Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dose Assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Comparison of atmospheric radionuclide dispersion models for a risk-informed consequence-driven advanced reactor licensing framework

Current nuclear facility emergency planning zones (EPZs) are based on outdated distance-based criteria, predating comprehensive dose and risk-informed frameworks. Recent advancements in simulation tools have permitted the development of site-specific, dose, and risk-based consequence-driven assessment frameworks. This study investigated the computation of advanced reactor (AR) EPZs using two atmospheric dispersion models: a straight-line Gaussian plume model (GPM) and a semi-Lagrangian Particle in Cell (PIC). Two case studies were conducted: (1) benchmarking the NRC SOARCA study for the Peach Bottom Nuclear Generating Station and (2) analyzing an advanced INL Heat Pipe Design A microreactor's end-of-cycle inventory. The dose criteria for both cases were 10 mSv at mean weather conditions and 50 mSv at 95th percentile weather conditions at 96 h post-release. Results demonstrated that GPM and PIC estimated similar mean peak dose levels for large boiling water reactors in the farfield case, placing EPZ limits beyond current regulations. For ARs with source terms remaining in the nearfield, PIC modeling without specific nearfield considerations could result in excessively high doses and inaccurate EPZ designations. PIC dispersion demonstrated an order of magnitude higher estimate of nearfield inhalation dose contribution when compared to GPM results. Furthermore, both models significantly reduced EPZ sizing within the nearfield. Thus, reductions in the AR source term may eliminate the need for a separate EPZ.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

A Phase 1 Dose-Escalation Trial of Radiation Therapy and Concurrent Cisplatin for Stage II and III Triple-Negative Breast Cancer

Patients with triple-negative breast cancer (TNBC) experience higher local-regional recurrence rates than those with luminal or HER2-positive tumors. This prospective, phase 1B trial was designed to assess the safety and to establish the maximum tolerated dose (MTD) of cisplatin with radiation therapy for women with early-stage TNBC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Benzo[a]pyrene (BaP) metabolites predominant in human plasma following escalating oral micro-dosing with [ 14 C]-BaP

Benzo[a]pyrene (BaP) is formed by incomplete combustion of organic materials (petroleum, coal, tobacco, etc.). BaP is designated by the International Agency for Research on Cancer as a group 1 known human carcinogen; a classification supported by numerous studies in preclinical models and epidemiology studies of exposed populations. Risk assessment relies on toxicokinetic and cancer studies in rodents at doses 5–6 orders of magnitude greater than average human uptake. Using a dose–response design at environmentally relevant concentrations, this study follows uptake, metabolism, and elimination of [ 14 C]-BaP in human plasma by employing UPLC - accelerator mass spectrometry (UPLC-AMS). Volunteers were administered 25, 50, 100, and 250 ng (2.7–27 nCi) of [ 14 C]-BaP (with interceding minimum 3-week washout periods) with quantification of parent [ 14 C]-BaP and metabolites in plasma measured over 48 h. [ 14 C]-BaP median T max was 30 min with C max and area under the curve (AUC) approximating dose-dependency. Marked inter-individual variability in plasma pharmacokinetics following a 250 ng dose was seen with 7 volunteers as measured by the C max (8.99 ± 7.08 ng × mL -1 ) and AUC0-48hr (68.6 ± 64.0 fg × hr -1 × mL -1 ). Approximately 3–6% of the [ 14 C] recovered (AUC 0-48 hr ) was parent compound, demonstrating extensive metabolism following oral dosing. Metabolite profiles showed that, even at the earliest time-point (30 min), a substantial percentage of [ 14 C] in plasma was polar BaP metabolites. The best fit modeling approach identified non-compartmental apparent volume of distribution of BaP as significantly increasing as a function of dose (p = 0.004). Bay region tetrols and dihydrodiols predominated, suggesting not only was there extensive first pass metabolism but also potentially bioactivation. AMS enables the study of environmental carcinogens in humans with de minimus risk, allowing for important testing and validation of physiologically based pharmacokinetic models derived from animal data, risk assessment, and the interpretation of data from high-risk occupationally exposed populations.

59 BASIC BIOLOGICAL SCIENCES↗

Monitoring Plan for the Idaho National Laboratory Remote Handled Low Level Waste Disposal Facility

This monitoring plan for Idaho National Laboratory’s Remote-Handled Low Level Waste Disposal Facility was developed to meet the requirements for monitoring low-level waste disposal facilities according to the U.S. Department of Energy (DOE) Order 435.1, “Radioactive Waste Management,” and the guidance provided in the associated technical standard “Disposal Authorization Statement and Tank Closure Documentation” (DOE-STD-5002-2017). The purpose of this monitoring plan is to document a monitoring strategy that includes (1) compliance monitoring activities to demonstrate compliance with regulatory standards/limits and (2) performance monitoring to build confidence the facility is performing as demonstrated in the facility performance assessment (PA) (DOE-ID 2018a), composite analysis (CA) (DOE ID 2012), and CA addendum (DOE-ID 2018b). The de minimus impact to the aquifer predicted by the PA suggests that aquifer compliance monitoring should be augmented with performance monitoring of the drainage course materials and sedimentary interbeds in the vadose zone beneath the facility to provide a more effective means of identifying performance deviations. The monitoring approach delineated in this document was informed by the systems evaluation of natural and engineered facility features presented in the PA, an assessment of aquifer baseline conditions (INL 2017d), the dose analysis conducted in support of the PA and CA, and monitoring data collected during the first four years of facility operations (baseline monitoring phase) (INL 2023b). This plan provides monitoring locations, sampling frequencies, and sampling methods; recommendations for data evaluation; and a description of the monitoring plan implementation. Collected data will be used to demonstrate facility compliance and to identify conditions that are not consistent with the key assumptions made by the PA and CA.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Influence of fluorescent dopants on the vat photopolymerization of acrylate-based plastic scintillators for application in neutron/gamma pulse shape discrimination

Plastic scintillators, a class of solid-state materials used for radiation detection, were additively manufactured with vat photopolymerization. The photopolymer resins consisted of a primary dopant and a secondary dopant dissolved in a bisphenol A ethoxylate diacrylate-based matrix. The absorptive dopants significantly influence important print parameters, for example, secondary dopants decrease the light penetration depth by a factor > 12×. The primary dopant 2,5-diphenyloxazole had minimal impact on the printing process even when loaded at 25 % by mass of the resin. Working curve measurements, which relate energy dose to cure depth, were performed as a function of feature size to further assess the influence of dopants. Photopatterns smaller than 150 µm width had apparent increases in critical energy dose compared to larger photopatterns, while all resins maintained printed features in line gratings with 50 µm of separation. Printed scintillator monoliths were compared to scintillators cast by traditional molding, demonstrating that the layer-by-layer printing process does not decrease scintillation response. In conclusion, a maximum light output of 31 % of a benchmark plastic scintillator (EJ-200) and successful pulse shape discrimination were achieved with 20 % by mass 2,5-diphenyloxazole as the primary dopant and 0.1 % by mass 9,9-dimethyl-2,7-distyrylfluorene as the secondary dopant in printed scintillator samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

E-Area Low-Level Waste Facility Inadvertent Human Intruder Limits and Doses in Support of the PA2022

This report documents the inadvertent human intruder (IHI) analysis for the E-Area Low-Level Waste Facility (ELLWF) at the Savannah River Site (SRS), near Aiken, South Carolina. This analysis supports the 2022 Performance Assessment for ELLWF, complying with the Department of Energy standard for operation of low-level waste disposal facilities (USDOE, 2017). The ELLWF is an operating waste disposal facility and is scheduled to continue accepting waste to 2065. One task of the 2022 Performance Assessment (PA) is to establish waste inventory limits for the various disposal units at ELLWF. This is done by modeling future contaminant release and transport through applicable pathways to human receptors, comparing predicted doses per disposed curie with applicable performance measures, to obtain inventory limits which will assure that doses to receptors do not exceed performance measures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of corrosion layer composition and thermal pretreatment on the radiolytic generation of molecular hydrogen from aluminum alloys

To fully evaluate the feasibility of extending the dry storage of aluminum-clad spent nuclear fuel (ASNF) in helium-backfilled cannisters, the amount of radiation-induced molecular hydrogen (H 2 ) generated and the impact of absorbed radiation dose on the ASNF corrosion layer composition must be accurately assessed. Here, in this study, we report a slowing in the rate of radiolytic H 2 generation for pre-corroded AA1100 and AA6061 aluminum alloy coupons irradiated to up to 53 MGy of absorbed cobalt-60 gamma dose. By exploring a variety of thermal pretreatment conditions for AA6061 coupons, we find that the “steady-state” yield of H 2 depends more on the aluminum alloy used than on the treatments applied prior to dry storage. Scanning electron microscopy and positron annihilation lifetime spectroscopy techniques also provided evidence for gamma radiation-induced defects in the corrosion layers of the investigated aluminum alloy coupons for high absorbed doses (~50 MGy), the consequences of which on cladding integrity and H 2 generation should be explored in future works.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

The impact of sampling scale: A comparison of methods for estimating external contaminant exposure in free-ranging wildlife

The impacts of contaminants on wildlife are dose dependent, and thus being able to track or predict exposure following contamination events is important for monitoring ecosystem health. However, the ability to track exposure in free-ranging wildlife is often severely limited. Consequently, researchers have predominantly relied on simple methods for estimating contaminant exposures in wildlife with little regard for spatial contaminant heterogeneity or an animal’s use of diverse habitats. We evaluated the influence sampling scale (i.e., how finely contaminant distribution and organism’s spatial use of the landscape is mapped) has on (1) realism and (2) conservativeness of exposure estimates. To do this, we monitored the actual exposure of wild boar (Sus scrofa) in Fukushima, Japan to radioactive contamination using GPS27 coupled contaminant monitors placed on individual animals. We compared empirical exposures to estimates generated by combining varying amounts of information about an individual boar’s location and/or movement, with the distribution of contamination on the landscape. Here we found that the most realistic exposure estimates were produced when finer-scale contaminant distribution surveys (e.g., airborne surveys) were combined with more accurate estimates of an individual’s space use (e.g., home ranges or core areas). Importantly, estimates of exposure based on single point surveys at a trap site (a simple method commonly used in the literature), did not correlate with actual exposure rates, suggesting dose-effects studies using this method may result in spurious conclusions. These results suggest that researchers seeking realistic estimates of exposure, such as in dose-effect studies, should ensure they have adequately accounted for fine-scale contaminant distribution patterns and areas of higher use by study organisms. However, conservative estimates of exposure i.e., intentionally over-predicting exposure as is done in initial tiers of ecological risk analyses) were not as scale sensitive and could be achieved with a single known location and coarse contaminant distribution maps.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Controlled electrochemical nutrient delivery to enhance marine primary productivity

Oceanic photosynthesis contributes to approximately half of the Earth’s net annual primary productivity. Marine photosynthetic productivity has a high degree of heterogeneity due to spatial and temporal co-limitations of light, temperature, and/or nutrients. Across coastal, near-shore, and open ocean regions, insufficient concentrations of key nutrients (e.g., N, P, Fe) can limit primary productivity. Although studies have shown a significant increase in primary productivity with the addition of low doses of trace nutrients, a sustainable approach to reliably deliver and maintain low doses of nutrients and ensure their bioavailability, remains a challenge. Chemical nutrient addition has relied on the use of chelating agents to ensure nutrient bioavailability, but synthetic chelators are persistent environmental pollutants. In this study, we demonstrate for the first time the use of a controlled electrochemical nutrient delivery (CEND) approach to accelerate the growth of phytoplankton without the need for such chelators. Our study uses commercial stainless-steel electrodes to deliver low concentrations of iron to enhance growth rates in the microalga Picochlorum celeri TG2. To demonstrate the process control offered by the CEND method, we evaluate iron delivery as a function of pulse time, pulse frequency, and rest time between pulses. Our data show that at the same total Fe dose of 163 ppb, electrochemical iron delivery can achieve 9.54 ± 0.58 mg biomass/µg Fe, which is comparable to 9.14 ± 0.17 mg biomass/µg Fe achieved with chemical iron additions that include the synthetic chelating agent ethylenediaminetetraacetic acid (EDTA). Further, when different total iron doses (163 ppb, 325 ppb, and 650 ppb) were delivered over 72 h using CEND, biomass yield per iron dose was higher at lower doses: 9.54 ± 0.58 mg biomass/µg Fe at 163 ppb vs. 4.32 ± 0.32 mg biomass/µg Fe at 650 ppb. This highlights the benefits of CEND in delivering frequent and low doses of nutrients for improved process efficiency. Preliminary assessments show both lower cost and reduced greenhouse gas emissions from electrochemical over chemical iron additions with EDTA. The CEND approach opens new pathways to enhance marine primary productivity, without the unintended environmental impacts of synthetic chelators.

analytical chemistry↗

Is Mini Beam Ready for Human Trials? Results of Randomized Study of Treating De-Novo Brain Tumors in Canines Using Linear Accelerator Generated Mini Beams

The main challenge in treating malignant brain neoplasms lies in eradicating the tumor while minimizing treatmentrelated damage. Conventional radiation treatments are associated with considerable side effects. Synchrotron generated micro-beam radiation (SMBRT) has shown to preserve brain architecture while killing tumor cells, however physical characteristics and limited facility access restrict its use. We have created a new clinical device which produces mini beams on a linear accelerator, to provide a new type of treatment called mini-beam radiation therapy (MBRT). The objective of this study is to compare the treatment outcomes of linear accelerator based MBRT versus standard radiation treatment (SRT), to evaluate the tumor response and the treatment-related changes in the normal brain with respect to each treatment type. Pet dogs with de-novo brain tumors were accrued for treatment. Dogs were randomized between standard fractionated stereotactic (9 Gy in 3 fractions) radiation treatment vs. a single fraction of MBRT (26 Gy mean dose). Dogs were monitored after treatment for clinical assessment and imaging. When the dogs were euthanized, a veterinary pathologist assessed the radiation changes and tumor response. We accrued 16 dogs, 8 dogs in each treatment arm. In the MBRT arm, 71% dogs achieved complete pathological remission. The radiation-related changes were all confined to the target region. Structural damage was not observed in the beam path outside of the target region. In contrast, none of the dogs in control group achieved remission and the treatment related damage was more extensive. Therapeutic superiority was observed with MBRT, including both tumor control and the normal structural preservation. The MBRT findings are suggestive of an immune related mechanism which is absent in standard treatment. These findings together with the widespread availability of clinical linear accelerators make MBRT a promising research topic to explore further treatment and clinical trial opportunities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Degradation of Poly- and Perfluoroalkyl Substances (PFASs) in Water via High Power, Energy-Efficient Electron Beam Accelerator

The goal of this study was to evaluate the overall effectiveness of e-beam treatment in the degradation of PFASs in water treatment. This included validation of the expected process flows and required electron beam doses, with the first year dedicated to experimentally assessing the optimal electron beam treatment parameters required to decompose the contaminants of concern. In the second year, FNAL’s technical efforts focused on evaluating three different accelerator technologies that could be implemented in the treatment process of PFASs.

43 PARTICLE ACCELERATORS↗

Godiva-IV Dosimetry Exercise 2022 Preliminary Results

Integral Experiment Request (IER) 538 is part of a series of dose characterization and nuclear accident dosimetry (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). This is the second NAD exercise using the Godiva-IV critical assembly and the third NAD exercise overall. The participating laboratories provided their own dosimeters that were mounted on the Lawrence Livermore National Laboratory (LLNL) BOttle Manikin ABsorption (BOMAB) phantoms and aluminum plates. The BOMABs and plates were placed at two, three, and four meters away from the center of Godiva. Alongside the NADs, there was a LLNL Passive Neutron Spectrometer (PNS), Atomic Weapons Establishment (AWE) PNS, and Y-12 Sphere present to measure the neutron dose from Godiva. Two irradiations were conducted to test the NAD performance from each laboratory and assesses their performance to the DOE-STD-1098-2017 part 515 criteria. Neutron and gamma doses were measured prior to this exercise. This work presents a model for the neutron and gamma dose respectively to serve as the reference value. A code written in C/C++/ROOT was used to fit the measured neutron and gamma dose with the new models. It was assumed that the neutron and gamma doses are proportional to the change in temperature of Godiva after a burst irradiation. Uncertainties for the reference values were calculated using error propagation of the model’s parameters. Preliminary results (within twenty-four hours) and final results were compared for each laboratory. On average of all the participating laboratories, 32% of neutron doses and 78% of gamma doses were outside the DOE standards. One laboratory did not report their dose readings and were not included in this average. There is a bias for a lower neutron dose and a higher gamma dose based on the distribution of results. In comparison with the past Godiva-IV NAD exercise, there is an improvement in neutron dose readings by 20%.

BOttle Manikin ABsorption (BOMAB)↗

Radiation-induced bowing of SiC/SiC composites under neutron flux gradients—integral experimental data for model validation

Here, the radiation-induced swelling of SiC and its composites, including strong dependencies on temperature and dose, can drive significant lateral bowing in the presence of temperature and/or dose gradients. In recent years, simulations have been performed to assess the extent of bowing in SiC composite light-water reactor (LWR) fuel cladding and boiling water reactor (BWR) channel boxes. However, to date, no integral experimental data exist to validate these models. This work provides the first experimental bowing evaluation of three ∼380 mm long SiC composite specimens irradiated under varying neutron dose gradients (∼50°C–60°C, 0.03–0.06 dpa): two tubes (∼9.8 mm diameter) and a miniature BWR channel box (∼30 mm square). The measured radiation-induced length swelling (∼0.3%–0.7% linear) was consistently 10%–21% higher than values obtained from 3D finite element structural analyses with inputs from 3D radiation transport calculations. This discrepancy could be at least partially explained by differences in dose rate (∼10 -8 dpa/s) compared to the literature data (∼10-6 dpa/s) used to establish the dose-to-swelling correlations in the model. Nevertheless, the modeled bowing magnitudes (<2 mm) obtained from finite element analyses and simple analytical equations were within the bounds of the experimental measurements for all specimens. With improved confidence in the ability to predict the structural response and measure the macroscopic deformations, future experiments will target transient bowing under neutron flux gradients at representative LWR temperatures and assess whether grid spacers can mitigate the tens of millimeters of bowing that would otherwise be expected in ∼4 m long LWR components.

bowing↗

The Clinical Cell-Cycle Risk (CCR) score Is Associated With Metastasis After Radiation Therapy and Provides Guidance on When to Forgo Combined Androgen Deprivation Therapy With Dose-Escalated Radiation

The clinical cell-cycle risk (CCR) score, which combines the University of California, San Francisco's Cancer of the Prostate Risk Assessment (CAPRA) and the cell cycle progression (CCP) molecular score, has been validated to be prognostic of disease progression for men with prostate cancer. This study evaluated the ability of the CCR score to prognosticate the risk of metastasis in men receiving dose-escalated radiation therapy (RT) with or without androgen deprivation therapy (ADT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of 63 MeV proton irradiation on the performance of MWIR InGaAs/InAsSb nBn photodetectors

An investigation into the effects of 63 MeV proton irradiation on high-sensitivity mid-wave infrared InGaAs/InAsSb nBn devices is performed. Three different structures with various absorber region doping profiles are irradiated and characterized to assess their impact on performance degradation. Minority carrier lifetime is measured using time-resolved photoluminescence and lifetime damage factors are assessed. The majority carrier concentration is determined via capacitance–voltage measurements and dopant introduction rates are calculated. An analysis of dark current density is performed using these material parameters, revealing a reduction in mobility with proton fluence and the emergence of a proton-induced trap energy level. Quantum efficiency is calculated at each proton fluence, and quantum efficiency damage factors show that the graded doping structure exhibits the least reduction of quantum efficiency with dose, attributed to its effective mobility enhancement. Conclusively, detector sensitivity, assessed via shot-noise limited noise-equivalent irradiance, shows that the graded doping structure is the least susceptible to high energy proton irradiation-induced performance degradation.

Physics↗

E-Area Low-Level Waste Facility Inadvertent Human Intruder Limits and Doses in Support of the PA2022

This report documents the inadvertent human intruder (IHI) analysis for the E-Area Low-Level Waste Facility (ELLWF) at the Savannah River Site (SRS), near Aiken, South Carolina. This analysis supports the revised ELLWF Performance Assessment (PA), complying with the Department of Energy standard for operation of low-level waste disposal facilities (USDOE, 2017). The ELLWF is an operating waste disposal facility and is scheduled to continue accepting waste to 2065. One task of the revised PA is to establish waste inventory limits for the various disposal units at ELLWF. This is done by modeling future contaminant release and transport through applicable pathways to human receptors, comparing predicted doses per disposed curie with applicable performance measures, to obtain inventory limits which will assure that doses to receptors do not exceed performance measures. This report documents results of modeling future doses to one class of receptor, the inadvertent human intruder. It is assumed that after site closure, public knowledge of the site is lost, and IHIs will engage in activities on the ELLWF that will disrupt the closure cap, causing dose to the IHI. Following USDOE (2017), six different stylized exposure scenarios are considered, simulating activities by an IHI which could result in a radiological dose. The six scenarios are: • Acute – Basement Construction: IHI constructs a basement and encounters waste during excavation which is inadvertently mixed with clean soil and diluted. • Acute – Well Drilling: IHI drills a water well through waste and is exposed to drill cuttings mixed with clean soil that are brought to the surface. • Acute – Discovery: IHI begins constructing a basement but stops when encountering the riprap in the final closure cap and is exposed to photon radiation from unexcavated material residing in the undisturbed waste zone. • Chronic – Agriculture: Resident IHI is exposed to waste that was excavated for basement construction and mixed with native soil in the intruder’s vegetable garden. • Chronic – Post-Drilling: Resident IHI is exposed to waste from drill cuttings mixed with native soil and scattered in the garden area. • Chronic – Residential: Resident IHI is exposed to external radiation while in home located above waste with shielding provided by the concrete basement floor and any soil or engineered material remaining between the basement and waste. Dose calculations are performed using the SRNL Dose Toolkit (Aleman, 2023), following the approach of Smith et al (2019). Calculations are performed separately for 27 of the 33 disposal units (DUs) at ELLWF and are radionuclide specific. The results of the IHI analysis include: • Dose Factors: mrem per disposed curie (acute) and mrem/yr per disposed curie (chronic) for each parent radionuclide, for each DU. • Inventory Limits: in curies, for each parent radionuclide, for each DU. • Estimated Dose to IHI: mrem (acute) and mrem/yr (chronic), for each DU, given its projected closure inventory without inventory biases applied. Most DU-specific IHI inventory limits are in the range of 10 3 to 10 7 curies per nuclide. The lowest inventory limits are associated with gamma-emitters such as Sn-126, Ra-226, Th-232, and Cm-248. Radionuclides with short half-lives such as Pu-241, and nuclides which are pure beta emitters or which decay by electron capture, such as Ni-59 and Ni-63, have the highest limits. For the 27 evaluated DUs, predicted IHI doses are shown in Table ES-1. The maximum acute dose is 1.18 mrem, at ST23, much less than the DOE performance measure of 500 mrem (USDOE, 2017). The highest chronic dose is 37.2 mrem/yr at ST02, below the DOE performance measure of 100 mrem/yr. Also shown are estimated inventory sums of fractions (SOFs) at closure in 2065, for groundwater (GW) and IHI pathways. For each DU, the inventory is constrained by the GW pathway. For most DUs, the IHI SOFs are approximately 1000 times lower than the GW SOF values, and the IHI pathway does not drive risk for any disposal unit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vadose and Saturated Zone Flow and Transport Calculations for the Active Trenches of the Low-Level Burial Grounds, Hanford Site, Washington

The purpose of the fate and transport modeling described in this environmental calculation file (ECF) is to evaluate the impacts to groundwater associated with waste disposal operations at Mixed Waste Low-Level Burial Ground (LLBG) Trenches 31 and 34 to satisfy requirements in DOE O 435.1, Radioactive Waste Management. The model integrates the flow and transport in the vadose zone beneath the active trenches with the saturated zone downgradient of the trenches to predict the radionuclide concentration at the point of assessment (POA). DOE M 435.1-1, Radioactive Waste Management Manual, defines the POA as the point of highest projected dose or concentration beyond a 100 m (328 ft) buffer zone surrounding the disposed waste. The modeling is conducted in accordance with the DOE G 435.1, Implementation Guide for Use with DOE M 435.1-1, performance assessment (PA) guidelines. The modeling involves evaluation of the groundwater concentrations and radionuclide arrival times during the 1,000-year compliance and 10,000-year sensitivity-uncertainty periods per DOE O 435.1 and DOE M 435.1. This analysis does not consider radionuclide release during facility operations, only the post-closure impacts of the radionuclides to the environment. The evaluation of potential radiological dose to groundwater receptors caused by releases from a closed facility containing radioactive waste typically includes the following: (1) Release of radionuclides from that facility (2) Transport of those radionuclides through the environment, and (3) Exposure to humans to environmental concentration levels of those radionuclides The fate and transport three-dimensional (3D) model analysis involves the post-closure impacts to the environment of the technetium-99, iodone-129, and uranium (all isotopes in the waste). The residual inventory estimates include several radionuclides, but technetium-99 is typically responsible for almost all of the beta-gamma dose equivalent associated with groundwater (water resources) protection per 40 CFR 141, “National Primary Drinking Water Regulations” (e.g., see the results in WCH-520, Performance Assessment of Environmental Restoration Disposal Facility, Hanford Site, Washington; hereinafter referred to as the ERDF PA), and iodone-129 can also be a significant dose contributor for some waste (e.g., RPP-RPT-59958, Performance Assessment for the Integrated Disposal Facility, Hanford Site, Washington; hereinafter referred to as the IDF PA). Uranium does not typically factor significantly into the impacts to groundwater, even during the 10,000-year sensitivity-uncertainty period, but always remains of interest as a contaminant. This ECF does not address vadose and saturated zone modeling for Trench 94 of the 200 East Area LLBG. Current information confirms the validity of the low corrosion rate of the naval reactor plant carbon steel (HY-80), and the even lower corrosion rate of the nickel-iron-chromium alloy reactor vessel (Inconel Alloy 600) presented in DOE/EIS-0259, Final Environmental Impact Statement on the Disposal of Decommissioned, Defueled Cruiser, Ohio Class, and Los Angeles Class Naval Reactor Plants. Based on these low corrosion rates, the time to breach the reactor vessel to allow release of radionuclides from the activated metal of the reactor vessel internal structure is at least 10,000 years. This time to breach precludes the need to evaluate the vadose and saturated zone transport of contaminants released from the reactor compartment disposal packages in the 200 East Area LLBGs PA (CP-63826, Waste Release Model Package Report for the Active Trenches of the Low-Level Burial Grounds, Hanford Site, Washington).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Embedded acoustic sensing and monitoring techniques for small modular reactors

The goal of this project was to study the applicability of specific innovative instrumentation techniques for assessing parameters needed for safe small modular reactor operation and safeguarding of nuclear material. Small modular reactor core designs are currently being developed to provide energy more effectively and efficiently than in the past because they can be built as modules at fabrication sites and then transported to a power-producing facility. However, these modules and/or the final core will often be sealed and not accessible again until disposal. Instead of instruments that access the core directly, during and after operation, to monitor flux/dose and structural integrity, as current power plants use, new sensors need to be designed that can be built into the reactor initially to determine operating history, structural integrity through operation of the system, and nuclear material accountancy after shutdown and before disposition of the core. Embedded sensors already exist that can provide neutron flux, gamma dose, and temperatures, but techniques to expand upon these for assessing structural health and material inventory in the system over time need to be developed. Structural health assessments include the detection and imaging of cracks in the components that could eventually cause radioactive fission products to be released.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗