Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electromagnets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Scattering and Diffraction of Electromagnetic Radiation: An Effective Probe to Material Structure

Scattered electromagnetic waves from material bodies of different forms contain, in an intricate way, precise information on the intrinsic, geometrical and physical properties of the objects. Scattering theories, ever deepening, aim to provide dependable interpretation and prediction to the complicated interaction of electromagnetic radiation with matter. There are well-established multiple-scattering formulations based on classical electromagnetic theories. An example is the Generalized Multi-particle Mie-solution (GMM), which has recently been extended to a special version ̶ the GMM-PA approach, applicable to finite periodic arrays consisting of a huge number (e.g., >>106) of identical scattering centers [1]. The framework of the GMM-PA is nearly complete. When the size of the constituent unit scatterers becomes considerably small in comparison with incident wavelength, an appropriate array of such small element volumes may well be a satisfactory representation of a material entity having an arbitrary structure. X-ray diffraction is a powerful characterization tool used in a variety of scientific and technical fields, including material science. A diffraction pattern is nothing more than the spatial distribution of scattered intensity, determined by the distribution of scattering matter by way of its Fourier transform [1]. Since all linear dimensions entered into Maxwell's equations are normalized by wavelength, an analogy exists between optical and X-ray diffraction patterns. A large set of optical diffraction patterns experimentally obtained can be found in the literature [e.g., 2,3]. Theoretical results from the GMM-PA have been scrutinized using a large collection of publically accessible, experimentally obtained Fraunhofer diffraction patterns. As far as characteristic structures of the patterns are concerned, theoretical and experimental results are in uniform agreement; no exception has been found so far. Closely connected with the spatial distribution of scattered intensities are cross sections, such as for extinction, scattering, absorption, and radiation pressure, as a critical type of key quantity addressed in most theoretical and experimental studies of radiative scattering. Cross sections predicted from different scattering theories are supposed to be in general agreement. For objects of irregular shape, the GMM-PA solutions can be compared with the highly flexible Discrete Dipole Approximation (DDA) [4,5] when dividing a target to no more than ~106 unit cells. Also, there are different ways to calculate the cross sections in the GMM-PA, providing an additional means to examine the accuracy of the numerical solutions and to unveil potential issues concerning the theoretical formulations and numerical aspects. To solve multiple scattering by an assembly of material volumes through classical theories such as the GMM-PA, the radiative properties of the component scatterers, the complex refractive index in particular, must be provided as input parameters. When using a PA to characterize a material body, this involves the use of an adequate theoretical tool, an effective medium theory, to connect Maxwell's phenomenogical theory with the atomistic theory of matter. In the atomic theory, one regards matter as composed of interacting particles (atoms and molecules) embedded in the vacuum [6]. However, the radiative properties of atomic-scaled particles are known to be substantially different from bulk materials. Intensive research efforts in the fields of cluster science and nanoscience attempt to bridge the gap between bulk and atom and to understand the transition from classical to quantum physics. The GMM-PA calculations, which place virtually no restriction on the component-particle size, might help to gain certain insight into the transition.

Xu, Yu-Lin↗

System for Transmitting and Receiving Electromagnetic Radiation

A system for transmitting and receiving electromagnetic radiation includes a beam splitter and a transceiver. The beam splitter is configured to separate an optical pulse into a pump pulse and a probe pulse. The transceiver may include a transmitter switch and a receiver switch. The pump pulse is directed toward the transmitter switch and the probe pulse is directed towards the receiver switch. Electromagnetic radiation is emitted from the transceiver when the pump pulse strikes the transmitter switch. The electromagnetic radiation may be terahertz radiation in either a pulsed or continuous wave form.

Strong, Timothy↗

Electromagnetic Redesign of NASA’s High Efficiency Megawatt Motor

NASA’s High Efficiency Megawatt Motor (HEMM) is being developed to achieve the performance needed by single aisle class electrified aircraft. It is a 1.4 MW electric machine designed as a generator for NASA’s STARC-ABL concept vehicle. It has performance objectives of greater than 16 kW/kg electromagnetic specific power and efficiency of greater than 98%. A significant flaw in the preliminary electromagnetic design of HEMM was recently discovered. The stator teeth in the preliminary design cause the magnetic flux in the rotating components of HEMM to oscillate at a very high frequency (12,240 Hz). Two independent energy loss analyses are presented to show that the frequency is high enough to cause eddy current losses that significantly exceed the rotor’s loss limit (50 W), despite the very small magnitude of this flux oscillation (<0.01 T). To eliminate these rotor losses, while continuing to meet the target performance, it was determined that the stator teeth needed to be removed and the electromagnetic geometry of the motor needed to be revised. The revised, slotless HEMM motor design is summarized. Sensitivity of the new design to key unknown variables such as the temperature of and number of turns in the superconducting rotor coils and the stator winding’s average temperature.

Thomas T Tallerico↗

Electromagnetic Pain Relief/Blocking: Feasibility Assessment

Context/Background: Astronauts use pharmaceuticals during spaceflight to manage acute and chronic pain, but use of analgesics will have drawbacks for exploration-class missions because the shelf life of these medications is limited, resupply will be curtailed, astronauts may develop tolerance and/or addiction to these medications, and side effects can include impairment of cognitive abilities. Electromagnetic devices have been developed that treat pain terrestrially by affecting neuromodulation–dubbed “electroceuticals”, these devices have varied mechanisms of action that either stimulate or suppress neural activity in the central nervous system or peripheral nerves. Objective/Purpose: The available literature was reviewed and FDA-approved pain treatments (both pharmacological and non-pharmacological), as well as those currently under development, were assessed for their suitability for use in exploration class spaceflight missions. Data Sources: Due to the COVID-19 pandemic and the resulting closure of libraries, data sources were restricted to those available digitally. Online database searches included PubMed, U.S. Patent and Trademark Office, federal grant award databases (National Aeronautics and Space Administration (NASA), Department of Defense (DoD), National Institutes of Health (NIH)), and general internet searches. More than 1,600 records were reviewed in this effort. Study Selection/Eligibility Criteria: Targeted searches included different aspects of pain management. Priority was given to review studies, to cover as much of the available literature as possible in this limited effort. Study Appraisal and Synthesis Methods/Data Extraction and Data Synthesis: The titles of the studies and the awards that were obtained by searching online databases were reviewed and further information was sought for the relevant titles. Abstracts or award summaries were generally available online; for journal abstracts, full text articles were either available online or were requested via interlibrary loan. Results: An overwhelming majority of the literature focuses on the treatment of chronic rather than acute pain because it is assumed that acute pain only rarely fails to resolve and instead transitions into chronic pain when the central nervous system becomes hypersensitized. The available electromagnetic devices marketed for pain treatment have varying levels of invasiveness, use different mechanisms of action, and have demonstrated varying efficacy when evaluated scientifically. A truly noninvasive, highly efficient device is desired for use during spaceflight. One portable, self-contained, FDA-approved device was identified that, from preliminarily assessment, best met these criteria; the device noninvasively applies pulsed shortwave therapy (PSWT) to modify pain signals from peripheral nerves, however, the device has limited battery life and the effects are relatively non-selective in type of neural signal modified. Limitations: This current effort, although extensive, did not identify a comprehensive list of all alternatives for pain treatment. Once the pandemic limitations are lifted, a longer, more thorough effort may find additional options. Conclusions/Implications: The ideal electromagnetic pain treatment device for use on exploration-class spaceflight missions does not yet exist, but it may be available soon. It is not feasible for NASA to develop medical devices due to the schedule constraints for pending exploration-class missions, but adapting a promising device that is already FDA-approved might be an option. Monitoring research that is ongoing at other federal agencies is recommended, and further review of the candidate PSWT device identified in this current effort may be warranted.

Carol Mullenax↗

Electromagnetic Pain Relief/Blocking: Feasibility Assessment

CONTEXT/BACKGROUND Astronauts use pharmaceuticals during spaceflight to manage acute and chronic pain, but use of analgesics will have drawbacks for exploration-class missions because the shelf life of these medications is limited, resupply will be curtailed, astronauts may develop tolerance and/or addiction to these medications, and side effects can include impairment of cognitive abilities. Electromagnetic devices have been developed that treat pain terrestrially by affecting neuromodulation–dubbed “electroceuticals”, these devices have varied mechanisms of action that either stimulate or suppress neural activity in the central nervous system or peripheral nerves. OBJECTIVE/PURPOSE The available literature was reviewed and FDA-approved pain treatments (both pharmacological and non-pharmacological), as well as those currently under development, were assessed for their suitability for use in exploration class spaceflight missions. DATA SOURCES Due to the COVID-19 pandemic and the resulting closure of libraries, data sources were restricted to those available digitally. Online database searches included PubMed, U.S. Patent and Trademark Office, federal grant award databases (National Aeronautics and Space Administration (NASA), Department of Defense (DoD), National Institutes of Health (NIH)), and general internet searches. More than 1,600 records were reviewed in this effort. STUDY SELECTION/ELIGIBILITY CRITERIA Targeted searches included different aspects of pain management. Priority was given to review studies, to cover as much of the available literature as possible in this limited effort. STUDY APPRAISAL AND SYNTHESIS METHODS/DATA EXTRACTION AND DATA SYNTHESIS The titles of the studies and the awards that were obtained by searching online databases were reviewed and further information was sought for the relevant titles. Abstracts or award summaries were generally available online; for journal abstracts, full text articles were either available online or were requested via interlibrary loan. RESULTS An overwhelming majority of the literature focuses on the treatment of chronic rather than acute pain because it is assumed that acute pain only rarely fails to resolve and instead transitions into chronic pain when the central nervous system becomes hypersensitized. The available electromagnetic devices marketed for pain treatment have varying levels of invasiveness, use different mechanisms of action, and have demonstrated varying efficacy when evaluated scientifically. A truly noninvasive, highly efficient device is desired for use during spaceflight. One portable, self-contained, FDA-approved device was identified that, from preliminarily assessment, best met these criteria; the device noninvasively applies pulsed shortwave therapy (PSWT) to modify pain signals from peripheral nerves, however, the device has limited battery life and the effects are relatively non-selective in type of neural signal modified. LIMITATIONS This current effort, although extensive, did not identify a comprehensive list of all alternatives for pain treatment. Once the pandemic limitations are lifted, a longer, more thorough effort may find additional options. CONCLUSIONS/IMPLICATIONS The ideal electromagnetic pain treatment device for use on exploration-class spaceflight missions does not yet exist, but it may be available soon. It is not feasible for NASA to develop medical devices due to the schedule constraints for pending exploration-class missions, but adapting a promising device that is already FDA-approved might be an option. Monitoring research that is ongoing at other federal agencies is recommended, and further review of the candidate PSWT device identified in this current effort may be warranted.

C A Mullenax↗

Electromagnetic Compatibility Test and Analysis Campaign of NASA's Mars 2020 Rover

NASA's Mars 2020 Rover—with a launch window opening July 2020, and landing expected February 2021—has mission objectives to look for evidence of habitability, seek biosignatures of past life, collect and cache samples for possible future return to Earth, and prepare for future human missions. The Rover platform is similar to the previous Mars Science Laboratory (MSL) “Curiosity” rover that landed in 2012 but contains a new suite of scientific instruments and upgrades to existing functionality. The scientific payload includes a trio of chemical analysis tools (PIXL, SHERLOC, SuperCam), a ground penetrating radar (RIMFAX), an upgraded weather station (MEDA), upgraded high resolution camera (MastCam-Z), and an oxygen-producing experiment (MOXIE). These changes—along with new efficiency goals to operate more Rover subsystems concurrently and thus collect more science—presented new electromagnetic compatibility (EMC) challenges. In this paper, we will describe the campaign to ensure Mars 2020 mission success from an electromagnetic environment perspective: 1) confirming existing MSL heritage subsystems and EMC requirements were compatible with the new Mars 2020 mission objectives, 2) engaging with engineers and scientists early in the project to identify and evaluate risks before hardware assembly and performing ambitious risk reduction tests, 3) undertaking a comprehensive subsystem qualification test program based on tailored MIL-STD-461F requirements, occasionally leading to redesign, 4) synthesizing the data collected to perform detailed analyses toward the goal of making risk-informed decisions at a system level. The spacecraft has successfully completed all three planned system level tests, demonstrating self-compatibility with minimal impact to operations from electromagnetic interference in all mission phases.

Gonzales, Edward C↗

SelenITA: A dual-spacecraft lunar CubeSat mission to characterize the near-surface electromagnetic plasma environment

SelenITA is an international interdisciplinary mission consisting of two CubeSats that will provide the first multi-point measurement in a sustained low lunar orbit. This mission will advance the understanding of spatiotemporal differentiation of the electromagnetic space environment at the Moon in support of Artemis crew and the geosciences. The mission science objectives are to: (1) further constrain the origins of crustal magnetic fields and their applications; (2) determine the nature of plasma interactions with crustal magnetic fields; (3) characterize plasma waves and turbulence at the Moon; (4) characterize the lunar surface potential in all plasma environments; (5) constrain the composition, thermal state, and structure of the lunar upper mantle and crust; (6) characterize the ionizing radiation in lunar orbit; (7) determine the density of the dust exosphere as a function of latitude, longitude, and altitude, including the lunar polar space environment. The measurement requirements include: 3-component vector magnetic field, plasma distribution (flux, energy, density, temperature), energetic particles (protons, electrons, gamma rays), and dust. SelenITA builds on a rich history of electromagnetic plasma observations of the near lunar surface and space environment, and it answers high level science questions with state of the art instruments in a small package. PLAIN LANGUAGE ABSTRACT – SelenITA comes from the greek word for Moon, selene, with the addition of “ITA” as a reference to the Brazilian teammate, Instituto Tecnológico de Aeronáutica. In addition, in Portuguese "ita" is a prefix similar to "ite" in English, used in naming minerals, so Selenita could be seen as a lunar gemstone. In Spanish, “ita” is a diminutive suffix for “little” which is appropriate for this CubeSat mission which consists of twin 12U CubeSats in low lunar orbit. The primary science goal of the mission is to distinguish time varying features within the electromagnetic plasma environment near the surface of the Moon. The science objectives include investigating the origins of crustal magnetic fields, plasma interactions with these fields, plasma waves, surface potential, and interior properties. This mission is also interested in the radiation environment at the Moon and the amount of dust at the lunar poles. This is important because it helps us understand how future astronauts will live and work on the lunar surface and identify hazards.

space weather↗

SelenITA: A Dual-Spacecraft Lunar CubeSat Mission to Characterize the Near-Surface Electromagnetic Plasma Environment

SelenITA is an international interdisciplinary mission consisting of two CubeSats that will provide the first multi-point measurement in a sustained low lunar orbit. This mission will advance the understanding of spatiotemporal differentiation of the electromagnetic space environment at the Moon in support of Artemis crew and the geosciences. The mission science objectives are to: (1) further constrain the origins of crustal magnetic fields and their applications; (2) determine the nature of plasma interactions with crustal magnetic fields; (3) characterize plasma waves and turbulence at the Moon; (4) characterize the lunar surface potential in all plasma environments; (5) constrain the composition, thermal state, and structure of the lunar upper mantle and crust; (6) characterize the ionizing radiation in lunar orbit; (7) determine the density of the dust exosphere as a function of latitude, longitude, and altitude, including the lunar polar space environment. The measurement requirements include: 3-component vector magnetic field, plasma distribution (flux, energy, density, temperature), energetic particles (protons, electrons, gamma rays), and dust. SelenITA builds on a rich history of electromagnetic plasma observations of the near lunar surface and space environment, and it answers high level science questions with state of the art instruments in a small package. PLAIN LANGUAGE ABSTRACT – SelenITA comes from the greek word for Moon, selene, with the addition of “ITA” as a reference to the Brazilian teammate, Instituto Tecnológico de Aeronáutica. In addition, in Portuguese "ita" is a prefix similar to "ite" in English, used in naming minerals, so Selenita could be seen as a lunar gemstone. In Spanish, “ita” is a diminutive suffix for “little” which is appropriate for this CubeSat mission which consists of twin 12U CubeSats in low lunar orbit. The primary science goal of the mission is to distinguish time varying features within the electromagnetic plasma environment near the surface of the Moon. The science objectives include investigating the origins of crustal magnetic fields, plasma interactions with these fields, plasma waves, surface potential, and interior properties. This mission is also interested in the radiation environment at the Moon and the amount of dust at the lunar poles. This is important because it helps us understand how future astronauts will live and work on the lunar surface and identify hazards.

space weather↗

Heating system with induction power supply and electromagnetic acoustic transducer with induction power supply

A system for heating a fluid and an electromagnetic acoustic transducer EMAT system is provided. Both systems have a drive circuit. The amount of heat and the amplitude (and acceleration) of the vibrations is respectively controllable by controlling an input to a terminal of a switch. The heating system comprises a porous graphite foam conductor which is exposed to an electromagnetic field generated by an oscillating circuit. When exposed, the foam conductor conducts induced electric current which heats the same and a fluid in contact with the conductor. The EMAT system comprises at least one magnet configured to generate a static magnetic field, an oscillating circuit and a working element. The working element, when exposed to the static magnetic field and the electromagnetic field produced by the oscillating circuit, vibrates against a load. The vibrations dry the load.

Kisner, Roger A.↗

Spin-based detection of terahertz and sub-terahertz electromagnetic radiation

Systems and methods for spin-based detection of electromagnetic radiation at terahertz and sub-terahertz frequencies is provided. The detector can include a heterostructure, a magnetic field generator, and an electrical circuit. The heterostructure can include a first layer formed of an antiferromagnetic material (AFM) in contact with a second layer of a heavy metal (HM) or a topological insulator. The magnetic field generator can generate a magnetic field oriented approximately parallel to an easy axis of the first layer and approximately parallel to a propagation direction of electromagnetic radiation. The circuit can be in electrical communication with the second layer. The first layer can inject a spin current into the second layer in response to receipt of electromagnetic radiation having a sub-terahertz or terahertz frequency. The second layer can convert the injected spin current into a potential difference. The circuit can be configured to output a signal corresponding to the potential difference.

Shi, Jing↗

A Measurement of the Neutron Electromagnetic Form Factor Ratio from a Rosenbluth Technique with Simultaneous Detection of Neutrons and Protons

The internal structure of protons and neutrons provides insight into both the dynamical behavior of the constitute quarks and gluons, and emergent properties of the nucleons (such as mass, spin, and electromagnetic distributions). Elastic electron-nucleon scattering can probe the elastic electromagnetic form factors of the nucleon. The electric and magnetic form factors, respectively, encode information about the internal charge and magnetization distributions within the nucleon. Precision data for these form factors, over a broad range of the four-momentum transfer squared, Q^2, can benchmark theoretical models describing the strong interaction of nuclear physics. The Super BigBite Spectrometer (SBS) program in Hall A at Jefferson Lab, is a series of high-precision experiments which seek to significantly extend the Q^2 reach of previous data for the nucleon electromagnetic form factors. The first two experiments of this program are known as G_M^n and the neutron Two Photon Exchange (nTPE) and the data were collected from October 2021 to February 2022. Both experiments were conducted with the simultaneous measurement of D(e,e'n) and D(e,e'p) reactions for quasi-elastic electron-deuteron scattering. The scattered electrons were detected in the BigBite Spectrometer, which features multiple large-acceptance Gas Electron Multiplier (GEM) detectors. The Super BigBite Spectrometer provided simultaneous detection of scattered nucleons, and utilized a large acceptance dipole magnet and Hadron Calorimeter (HCal). The G_M^n experiment provides precision measurements of the neutron magnetic form factor, via the ratio method, over a Q^2 range of 3.0 to 13.5 (GeV/c)2. From this data analysis, preliminary values for G_M^n/µ_n G_D are extracted. For Q^2=4.48 (GeV/c)2 we find G_M^n/µ_n G_D=0.9546±0.0132 and for Q^2=4.476 (GeV/c)2 we find G_M^n/µ_n G_D=0.9563±0.0110. These preliminary G_M^n/µ_n G_D values are more precise than existing world data in this Q^2 regime and are consistent with the most recent parameterization of the G_M^n/µ_n G_D world data. The nTPE experiment provides a first measurement of the neutron Rosenbluth Slope and seeks to quantify the two-photon exchange(TPE) contribution to elastic electron-neutron scattering at a fixed Q^2=4.5 (GeV/c)2 with two different beam energies and scattering angle values. For data of the proton form factor ratio, µ_p G_E^p/G_M^p, significant discrepancies exist between values obtained from Rosenbluth Separation and polarization transfer measurement, particularly at large Q^2, and TPE contributions are thought to resolve this discrepancy. The impacts of TPE contributions have not yet been experimentally established for the neutron. From the data analysis presented in this dissertation, a preliminary result for the neutron Rosenbluth Slope is found as S^n=(G_E^n )^2/t_n (G_M^n )^2=0.0916±0.0476 for Q^2=4.48 (GeV/c)2. This value of the neutron Rosenbluth Slope is consistent with the world data extrapolation and the absence of large TPE corrections.

Wertz, Ezekiel [Thomas Jefferson National Accelera↗

Two-Way Coupled CFD/DEM Simulation of Electromagnetic Heating in a Fluidized Bed Reactor - Extended Abstract

A set of tools has been developed to couple a multiphase reacting computational fluid dynamics solver (MFIX) with two computational electromagnetic solvers (COMSOL and Elmer). In contrast to several recent investigations, which calculate a single static EM field prior to the CFD calculation, in the present work the electromagnetic field is periodically updated during the simulation. This enables the EM field and associated EM heating predictions to reflect the effects of evolving material properties (temperature, composition, size etc.) and the evolving distribution of material in the system. The present work uses effective medium theory (EMT) for the electromagnetic field calculations since the goal is to apply the tool for industrial scale reacting systems. Predictions using MFIX/COMSOL and MFIX/Elmer are compared to in bed thermocouple measurements from a fluidized bed experiment and recent simulation predictions and recent experiments performed at NETL. The NETL experiments also include packed bed operating conditions. Coupled MFIX/COMSOL simulations at these conditions are compared with similar simulations using only COMSOL to measure errors due to the solver coupling approach.

CFD↗

Measurement of the Neutron Elastic Electromagnetic Form Factor Ratio at Large Momentum Transfer

Exploring nucleon structure is vital both for understanding its origin and existence as well as for the advancement of the sciences. It helps us answer key questions such as how quark and gluon dynamics create 99% of the nucleon mass. Electron- nucleon scattering has been widely used for precision studies of the nucleon and nuclear structure since the Nobel Prize winning investigations by Robert Hofstadter and collaborators in the 1950s. These studies provide information about the spatial charge and current densities of the nucleon in terms of the electromagnetic form factors. The form factors are functions of four momentum transfer squared (Q2). Extending the electromagnetic form factor measurements to higher Q2 plays a critical role in furthering the understanding of nucleon structure. This motivated the Super BigBite Spectrometer (SBS) program at Jefferson Lab. The open nature of the spectrometers and the direct line of sight from the target to the tracking detector locations in experimental setups such as SBS creates high levels of background at the detectors. This necessitates the use of tracking detectors with high rate capability and good position resolution. Gas Electron Multiplier (GEM) detectors are an excellent choice for tracking detectors in such experiments. Understanding the performance of the GEM detectors is important not just for SBS experiments but also for future high-luminosity experiments. This thesis reports the exploratory results from the measurement of the neutron elastic electromagnetic form factor ratio (Gn E/Gn M) at high momentum transfer. A longitudinally polarized electron beam was scattered off a polarized 3He target, used as an effective polarized neutron target. In this experiment, the polarized 3He target achieved a world record polarization weighted luminosity at a beam current of 45 µA. Double spin asymmetry of the scattered neutron events is used to extract the neutron form factor ratio. Measurements were taken at Q2 = 3.0, 6.8, 9.8 (GeV/c)2. The lowest Q2 measurement is in good agreement with the existing world data, and the higher-Q2 measurements extend the Q2 reach well beyond the existing world data and are expected to remain unmatched for a long time.

Gamage, Vimukthi Haththotuwa [Univ. of Virginia, C↗

Characterizing the Electromagnetic Response of the NOvA Detectors

The NOvA Test Beam Program was commissioned to complement the full-scale NOvA experiment in its goal of measuring neutrino oscillations. The NOvA Experiment consists of a 300-ton Near Detector and a 14-kton Far Detector, both exposed to the same beam, which can be operated in neutrino or antineutrino mode from Fermilab at an off-axis angle of 14.6~mrad. These detectors can discriminate between $\nu_\mu$-CC and $\nu_e$-CC neutrino (or corresponding antineutrino) events, enabling appearance and disappearance measurements of these flavors across the \SI{810}{\kilo\meter} near-to-far detector baseline. From these measurements, the underlying parameters of the three-flavor PMNS oscillations framework are measured. The NOvA Test Beam uses identical technology to the full-scale detectors, but scaled down to 30~tons. It is exposed to a beam of charged particles closely matched to the daughter products of NOvA (anti)neutrino interactions in both energy and species. An instrumented beamline determines both particle momentum and species upstream of the NOvA detector, allowing for a crisp measurement of the NOvA detector response to these known inputs. This dissertation presents an analysis of the electromagnetic response of the NOvA hardware and establishes a framework for incorporating these results to enhance the physics reach of the experiment. Prior to this work, the electromagnetic energy response of the NOvA detector relied primarily on simulation-driven calibration together with a globally applied energy scale uncertainty. The measurements presented here provide direct test beam constraints on the detector response, enabling particle-dependent and potentially energy-dependent uncertainty models derived from controlled electromagnetic inputs.

Myers, Dalton Grant [U. Texas, Austin (main)] (ORC↗

Ensuring electromagnetic compatibility in grid-connected power converters: Challenges, standards, and compliance strategies

In today's rapidly advancing world, electronic devices and systems are fundamental to a wide range of industries, including renewable energy and global telecommunications infrastructure. However, as these devices become more complex and widespread, the risk of electromagnetic interference (EMI) also increases, underscoring the importance of stringent Electromagnetic Compatibility (EMC) requirements for maintaining system integrity. This paper addresses the specific challenges associated with grid-connected power converters (GCPCs), which are critical in integrating renewable energy into existing power grids. It explores the complexities of EMI in the context of GCPCs, particularly given the recent emergence of tailored EMC standards for these systems. The paper also highlights the shortcomings of applying generic or unrelated standards to GCPCs, often leading to inadequate compliance and testing protocols. Through a detailed analysis of existing standards and recent advancements in product-specific EMC requirements, this paper provides a comprehensive overview of the current landscape, offering guidance to stakeholders on navigating the intricate EMC compliance landscape, with a focus on methodologies, testing procedures, and the evolving regulatory environment for GCPCs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Three-Dimensional Deformable Grid Electromagnetic Particle-in-cell for Parallel Computers

We describe a new parallel, non-orthogonal grid, three-dimensional electromagnetic particle-in-cell (EMPIC) code based on a finite-volume formulation. This code uses a logically Cartesian grid of deformable hexahedral cells, a discrete surface integral (DSI) algorithm to calculate the electromagnetic field, and a hybrid logical-physical space algorithm to push particles.

Cartesian grid Grid Electromagnetic electromagneti↗

Lightweight, Flexible Electromagnetic Shielding Composite Films Reinforced with Recycled Carbon Fibers and Carbon Nanofillers

Lightweight, flexible polymer composites are widely adopted in modern electronic devices and systems for high-efficiency electromagnetic interference (EMI) shielding. Reinforcing polymer composites with conductive fillers offers a promising alternative to conventional metal-based shielding material thanks to their low density, tunable properties, and flexibility. Herein, lightweight, flexible ultra-high molecular weight polyethylene composite films reinforced with recycled carbon fibers (rCFs) and carbon-based nanofillers, including graphene nanoplatelets (GNPs) and carbon nanotubes, are reported for EMI shielding applications. The incorporation of these nanofillers significantly reduces the required content of rCFs and improves processability while maintaining comparable shielding effectiveness. The addition of these nanofillers with rCFs enhances the EMI shielding effectiveness by up to 15 dB. Incorporating 1 wt% GNPs can replace 5 wt% rCFs and achieve comparable EMI shielding performance, while 5 wt% of either nanofillers can substitute for 10 wt% rCFs. Numerical modeling of electromagnetic wave transmission reveals that increasing nanofiller concentrations enhances both reflection and absorption losses, with absorption consistently dominating across all levels. Furthermore, this study not only provides insight into the synergistic contributions of rCFs and carbon nanofillers to shielding effectiveness but also paves the way for the design of sustainable, lightweight EMI shielding composite films for applications in electric vehicles, medical equipment, and portable electronics.

carbon nanofiller↗

An MPMD approach coupling electromagnetic continuum mechanics approximations in ALEGRA

In this work, two complementary approximations for describing aspects of continuum electromagnetics in moving media are discussed: electroquasistatic and magnetoquasistatic. Each has been implemented in the finite element shock code ALEGRA for modeling dynamic electromechanical phenomena on typical engineering time scales, with fully integrated circuit coupling. The approximations can be obtained by consistent asymptotic balancing of Maxwell’s equations relative to timescales associated with magnetic diffusion, charge relaxation, and electromagnetic wave propagation. In ALEGRA, the electroquasistatic approximation is used for ferroelectric (FE) modeling, while the magnetoquasistatic approximation is used for magnetohydrodynamic (MHD) modeling. In this paper we introduce for the first time a detailed derivation of a useful quasi-steady “low-R m ” variant of the MHD approximation applicable for cases, such as with detonators, where the thermodynamic pressure arising from Joule heating dominates over magnetic forces. An additional purpose of this paper is to present a coupling mode using Multiple Program-Multiple Data (MPMD) message passing communication that allows the user to run 3D FE problems together with 2D and/or 3D MHD problems with the respective simulation domains coupled through a common circuit equation. The MPMD coupling capability is used here to model the dynamic coupling of a notional ferroelectric generator with an RP-87 exploding bridgewire detonator. The simulated bridgewire heats up and bursts under current generated by simulated depoling of the ferroelectric generator, as a demonstration of the MPMD capability.

42 ENGINEERING↗