrate that the three-dimensional (3D) effects of non-continuous hardware can be approximated accurately with simpler two-dimensional (2D) simulations. We then develop a simplified model based on weighted average capable of replacing the time- and computation-intensive 3D simulations with 2D simulations and validate it against market available frames and their corresponding hardware. Validation results show that our approximation technique results in discrepancies lower than 0.05 W/(m2K), or 3% of the total thermal transmittance. Thus, we conclude that simplified 2D simulation models may be used for predicting hardware impact in window frames with reasonable accuracy. As windows and glazing structures are becoming ever better thermally insulated, it is becoming even more important to be able to model the impact of the operating hardware on the total thermal performance in order to design the best windows possible and not let the operating hardware ruin an otherwise well-proven design, which is hence addressed in this study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Highly Insulated Wall Systems with Exterior Insulation of Polyisocyanurate under Different Facer Materials: Material Characterization and Long-Term Hygrothermal Performance Assessment

The application of exterior insulation in both new construction and retrofits is a common practice to enhance the energy efficiency of buildings. In addition to increased thermal performance, the rigid insulation can serve to keep the sheathing board warm and serve as a water-resistive barrier to keep moisture-related problems due to condensation and wind-driven rain. Polyisocyanurate (PIR) rigid boards have a higher thermal resistance in comparison to other commonly used exterior insulation boards. However, because of its perceived lower permeance, its use as exterior insulation is not very common. In this study, the hygrothermal property of PIR boards with different facer types and thicknesses is characterized. The material data obtained through experimental test and extrapolation is used in a long term hygrothermal performance assessment of a wood frame wall with PIR boards as exterior insulation. Results show that PIR with no facer has the smallest accumulated moisture on the sheathing board in comparison to other insulation boards. Walls with a bigger thickness of exterior insulation perform better when no vapor barrier is used. The PIR exterior insulation supports the moisture control strategy well in colder climates in perfect wall scenarios, where there is no air leakage and moisture intrusion. In cases where there is trapped moisture, the sheathing board has a higher moisture content with PIR boards with both aluminum or fiberglass type facers. An innovative facer material development for PIR boards can help efforts targeting improved energy-efficient and durable wall systems.

36 MATERIALS SCIENCE↗

Full-scale-tank ground-hold tests

Ground hold test of fiberglass constrictive wrap, hermetically sealed, foam insulated, full scale Centaur tank filled with liquid hydrogen

GROUND TEST↗

Thermal control of a Mars entry capsule.

Thermal control of Mars entry capsule with fiberglass honeycomb sandwich shell analyzed with and without aft thermal curtain, emphasizing cruise-flight phase

Stultz, J. W.↗

Thermal control of a Mars entry capsule.

Thermal control of Mars entry capsule with fiberglass honeycomb sandwich shell analyzed with and without aft thermal curtain, emphasizing cruise-flight phase

Stultz, J. W.↗

Composite overwrapped metallic tanks

Tension, biaxial, and creep tests of 5Al-2.5Sn titanium alloy and computerized design for fiberglass-epoxy overwrapped titanium pressure vessel

Feldman, A.↗