Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

DETECTION OF THE PULSAR WIND NEBULA HESS J1825-137 WITH THE FERMI LARGE AREA TELESCOPE

We announce the discovery of 1-100 GeV gamma-ray emission from the archetypal TeV pulsar wind nebula (PWN) HESS J1825-137 using 20 months of survey data from the Fermi-Large Area Telescope (LAT). The gamma-ray emission detected by the LAT is significantly spatially extended, with a best-fit rms extension of {sigma} = 0.{sup 0}56 {+-} 0.{sup 0}07 for an assumed Gaussian model. The 1-100 GeV LAT spectrum of this source is well described by a power law with a spectral index of 1.38 {+-} 0.12 {+-} 0.16 and an integral flux above 1 GeV of (6.50 {+-} 0.21 {+-} 3.90) x 10{sup -9} cm{sup -2} s{sup -1}. The first errors represent the statistical errors on the fit parameters, while the second ones are the systematic uncertainties. Detailed morphological and spectral analyses bring new constraints on the energetics and magnetic field of the PWN system. The spatial extent and hard spectrum of the GeV emission are consistent with the picture of an inverse Compton origin of the GeV-TeV emission in a cooling-limited nebula powered by the pulsar PSR J1826-1334.

79 ASTRONOMY AND ASTROPHYSICS↗

DETECTION OF HIGH-ENERGY GAMMA-RAY EMISSION DURING THE X-RAY FLARING ACTIVITY IN GRB 100728A

We present the simultaneous Swift and Fermi observations of the bright GRB 100728A and its afterglow. The early X-ray emission is dominated by a vigorous flaring activity continuing until 1 ks after the burst. In the same time interval, high-energy emission is significantly detected by the Fermi/Large Area Telescope. Marginal evidence of GeV emission is observed up to later times. We discuss the broadband properties of this burst within both the internal and external shock scenarios, with a particular emphasis on the relation between X-ray flares, the GeV emission, and a continued long-duration central engine activity as their power source.

79 ASTRONOMY AND ASTROPHYSICS↗

Mechanisms of NH3 and NO2 detection in carbon-nanotube-based sensors: An ab initio investigation

The mechanisms of NH3 and NO2 detection by single-walled carbon nanotube-based devices are investigated by ab initio calculations and the non-equilibrium Greens function (NEGF) methodology. While both NH3 and NO2 can physisorb to a pristine carbon nanotube, we show that their adsorption only results in small current changes through the device. For a carbon nanotube (CNT) attached to gold nanowire leads, the most sensitive detection site is at the CNT near the CNT-Au contact, where chemisorption occurs. The resulting change in electron transmission and low-bias current can lead to over 30% sensitivity. While both NH3 and NO2 can also chemisorb at the Au electrodes, their adsorption results in only a small change in the plurality of the conducting levels of the gold layers, and thus a small effect on current. In order to enhance the detection sensitivity, it is thus beneficial to mask the electrodes to prevent chemisorption. Furthermore, the length of the pure CNT segment does not strongly affect the relative sensitivity. Our results suggest that a short-CNT device with exposed contact regions and masked electrodes would have the greatest sensitivity.

Chemistry↗

Confining system integrity assessment by detection of natural gas migration using seismic diffractions [Seismic diffractions for gas leakage detection in the shallow waters of the Gulf of Mexico]

Successful carbon capture and storage (CCS) requires secure CO 2 confinement within a geologic reservoir. If associated with a depleted hydrocarbon reservoir, the sealing capability can be determined by examination of the shallow subsurface for hydrocarbon leaks. Numerous seismic signatures have been reported to be hydrocarbon indicators. The interpretation can be advanced by using seismic diffractions, which could indicate subtle hydrocarbon accumulations not detectable by conventional techniques. In this work, we investigate the potential of seismic diffractions for use in shallow gas detection. We extract diffractions from the ultra-high-resolution 3D P-Cable seismic dataset acquired along the Gulf of Mexico inner continental shelf. Interpretation of this dataset revealed numerous seismic signatures associated with hydrocarbon accumulations (e.g., a prominent gas chimney). We analyze scattering features of the detected hydrocarbon accumulations and confirm the correlation between confidently interpreted gas accumulations and seismic diffractions. Based on that, we suggest using diffractions for confining system integrity assessment. As a result, diffraction analysis allows operating with subtle seismic signals that facilitates exploration of reliable CO 2 storage sites.

58 GEOSCIENCES↗

The detection of the imprint of filaments on cosmic microwave background lensing [The first detection of the imprint of filaments on CMB lensing]

Here, galaxy redshift surveys, such as the 2-Degree-Field Survey (2dF)1, Sloan Digital Sky Survey (SDSS), 6-Degree-Field Survey (6dF), Galaxy And Mass Assembly survey (GAMA)and VIMOS Public Extragalactic Redshift Survey (VIPERS), have shown that the spatial distribution of matter forms a rich web, known as the cosmic web6. Most galaxy survey analyses measure the amplitude of galaxy clustering as a function of scale, ignoring information beyond a small number of summary statistics. Because the matter density field becomes highly non-Gaussian as structure evolves under gravity, we expect other statistical descriptions of the field to provide us with additional information. One way to study the non-Gaussianity is to study filaments, which evolve non-linearly from the initial density fluctuations produced in the primordial Universe. In our study, we report the detection of lensing of the cosmic microwave background (CMB) by filaments, and we apply a null test to confirm our detection. Furthermore, we propose a phenomenological model to interpret the detected signal, and we measure how filaments trace the matter distribution on large scales through filament bias, which we measure to be around 1.5. Our study provides new scope to understand the environmental dependence of galaxy formation. In the future, the joint analysis of lensing and Sunyaev-Zel'dovich observations might reveal the properties of 'missing baryons', the vast majority of the gas that resides in the intergalactic medium, which has so far evaded most observations.

79 ASTRONOMY AND ASTROPHYSICS↗

THE FIRST VLBI DETECTION OF AN ULTRACOOL DWARF: IMPLICATIONS FOR THE DETECTABILITY OF SUB-STELLAR COMPANIONS

We present milliarcsecond-resolution radio very long baseline interferometry (VLBI) observations of the ultracool dwarfs TVLM 513-46546 (M8.5) and 2MASS J00361617+1821104 (L3.5) in an attempt to detect sub-stellar companions via direct imaging or reflex motion. Both objects are known radio emitters with strong evidence for periodic emission on timescales of about 2 hr and 3 hr, respectively. Using the inner seven VLBA antennas, we detect unresolved emission from TVLM 513-46546 on a scale of 2.5 mas (approx50 stellar radii), leading to a direct limit on the radio emission brightness temperature of T{sub B} approx> 4 x 10{sup 5} K. However, with the higher spatial resolution afforded by the full VLBA we find that the source appears to be marginally resolved at a low signal-to-noise ratio, possibly indicating that TVLM 513-46546 is a binary with a projected separation of approx1 mas (approx20 stellar radii). Using the 7 hr baseline of our observation, we find no astrometric shift in the position of TVLM 513-46546, with a 3sigma limit of about 0.6 mas. This is about three times larger than expected for an equal-mass companion with a few-hour orbital period. Future monitoring of its position on a range of timescales will provide the required astrometric sensitivity to detect a planetary companion with a mass of approx10 M {sub J} in a approx>15 day (approx>0.06 AU) orbit, or with a mass of approx2 M {sub J} in an orbit of approx>0.5 yr (approx>0.3 AU).

79 ASTRONOMY AND ASTROPHYSICS↗

LATE-TIME DETECTIONS OF THE X-RAY AFTERGLOW OF GRB 060729 WITH CHANDRA-THE LATEST DETECTIONS EVER OF AN X-RAY AFTERGLOW

We report on five Chandra observations of the X-ray afterglow of the gamma-ray burst (GRB) 060729 performed between 2007 March and 2008 May. In all five observations, the afterglow is clearly detected. The last Chandra pointing was performed on 2008 May 4, 642 days after the burst-the latest detection of a GRB X-ray afterglow ever. A reanalysis of the Swift XRT light curve together with the three detections by Chandra in 2007 reveals a break at {approx}1.0 Ms after the burst with a slight steepening of the decay slope from alpha = 1.32 to 1.61. This break coincides with a significant hardening of the X-ray spectrum, consistent with a cooling break in the wind medium scenario, in which the cooling frequency of the afterglow crosses the X-ray band. The last two Chandra observations in 2007 December and 2008 May provide evidence for another break at about one year after the burst. If interpreted as a jet break, this late-time break implies a jet half-opening angle of {approx}14{sup 0} for a wind medium. Alternatively, this final break may have a spectral origin, in which case no jet break has been observed and the half-opening angle of the jet of GRB 060729 must be larger than {approx}15{sup 0} for a wind medium. We compare the X-ray afterglow of GRB 060729 in a wind environment with other bright X-ray afterglows, in particular GRBs 061121 and 080319B, and discuss why the X-ray afterglow of GRB 060729 is such an exceptionally long-lasting event.

79 ASTRONOMY AND ASTROPHYSICS↗

A comparison of the neutron detection efficiency and response characteristics of two pixelated PSD-capable organic scintillator detectors with different photo-detection readout methods

Here, we characterize the performance of two pixelated neutron detectors: a PMT-based array that utilizes Anger logic for pixel identification and a SiPM-based array that employs individual pixel readout. The SiPM-based array offers improved performance over the previously developed PMT-based detector both in terms of uniformity and neutron detection efficiency. Each detector array uses PSD-capable plastic scintillator as a detection medium. We describe the calibration and neutron efficiency measurement of both detectors using a 137 Cs source for energy calibration and a 252 Cf source for calibration of the neutron response. We find that the intrinsic neutron detection efficiency of the SiPM-based array is (30.2 ± 0.9)%, which is almost twice that of the PMT-based array, which we measure to be (16.9 ± 0.1)%.

47 OTHER INSTRUMENTATION↗

Detection of regional infrasound signals using array data: Testing, tuning, and physical interpretation

This work quantifies the physical characteristics of infrasound signal and noise, assesses their temporal variations, and determines the degree to which these effects can be predicted by time-varying atmospheric models to estimate array and network performance. An automated detector that accounts for both correlated and uncorrelated noise is applied to infrasound data from three seismo-acoustic arrays in South Korea (BRDAR, CHNAR, and KSGAR), cooperatively operated by Korea Institute of Geoscience and Mineral Resources (KIGAM) and Southern Methodist University (SMU). Arrays located on an island and near the coast have higher noise power, consistent with both higher wind speeds and seasonably variable ocean wave contributions. On the basis of the adaptive F-detector quantification of time variable environmental effects, the time-dependent scaling variable is shown to be dependent on both weather conditions and local site effects. Significant seasonal variations in infrasound detections including daily time of occurrence, detection numbers, and phase velocity/azimuth estimates are documented. These time-dependent effects are strongly correlated with atmospheric winds and temperatures and are predicted by available atmospheric specifications. As a result, this suggests that commonly available atmospheric specifications can be used to predict both station and network detection performance, and an appropriate forward model improves location capabilities as a function of time.

47 OTHER INSTRUMENTATION↗

Detect the Unobservable: Abnormality Detection in mixed Autonomy for Lane Change Maneuver with Following Vehicles’ Trajectories Only

Highly Automated Vehicles (HAVs) and Advanced Driver-Assistance Systems (ADAS) are transforming modern transportation with enhanced mobility, safety, and efficiency. Despite their advantages, cybersecurity vulnerabilities in these systems can lead to abnormal behavior, posing significant risks to surrounding human-driven vehicles (HDVs) in mixed traffic environments. Here, this article addresses the challenge of detecting abnormal lateral movements of HAVs/ADAS vehicles using only trajectory profiles of following HDVs. Specifically, we propose a novel modeling approach that captures both normal and abnormal lateral behaviors through vehicle kinematics, integrated decision-making processes, vehicle control using symbolic regression for lane change vehicles. Additionally, we introduce an abnormality detection framework that relies on observable HDV data, even in occlusion scenarios. The framework evaluates the sensitivity of various car-following models to detect abnormal behaviors, providing insights into the interaction between HAVs/ADAS and HDVs in mixed autonomy systems.

Connected and Automated vehicles↗

Cloud-Enabled Microscopy and Droplet Microfluidic Platform for Specific Detection of Escherichia coli in Water

We report an all-in-one platform – ScanDrop – for the rapid and specific capture, detection, and identification of bacteria in drinking water. The ScanDrop platform integrates droplet microfluidics, a portable imaging system, and cloud-based control software and data storage. The cloud-based control software and data storage enables robotic image acquisition, remote image processing, and rapid data sharing. These features form a “cloud” network for water quality monitoring. We have demonstrated the capability of ScanDrop to perform water quality monitoring via the detection of an indicator coliform bacterium, Escherichia coli, in drinking water contaminated with feces. Magnetic beads conjugated with antibodies to E. coli antigen were used to selectively capture and isolate specific bacteria from water samples. The bead-captured bacteria were co-encapsulated in pico-liter droplets with fluorescently-labeled anti-E. coli antibodies, and imaged with an automated custom designed fluorescence microscope. The entire water quality diagnostic process required 8 hours from sample collection to online-accessible results compared with 2–4 days for other currently available standard detection methods.

59 BASIC BIOLOGICAL SCIENCES↗

Kick Detection at the Bit: Early Detection via Low Cost Monitoring

Formation fluid influxes (i.e. kicks) pose persistent challenges and operational costs during drilling operations. Implications of kicks range in scale but cumulatively result in substantial costs that affect drilling safety, environment, schedule, and infrastructure. Early kick detection presents a low-cost, easily adopted solution for avoiding well control challenges associated with kicks near the bit. Borehole geophysical tools used during the drilling process as part of the logging-while-drilling (LWD) and measurement-while-drilling (MWD) provide the advantage of offering real-time downhole data. LWD/MWD collect data on both the annulus and borehole wall. The annular data are normally treated as background, and are filtered out to isolate the formation measurements. Because kicks will change the local physical properties of annular fluids, bottom-hole measurements are among the first indicators that a formation fluid has invaded the wellbore. This report describes and validates a technique for using the annular portion of LWD/MWD data to facilitate early kick detection using first order principles. The detection technique leverages data from standard and cost-effective technologies that are typically implemented during well drilling, such as MWD/LWD data in combination with mud-pulse telemetry for data transmission.

42 ENGINEERING↗

Special Nuclear Material Detection and Monitoring by Environmental Activation Products Detection

Through a series of measurements with a high purity germanium detector, we have established that the past presence of neutron emitting material can be detected by the decay of activation products in aluminum containers, tungsten shielding, and concrete floors even several days after last exposure. The time since last exposure can also be estimated by the gamma-ray detection rate. These findings may lead to interesting new CONOPS in the detection of illicit SNM or the verification of the absence (or presence) of SNM containing objects in facilities and/or transit even after the material has been removed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗