Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Expansion of the Fuel Motion Monitoring System

The Idaho National Laboratory (INL) Transient Reactor Test Facility (TREAT) Fuel Motion Monitoring System (FMMS) is a diagnostic tool used to visualize the movement and location of fuel within the nuclear reactor during transient experiments. TREAT is designed to test the behavior of nuclear fuel under accident conditions, such as a rapid power increase. The TREAT FMMS, also referred to as the “hodoscope” because of the system’s massive steel collimator component, is located on the North beam port of the reactor. While the FMMS system is capable of incorporating a total of 360 sensors, initial refurbishment efforts resulted in a array of 96 fast neutron detectors. This initial array was configured to provide a narrow (2 channels) full-length view of experiment vessels with an extended 4-channel–wide region in the center of the array capable of providing a full view of all initially planned experiments. Planning and efforts to expand the FMMS array began immediately following the restart of TREAT. An additional 96 detectors were evaluated, characterized, and prepared for installation at TREAT during the summer of 2018. Unfortunately, funding reductions forced the project towards a 5-year hiatus. In October of 2023 funding from the Department of Energy’s Nuclear Science User Facilities enabled the expansion to recommence. This report serves to document the activities performed to expand the FMMS detector array to 192 channels in order to provide a broader view of the larger and more sophisticated test capsules currently planned for future irradiation in the TREAT reactor. This expansion also included doubling the data acquisition capability, addressing the new heat load on the system, and synchronizing the time for all digital components.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

BlueSTEAl: A pair of silicon arrays and a zero-degree phoswich detector for studies of scattering and reactions in inverse kinematics

BlueSTEAl, the Blue (aluminum chamber of) Silicon TElescope Arrays for light nuclei, has been developed to study direct reactions in inverse kinematics, as well as scattering and breakup reactions using radioactive ion beams. It is a detector system consisting of a pair of annular silicon detector arrays and a zero-degree phoswich plastic scintillator. For typical binary reaction studies in inverse kinematics, light ions are detected by the Si array in coincidence with heavy recoils detected by the phoswich placed at the focal-plane of a zero-degree magnetic spectrometer. The Si array can also be used to detect light nuclei such as beryllium and carbon with clear isotope separation, while the phoswich can also be placed at zero degrees without a spectrometer and used as a high-efficiency beam counting monitor with particle identification capability at the rate of up to ~5 × 10 4 particles per second. This paper reports on the capabilities of BlueSTEAl as determined by recent experiments performed at the Texas A&M Cyclotron Institute. Furthermore, the device is also anticipated to be used in future experiments at other radioactive ion beam facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DRiFT current mode, trigger settings and flexible detector specifications applied to scintillator arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

DRiFT Current Mode, Trigger Settings and Flexible Detector Specifications Applied to Scintillator Arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of position-sensitive resistive silicon detectors in the Forward Array Using Silicon Technology (FAUST)

The silicon telescopes of the Forward Array Using Silicon Technology (FAUST) have been recently upgraded with silicon detectors which use resistive charge-splitting to measure the position of charged particles. This is in addition to the measurement of the total energy that these charged particles deposit in the detector. The upgrade results in increased angular resolution with a much smaller number of signals than silicon strip detectors with similar resolution. Here, a novel method of calibration has been used to demonstrate the efficacy of these position-sensitive detectors, and the detectors have been used in a commissioning experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

All-epitaxial resonant cavity enhanced long-wave infrared detectors for focal plane arrays

Here, we demonstrate a monolithic all-epitaxial resonant-cavity architecture for long-wave infrared photodetectors with substrate-side illumination. An nBn detector with an ultra-thin (t ≈ 350 nm) absorber layer is integrated into a leaky resonant cavity, formed using semitransparent highly doped (n⁺⁺) epitaxial layers, and aligned to the anti-node of the cavity’s standing wave. The devices are characterized electrically and optically and demonstrate an external quantum efficiency of 25% at T ¼ 180 K in an architecture compatible with focal plane array configurations.

42 ENGINEERING↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Spatially resolved x-ray detection with photonic crystal scintillators

We study the self-collimation phenomenon in photonic crystals (PhC) of wide bandgap materials for ultra-fast and high spatial resolution x-ray detection. We work on various heavy inorganic scintillators: BaF 2 , GaN, ZnO, CsI:Tl, NaI:Tl, LYSO, WO 4 compounds, and plastic scintillators. Conventional scintillator detectors do not rely on a direct detection mechanism; hence, they require intricate design and fabrication processes. We offer a PhC design to observe self-collimation phenomena and overcome the ongoing spatial resolution challenges with these types of materials. We investigate the photonic band diagrams and iso-frequency contours. Fourier transforms based on finite-difference time-domain and frequency domain simulations are done for verifying and analyzing the self-collimation with the selected material. Light extraction efficiency at the PhC–air interface, depending on the truncation distance from the excitation point, is measured. Beam divergence values are calculated at 1 mm propagation distance. The vertical field profiles are obtained to observe the confinement. For the spatial resolution analysis, cross-sectional beam profiles have been examined. Furthermore, Gaussian envelopes are fitted to beam profiles for a consistent data analysis, and full-width-at-half-maximum values are considered. As a result, we theoretically prove and demonstrate the spatially resolved x-ray detection at the sub-micrometer level for a wide range of scintillator materials.

36 MATERIALS SCIENCE↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The LSU-Argonne conversion electron spectrometer: A new detector for the X-Array and SATURN decay station

In this study, a new conversion electron detector has been commissioned at the ATLAS/ CARIBU facility at Argonne National Laboratory. The LSU-Argonne Conversion Electron Spectrometer (LACES) is a LN 2 -cooled Si(Li) detector system designed to be incorporated into a decay station that comprises the dedicated HPGe clover array with a box geometry (X -Array) and the Scintillator and Tape Using Radioactive Nuclei (SATURN) device. This integration enables simultaneous measurements of conversion electrons and gamma-rays in decay experiments, yielding novel information on transition multipolarities, electric monopole transitions, and isomeric states that decay mostly via conversion electrons. A measurement of the energy resolution of LACES yielded 2.3-keV FWHM at 975 keV for electrons and 1.3-keV FWHM at 75 keV for X-rays. A detailed study of the absolute detection efficiency (at 5 mm from the source) was performed, where this quantity was determined experimentally in the range of electron transition energies between 25.5 keV and 1047.8 keV and subsequently simulated using the GEANT4 code. Measurement and simulations are found to be in excellent agreement. A precise characterization, for this type of detector system, of the absolute detection efficiency for such a wide energy range is reported for the first time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Second Generation Readout For Large Format Photon Counting Microwave Kinetic Inductance Detectors

We present the development of a second generation digital readout system for photon counting microwave kinetic inductance detector (MKID) arrays operating in the optical and near-infrared wavelength bands. Our system retains much of the core signal processing architecture from the first generation system but with a significantly higher bandwidth, enabling the readout of kilopixel MKID arrays. Each set of readout boards is capable of reading out 1024 MKID pixels multiplexed over 2 GHz of bandwidth; two such units can be placed in parallel to read out a full 2048 pixel microwave feedline over a 4 GHz–8 GHz band. As in the first generation readout, our system is capable of identifying, analyzing, and recording photon detection events in real time with a time resolution of order a few microseconds. Here, we describe the hardware and firmware, and present an analysis of the noise properties of the system. We also present a novel algorithm for efficiently suppressing IQ mixer sidebands to below −30 dBc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature-dependent characterization of large-area superconducting microwire array with single-photon sensitivity in the near-infrared

Superconducting nanowire single photon detectors (SNSPDs) are a leading detector technology for time-resolved single-photon counting from the ultraviolet to the near-infrared regime. The recent advancement in single-photon sensitivity in micrometer-scale superconducting wires opens up promising opportunities to develop large area SNSPDs with applications in low background dark matter detection experiments. Here, we present the first detailed temperature-dependent study of a 4-channel 1×1 mm 2 WSi superconducting microwire single photon detector (SMSPD) array, including the internal detection efficiency, dark count rate, and importantly the coincident dark counts across pixels. The detector shows saturated internal detection efficiency for photon wavelengths ranging from 635 nm to 1650 nm, time jitter of about 160 ps for 1060 nm photons, and a low dark count rate of about 10 -2 Hz. Additionally, the coincidences of dark count rate across pixels are studied for the first time in detail, where we observed an excess of correlated dark counts, which has important implications for low background dark matter experiments. The results presented is the first step towards characterizing and developing SMSPD array systems and associated background for low background dark matter detection experiments.

47 OTHER INSTRUMENTATION↗

Optical Design and Characterization of 40-GHz Detector and Module for the BICEP Array

Families of cosmic inflation models predict a primordial gravitational-wave background that imprints B-mode polarization pattern in the cosmic microwave background (CMB). High-sensitivity instruments with wide frequency coverage and well-controlled systematic errors are needed to constrain the faint B-mode amplitude. We have developed antenna-coupled transition edge sensor arrays for high-sensitivity polarized CMB observations over a wide range of millimeter-wave bands. BICEP array, the latest phase of the BICEP/Keck experiment series, is a multi-receiver experiment designed to search for inflationary B-mode polarization to a precision σ(r) between 0.002 and 0.004 after 3 full years of observations, depending on foreground complexity and the degree of lensing removal. We describe the electromagnetic design and measured performance of BICEP array’s low-frequency 40-GHz detector, their packaging in focal plane modules, and optical characterization including efficiency and beam matching between polarization pairs. We summarize the design and simulated optical performance, including an approach to improve the optical efficiency due to mismatch losses. Here, we report the measured beam maps for a new broadband corrugation design to minimize beam differential ellipticity between polarization pairs caused by interactions with the module housing frame, which helps minimize polarized beam mismatch that converts CMB temperature to polarization (T→P) anisotropy in CMB maps.

47 OTHER INSTRUMENTATION↗

Detector thickness effects on nanosecond-gated imager response

Hybrid CMOS multi-frame imagers with exposure times down to ~2 ns have made significant impacts in high energy density physics and inertial confinement fusion research. The detector thickness is a key parameter in both detector quantum efficiency and temporal response. The Icarus hybrid CMOS imager has been fabricated with Si detector thicknesses of 8, 25, and 100 µm. The temporal response of imaging sensors with exposure time down to 2 ns has been examined and compared to directly measured photodiode current. The 100-μm thick variant displays extended features related to charge carrier collection and is more susceptible to field collapse. Here, we also demonstrate charge collection time effects on spatial response.

47 OTHER INSTRUMENTATION↗

Search for photons above 10 18 eV by simultaneously measuring the atmospheric depth and the muon content of air showers at the Pierre Auger Observatory

The Pierre Auger Observatory is the most sensitive instrument to detect photons with energies above 1 0 17 eV . It measures extensive air showers generated by ultrahigh energy cosmic rays using a hybrid technique that exploits the combination of a fluorescence detector with a ground array of particle detectors. The signatures of a photon-induced air shower are a larger atmospheric depth of the shower maximum ( X max ) and a steeper lateral distribution function, along with a lower number of muons with respect to the bulk of hadron-induced cascades. In this work, a new analysis technique in the energy interval between 1 and 30 EeV ( 1 EeV = 1 0 18 eV ) has been developed by combining the fluorescence detector-based measurement of X max with the specific features of the surface detector signal through a parameter related to the air shower muon content, derived from the universality of the air shower development. No evidence of a statistically significant signal due to photon primaries was found using data collected in about 12 years of operation. Thus, upper bounds to the integral photon flux have been set using a detailed calculation of the detector exposure, in combination with a data-driven background estimation. The derived 95% confidence level upper limits are 0.0403, 0.01113, 0.0035, 0.0023, and 0.0021 km − 2 sr − 1 yr − 1 above 1, 2, 3, 5, and 10 EeV, respectively, leading to the most stringent upper limits on the photon flux in the EeV range. Compared with past results, the upper limits were improved by about 40% for the lowest energy threshold and by a factor 3 above 3 EeV, where no candidates were found and the expected background is negligible. The presented limits can be used to probe the assumptions on chemical composition of ultrahigh energy cosmic rays and allow for the constraint of the mass and lifetime phase space of super-heavy dark matter particles. Published by the American Physical Society 2024

79 ASTRONOMY AND ASTROPHYSICS↗

Active Activation Diagnostics for High Energy X-ray and Neutron Measurements

Nuclear activation is a vital tool for diagnosing the properties of high-energy particles and photons. We investigate several potential reactions and suitable activation materials that could be used to simultaneously measure both neutrons and high-energy bremsstrahlung x-rays using one detector. Such a diagnostic would be valuable and practical for several facilities capable of creating such high-energy neutrons and x-rays. Laser-generated sources, such as NIF(-ARC) or Omega(-EP), have been shown to be capable of creating high-energy x-rays via high-intensity laser interactions and neutrons via DT fusion reactions. Furthermore, current laser technology is driving the demand for higher repetition rate diagnostics, hence we further constrain reaction/activation selections to accommodate high-repletion rate experiments. Our investigation will concentrate on identifying potential short half-life activation materials associated with high-energy x-ray reactions that could be incorporated into the existing realtime neutron activation detectors (RTNADs), an array of 48 activation detectors positioned around the NIF target chamber used to measure the DT neutron yield isotropy. We have identified two materials, gold and neodymium, that appear to be the best candidates to complement the RTNADs, by adding a new high-energy x-ray measurement capability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗