Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Diffuse interface methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

788 records · Page 11

A method for battery activation

A technique to activate nickel cadmium batteries is described. The method shortened the time required for activation, eliminated the temperature rise in the batteries, and produced a voltage on the discharge that was better than when the C/20 was run for 48 hours during tests. Various methods of activation are described and evaluated. Results of alternate conditioning charge schemes are presented along with voltage/temperature characteristics for multiple level nickel cadmium battery chargers.

Halpert, G.

Method for implant and anneal for high voltage field effect transistors

In an example, the present invention provides a method of forming a semiconductor device on a gallium and nitrogen containing material. The method includes providing a substrate member comprising a surface region, the substrate member comprising a gallium and nitrogen bearing material. The method includes causing an implanted species to electrically activate the implant profile while removing one or more crystalline damage from the epitaxial material to change the amorphous state to a single crystalline state, and thereby creating a substantially electrically activated crystalline material.

Shealy, James R.

A Survey of Methods for Measuring Thermally Induced Distortions of Test Articles Undergoing Solar Thermal Vacuum Test

Various methods of measuring the small thermally induced distortions experienced either by various points on the space vehicles or by deviations of surfaces from a known shape during solar thermal vacuum tests are examined. State-of-the-art application of both photographic and real time observation are discussed. The relative merits of each of the methods are compared and evaluated in their applications to different types of test articles and situations. Magnitudes of thermally induced distortions which may be expected to be routinely measurable by the various methods are presented and compared.

R D Rempt

Kryptonate Hydrogen Detection System (Final Report)

A prototype model of a multipurpose instrument which demonstrates the applicability of the Kryptonate® technique for detecting hydrogen gas was developed. This report describes the construction of the instrument and presents a laboratory evaluation of its performance. Performance was excellent. The instrument was designed to detect hydrogen in air at concentrations of 0-3% by volume, and to detect hydrogen in nitrogen or other inert gas at concentrations of 0-10% by volume. Other detection levels (both higher and lower) could be set if required. Ultimate response times can be made of the order of 0.5 seconds. The instrument is an all solid state device operating from 120V 60 Hz power source. The instrument has been designed to enable modifications to be made with a minimum amount of difficulty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Composite battery separator

A composite battery separator comprises a support element (10) having an open pore structure such as a ribbed lattice and at least one liquid permeable sheet (20,22) to distribute the compressive force evenly onto the surfaces of the layers (24, 26) of negative active material and positive active material. In a non-flooded battery cell the compressible, porous material (18), such as a glass mat which absorbs the electrolyte, is compressed into a major portion of the pores or openings (16) in the support element. The unfilled pores in the material (18) form a gas diffusion path as the channels (41) formed between adjacent ribs in the lattice element (30,36). Facing two lattice elements (30, 31) with acute angled cross-ribs (34, 38) facing each other prevents the elements from interlocking and distorting a porous, separator (42) disposed between the lattice elements.

Edwards, Dean B.

Handbook of Molecular Beam Epitaxy of Oxide Materials: Epitaxial Complex Oxide Growth on Semiconductors

This chapter covers the epitaxy of complex oxides on common inorganic semiconductors. The chapter opens with an introduction, motivating the subject and highlighting key general challenges (Section 6.1). We then proceed to describe the general steps of the growth procedure in Section 6.2, which concludes with an overall discussion about trade-offs and expectation management, with an emphasis on the oxide–semiconductor interface. From there, the text describes oxide growth on the common semiconductors, starting with silicon (Section 6.3), where surface reactions and oxidation are the most challenging aspects. Oxide epitaxy on germanium is described in Section 6.4, which is a less challenging oxide growth scheme on semiconductors. Section 6.5 describes oxide epitaxy on gallium arsenide, one of the more challenging schemes, where interface stability and surface preparation pose key challenges. Finally, in Section 6.6, oxide epitaxy on gallium nitride is described, where the lattice mismatch takes the stage as the key challenge. Altogether, this chapter aims to provide the reader with the practical knowledge, tactics and strategies for oxide epitaxy on semiconductors.

Demkov, Alexander A [The University of Texas at Au

Methods for Validation of Random Uncertainty Estimates and Their Applications to Ozone Profiles From Limb-Viewing Satellite Instruments

For satellite measurements of atmospheric composition, the random uncertainty estimates provided by retrieval algorithms might be imperfect due to various approximations used in the retrievals or the presence of unknown error sources. This paper presents an overview of the methods used for the validation of random uncertainty estimates. All methods discussed in this study are categorized, and assumptions and limitations of each method are discussed. This overview evaluates these methods in application to ozone profile measurements from limb and occultation satellite instruments and provides practical illustrations of random uncertainty validation.

Viktoria F Sofieva

A hybrid Monte Carlo-deterministic second moment method with efficient variance reduction

In this work, we present a hybrid method that combines Monte Carlo with deterministic finite element methods to solve a linear Boltzmann transport equation. Our hybrid method runs orders of magnitude faster than Monte Carlo, without sacrificing accuracy, for a proxy problem from radiative transfer that contains both optically-thick and optically-thin material. We believe that this is the first demonstration of a hybrid Second Moment Method in more than one spatial dimension, the first to consider more than one material, and the first to use variance reduction. Our variance reduction approach arises from an asymptotic analysis in which we show that the magnitude of the scattering source grows without bound. We transform the problem to compute the deviation of the radiation intensity from isotropy. The magnitude of the source in the transformed problem is bounded, and the quality of the hybrid method solution is dramatically improved by a substantial reduction in the variance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Evaluation of Various Methods for Determining Bulk Compositions of Chondrules and Other Objects in Petrographic Thin Sections

Studies of many objects in petrographic thin section, such as melt inclusions in igneous rocks, chondrules and Ca-Al rich inclusions in chondritic meteorites, or clasts in lunar and other breccias, require or can benefit from knowledge of their bulk compositions. Given the scarcity of these materials, the reluctance of curators to provide more abundant material, and the extreme difficulty of cleanly separating such objects from their rock matrices, geochemical and cosmochemical studies need the ability to determine their bulk compositions from in situ methods, such as defocused beam analysis, or quantitative chemical mapping by electron beam methods.

Daniel Kent Ross

Method of making thin films of sodium fluorides and their derivatives by ALD

A method of making thin films of sodium fluorides and their derivatives by atomic layer deposition (“ALD”). A sodium precursor is exposed to a substrate in an ALD reactor. The sodium precursor is purged, leaving the substrate with a sodium intermediate bound thereon. A fluorine precursor is exposed to the bound sodium intermediate in the ALD reactor. The fluorine precursor is purged and a sodium fluoride film is formed on the substrate.

Mane, Anil U.

Visualizing Millisecond Atomic Dynamics of Nanocrystals in Liquid

Atomic structures of nanomaterials are inherently dynamic and continuously reshaped through interactions with chemical species and external stimuli. Such dynamics are further amplified as the size and dimensionality of nanomaterials decrease. Despite advances in analytical methods, it remains challenging to capture the structural dynamics of nanomaterials in reactive environments with both atomic spatial resolution and commensurate temporal resolution. Here, in this study, we directly visualize atomic-scale dynamics of gold (Au) nanocrystals in reactive liquid environments with millisecond-speed liquid-cell electron microscopy (EM) and deep-learning denoising. We uncover reversible fluctuations in the local crystallinity of Au nanocrystals dependent on the surrounding chemical environment. These transient fluctuations, driven by interactions at nanocrystal–liquid interfaces, critically influence the dissolution kinetics and grain boundary relaxation. By overcoming the spatiotemporal limitations in conventional liquid-cell EM, our findings provide insights into how transient nanoscale structures dictate the stability and reactivity of nanomaterials.

Kang, Sungsu [University of Chicago, IL (United St

Battery Cell Balancing System and Method

A battery cell balancing system is operable to utilize a relatively small number of transformers interconnected with a battery having a plurality of battery cells to selectively charge the battery cells. Windings of the transformers are simultaneously driven with a plurality of waveforms whereupon selected battery cells or groups of cells are selected and charged. A transformer drive circuit is operable to selectively vary the waveforms to thereby vary a weighted voltage associated with each of the battery cells.

Davies, Francis J.

Comparison and Application of Battery Modeling Methods for Conceptual Electric Aircraft

Growing interest in design and optimization of electrified aircraft propulsion concepts prompts the need for accurate, flexible, and efficient methods to model battery systems. Presented in this paper are three battery modeling methods that have been used at NASA’s Glenn Research Center, each representing different mathematical or electrical approaches. Thévenin equivalent circuit, normalization, and curve-fitting methods are compared against battery cell test data for the X-57 Maxwell electric aircraft technology demonstrator. The methods are then applied in a simple multidisciplinary optimization context using NASA’s Six-Passenger Electric Quadrotor concept to determine their applicability and performance. The normalization method achieves the highest accuracy for steady and unsteady discharge rates with a voltage mean error percentage of 0.423% and 1.186%, respectively. Optimal quadrotor mission range between the models varies up to 0.5 nmi, identifying current battery modeling methods as a potentially significant contributor to mission analysis error. A set of relevant tools and techniques for conceptual battery modeling are identified in this paper, with conclusions made on the utility of each modeling approach for various design challenges.

power

Methods and recommendations for large-scale deflagration testing of battery energy storage system enclosures

UL Solutions produced this report as a summary of a test series executed at Sandia National Laboratories that they funded. This report was approved for release by UL Solutions in October 2025 and released in 2026 on their website at https://www.ul.com/insights/methods-and-recommendations-large-scale-deflagration-testing-battery-energy-storage-system.

Gaudet, Benjamin [UL Solutions] (ORCID:00090006419

Biocybernetic Closed-Loop System for Mitigating Hazardous States of Awareness

The past century of passenger flight has seen continuous improvement in aviation safety by the aerospace industry. However, while commercial aviation accident rates have continued to decline, human error-related incident and accident rates remain remarkably constant across all types of aviation (Shappell, et al., 2007). Unfortunately, this level of human error is unacceptable when considering projections for increased traffic volume (FAA, 2009), and is likely to yield more incidents and accidents unless a more complete understanding of operator error is achieved and remediations are implemented. One area of interest highlighted by researchers is Hazardous States of Awareness (HSAs) that can result from deficiencies in the design and inappropriate use of human-machine interfaces. Identifying and mitigating HSAs is critical for reducing operator errors. One promising approach uses psychophysiological measures which enable automated systems to adapt to the operator?s state and modify modes of operation to support optimal human performance (Scerbo, 2007). This paper will survey previous research and describe future directions for the application of psychophysiological measures of operators derived from cortical and autonomic assessment to perform real-time adaptive modulation of human-automation task mode mixes. The authors will present a summary of previous work done at NASA LaRC and Old Dominion University using a Psychophysiologically Adaptive System (PAS) in which the level of automation of the NASA Multi-Attribute Task Battery was modulated based on Engagement Indices derived from the users? electroencephalogram (Pope, Bogart, & Bartolome, 1995; for review see, Scerbo, Freeman, & Mikulka, 2003). Future theoretical and methodological directions for this type of closed-loop research will be discussed. Specifically, the capacity for this type of PAS to maintain effective operator state and to enable validation of candidate physiological indices will be described. Consideration will also be given to critical system characteristics (e.g., engagement indices, methods for invoking changes among system states, individual differences among users, etc.) that have been or still need to be studied. The potential of the PAS approach for interactive system design and prototyping will also be described. Examples of adaptive automation flight deck concepts in recent experiments will be highlighted and discussed.

Chad L Stephens