Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

VERA User's Guide for Ex-core Applications

The Virtual Environment for Reactor Applications, or VERA, allows users to set up models to calculate time-dependent and fully coupled solutions for ex-core quantities of interest such as vessel and coupon fluence, and detector responses for multiple statepoints and cycles. MPACT and COBRA-TF together perform in-core transport calculations with temperature feedback while Shift performs the fluence and detector response calculations in the ex-core region. The in-core region is modeled using VERA’s native input format and the ex-core region is defined using Shift’s general geometry package, also known as Omnibus General Geometry. Fixed source ex-core calculations with Shift can be run in forward mode without advanced variance reduction (VR) methods, or with Consistent Adjoint Driven Importance Sampling (CADIS), which is an automated VR method. This document serves as a guide for setting up inputs, running ex-core calculations and post-processing the results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RadSim: Math, Utility & RTK

This package includes three parts, (1) gov.llnl.math, (2)gov.llnl.utility and (3)gov.llnl.rtk, which are utilized in the development of Radiation Detector Simulator (RadSim) project. RadSim is being developed to provide the capability to: (1) simulate radiation source emissions, (2) interpolate results from radiation transport tools into a common format to prepare incident flux, and (3) model radiation detector response to rapidly produce synthetic radiation measurement templates. RadSim is targeted for open-source release, which will enable researchers and industry partners to model gamma-ray detectors response to simulated flux from the transport tool of their choice. The techniques and implementation will be entirely transparent, which will allow for improvements and boutique modifications by future researchers beyond the lifespan of this specific project. The first tool of the package, gov.llnl.math, includes classes and functions to define and perform basic math operations. Some of the example features available in the package include defining statistical distributions and performing algebra and matrix operations, all of which are already accessible on publicly available software packages such as MATLAB and ROOT. The second package gov.llnl.utility includes tools commonly used to enable optimization and readability of various data structures such as Java lists and external xml files. Lastly, the gov.llnl.rtk package includes classes and functions to implement methods commonly used in radiation physics, such as data structures to represent and characterize photon spectra and tools to apply well-defined and published methods to calibrate a given spectra.

Cheung, Hoi Sing↗

RadSim: ENSDF, Xray and N42

This package includes three parts, (1) gov.bnl.nndc.ensdf, (2) gov.nist.xray and (3) gov.nist.physics.n42, which are utilized in the development of Radiation Detector Simulator (RadSim) project. RadSim is being developed to provide the capability to: (1) simulate radiation source emissions, (2) interpolate results from radiation transport tools into a common format to prepare incident flux, and (3) model radiation detector response to rapidly produce synthetic radiation measurement templates. RadSim is targeted for open-source release, which will enable researchers and industry partners to model gamma-ray detectors response to simulated flux from the transport tool of their choice. The first tool of the package, gov.bnl.nndc.ensdf, includes functionality to parse and split publicly available decay records in ENSDF format, and pull the relevant information from ENSDF libraries. The second tool, gov.nist.xray, provides Xray information using the public NIST database. Lastly, gov.nist.physics.n42, is a tool used to convert an N42 xml file into a Java object that can be interfaced within a Java program.

Hangal, DnaushA↗

Advancements of the nSpec system

For this study, a new characterization of the detector response for the EJ301 liquid scintillator based nSpec system has been conducted at the Los Alamos Neutron Science Center. The new characterization was accomplished in two orders of magnitude less time and with better statistics than the previous characterization. The new and old characterization methods were compared by conducting both types of characterization on two detectors (one EJ301 and one EJ301D). The two methods show consistent results and compare well to results previously published in the literature; however, the results from the characterization of the original nSpec detector show discrepancies that have been identified as being caused by oxygen being absorbed into the detector due to a leak. The new characterized detector response shows improved spectrum unfolding performance than the previous characterization. The cross talk of the detector system was also characterized as a function of incident neutron energy and found to have a negligible impact on spectrum unfolding results. Alternative materials (EJ301D and stilbene) were also characterized in a first step towards an upgraded system. The different materials show little difference in unfolding performance, but the comparison is ongoing. A SiPM based stilbene detector was used to evaluate the use of SiPMs in a future system upgrade. The SiPM provides adequate performance, but the custom SiPM readout results in a much longer pulse width than PMT based systems. The measured light output of the SiPM based stilbene compares well with the results in literature. Future work will look at additional materials (deuterated stilbene and organic glass) and optimizing the SiPM readout to decrease the pulse width.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a 127 Xe calibration source for nEXO

Here, we study a possible calibration technique for the nEXO experiment using a 127 Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay (0νββ) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in 136 Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of 127 Xe and its small Q-value compared to that of 136 Xe 0νββ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.

47 OTHER INSTRUMENTATION↗

An LSTM Deep Learning Network for ¿Background Radiation Prediction

Determination of appropriate background radiation is important in any measurement application. Environmental radiation monitors and monitors used to assess dose to individuals outside of controlled areas are particularly susceptible to changes in readings due to fluctuations in the environmental conditions. These fluctuations (e.g. radon progeny concentrations) lead to changes in the detector response in the actual radiation environment, and they need to be taken into account when extracting the net operational doses. Work has been ongoing to apply advances in Deep Learning and Artificial Intelligence to account for changes in detector responses based on environmental parameters; in particular, a Long-Short Term Memory (LSTM) Deep Learning architecture has been utilized to incorporate time-series data into a prediction model. In this work, we present the current status of the project to predict radiation measurements based on meteorological conditions and air packet trajectories extracted using the National Oceanic and Atmospheric Administration's (NOAA) Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT4) model.

Degtiarenko, Pavel↗

Modeling Urban Scenarios & Experiments: Fort Indiantown Gap Data Collections Summary and Analysis

This report summarizes experimental radiation detector, contextual sensor, weather, and global positioning system (GPS) data collected to inform and validate a comprehensive, operational radiation transport modeling framework to evaluate radiation detector system and algorithm performance. This framework will be used to study the influence of systematic effects (such as geometry, background activity, background variability, environmental shielding, etc.) on detector responses and algorithm performance using synthetic time series data. This work consists of performing data collection campaigns at a canonical, controlled environment for complete radiological characterization to help construct and benchmark a high-fidelity model with quantified system geometries, detector response functions, and source terms for background and threat objects. This data also provides an archival, benchmark dataset that can be used by the radiation detection community. The data reported here spans four data collection campaigns conducted between May 2015 and September 2016.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System and method for fissionable material detection with a short pulse neutron source

A system and method is disclosed for detecting fissionable materials. In one embodiment the system may incorporate a neutron pulse generator configured to generate multiple short pulses of neutrons, or a single pulse of sufficient intensity, in a vicinity of an object of interest. The source pulse of neutrons includes neutrons which each have a full width half maximum time duration of less than about 100 ns and a peak energy level no greater than about 20 MeV. A fast response detector is used which is able to detect single neutron events indicative of fission neutrons having been produced by the source pulse of neutrons interacting with fissionable material associated with the object of interest, and which arrive at the fast response detector within a predetermined time window immediately before arrival of the source neutron pulses.

Podpaly, Yuri↗

A scintillator-based approach to monitor secondary neutron production during proton therapy

Here, the primary objective of this work is to measure the secondary neutron field produced by an uncollimated proton pencil beam impinging on different tissue-equivalent phantom materials using organic scintillation detectors. Additionally, the Monte Carlo code mcnpx-PoliMi was used to simulate the detector response for comparison to the measured data. Comparison of the measured and simulated data will validate this approach for monitoring secondary neutron dose during proton therapy. Proton beams of 155- and 200-MeV were used to irradiate a variety of phantom materials and secondary particles were detected using organic liquid scintillators. These detectors are sensitive to fast neutrons and gamma rays: pulse shape discrimination was used to classify each detected pulse as either a neutron or a gamma ray. The mcnpx-PoliMi code was used to simulate the secondary neutron field produced during proton irradiation of the same tissue-equivalent phantom materials. As a result, an experiment was performed at the Loma Linda University Medical Center proton therapy research beam line and corresponding models were created using the mcnpx-PoliMi code. The authors’ analysis showed agreement between the simulations and the measurements. The simulated detector response can be used to validate the simulations of neutron and gamma doses on a particular beam line with or without a phantom. In conclusion, the authors have demonstrated a method of monitoring the neutron component of the secondary radiation field produced by therapeutic protons. The method relies on direct detection of secondary neutrons and gamma rays using organic scintillation detectors. These detectors are sensitive over the full range of biologically relevant neutron energies above 0.5 MeV and allow effective discrimination between neutron and photon dose. Because the detector system is portable, the described system could be used in the future to evaluate secondary neutron and gamma doses on various clinical beam lines for commissioning and prospective data collection in pediatric patients treated with proton therapy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SNAP-8 post shutdown gamma radiation approximations

Detector responses were calculated for normalized sources in the Perkins and King energy group structure for a SNAP 8 power system on a NASA space station. Gamma decay rates were then calculated by using an expanded, updated list of isotopic decay data, and from these, actual detector responses were found for the SNAP 8 system. The results indicate that energy-dependent calculations must be made to determine decay gamma dose rates for actual reactor configurations. A simplified method for making these calculations has been devised.

Byrn, N. R.↗

Improved image quality in pinhole SPECT by accurate modeling of the point spread function in low magnification systems

Purpose: Single photon emission computed tomography (SPECT) has become an important noninvasive imaging technique in small-animal research. Due to the high resolution required in small-animal SPECT systems, the spatially variant system response needs to be included in the reconstruction algorithm. Accurate modeling of the system response should result in a major improvement in the quality of reconstructed images. The aim of this study was to quantitatively assess the impact that an accurate modeling of spatially variant collimator/detector response has on image-quality parameters, using a low magnification SPECT system equipped with a pinhole collimator and a small gamma camera. Methods: Three methods were used to model the point spread function (PSF). For the first, only the geometrical pinhole aperture was included in the PSF. For the second, the septal penetration through the pinhole collimator was added. In the third method, the measured intrinsic detector response was incorporated. Tomographic spatial resolution was evaluated and contrast, recovery coefficients, contrast-to-noise ratio, and noise were quantified using a custom-built NEMA NU 4–2008 image-quality phantom. Results: A high correlation was found between the experimental data corresponding to intrinsic detector response and the fitted values obtained by means of an asymmetric Gaussian distribution. For all PSF models, resolution improved as the distance from the point source to the center of the field of view increased and when the acquisition radius diminished. An improvement of resolution was observed after a minimum of five iterations when the PSF modeling included more corrections. Contrast, recovery coefficients, and contrast-to-noise ratio were better for the same level of noise in the image when more accurate models were included. Ring-type artifacts were observed when the number of iterations exceeded 12. Conclusions: Accurate modeling of the PSF improves resolution, contrast, and recovery coefficients in the reconstructed images. To avoid the appearance of ring-type artifacts, the number of iterations should be limited. In low magnification systems, the intrinsic detector PSF plays a major role in improvement of the image-quality parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainty Quantification in GADRAS Inverse Modeling

The Gamma Detector Response and Analysis Software (GADRAS) package includes an inverse modeling tool that is helpful in identifying characteristics of unknown radioactive materials. Traditionally, uncertainties in this analysis were derived solely from measurement data quality and the fit of synthetic spectra. This paper aims to rigorously quantify additional sources of uncertainty, focusing on uncertainties arising from measurements being analyzed, Detector Response Function (DRF) characterization, and DRF extrapolation. Applying these findings to the BeRPBall benchmark data set, we demonstrated the impact of these uncertainties on plutonium and polyethylene estimates. The results underscore the importance of incorporating diverse uncertainty sources to enhance the accuracy and reliability of GADRAS’s inverse modeling capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superlattice-enhanced silicon soft X-ray and charged particle detectors with nanosecond time response

Here, silicon detectors are an essential measurement tool for Inertial Confinement Fusion and High-Energy-Density Physics Applications, where temporal response of the order of nanoseconds is essential. Soft X-rays (<1 keV), Ultraviolet light, and low-energy electrons (<10 keV) can provide essential information in diagnosing rapidly changing plasma conditions, but reducing the detector dead layer is essential to improving detector response for these shallowly absorbed particles. This paper details a study of silicon detector surface preparation methods such as ion implant parameters, and the addition of a quantum 2D superlattice, to produce fast detectors that are highly sensitive to shallowly absorbed radiation. Measurements of visible light quantum efficiency, electron responsivity, and pulsed x-ray response indicate that detectors with a 2-layer superlattice enjoy a significant benefit over equivalent detectors using an ion implant at the illuminated surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A pion-argon cross section measurement in the ProtoDUNE-SP experiment with cosmogenic muon

Neutrinos are tiny mysterious fundamental particles with small cross sections. Through neutrino physics, scientists across the world are trying to answer many intriguing questions about nature such as the dominance of matter over antimatter, CP violation in the lepton sector, number of supernovas in the early universe, etc. Detection of neutrinos requires massive particle detectors and intense neutrino beam owing to their small cross section. Deep Underground Neutrino Experiment (DUNE) is a next-generation neutrino experiment that is planned to start taking data beginning in 2026. DUNE will consist of 4 massive detectors, the first of which will be using single-phase liquid argon time projection chamber (LArTPC) technology. The ProtoDUNE-SP experiment is a prototype of the DUNE built at the CERN neutrino platform and uses the same detector technology that will be used in DUNE first module. The ProtoDUNE-SP experiment collected months of test beam and cosmic ray data beginning in September 2018. It was built to provide a testbed for the installation of detector parts for DUNE, showing long-term stability of the detector, understanding detector response for different test beam particles (including protons, pions, electrons, kaons, muons), and measurement of hadron-argon cross sections. When a particle passes through LArTPC electron-ion pairs are produced. To reconstruct the position and energy of a particle passing through the medium knowledge of ionization electron drift velocity is essential. The electron drift velocity is distorted by an excess positive charge built up in the detector, known as space charge. This study discusses a novel technique for measuring the ionization electron drift velocity using cosmic-ray muons. The technique uses tracks that travel the entire drift distance of the TPC for drift velocity determination. Secondly, the study discusses a method for converting the charge deposited into energy. The method is carried out in two step s. In th e first step detector response for energetic cosmic ray muons crossing the entire the TPC is used to make the charge deposition uniform throughout the TPC, and in the second step stopping cosmic-ray muons are used for determining the energy scale. Finally, the study discusses a pion-argon cross section measurement based on reweighting of Monte Carlo simulations using J. Calcutt's Geant4Reweight framework. Neutrinos cannot be directly detected; they are identified based on the interaction products. Pions are a common interaction product in a neutrino interaction. For precise modeling of neutrino event generators, it is essential to understand the pion-argon interaction. Pion-argon cross section measurement serves as an important input for neutrino interaction models. The results of the pion-argon total reaction cross section using the Geant4 reweighting technique are found to be in good agreement with Geant4 predictions. The many studies carried out in the ProtoDUNE-SP experi ment wil l be useful for current and future neutrino experiments using LArTPC technology including ICARUS, MicroBooNE, DUNE

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessment of MODIS and VIIRS Solar Diffuser On-Orbit Degradation

Both MODIS and VIIRS instruments use a solar diffuser (SD) for their reflective solar bands (RSB) on-orbit calibration. On-orbit changes in SD bi-directional reflectance factor (BRF) are tracked by a solar diffuser stability monitor (SDSM) using its alternate measurements of the sunlight reflected off the SD panel and direct sunlight through a fixed attenuation screen. The SDSM calibration data are collected by a number of filtered detectors, covering wavelengths from 0.41 to 0.94 micrometers. In this paper we describe briefly the Terra and Aqua MODIS and S-NPP VIIRS SDSM on-orbit operation and calibration activities and strategies, provide an overall assessment of their SDSM on-orbit performance, including wavelength-dependent changes in the SDSM detector responses and changes in their SD BRF, and discuss remaining challenging issues and their potential impact on RSB calibration quality. Due to different launch dates, operating configurations, and calibration frequencies, the Terra and Aqua MODIS and S-NPP VIIRS SD have experienced different amount of SD degradation. However, in general the shorter the wavelength, the larger is the SD on-orbit degradation. On the other hand, the larger changes in SDSM detector responses are observed at longer wavelengths in the near infrared (NIR).

MODIS↗

Improvements of VIIRS and MODIS Solar Diffuser and Lunar Calibration

Both VIIRS and MODIS instruments use solar diffuser (SD) and lunar observations to calibrate their reflective solar bands (RSB). A solar diffuser stability monitor (SDSM) is used to track the SD on-orbit degradation. On-orbit observations have shown similar wavelength-dependent SD degradation (larger at shorter VIS wavelengths) and SDSM detector response degradation (larger at longer NIR wavelengths) for both VIIRS and MODIS instruments. In general, the MODIS scan mirror has experienced more degradation in the VIS spectral region whereas the VIIRS rotating telescope assembly (RTA) mirrors have seen more degradation in the NIR and SWIR spectral region. Because of this wavelength dependent mirror degradation, the sensor's relative spectral response (RSR) needs to be modulated. Due to differences between the solar and lunar spectral irradiance, the modulated RSR could have different effects on the SD and lunar calibration. In this paper, we identify various factors that should be considered for the improvements of VIIRS and MODIS solar and lunar calibration and examine their potential impact. Specifically, we will characterize and assess the calibration impact due to SD and SDSM attenuation screen transmission (uncertainty), SD BRF uncertainty and onorbit degradation, SDSM detector response degradation, and modulated RSR resulting from the sensor's optics degradation. Also illustrated and discussed in this paper are the calibration strategies implemented in the VIIRS and MODIS SD and lunar calibrations and efforts that could be made for future improvements.

VIIRS↗

Semi-empirical simulation of in-motion radiation detection systems

The Replicative Assessment of Spectroscopic Equipment (RASE) is an open-source software that uses experimental data as the basis to simulate the response of commercial radiation detectors to sources in various situations, particularly in the context of nuclear security and safeguards applications. Dynamic RASE introduces the capability to simulate scenarios where sources and detector are in relative motion. Position-dependent experimentally acquired gamma spectra are ingested by Dynamic RASE to build maps that describe the detector response over all space. These response maps are used to replicate the time-dependent energy spectra collected as sources move on a path near the detector. Here, a Gaussian process is used to build each map, incorporating a novel kernel adapted to the special case of radiation detection. The approach has been validated against experimental data acquired using a NaI-based detector for 137 Cs and 54 Mn sources. The capability to create accurate simulations using either long-dwell static measurements or dynamic pass-by measurements as source data has been demonstrated. Quantitative relative performance, benefits, and shortcomings are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the neutrino-oxygen neutral current quasielastic cross section using the accelerator neutrino neutron interaction experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-doped water Cherenkov detector located on-axis to Fermilab’s Booster Neutrino Beam (BNB). ANNIE is uniquely positioned to perform high-statistics measurements of neutrino-nucleus interactions in water, benefiting from a large neutrino flux due to a short (100-meter) baseline. A central focus of ANNIE’s physics program is the measurement of both charged current (CC) and neutral current (NC) cross sections on water, including neutral current quasielastic (NCQE) and CC-inclusive channels. The NCQE measurement is particularly critical for constraining uncertainties in rare-event searches such as the Diffuse Supernova Neutrino Background (DSNB), where atmospheric $\nu$NCQE interactions constitute a significant and poorly constrained background. This dissertation presents a measurement of the flux-averaged neutrino-oxygen neutral current quasielastic ($\nu$NCQE) cross section using $2.573 \times 10^{20}$~POT of BNB exposure from the 2022 and 2023 beam years. The $\nu$NCQE interaction is identified through the primary $\gamma$-rays produced by nuclear de-excitation of the residual $^{15}$N$^*$ or $^{15}$O$^*$ nucleus following nucleon knockout from $^{16}$O. A dedicated Monte Carlo (MC) re-tuning campaign was conducted using an americium-beryllium (AmBe) calibration source, Michel electrons from stopped muons, and throughgoing dirt muons originating upstream of the detector. This multi-sample approach provided a wide-ranging $\mathcal{O}(\text{MeV})$--$\mathcal{O}(\text{GeV})$ dataset for tuning the simulated detector response, which was subsequently validated against AmBe neutron and Michel electron data for use in the $\nu$NCQE analysis. A dedicated laser calibration campaign was carried out to reduce timing uncertainties across the PMT system, enabling reconstruction of the BNB bunch substructure with sufficient resolution to serve as a background rejection tool. By selecting events in-time with individual neutrino bunches, beam-correlated $\nu$NCQE events are separated from diffuse and accelerator-induced backgrounds, notably skyshine neutrons and externally-originating events, that would otherwise dominate traditional charge-based selections within a small-scale, surface-level, short-baseline detector. A data-driven estimation of the skyshine neutron and external background rates was performed and incorporated into the systematic uncertainty budget. The flux-averaged $\nu$NCQE cross section on oxygen is measured to be $1.57 \pm 0.06\,(\text{stat.})$ $^{+0.91}_{-0.67}\,(\text{syst.})$ $\times 10^{-38}\ \text{cm}^{2}$. A full systematic budget is constructed by propagating uncertainties in the secondary hadronic interaction modeling, background cross section normalizations, detector response, neutrino flux, and the primary $\gamma$-ray emission probabilities from oxygen nuclear de-excitation. An idealized de-excitation model, constructed from existing measurements in the literature is developed to benchmark the predictions of the \textsc{GENIE} event generator. A comparison reveals that \textsc{GENIE} systematically overpredicts the primary $\gamma$-ray emission probability from oxygen de-excitation by a factor of $1.49\times$ for $E_\gamma > 6$~MeV and $3.07\times$ in the $3$--$6$~MeV band. This comparison motivates the dominant systematic uncertainty in this analysis, where a conservative uncertainty of $^{+39.9\%}_{-0\%}$ on the primary $\gamma$-ray signal prediction is assigned. The ANNIE result is consistent with and complementary to existing flux-averaged $\nu$NCQE cross section measurements from T2K and Super-Kamiokande, providing an independent measurement with a different detector, neutrino beam, and analysis methodology. Looking ahead, an upgrade to the ANNIE DAQ infrastructure enabling continuous extended readout will allow a complementary $\nu$NCQE neutron multiplicity measurement, directly relevant to constraining the NCQE background in DSNB searches, competitive with the recent T2K measurement at SK-Gd. The planned Super-SANDI upgrade, deploying a large Water-based Liquid Scintillator (WbLS) volume, will further extend ANNIE's reach to hadronic final states and exclusive NC channels, and enable joint measurements with liquid argon detectors sharing the BNB beamline ahead of DUNE and Hyper-Kamiokande.

Doran, Steven [Iowa State U.]↗