Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EXHAUST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

H-Canyon Ventilation System Exhaust Tunnel Inspection at the Savannah River Site - 18052

The Department of Energy (DOE) H-Canyon Facility at the Savannah River Site (SRS) is operated by Savannah River Nuclear Solutions (SRNS). The Facility Structural Integrity Program (SIP) performs periodic visual inspections to confirm the component is capable of performing its safety function. This Program provides the process to document the conditions of safety related structural systems and components, their damage mechanisms, and recommend repairs if required before there is impact on the safety envelope. The H-Canyon Exhaust Tunnel is part of the H-Canyon Exhaust Ventilation System and is periodically inspected under the Structural Integrity Program. The Tunnel performs a Safety Class passive design feature function that is available 100% of the time. The Tunnel directs Canyon process air from the Canyon to the Sand Filter System. The radiological and chemical airborne activity coupled with the physical configuration of the tunnel precludes a manned entry into the tunnel. Tunnel inspections have been performed using cameras on a stick, referred to as pole cameras prior to CY2003. Since CY2003, five camera equipped crawlers have been used with varying levels of inspection success. With each successive crawler inspection, expectations have increased to perform tasks beyond visual examinations. The 2017 crawler performed the visual inspection but also included improvements on crawler performance, such as testing the use of wireless capability and remediation of crawler travel route, to the addition of stationary cameras and lighting at key locations. The latest 2017 crawler successfully traveled the entire length of the tunnel between the Canyon and Sand Filter System for the second time since development, thus providing key visual data for the integrity program [2]. In addition, several access ports were installed in 2017 following the removal of concrete core samples that allow for new visual inspection of the Canyon Crossover tunnel, thus providing information for an area that was generally inaccessible for monitoring. Planning for the 2019 crawler inspection is underway with the expectations to improve upon inspection cameras and also introduce mapping technologies such as LIDAR. The challenge to obtain meaningful data from the remote inspections of a 60+ year operating Canyon Exhaust tunnel continues to be a complex endeavor requiring close coordination of multiple organizations, adherence to Conduct of Operations, Radiological Safety, Worker Safety, etc. principles as well as alignment with Facility Safety Basis requirements. This paper discusses the continuing improvements in inspection techniques and the challenges associated these inspections. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Copper-Cobalt-Cerium Ternary Oxide as an Additive to a Conventional Platinum-Group-Metal Catalyst for Automotive Exhaust Catalysis

Recently, we reported on a ternary mixed-oxide catalyst that showed low-temperature CO oxidation activity under lean exhaust conditions without inhibition by hydrocarbons such as propene. However, the hydrocarbon oxidation activity of this Cu–Co–Ce (CCC) catalyst cannot be considered as a stand-alone solution to low-temperature automotive exhaust catalysis. To achieve both low-temperature oxidation of pollutants and a reduction in the total platinum-group-metal (PGM) content, we examined a 50 % physical mixture of traditional Pt/Al 2 O 3 and our CCC catalyst in two simulated exhaust protocols. Using this physical mixture, we were able to obtain equivalent or better hydrocarbon activity than the baseline Pt/Al 2 O 3 catalyst with half the total PGM content as well as increased sulfur tolerance for the CCC component of the mixture. Diffuse reflectance infrared Fourier transform spectroscopy data confirmed that despite exposure of sulfur-sensitive CCC to SO 2 , Cu + -carbonyl binding sites could still be seen if the catalyst was mixed with Pt/Al 2 O 3 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Unleaded Gasoline—Biofuel Blends on Exhaust Emissions

Biodiesels and biomass EtOH are currently considered the most applicable and essential biomass fuels. Furthermore, MeOH and BuOH are also attracting attention as alternatives. These fuel types can be used to reduce exhaust emissions from gasoline engines because they are renewable oxygenated bioresources. Three biofuel additives, namely, MeOH (10%, M10), EtOH (10%, E10), and BuOH (10%, B10) were used to compare the engine performance properties and exhaust gas emission levels upon combustion of mixed biomass fuels and pure petroleum fuel (clean unleaded gasoline, E0). The engine combustion temperature dropped by 4.32%, O{sub 2} emission increased by 6.67%, NO{sub x} emissions decreased by 13.46%, CO emission decreased by 44%, and hydrocarbon emissions fell by 29% if biomass fuels were used. Therefore, mixed biofuel additives and gasoline could substantially reduce engine exhaust emissions, including oxides of C and N, hydrocarbons, etc., because the biofuels contain higher oxygen contents that facilitate complete combustion.

09 BIOMASS FUELS↗

The removal of Zn2+, Pb2+, and As(V) ions by lime activated fly ash and valorization of the exhausted adsorbent

This study focuses on the use of raw fly ash (FA) and modified fly ash – activated by lime (MFA), as effective and low-cost adsorbents for the removal of heavy metals (Zn2+, Pb2+and As(V)), followed by the revalorization of the exhausted adsorbent. The granulometric, elemental analysis, point of zero charge (pHPZC), radiochemical and structural characterization were conducted using X-ray diffraction (XRD), Brunauer–Emmett–Teller (BET), scanning electron microscopy (SEM), Fourier transform infrared (FTIR) and gamma spectrometry techniques. The optimal conditions and key factors influencing the adsorption process were assessed using the response surface method (RSM). The adsorption capacity of the MFA adsorbent for Zn2+, Pb2+and As(V) removal, calculated by the Langmuir model, was found to be 33.13, 26.06, and 29.71 mg g−1, respectively. The kinetic and thermodynamic parameters indicated that the adsorption process is spontaneous and endothermic. Due to their low desorption potential of the exhausted adsorbents, their effective reuse was established to be feasible. For this reason, the valorization of this material as an additive in construction materials was thereafter studied, where testing its toxicity leaching (TCLP) as well as the mechanical properties of construction material containing exhausted MFA confirmed its safe use. Hence, this study points to a possible “two-in-one” reuse of coal ash, initially as an adsorbent and later as an additive in a construction material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Demonstration of Super-X divertor exhaust control for transient heat load management in compact fusion reactors

Nuclear fusion could offer clean, abundant energy. However, managing the power exhausted from the core fusion plasma towards the reactor wall remains a major challenge. This is compounded in emerging compact reactor designs promising more cost-effective pathways towards commercial fusion energy. Alternative Divertor Configurations (ADCs) are a potential solution. In this work, we demonstrate exhaust control in ADCs, employing a novel method to diagnose the neutral gas buffer, which shields the target. Our work on the Mega Ampere Spherical Tokamak Upgrade shows that ADCs tackle key risks and uncertainties for fusion energy. Their highly reduced sensitivity to perturbations enables active exhaust control in otherwise unfeasible situations and facilitates an increased passive absorption of transients, which would otherwise damage the divertor. We observe a strong decoupling of each divertor from other reactor regions, enabling near-independent control of the divertors and core plasma. Our work showcases the real-world benefits of ADCs for effective heat load management in fusion power reactors.

Imaging techniques↗

Impact of magnetic islands in the plasma edge on particle fueling and exhaust in the HSX and W7-X stellarators

The edge magnetic structure in the Helically Symmetric eXperiment (HSX) and Wendelstein 7X (W7-X) stellarators has been shown to have a significant impact on the particle fueling and exhaust of the plasma main species (hydrogen) as well as impurity helium. For HSX, the plasma sourcing to exhaust ratio, quantified by the effective and global particle confinement times τ p * and τ p , H , respectively, increases when a magnetic island chain is located in the plasma edge. The fueling efficiency is reduced by 25% when the plasma boundary is deformed by the magnetic islands. The X-point geometry also yields higher plasma temperatures in front of the main recycling region. When the island is moved radially inward, both τ p * and τ p decrease by 10 % – 25 % depending on plasma density. The τ p , H results rely heavily on EMC3-EIRENE modeling which confirms reduced fueling efficiency due to more rapid ionization in the outward shifted island position. These findings suggest that for a helically optimized system like HSX, the plasma fueling from the recycling source, as well as from active gas injection, can be controlled by the magnetic island chain in the plasma edge—which is a basic requirement for a divertor system. This process is also effective for the control of effective helium exhaust times, as τ p , H e * measured by perturbative gas puff experiments is reduced by up to 40% when the islands are shifted inwards. For Wendelstein 7-X, a similar reduction of τ p , H e * was inferred when magnetic islands were moved from the far plasma edge into the confined plasma region. Finally, however, the effective confinement features of H as the main plasma species were not affected due to the non-optimal position of the magnetic islands with respect to the highly localized ionization domain during the limiter startup campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exhaust Gas Recirculation Cooler Fouling in Diesel Applications: Fundamental Studies Deposit Properties and Microstructure

This paper reports on the results of experimental efforts aimed at improving the understanding of the mechanisms and conditions at play in the fouling of EGR coolers. An experimental apparatus was constructed to utilize simplified surrogate heat exchanger tubes in lieu of full-size heat exchangers. The use of these surrogate tubes allowed removal of the tubes after exposure to engine exhaust for study of the deposit layer and its properties. The exhaust used for fouling the surrogate tubes was produced using a modern medium-duty diesel engine fueled with both ultra-low sulfur diesel and biodiesel blends. At long exposure times, no significant difference in the fouling rate was observed between fuel types and HC levels. Surface coatings for the tubes were also evaluated to determine their impact on deposit growth. No surface treatment or coating produced a reduction in the fouling rate or any evidence of deposit removal. In addition, microstructural analysis of the fouling layers was performed using optical and electron microscopy in order to better understand the deposition mechanism. The experimental results are consistent with thermophoretic deposition for deposit formation, and van der Waals attraction between the deposit surface and exhaust-borne particulate.

EGR↗

Tritium Aspects of Fueling and Exhaust Pumping in Magnetic Fusion Energy

Magnetically confined fusion plasmas generate energy from deuterium-tritium (DT) fusion reactions that produce energetic 3.5 MeV alpha particles and 14 MeV neutrons. Since the DT fusion reaction rate is a strong function of plasma density, an efficient fueling source is needed to maintain high plasma density in such systems. Energetic ions in fusion plasmas are able to escape the confining magnetic fields at a much higher rate than the fusion reactions occur, thus dictating the fueling rate needed. These lost ions become neutralized and need to be pumped away as exhaust gas to be reinjected into the plasma as fuel atoms.The technology to fuel and pump fusion plasmas has to be inherently compatible with the tritium fuel. An ideal holistic solution would couple the pumping and fueling such that the pump exhaust is directly fed back into pellet formation without including impurity gases. This would greatly reduce the processing needs for the exhaust. Concepts to accomplish this are discussed along with the fueling and pumping needs for a DT fusion reactor.

Baylor, Larry↗

First field test of a novel optical gas analyser in the exhaust of Wendelstein 7-X

A novel optical gas analyser, designed for isotope-resolved exhaust composition measurement, was field-tested at Wendelstein 7-X (W7-X) to validate its laboratory-proven concept under operational fusion experiment conditions. The system, Optix, comprises a cold cathode remote plasma generator and a high-resolution Fabry–Perot spectrometer and was deployed in the exhaust line of W7-X during the OP2.3 campaign. The injection of 3 He and 4 He for minority ion-cyclotron heating provided a test case for helium isotope discrimination. Despite limitations due to background gas and low partial pressures of the target species, isotope-resolved spectral signatures were successfully observed, demonstrating the fundamental viability of the Optix approach. Additionally, the spectrometer was evaluated for plasma emission measurements from both core and edge sightlines. While helium line emission was detectable, interpretation was hindered by complex background signals, highlighting the benefits of controlled remote plasma generators for spectroscopy. This first deployment provides critical insight into pressure requirements, spectral resolution, and operational constraints, informing future applications of optical exhaust diagnostics in fusion devices.

magnetic confinement fusion↗

Co-Optimization Scheme for Hybrid Electric Vehicles Powertrain and Exhaust Emission Control System Using Future Speed Prediction

Hybrid electric vehicles (HEVs) have been an effective solution for improved vehicle fuel efficiency and reduced emission pollution. In this paper, a co-optimization scheme is proposed to optimize fuel efficiency for HEVs. Here, the proposed optimization scheme uses obtainable future speed prediction as the basis to optimally tune control parameters for the existing powertrain control system. The ramp-up time of the catalyst temperature to reach its light-off level in the exhaust emission system is also considered as an additional optimization constraint to reduce emission. The Toyota Prius Hybrid Simulink model which is an integrated model for a powertrain and exhaust emission system is validated using real data from several real driving cycle scenarios. Then, to simplify the formulation of the proposed algorithm, the model for the optimization for powertrain and exhaust emission systems is represented by a set of equivalent neural network (NN) models learned using the data generated from the well-validated Toyota Prius Hybrid Simulink model. Using NN models, a co-optimization algorithm is established that provides an optimal tuning of some fuel-sensitive powertrain control parameters using future speed prediction, leading to a novel co-optimization algorithm, achieving on average a further 9.22% fuel savings for the Toyota Prius Hybrid Simulink model.

33 ADVANCED PROPULSION SYSTEMS↗

Heat Exchanger Design Optimization for Mitigation of Diesel Engine Exhaust Fouling

Abstract The design optimization of a diesel exhaust-coupled heat and mass exchanger that drives a 2.71 kW cooling capacity absorption heat pump is presented in this study. Fouling layer thermal resistance and pressure drops from single-tube experiments are used to develop a thermodynamic, heat transfer, and pressure drop model for the exhaust-coupled desorber. A parametric study is performed to select a desorber design that meets system performance while minimizing footprint. Experimental heat duties and pressure drops are within 10% and 3%, respectively, of the model predictions. Thus, large data sets from single-tube experiments with representative geometries are successful in accounting for fouling effects at the component level. Desorber design optimization based on this approach ensures continued heat pump performance after fouling. This study, along with the single-tube experiments, presents a systematic approach to design exhaust-coupled heat exchangers while considering the effects of fouling. These results are applicable for a wide range of waste-heat recovery applications, and this method can be extended to different geometries and operating conditions.

Energy & Fuels↗

Assessment of the 3420 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The Pacific Northwest National Laboratory (PNNL) 3420 Building, which is part of the Physical Sciences Facility (PSF), houses radiological capabilities that results in the requirement that emissions monitoring must be conducted for potential radionuclides in the exhaust air discharge of this building. The air monitoring system is required to conform to Title 40 of the Code of Federal Regulations part 61 (40 CFR 61) Subpart H, which in turns requires a sampling probe in the exhaust stream to conform to the criteria of American National Standards Institute / Health Physics Society (ANSI/HPS) N13.1-2011, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. To support the air emissions permit for the 3420 Building on the PNNL campus, stack testing that used computational fluid dynamics (CFD) modeling as a surrogate stack and verification tests of velocity uniformity and flow angle on the retrofitted facility stack was performed. The ANSI/HPS N13.1-2011 criteria for the air monitoring probe location are that velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%COV. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20°. The CFD modeling of the stack, as reported by Recknagle et al. (2018) demonstrated that the stack meets the criteria at the probe location. The velocity uniformity and flow angle results from the 3420 stack verification tests, performed in October 2020, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 1.4%COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20%COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack result of 2.1%COV when all four fans were operating. Additionally, the measured average flow angle at the 3420 stack monitor location was 15.5 degrees. Although this is higher than expected based on the CFD model, the result is =20 degrees, so the criterion is met. Based on these stack verification test results, the reconfigured 3420 Building filtered exhaust stack meets the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the CFD report (Recknagle et al., 2018) may require additional tests and additional analysis to determine compliance with the standard.

3420 Building↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 1

Washington River Protection Solutions (WRPS) conducted tests of four types of chemical cartridges for air-purifying respirators (APR) and powered air-purifying respirators (PAPR) to determine the period of time the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the Hanford AX tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing a cartridge service life. Testing is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing using vapors from a Hanford AX tank farm exhauster slipstream was conducted from August 25–27, 2017. Vapors from the exhauster slipstream were fed to two respirator cartridge test stands developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Four different cartridges were assessed. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using an APR cartridge test stand. Multipurpose PAPR cartridges—MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR57 (TL2) (3M Company, Maplewood, Minnesota)—also were tested over the same two days using a separate PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms during a Waste-Disturbing Event

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ Primary Exhauster for the Hanford AY-AZ tank farms. Unlike prior cartridge testing on the 702-AZ Primary Exhauster, the recent tests were performed during a waste-disturbing event. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from February 10–11, 2017, on a slipstream from the 702-AZ exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) and canisters (e.g., Summa) sampling were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multiscale Modeling of Corrosion and Oxidation Performance and Their Impact on High-temperature Fatigue of Automotive Exhaust Manifold Components

The persistent need to reducing automobile emissions has led to the wide adoption of turbocharger technology and engine downsizing, which results in a substantial raise in exhaust temperature, reaching as high as 950°C. Therefore, the material selection for exhaust manifolds and turbocharger housings becomes significantly challenging. The successful development of the multiscale models on oxidation and corrosion performance, and their impact on high-temperature fatigue will enable the acceleration of new, high-performance, heat-resistant alloy solutions and the reduction of time and cost in achieving a durable design. In this project, we developed and validated multiscale models that can accurately predict the corrosion and oxidation performance and their impact on high-temperature fatigue of high-temperature automotive exhaust manifold components. The capability of accurately predicting the corrosion/oxidation-fatigue damage can significantly reduce the time and cost of achieving a durable design. The models were used to guide the development of new high thermomechanical fatigue (TMF) performance alloys.

Li, Mei↗

Tests of a High Temperature Sample Conditioner for the Waste Treatment Plant LV-S2, LV S3, HV S3A and HV-S3B Exhaust Systems

Tests were performed to evaluate a sample conditioning unit for stack monitoring at Hanford Tank Waste Treatment and Immobilization Plant (WTP) exhaust stacks with elevated air temperatures. The LV-S2, LV-S3, HV-S3A and HV-S3B exhaust stacks are expected to have elevated air temperature and dew point. At these emission points, exhaust temperatures are too high to deliver the air sample directly to the required stack monitoring equipment. As a result, a sample conditioning system is considered to cool and dry the air prior to its delivery to the stack monitoring system. The method proposed for the sample conditioning is a dilution system that will introduce cooler, dry air to the air sample stream. This method of sample conditioning is meant to reduce the sample temperature while avoiding condensation of moisture in the sample stream. An additional constraint is that the ANSI/HPS N13.1-1999 standard states that at least 50% of the 10 µm aerodynamic diameter (AD) particles present in the stack free stream must be delivered to the sample collector. In other words, depositional loss of particles should be limited to 50% in the sampling, transport, and conditioning systems. Based on estimates of particle penetration through the LV-S3 sampling system, the diluter should perform with about 80% penetration or better to ensure that the total sampling system passes the 50% or greater penetration criterion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Bifunctional Pt/CeO 2 -Cu 1 /CeO 2 Catalyst System for Isooctane Oxidation under Fully Simulated Engine-Exhaust Condition: Eliminating the Inhibition by CO

Pt-based catalysts, because of their outstanding activity for hydrocarbon oxidation, are widely used in the engine-exhaust aftertreatment system to remove hydrocarbon emissions. However, the CO and NO x present in real engine exhausts compete with hydrocarbons for active Pt sites, and thus inhibit hydrocarbon oxidation. In this work, we evaluated the inhibition effects of CO and NO on isooctane oxidation over a Pt/CeO 2 catalyst under the simulated condition of the US DRIVE test protocol (S-GDI, stoichiometric gasoline direct injection). We also leveraged a low-cost single-atom Cu 1 /CeO 2 catalyst, which is highly active for low-temperature CO oxidation, to eliminate the inhibition effect of CO. Specifically, by physically mixing Cu 1 /CeO 2 and Pt/CeO 2 , all the CO is completely converted below 200 °C under simulated exhaust condition, which helps lower the isooctane oxidation temperature. However, the unconverted NO still strongly suppresses HC oxidation. Possible strategies to address the NO inhibitor were proposed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MARCUS ARM CN and CCN data reprocessed to remove ship exhaust influence

The data presented in this collection are the cloud condensation nuclei (CCN) and condensation nuclei (CN) from the MARCUS (Measurements of Aerosols, Radiation and CloUds over the Southern Oceans) campaign. This campaign involved the deployment of the ARM Mobile Facility aboard the RSV Aurora Australis between October 2017 and March 2018 during its summer season resupplying Australia’s Antarctic research stations from its port in Hobart, Australia. Routine processing undertaken by ARM does not remove platform exhaust associated with its deployment aboard ships. Consequently, the raw data were obtained and manually filtered to remove the influence of platform exhaust on the measurements by reviewing CCN, CN and BC data simultaneously and flagging all affected periods. Remaining data were then quality controlled for when instrument parameters were out of specification. CCN data are split into different streams for supersaturation settings before statistics for each hour being calculated. All data files contain NaN values for periods when data was removed for QC or exhaust reasons. Original raw data available at: Kulkarni, G. R., Flynn, C. and Koontz, A.: Atmospheric Radiation Measurement (ARM) user facility. 2017, updated hourly. Cloud Condensation Nuclei Particle Counter (AOSCCN100). 2017-10-29 to 2018-03-24, ARM Mobile Facility (MAR) Hobart, AUS to Antarctic Coast - resupply ship Aurora Australis; AMF2 (M1)., Atmospheric Radiation Measurement (ARM) user facility Data Center: Oak Ridge, Tennessee, USA [online] Available from: http://dx.doi.org/10.5439/1227964 (Accessed 9 November 2018), 2018. Kuang, C., Salwen, C., Boyer, M. and Singh, A.: Atmospheric Radiation Measurement (ARM) user facility. 2017, updated hourly. Condensation Particle Counter (AOSCPCF). 2017-10-29 to 2018-03-26, ARM Mobile Facility (MAR) Hobart, AUS to Antarctic Coast - resupply ship Aurora Australis; AMF2 (M1)., Atmospheric Radiation Measurement (ARM) user facility Data Center: Oak Ridge, Tennessee, USA [online] Available from: http://dx.doi.org/10.5439/1046184 (Accessed 9 November 2018), 2018.

54 ENVIRONMENTAL SCIENCES↗