Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Emissions Minimization Controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Simulation and Controls for Heavy Duty Dual Mode Hybrid Powertrain (Final CRADA Report)

Hybrid powertrains are of considerable interest because of potential reductions in fuel consumption, criteria pollutants and green house gas (GHG) emissions. Parallel hybrids have been applied to light and medium duty trucks, where urban driving cycles are prevalent, while series hybrids have been successfully used for other applications like transit and school buses. Unfortunately, hybridization of the Class 8, heavy-duty (HD) powertrain is inherently challenging due the expected long-haul driving requirements and limited opportunities for regenerative braking. The Participant has conceived and demonstrated a transformational Dual Mode Hybrid Powertrain (DMHP) technology developed specifically for the needs and function of Class 8 line haul trucks. The DMHP system enables a new paradigm in powertrain operational efficiency in the Class 8 truck segment. It decouples the connection between the engine operating point and the truck road load demands over a broad operating range through an innovative hybrid design. The DMHP operation choices include running in full series, full parallel and engine-off modes. The DMHP offers the opportunity for an engine to operate in a narrow range, thus providing a strategy for maximized fuel economy and minimized emissions. Further, it is expected that transient torque and power wheel demands are handled in whole or part by the electric system, thus reducing the frequency and intensity of engine transients and further improving the fuel economy and emissions. Fuel consumption and emissions have been further reduced through the elimination of overnight hoteling and idling at stops. Finally, based on the unique operating profile of an engine integrated into our hybrid powertrain, a transformational HD truck engine design concept next can emerge. Recent research activities by Oak Ridge National Laboratory (ORNL) have yielded significant data in real-life speed and load profiles of Class 8, long haul trucks. In addition, preliminary simulations of the DMHP carried out by ORNL reveal significant optimization opportunities of the DMHP by applying systematic simulation and controls approaches. An improved understanding of the complex interactions offered by the on-board engine, energy storing system, and electric machines is necessary for the development of control methodologies and practical implementation. We will continue to further this understanding through detailed experimentation and modeling, drawing on and expanding ORNL’s core competency in basic engine research and development (R&D) and advanced controls. This knowledge will be used to develop, implement, and evaluate control strategies on an actual DMHP using Meritor’s components and subsystems. Our initial focus will be on optimization of DMHP utilizing a “stock” diesel engine that is commercially available in the market place. A new DMHP-specific engine design concept will be pursued at a later phase of this Cooperative Research and Development Agreement (CRADA). Meritor will develop the experimental setup, conduct sub-system experiments at their facility, and implement and evaluate potential control strategies resulting from this CRADA partnership. Oak Ridge National Laboratory (ORNL) will develop a real-time simulation model for use in real-time control of the DMHP. The model and potential algorithms will be evaluated on a HD, hybrid powertrain dynamometer facility that will also be developed at the ORNL Vehicle Systems Integration facility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Monitoring the Bragg peak location of 73 MeV/u carbon ions by means of prompt {gamma}-ray measurements

By means of a time-of-flight technique, we measured the longitudinal profile of prompt {gamma}-rays emitted by 73 MeV/u {sup 13}C ions irradiating a polymethyl methacrylate target. This technique allowed us to minimize the shielding against neutrons and scattered {gamma}-rays, and to correlate prompt gamma emission to the ion path. This correlation, together with a high counting rate, paves the way toward real-time monitoring of the longitudinal dose profile during ion therapy treatments. Moreover, the time correlation between the prompt gamma detection and the transverse position of the incident ions measured by a beam monitor can provide real-time three dimensional control of the irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Smart Ventilation for Advanced California Homes

This project investigated smart ventilation approaches to minimize energy use for providing indoor air quality (IAQ) in high performance new California homes. Evaluation criteria included annual ventilation-related energy, peak energy and time-of-use savings, and the indoor air quality relative to a minimally code-compliant ventilation system. The simulations used CONTAM’s air flow and contaminant transport model, combined with the EnergyPlus building loads model. House types representing the default California Energy Code compliance homes were investigated for four California climate zones, covering a wide range of climate types. Both single and multi-zone smart ventilation controls were investigated. Contaminant sources included contaminants emitted continuously and varying with time, temperature and relative humidity, episodic emissions from occupant activities and outdoor particles. Single-zone ventilation controls that varied ventilation depending on outdoor temperatures were able to consistently save half of ventilation-related energy without compromising long-term IAQ. Ventilation strategies that tracked occupancy were less successful, because this work included generic contaminants with constant background emission rates. Energy performance for occupancy controls improved with a one-hour pre-occupancy flush out strategy. The addition of zoning ventilation controls did not offer significant IAQ to energy improvements compared to non-zonal versions of the same ventilation system type. The best controls had HVAC energy savings of 10-20%, with individual cases reaching up to 40% savings. However, these savings cannot be achieved without worsening personal exposures for at least one contaminant. A metric is needed to assess the competing changes in exposure to different contaminants in order to determine the net-health impacts of a control strategy. Controls that directly sensed contaminants and controlled them to acceptable levels showed that the California OEHHA limit for formaldehyde completely dominates system performance, with homes not able to meet the limit even with continuous operation of a fan sized to twice the current code minimum.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of the effects of fuel spray characteristics on NO(x) formation

Results from experimental and analytical studies on NO(x) formation in a one-dimensional monodisperse spray combustion system are reported. In a previous investigation, an optimum droplet diameter was reported for minimizing NO(x) emissions. In this paper, the effects of enhanced prevaporization and droplet interactions in addition to droplet size effects on NO(x) formation are investigated by air preheating experiments. These phenomena have been incorporated into an analytical model which predicts NO(x) formed from the combustion of monodisperse fuel sprays. Both, experimental and computed results indicate the importance of the extent of prevaporization and droplet interactions on NO(x) production. Preflame vaporization controls the gas phase stoichiometry which has a significant effect on the volume of the hot gases surrounding a fuel droplet where NO(x) is formed. On the other hand, the release of fuel vapor from the droplet to the reaction zone is influenced by droplet interactions which reduce the volume of the hot gases and NO(x) production by bringing the flame closer to the droplet surface.

Sarv, H.↗

Solid Particle Number and Mass Emissions from Lean and Stoichiometric Gasoline Direct Injection Engine Operation

In this work, engine-out particle mass (PM) and particle number (PN) emissions were experimentally examined from a gasoline direct injection (GDI) engine operating in two lean combustion modes and one stoichiometric mode with a fuel of known properties. Ten steady state operating points, two constant speed load steps, and an engine cold start were examined. Results showed that solid particles emitted from the engine under steady state stoichiometric conditions had a uniquely broad size distribution that was relatively flat between the diameters of 10 and 100 nm. In most operating conditions, lean homogenous modes can achieve lower particle emissions than stoichiometric modes while improving engine thermal efficiency. Alternatively, lean stratified operating modes resulted in significantly higher PN and PM emissions than both lean homogeneous and stoichiometric modes with increased efficiency only at low engine load. Stoichiometric load steps showed minimal soot emissions while ash-mode emissions spike dramatically due to oil consumption caused by piston ring adjustment. Correlation of PN to PM for steady state stoichiometric cases was in good agreement with that reported from multiple prior studies for both diesel and stoichiometric GDI engines. However, the lean cases resulted in higher PN to PM ratios indicating more small particles per unit mass. High ash particle concentration, especially in lean operation illustrates that oil control is important for mitigating impacts on downstream gasoline particulate filters (GPF) from which ash particles are cannot be removed during filter regeneration. Further research is necessary to elucidate the origin and composition of sub-23 nm particles from GDI engines and their effect on aftertreatment technology if lean homogeneous modes are to be employed.

Bock, Noah↗

Subtask 2.18 - Advancing CO 2 Capture Technology: Partnership for CO 2 Capture (PCO 2 C) Phase III

Industries and utilities continue to investigate ways to decrease their carbon footprint. Carbon capture and storage (CCS) can enable existing power generation facilities to meet the current national CO 2 reduction goals. The Partnership for CO2 Capture Phase III focused on several important research areas in an effort to find ways to decrease the cost of capture across both precombustion and postcombustion platforms. Two flue gas pretreatment technologies for postcombustion capture, an SO 2 reduction scrubbing technology from Cansolv Technologies Inc. and the Tri-Mer filtration technology that combines particulate, NOx, and SO 2 control, were evaluated on the Energy & Environmental Research Center’s (EERC’s) pilot-scale test system. Pretreating the flue gas should enable more efficient, and therefore less expensive, CO 2 capture. Both technologies were found to be effective in pretreating flue gas prior to CO 2 capture. Two new postcombustion capture solvents were tested, one from the Korea Carbon Capture and Sequestration R&D Center (KCRC) and one from CO 2 Solutions Incorporated. Both of these solvents showed the ability to capture CO 2 while requiring less regeneration energy, which would reduce the cost of capture. Hydrogen separation membranes from Commonwealth Scientific and Industrial Research Organisation were evaluated through precombustion testing. They are composed of vanadium alloy, which is less expensive than the palladium alloys that are typically used. Their performance was comparable to that of other membranes that have been tested at the EERC. Aspen Plus® software was used to model the KCRC and CO 2 Solutions solvents and found that they would result in significantly improved overall plant performance. The modeling effort also showed that the parasitic steam load at partial capture of 45% is less than half that of 90% overall capture, indicating savings that could be accrued if 90% capture is not required. Modeling of three regional power plants using the Carnegie Mellon Integrated Environmental Control Model showed that, among other things, the use of a bypass during partial capture may minimize the size of the capture tower(s) and result in a slight reduction in the revenue required to operate the capture facility. The results reinforced that a one-size-fits-all approach cannot be taken to adding capture to a power plant. Laboratory testing indicated that Fourier transform infrared spectroscopy could be used to continuously sample stack emissions at CO 2 capture facilities to detect and quantify any residual amine or its degradation products, particularly nitrosamines. The information gathered during Phase III is important for utility stakeholders as they determine how to reduce their CO 2 emissions in a carbon-constrained world. This subtask was funded through the EERC–U.S. Department of Energy (DOE) Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FC26-08NT43291. Nonfederal funding was provided by the North Dakota Industrial Commission, PPL Montana, Nebraska Public Power District, Tri-Mer Corporation, Montana–Dakota Utilities Co., Basin Electric Power Cooperative, KCRC/Korean Institute of Energy Research, Cansolv Technologies, and CO 2 Solutions, Inc.

01 COAL, LIGNITE, AND PEAT↗

Advanced In-Furnace NO x Control for Wall and Cyclone-Fired Boilers

A NO x minimization strategy for coal-burning wall-fired and cyclone boilers was developed that included deep air staging, innovative oxygen use, reburning, and advanced combustion control enhancements. Computational fluid dynamics modeling was applied to refine and select the best arrangements. Pilot-scale tests were conducted by firing an eastern high-volatile bituminous Pittsburgh No.8 coal at 5 million Btu/hr in a facility that was set up with two-level overfire air (OFA) ports. In the wall-fired mode, pulverized coal was burned in a geometrically scaled down version of the B and W DRB-4Z® low-NO x burner. At a fixed overall excess air level of 17%, NO x emissions with single-level OFA ports were around 0.32 lb/million Btu at 0.80 burner stoichiometry. Two-level OFA operation lowered the NO x levels to 0.25 lb/million Btu. Oxygen enrichment in the staged burner reduced the NO x values to 0.21 lb/million Btu. Oxygen enrichment plus reburning and 2-level OFA operation further curbed the NO x emissions to 0.19 lb/million Btu or by 41% from conventional air-staged operation with single-level OFA ports. In the cyclone firing arrangement, oxygen enrichment of the cyclone combustor enabled high-temperature and deeply staged operation while maintaining good slag tapping. Firing the Pittsburgh No.8 coal in the optimum arrangement generated 112 ppmv NO x (0.15 lb/million Btu) and 59 ppmv CO. The optimum emissions results represent 88% NO x reduction from the uncontrolled operation. Levelized costs for additional NO x removal by various in-furnace control methods in reference wall-fired or cyclone-fired units already equipped with single-level OFA ports were estimated and compared with figures for SCR systems achieving 0.1 lb NO x /10 6 Btu. Two-level OFA ports could offer the most economical approach for moderate NO x control, especially for smaller units. O 2 enrichment in combination with 2-level OFA was not cost effective for wall-firing. For cyclone units, NO x removal by two-level OFA plus O 2 enrichment but without coal reburning was economically attractive.

01 COAL, LIGNITE, AND PEAT↗

Wood combustion nanoparticles emitted by conventional and advanced technology cordwood boilers, and their interactions in vitro with human lung epithelial monolayers

Biomass-burning boilers and stoves are widely used in many parts of the world, producing combustion emissions linked with health risks. Here, combustion emission nanoparticles (NPs) were collected from four representative wood burning boilers using oak cordwood at specific times in the burn cycle. The morphology and composition of the NPs was characterized using transmission electron microscopy and energy dispersive X-ray analysis. To determine the degree of NP cytotoxicity with human lung tissue, the combustion NPs were introduced to incubated lung bronchial epithelial monolayers (NCI-H292) in vitro at doses of 0.1×10 -6 and 3.0×10 -6 kg/L for 2 and 4 h. Histochemical analysis showed that cell death increased by a factor of 3.5 for both doses after 4 h when compared to the control. Ultrapure NPs prepared by wet chemical methods were also introduced to the epithelial lung cells for similar doses and exposure times and the cultures exhibited significantly reduced mortality. Electron microscopy was used to study the mechanism of cell mortality for the synthesized and combustion-based NPs by examining how the NP byproducts interacted with individual cell organelles. It was found that cell survival was strongly correlated with the absence of contaminants (salts, heavy metals, poly aromatic hydrocarbons) associated with the NPs entering the cells. Synthesized NPs consisting of pure carbon were relatively well tolerated and could be excreted without damaging the cell ultrastructure. Thus, careful removal of extraneous contaminants by controlling the burn cycle with a catalyst is essential to minimize the health and environmental effects of wood biofuel combustion. In better words, optimized advanced technology wood-burning boilers and stoves can provide a CO 2 -neutral energy source and significantly contribute to a future where fossil fuels have a reduced role.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mechanism for Deploying a Long, Thin-Film Antenna from a Rover

Observations with radio telescopes address key problems in cosmology, astrobiology, heliophysics, and planetary science including the first light in the Universe (Cosmic Dawn), magnetic fields of extrasolar planets, particle acceleration mechanisms, and the lunar ionosphere. The Moon is a unique science platform because it allows access to radio frequencies that do not penetrate the Earth's ionosphere and because its far side is shielded from intense terrestrial emissions. A radio antenna can be realized by using polyimide film as a substrate, with a conducting substance deposited on it. Such an antenna can be rolled into a small volume for transport, then deployed by unrolling, and a robotic rover offers a natural means of unrolling a polyimide film-based antenna. An antenna deployment mechanism was developed that allows a thin film to be deposited onto a ground surface, in a controlled manner, using a minimally actuated rover. The deployment mechanism consists of two rollers, one driven and one passive. The antenna film is wrapped around the driven roller. The passive roller is mounted on linear bearings that allow it to move radially with respect to the driven roller. Springs preload the passive roller against the driven roller, and prevent the tightly wrapped film from unspooling or "bird's nesting" on the driven spool. The antenna deployment mechanism is integrated on the minimally-actuated Axel rover. Axel is a two-wheeled rover platform with a trailing boom that is capable of traversing undulated terrain and overcoming obstacles of a wheel radius in height. It is operated by four motors: one that drives each wheel; a third that controls the rotation of the boom, which orients the body mounted sensors; and a fourth that controls the rover's spool to drive the antenna roller. This low-mass axle-like rover houses its control and communication avionics inside its cylindrical body. The Axel rover teleoperation software has an auto-spooling mode that allows a user to automatically deploy the thin-film antenna at a rate proportional to the wheel speed as it drives the rover along its trajectory. The software allows Axel to deposit the film onto the ground to prevent or minimize relative motion between the film and the terrain to avoid the risk of scraping and antenna with the terrain.

Lazio, Joseph↗

Modeling of Orbital and Attitude Dynamics of Nanosatellites Controlled via Active Electrostatic Charging

The large-scale exploration of airless bodies, such as asteroids and moons, is gaining interest, however it is limited by mobility issues: the lack of atmosphere, low gravity, and unknown soil properties pose difficult challenges for many forms of traditional locomotion. The environment in proximity of these bodies is also electrically charged due to interactions with solar wind and UV radiation. The EGlider (Electrostatic Glider) concept would be able to overcome these mobility issues by leveraging the natural environment, allowing operations in close proximity of the surface, while enabling long duration missions by minimizing propellant consumption. The EGlider is an advanced concept for small satellite mobility and propulsion, which relies on the electric fields naturally present around airless bodies in order to generate forces and torques useful for maneuvering. It does so by extending electrically charged appendages, which enable it to electrostatically soar above the surface. By differentially charging its electrodes it can also produce torques to control its attitude. The charges are maintained by continuous active ion or electron emission from the spacecraft, in order to cancel out the neutralizing influx of charges from surrounding plasma. An investigation of the spacecraft-plasma interaction was carried out. This included studying the effect of electrode geometry and calculating the charge-to-mass ratios required to enable several mission scenarios. Long, thin wire electrodes were identified to be the most power-efficient and would allow power-to-weight ratios achievable with current nanosatellite technologies. High electrode potential represents the main limiting factor for the system design. In order to test the feasibility of active control by means of differential charging, a simple 2D interaction model was developed, and a feedback controller to stabilize the vehicle was tested in a simulation environment. The results confirmed that good performance could be obtained for both position and attitude control. Finally, a dedicated software was developed for future simulation and testing of control strategies for the EGlider. This software allows to study the trajectory and attitude of an arbitrarily configured spacecraft in the proximity of an arbitrarily defined main airless body. The spacecraft can be assembled from basic parts, each with specified electrical, mass and optical properties. Efficient models allow to calculate gravitational and electrical interactions with the rotating main body and the local plasma field, as well as solar radiation pressure effects. Control models can be implemented as simple plug-in functions and easily tested. The preliminary validation campaign showed good matching with the reference cases that have been analyzed.

Corpino, Sabrina↗

Exploring the Feasibility of Dose Escalation Positron Emission Tomography-Positive Disease with Intensity-Modulated Radiation Therapy and the Effects on Normal Tissue Structures for Thoracic Malignancies

The pattern of failure is one of the major causes of mortality among thoracic patients. Studies have shown a correlation between local control and dose. Intensity-modulated radiation therapy (IMRT) has resulted in conformal dose distributions while limiting dose to normal tissue. However, thoracic malignancies treated with IMRT to highly conformal doses up to 70 Gy still have been found to fail. Thus, the need for dose escalation through simultaneous integrated boost (SIB) may prove effective in minimizing reoccurrences. For our study, 28 thoracic IMRT plans were reoptimized via dose escalation to the gross tumor volume (GTV) and planning target volume (PTV) of 79.2 Gy and 68.4 Gy, respectively. Reoccurrences in surrounding regions of microscopic disease are rare therefore, dose-escalating regional nodes (outside GTV) were not included. Hence, the need to edit GTV margins was acceptable for our retrospective study. A median dose escalation of approximately 15 Gy (64.8-79.2 Gy) via IMRT using SIB was deemed achievable with minimal percent differences received by critical structures compared with the original treatment plan. The target's mean doses were significantly increased based on p-value analysis, while the normal tissue structures were not significantly changed.

61 RADIATION PROTECTION AND DOSIMETRY↗

An Optical Oxygen Sensor for Long-Term Continuous Monitoring of Dissolved Oxygen in Perfused Bioreactors

For long-term growth of man1ITlalian cells in perfused bioreactors, it is essential to monitor the concentration of dissolved oxygen (DO) present in the culture medium to quantitate and control level of DO. Continuous measurement of the amount of DO in the cell culture medium in-line under sterile conditions in NASA's perfused bioreactor requires that the oxygen sensor provide increased sensitivity and be sterilizable and nontoxic. Additionally, long-term cell culture experiments require that the calibration be maintained several weeks or months. Although there are a number of sensors for dissolved oxygen on the market and under development elsewhere, very few meet these stringent conditions. An optical oxygen sensor (BOXY) based on dynamic fluorescent quenching and a pulsed blue LED light source was developed in our laboratory to address these requirements. Tris( 4,7 -diphenyl-l, 1 O-phenanthroline )ruthenium(II) chloride is employed as the fluorescent dye indicator. The sensing element consists of a glass capillary (OD 4.0 mm; ID 2.0 mm) coated internally with a thin layer of the fluorescent dye in silicone matrix and overlayed with a black shielding layer. Irradiation of the sensing element with blue light (blue LED with emission maximum at 475 nm) generates a red fluorescence centered at 626 nm. The fluorescence intensity is correlated to the concentration of DO present in the culture medium, following the modified non-linear Stern-Volmer equation. By using a pulsed irradiating light source, the problem of dye-bleaching, which is often encountered in long-term continuous measurements of tIns type, 'is minimized. To date we achieved sensor resolution of 0.3 mmHg at 50 mmHg p02, and 0.6 mmHg at 100 mmHg p02, with a response time of about one minute. Calibration was accomplished in sterile phosphate-buffered saline with a blood-gas analyzer (BGA) measurement as reference. Stand-alone software was also developed to control the sensor and bioreactor as well as to acquire data. Two HOXY sensors with a single calibration were employed to continuously monitor the DO in GTSF-2 medium during a Baby Hamster Kidney (BHK-21) cell culture in a Rotating Wall Perfused Vessel (RWPV) bioreactor for 90 days. HOXY sensors were located at the inlet to and outlet from the bioreactor. One of the sensors was placed between an oxygenator and the inlet to the bioreactor. The dissolved oxygen concentrations determined by both sensors were compared with those measured regularly with the BGA reference. The cell culture was maintained for 110 days. Sensor output was found to correlate well with the BGA data throughout the experiment, where the DO of the medium ranged between 25 and 50 mmHg at the bioreactor outlet and 90-130 mmHg at the bioreactor inlet. Measuring DO with the HOXY sensors versus the BGA reference indicated bias values of -2 mmHg and -15 mmHg, and precision values of +/-3mmHg and +/-16 mmHg at the bioreactor inlet and outlet, respectively.

Gao, F. G.↗

Thermal battery for portable climate control

Current technologies that provide climate control in the transportation sector are quite inefficient. In gasoline-powered vehicles, the use of air-conditioning is known to result in higher emissions of greenhouse gases and pollutants apart from decreasing the gas-mileage. On the other hand, for electric vehicles (EVs), a drain in the onboard electric battery due to the operation of heating and cooling system results in a substantial decrease in the driving range. As an alternative to the conventional climate control system, we are developing an adsorption-based thermal battery (ATB), which is capable of storing thermal energy, and delivering both heating and cooling on demand, while requiring minimal electric power supply. Analogous to an electrical battery, the ATB can be charged for reuse. Furthermore, it promises to be compact, lightweight, and deliver high performance, which is desirable for mobile applications. In this study, we describe the design and operation of the ATB-based climate control system. We present a general theoretical framework to determine the maximum achievable heating and cooling performance using the ATB. The framework is then applied to study the feasibility of ATB integration in EVs, wherein we analyze the use of NaX zeolite-water as the adsorbent-refrigerant pair. In order to deliver the necessary heating and cooling performance, exceeding 2.5 kW h thermal capacity for EVs, the analysis determines the optimal design and operating conditions. While the use of the ATB in EVs can potentially enhance its driving range, it can also be used for climate control in conventional gasoline vehicles, as well as residential and commercial buildings as a more efficient and environmentally-friendly alternative. (C) 2015 Elsevier Ltd. All rights reserved.

Narayanan, S↗

Control Technology Needs for Electrified Aircraft Propulsion Systems

Electrified aircraft propulsion (EAP) systems hold potential for the reduction of aircraft fuel burn, emissions, and noise. Currently, NASA and other organizations are actively working to identify and mature technologies necessary to bring EAP designs to reality. This paper specifically focuses on the envisioned control technology challenges associated with EAP designs that include gas turbine technology. Topics discussed include analytical tools for the dynamic modeling and analysis of EAP systems, and control design strategies at the propulsion and component levels. This includes integrated supervisory control facilitating the coordinated operation of turbine and electrical components, control strategies that seek to minimize fuel consumption and lessen the challenges associated with thermal management, and dynamic control to ensure engine operability during system transients. These dynamic control strategies include innovative control approaches that either extract or supply power to engine shafts dependent upon operating phase, which may improve performance and reduced gas turbine engine weight. Finally, a discussion of control architecture design considerations to help alleviate the propulsion/aircraft integration and certification challenges associated with EAP systems is provided.

Simon, Donald L.↗

Control Technology Needs for Electrified Aircraft Propulsion Systems

Electrified aircraft propulsion (EAP) systems hold potential for the reduction of aircraft fuel burn, emissions, and noise. Currently, NASA and other organizations are actively working to identify and mature technologies necessary to bring EAP designs to reality. This paper specifically focuses on the envisioned control technology challenges associated with EAP designs that include gas turbine technology. Topics discussed include analytical tools for the dynamic modeling and analysis of EAP systems, and control design strategies at the propulsion and component levels. This includes integrated supervisory control facilitating the coordinated operation of turbine and electrical components, control strategies that seek to minimize fuel consumption and lessen the challenges associated with thermal management, and dynamic control to ensure engine operability during system transients. These dynamic control strategies include innovative control approaches that either extract or supply power to engine shafts dependent upon operating phase, which may improve performance and reduced gas turbine engine weight. Finally, a discussion of control architecture design considerations to help alleviate the propulsion/aircraft integration and certification challenges associated with EAP systems is provided.

Engine Controls↗

Control Technology Needs for Electrified Aircraft Propulsion Systems

Electrified aircraft propulsion (EAP) systems hold potential for the reduction of aircraft fuel burn, emissions, and noise. Currently, NASA and other organizations are actively working to identify and mature technologies necessary to bring EAP designs to reality. This paper specifically focuses on the envisioned control technology challenges associated with EAP designs that include gas turbine technology. Topics discussed include analytical tools for the dynamic modeling and analysis of EAP systems, and control design strategies at the propulsion and component levels. This includes integrated supervisory control facilitating the coordinated operation of turbine and electrical components, control strategies that seek to minimize fuel consumption and lessen the challenges associated with thermal management, and dynamic control to ensure engine operability during system transients. These dynamic control strategies include innovative control approaches that either extract or supply power to engine shafts dependent upon operating phase, which may improve performance and reduced gas turbine engine weight. Finally, a discussion of control architecture design considerations to help alleviate the propulsion/aircraft integration and certification challenges associated with EAP systems is provided.

Gas Turbine Engines↗

Effect of Thermal Storage on the Performance of a Wood Pellet-fired Residential Boiler

Interest in the direct use of biomass for thermal applications as a renewable technology is increasing as is also focus on air pollutant emissions from these sources and methods to minimize the impact. This work has focused on wood pellet-fired residential boilers, which are the cleanest fuel in this category. In the residential application the load varies strongly over the course of a year and a high fraction of the load is typically under 15% of the maximum boiler capacity. Thermal storage can be used even with boilers which have modulation capacity typically to 30% of the boiler maximum. One common pellet boiler was tested at full load and also at the minimum load used in the U.S. certification testing (15%). In these tests the load was steady over the test period. Testing was also done with an emulated load profile for a home in Albany, N.Y. on a typical January, March, and April day. In this case the load imposed on the boiler varied hourly under computer control, based on the modeled load for the example case used. The boiler used has a nominal output of 25 kW and a common mixed hardwood/softwood commercial pellet was used. Moisture content was 3.77%. A dilution tunnel approach was used for the measurement of particulate emissions, in accordance with U.S. certification testing requirements. The test results showed that the use of storage strongly reduces cycling rates under part load conditions. The transients which occur as these boilers cycle contribute to increased particulate emissions and reduced efficiency. The time period of a full cycle at a given load condition can be increased by increasing the storage tank volume and/or increasing the control differential range. It was shown that increasing the period strongly increased the measured efficiency and reduced the particulate emission (relative to the no storage case). The impact was most significant at the low load levels. Storage tank heat loss is shown to be a significant factor in thermal efficiency, particularly at low load. Different methods to measure this heat loss were explored. For one of the tanks evaluated the efficiency loss at the 15% load point was found to be as high as 7.9%. Where storage is used good insulation on the tank, insulation on the piping, and attention to fittings are recommended.

09 BIOMASS FUELS↗

Use of volumetric-modulated arc therapy for treatment of Hodgkin lymphoma

To evaluate volumetric-modulated arc therapy (VMAT) for treatment of Hodgkin lymphoma (HL) in patients where conventional radiotherapy was not deliverable. A planning computed tomography (CT) scan was acquired for a twelve-year-old boy with Stage IIIB nodular sclerosing HL postchemotherapy with positive positron emission tomography scan. VMAT was used for Phase 1 (19.8 Gy in 11 fractions) and Phase 2 (10.8 Gy in 6 fractions) treatment plans. Single anticlockwise arc plans were constructed using SmartArc (Philips Radiation Oncology Systems, Fitchburg, WI) with control points spaced at 4°. The inverse-planning objectives were to uniformly irradiate the planning target volume (PTV) with the prescription dose while keeping the volume of lung receiving greater than 20 Gy (V{sub 20} {sub Gy}) to less than 30% and minimize the dose to the other adjacent organs at risk (OAR). Pretreatment verification was conducted and the treatment delivery was on an MLCi Synergy linear accelerator (Elekta Ltd, Crawley, UK). The planning results were retrospectively confirmed in a further 4 patients using a single PTV with a prescribed dose of 19.8 Gy in 11 fractions. Acceptable dose coverage and homogeneity were achieved for both Phase 1 and 2 plans while keeping the lung V{sub 20} {sub Gy} at 22.5% for the composite plan. The beam-on times for Phase 1 and Phase 2 plans were 109 and 200 seconds, respectively, and the total monitor units were 337.2 MU and 292.5 MU, respectively. The percentage of measured dose points within 3% and 3 mm for Phase 1 and Phase 2 were 92% and 98%, respectively. Both plans were delivered successfully. The retrospective planning study showed that VMAT improved PTV dose uniformity and reduced the irradiated volume of heart and lung, although the volume of lung irradiated to low doses increased. Two-phased VMAT offers an attractive option for large volume sites, such as HL, giving a high level of target coverage and significant OAR sparing together with efficient delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗