Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FARADAY EFFECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A method for eliminating Faraday rotation in cryostat windows in longitudinal magneto-optical Kerr effect measurements

A solution to the problem of disturbing effect of the background Faraday rotation in the cryostat windows on longitudinal magneto-optical Kerr effect (LMOKE) measured under vacuum conditions and/or at low temperatures is proposed. The method for eliminating the influence of Faraday rotation in cryostat windows is based on special arrangement of additional mirrors placed on sample holder. In this arrangement, the orientation of the cryostat window is perpendicular to the light beam direction and parallel to an external magnetic field generated by the H-frame electromagnet. The operation of the LMOKE magnetometer with the special sample holder based on polarization modulation technique with a photo-elastic modulator is theoretically analyzed with the use of Jones matrices, and formulas for evaluating of the actual Kerr rotation and ellipticity of the sample are derived. The feasibility of the method and good performance of the magnetometer is experimentally demonstrated for the LMOKE effect measured in Fe/Au multilayer structures. The influence of imperfect alignment of the magnetometer setup on the Kerr angles, as derived theoretically through the analytic model and verified experimentally, is examined and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of irregularity anisotropy on Faraday polarization fluctuations

The previous model (Lee et al., 1982) of the Faraday polarization fluctuations (FPF) is extended after taking into account the anisotropic nature of the commonly observed, rodlike and sheetlike ionospheric irregularities. Striking effects of irregularity anisotropy are found in the longitudinal radio propagation. However, if the wave propagation angle is not small (say, greater than 5 deg), the effects of irregularity anisotropy on FPF introduced by rodlike irregularities weaken significantly, while those caused by sheetlike irregularities remain prominent. Therefore, under the same ionospheric propagation conditions, sheetlike ionospheric irregularities are more effective than rodlike ionospheric irregularities in causing the FPF of radio waves. It is expected that intense FPF of VHF radio signals can be observed not only near the equatorial anomaly but also in the auroral region.

Lee, M. C.↗

Interaction between Faraday rotation and Cotton-Mouton effects in polarimetry modeling for NSTX

The evolution of electromagnetic wave polarization is modeled for propagation in the major radial direction in the National Spherical Torus Experiment with retroreflection from the center stack of the vacuum vessel. This modeling illustrates that the Cotton-Mouton effect-elliptization due to the magnetic field perpendicular to the propagation direction-is shown to be strongly weighted to the high-field region of the plasma. An interaction between the Faraday rotation and Cotton-Mouton effects is also clearly identified. Elliptization occurs when the wave polarization direction is neither parallel nor perpendicular to the local transverse magnetic field. Since Faraday rotation modifies the polarization direction during propagation, it must also affect the resultant elliptization. The Cotton-Mouton effect also intrinsically results in rotation of the polarization direction, but this effect is less significant in the plasma conditions modeled. The interaction increases at longer wavelength and complicates interpretation of polarimetry measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ionospheric Specifications for SAR Interferometry (ISSI)

The ISSI software package is designed to image the ionosphere from space by calibrating and processing polarimetric synthetic aperture radar (PolSAR) data collected from low Earth orbit satellites. Signals transmitted and received by a PolSAR are subject to the Faraday rotation effect as they traverse the magnetized ionosphere. The ISSI algorithms combine the horizontally and vertically polarized (with respect to the radar system) SAR signals to estimate Faraday rotation and ionospheric total electron content (TEC) with spatial resolutions of sub-kilometers to kilometers, and to derive radar system calibration parameters. The ISSI software package has been designed and developed to integrate the algorithms, process PolSAR data, and image as well as visualize the ionospheric measurements. A number of tests have been conducted using ISSI with PolSAR data collected from various latitude regions using the phase array-type L-band synthetic aperture radar (PALSAR) onboard Japan Aerospace Exploration Agency's Advanced Land Observing Satellite mission, and also with Global Positioning System data. These tests have demonstrated and validated SAR-derived ionospheric images and data correction algorithms.

Pi, Xiaoqing↗

Rocket radio measurement of electron density in the nighttime ionosphere

One experimental technique based on the Faraday rotation effect of radio waves is presented for measuring electron density in the nighttime ionosphere at midlatitudes. High frequency linearly-polarized radio signals were transmitted to a linearly-polarized receiving system located in a spinning rocket moving through the ionosphere. Faraday rotation was observed in the reference plane of the rocket as a change in frequency of the detected receiver output. The frequency change was measured and the information was used to obtain electron density data. System performance was evaluated and some sources of error were identified. The data obtained was useful in calibrating a Langmuir probe experiment for electron density values of 100/cu cm and greater. Data from two rocket flights are presented to illustrate the experiment.

Gilchrist, B. E.↗

Dynamic Nuclear Polarization Enhanced Nuclear Spin Optical Rotation

Here, nuclear spin optical rotation (NSOR) has been investigated as a magneto-optical effect, which holds the potential for applications, including hybrid optical-nuclear magnetic resonance (NMR) spectroscopy and gradientless imaging. The intrinsic nature of NSOR renders its detection relatively insensitive, which has prevented it moving from a proof of concept to a method supporting chemical characterizations. In this work, the dissolution dynamic nuclear polarization technique is introduced to provide nuclear spin polarization, increasing the signal-to-noise ratio by several thousand times. NSOR signals of 1 H and 19 F nuclei are observed in a single scan for diluted compounds, which has made this effect suitable for the determination of electronic transitions from a specific nucleus in a large molecule.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

On neutralized currents in the solar corona

Using Ampere's integral law applied to vector magnetograph transverse field data, the current pattern in an active region associated with flaring activity is analyzed. The greater sensitivity of this integral formalism of Ampere's law may allow one to identify regions of weak return current around the actual positive current region. The effects of Faraday rotation on the inferred magnetic field measurements, and hence on the deduced current pattern, are discussed. It is concluded that the current patterns in the region consist either of a neutralized current system, well modeled by a coaxial cable, or of a potential field, with the apparent currents in the core an artifact induced by magneto-optical effects. In either case, the data do not convincingly show an unneutralized current system.

Wilkinson, Ladye K.↗

A graphene-based magnetoplasmonic metasurface for actively tunable transmission and polarization rotation at terahertz frequencies

The rise of terahertz (THz)-based technologies has prompted intense interest in methods for manipulating the properties of THz radiation. In this Letter, we experimentally demonstrate a graphene micro-ribbon-based metasurface that allows us to tailor and dynamically tune the transmission and polarization rotation spectra of impinging THz pulses. This is achieved by controlling the geometry of the ribbon pattern and the applied DC magnetic field, both of which strongly influence the magnetoplasmonic response of the metasurface. The properties of the metasurface can be accurately modeled using an effective medium approach that considers the capacitive interaction of the ribbons resulting from the THz electric field. Furthermore, our results highlight the promise of graphene-based THz devices that leverage the strongly enhanced light–matter interactions resulting from patterning.

36 MATERIALS SCIENCE↗

Effects of off-stoichiometry and density on the magnetic and magneto-optical properties of yttrium iron garnet films by magnetron sputtering method

Yttrium iron garnet films were deposited on Si and Si/CeO{sub 2} substrates by magnetron sputtering method followed by postannealing. By varying the fabrication parameters such as sputtering atmosphere, sputtering power, and annealing atmosphere, single phase garnet films were obtained with different off-stoichiometry and film density. The dependence of cation ratio, magnetic and magneto-optical characteristics, and absorption coefficient were systemically investigated. The results reveal that a proper oxygen pressure in both sputtering and annealing process give rise to a small cation ratio of (Fe{sup 2+} or Fe{sup 4+})/Fe{sup 3+}, thus is beneficial to obtain large saturation magnetization, large Faraday rotation, and small optical absorption. The sputtering power can also affect the properties of the film through changing the film density. Our results indicate that the properties of sputtering deposited yttrium iron garnet (YIG) film can be easily tuned and optimized by modifying the off-stoichiometry and density of the film, thus provides flexibility to fabricate YIG film for extensive applications.

36 MATERIALS SCIENCE↗

Study of magneto-optic effect on Mn{sub 1-x}Zn{sub x}Fe{sub 2}O{sub 4} nanoferrofluids

Mn{sub 1-x}Zn{sub x}Fe{sub 2}O{sub 4} nanoparticles (with x varying as 0.1, 0.3, 0.5, 0.7 and 0.9) have been synthesized by co- precipitation method using polyvinyl alcohol as surfactant. Structural analysis and surface morphology of the samples were analysed using X-ray diffraction and scanning electron microscope respectively. The Scherer approximation was used to obtain crystallite sizes and found to decrease from 8.9 nm to 4.3 nm with increase in zinc substitution. The chemical composition of samples obtained through EDAX was comparable with the initial substitutions. Saturation magnetization (M{sub s}), Remanence (M{sub r}) and Coercivity (H{sub c}) were measured using VSM at room temperature and found to decrease with increase in zinc substitution. Verdet constant of the samples are obtained from Faraday rotation for various magnetic fields and it varies from 18 × 10{sup −4} to 3 × 10{sup −4}deg/Gcm with zinc substitution.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Compact Polarimetry in a Low Frequency Spaceborne Context

Compact polarimetry has been shown to be an interesting alternative mode to full polarimetry when global coverage and revisit time are key issues. It consists on transmitting a single polarization, while receiving on two. Several critical points have been identified, one being the Faraday rotation (FR) correction and the other the calibration. When a low frequency electromagnetic wave travels through the ionosphere, it undergoes a rotation of the polarization plane about the radar line of sight for a linearly polarized wave, and a simple phase shift for a circularly polarized wave. In a low frequency radar, the only possible choice of the transmit polarization is the circular one, in order to guaranty that the scattering element on the ground is illuminated with a constant polarization independently of the ionosphere state. This will allow meaningful time series analysis, interferometry as long as the Faraday rotation effect is corrected for the return path. In full-polarimetric (FP) mode, two techniques allow to estimate the FR: Freeman method using linearly polarized data, and Bickel and Bates theory based on the transformation of the measured scattering matrix to a circular basis. In CP mode, an alternate procedure is presented which relies on the bare surface scattering properties. These bare surfaces are selected by the conformity coefficient, invariant with FR. This coefficient is compared to other published classifications to show its potential in distinguishing three different scattering types: surface, doublebounce and volume. The performances of the bare surfaces selection and FR estimation are evaluated on PALSAR and airborne data. Once the bare surfaces are selected and Faraday angle estimated over them, the correction can be applied over the whole scene. The algorithm is compared with both FP techniques. In the last part of the paper, the calibration of a CP system from the point of view of classical matrix transformation methods in polarimetry is proposed.

radar polarization diversity↗

Multi-nuclide AMS system at the University of Tsukuba

A multi-nuclide AMS system on the 12UD Pelletron tandem accelerator at the University of Tsukuba (Tsukuba AMS system) can measure environmental levels of long-lived radioisotopes of {sup 14}C, {sup 26}Al, {sup 36}Cl and {sup 129}I by employing a molecular pilot beam. AMS is an ultrasensitive technique for the study of long-lived radioisotopes, and stable isotopes at very low abundances. The high terminal voltage has an advantage in the detection of heavy radioisotopes. Much progress has been made in the development of new AMS techniques. For example, a standard deviation of the fluctuation for the {sup 36}Cl/Cl ratio is +- 2%, and the effective detection limit is better than 1x10{sup -15}. In recent years, the main research field of the 12UD Pelletron tandem accelerator has shifted to accelerator mass spectrometry (AMS) research from nuclear physics. This report presents an overview of the Tsukuba AMS system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laser-driven relativistic electron beam interaction with solid dielectric

The multi-frames shadowgraphy, interferometry and polarimetry diagnostics with sub-ps time resolution were used for an investigation of ionization wave dynamics inside a glass target induced by laser-driven relativistic electron beam. Experiments were done using the 50 TW Leopard laser at the UNR. For a laser flux of {approx}2 Multiplication-Sign 10{sup 18}W/cm{sup 2} a hemispherical ionization wave propagates at c/3. The maximum of the electron density inside the glass target is {approx}2 Multiplication-Sign 10{sup 19}cm{sup -3}. Magnetic and electric fields are less than {approx}15 kG and {approx}1 MV/cm, respectively. The electron temperature has a maximum of {approx}0.5 eV. 2D interference phase shift shows the 'fountain effect' of electron beam. The very low ionization inside glass target {approx}0.1% suggests a fast recombination at the sub-ps time scale. 2D PIC-simulations demonstrate radial spreading of fast electrons by self-consistent electrostatic fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EVOLUTION AND DISTRIBUTION OF MAGNETIC FIELDS FROM ACTIVE GALACTIC NUCLEI IN GALAXY CLUSTERS. I. THE EFFECT OF INJECTION ENERGY AND REDSHIFT

We present a series of cosmological magnetohydrodynamic simulations that simultaneously follow the formation of a galaxy cluster and evolution of magnetic fields ejected by an active galactic nucleus (AGN). Specifically, we investigate the influence of both the epoch of the AGN (z {approx} 3-0.5) and the AGN energy ({approx}3 x 10{sup 57}- 2 x 10{sup 60} erg) on the final magnetic field distribution in a relatively massive cluster (M{sub vir} {approx} 10{sup 15} M{sub sun}). We find that as long as the AGN magnetic fields are ejected before the major mergers in the cluster formation history, magnetic fields can be transported throughout the cluster and can be further amplified by the intracluster medium (ICM) turbulence caused by hierarchical mergers during the cluster formation process. The total magnetic energy in the cluster can reach {approx}10{sup 61} erg, with micro Gauss fields distributed over the {approx}Mpc scale. The amplification of the total magnetic energy by the ICM turbulence can be significant, up to {approx}1000 times in some cases. Therefore even weak magnetic fields from AGNs can be used to magnetize the cluster to the observed level. The final magnetic energy in the ICM is determined by the ICM turbulent energy, with a weak dependence on the AGN injection energy. We discuss the properties of magnetic fields throughout the cluster and the synthetic Faraday rotation measure maps they produce. We also show that high spatial resolution over most of the magnetic regions of the cluster is very important to capture the small-scale dynamo process and maintain the magnetic field structure in our simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

An assessment of generating quasi-static magnetic fields using laser-driven “capacitor” coils

Over the previous decade, numerous experiments have been performed using a laser to drive a strong, quasi-static magnetic field. Field strength and energy density measurements of these experiments have varied by many orders of magnitude, painting a confusing picture of the effectiveness of these laser-driven coils (LDCs) as tools for generating consistent fields. At the higher end of the field energy spectrum, kilotesla field measurements have been used to justify future experimental platforms, theoretical work, and inertial confinement fusion concepts. In this paper, we present the results from our own experiments designed to measure magnetic fields from LDCs as well as a review of the body of experiments that have been undertaken in this field. Here, we demonstrate how problems with prior diagnostic analyses have led to overestimations of the magnetic fields generated from LDCs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status of NIO1 construction

The NIO1 (Negative Ion Optimization phase 1) project consists of a multiaperture negative ion source mounted on a 60 kV accelerating column; up to 9 beamlets (15 mA H{sup -} each one) arranged in 3x3 matrix with 14 mm spacing can be extracted. The moderate size and the modular concept make some relative rotation of the source magnetic filter and the electrodes possible, so that the effect of crossed and aligned field can be easily compared. Other goals of source experimental program are emittance (and beam profile) measurement at several distances (for simulation code validation), testing of diagnostic components and of radiofrequency coupling. A full set of construction drawing was completed; also the Fast Emittance Scanner (FES) and its vacuum chambers were built (four mounting positions are reserved to FES). Some low power rf matching boxes were developed for a test plasma, approximately half the source size. A cesium oven compatible with NIO1 is being also developed; by using some industrial standard 100 W heaters (with a proper driver) a careful control of temperature is planned.

43 PARTICLE ACCELERATORS↗

Study of magneto-optical characteristics of cerium incorporated yttrium iron garnet films

Highlights: • Ce:YIG films deposited by sol–gel method. • XRD results shows crystallite size of films decreases by Ce concentrations. • Morphological studies indicate of smooth and connected surface for all films. • Ce ions increased Faraday rotation of YIG films. - Abstract: In the current study, yttrium iron garnet films incorporated with cerium with the general formula of Ce{sub x}Y{sub 3-x}Fe{sub 5}O{sub 12} and values of (x = 0, 0.1, 0.3, 0.5, 0.7) were prepared through sol–gel method using spin coating technique and heating treatment on quartz substrates. Prepared samples were studied to check physical characteristics. X-ray diffraction analysis (XRD), scanning electron microscope (SEM), atomic force microscope (AFM) and vibrating sample magnetometer (VSM) were applied to study the impact of Ce impurities on the structural characteristic, surface morphology of films and magnetic properties, respectively. Faraday rotation values of samples were measured at the wavelength of 632 nm. The image of the atomic force microscope (AFM) of the prepared samples shows that the films have a continuous and smooth surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗