Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Demand response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

FERC sees huge potential for demand response

The FERC study concludes that U.S. peak demand can be reduced by as much as 188 GW -- roughly 20 percent -- under the most aggressive scenario. More moderate -- and realistic -- scenarios produce smaller but still significant reductions in peak demand. The FERC report is quick to point out that these are estimates of the potential, not projections of what could actually be achieved. The main varieties of demand response programs include interruptible tariffs, direct load control (DLC), and a number of pricing schemes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Open Automated Demand Response for Small Commerical Buildings

This report characterizes small commercial buildings by market segments, systems and end-uses; develops a framework for identifying demand response (DR) enabling technologies and communication means; and reports on the design and development of a low-cost OpenADR enabling technology that delivers demand reductions as a percentage of the total predicted building peak electric demand. The results show that small offices, restaurants and retail buildings are the major contributors making up over one third of the small commercial peak demand. The majority of the small commercial buildings in California are located in southern inland areas and the central valley. Single-zone packaged units with manual and programmable thermostat controls make up the majority of heating ventilation and air conditioning (HVAC) systems for small commercial buildings with less than 200 kW peak electric demand. Fluorescent tubes with magnetic ballast and manual controls dominate this customer group's lighting systems. There are various ways, each with its pros and cons for a particular application, to communicate with these systems and three methods to enable automated DR in small commercial buildings using the Open Automated Demand Response (or OpenADR) communications infrastructure. Development of DR strategies must consider building characteristics, such as weather sensitivity and load variability, as well as system design (i.e. under-sizing, under-lighting, over-sizing, etc). Finally, field tests show that requesting demand reductions as a percentage of the total building predicted peak electric demand is feasible using the OpenADR infrastructure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficient Customer Selection for Sustainable Demand Response in Smart Grids

Regulating the power consumption to avoid peaks in demand is a common practice. Demand Response(DR) is being used by utility providers to minimize costs or ensure system reliability. Although it has been used extensively there is a shortage of solutions dealing with dynamic DR. Past attempts focus on minimizing the load demand without considering the sustainability of the reduced energy. In this paper an efficient algorithm is presented which solves the problem of dynamic DR scheduling. Data from the USC campus micro grid were used to evaluate the efficiency as well as the robustness of the proposed solution. The targeted energy reduction is achieved with a maximum average approximation error of ≈ 0.7%. Sustainability of the reduced energy is achieved with respect to the optimal available solution providing a maximum average error less than 0.6%. It is also shown that a solution is provided with a low computational cost fulfilling the requirements of dynamic DR.

change making↗

Demand Response Opportunities in Industrial Refrigerated Warehouses in California

Industrial refrigerated warehouses that implemented energy efficiency measures and have centralized control systems can be excellent candidates for Automated Demand Response (Auto-DR) due to equipment synergies, and receptivity of facility managers to strategies that control energy costs without disrupting facility operations. Auto-DR utilizes OpenADR protocol for continuous and open communication signals over internet, allowing facilities to automate their Demand Response (DR). Refrigerated warehouses were selected for research because: They have significant power demand especially during utility peak periods; most processes are not sensitive to short-term (2-4 hours) lower power and DR activities are often not disruptive to facility operations; the number of processes is limited and well understood; and past experience with some DR strategies successful in commercial buildings may apply to refrigerated warehouses. This paper presents an overview of the potential for load sheds and shifts from baseline electricity use in response to DR events, along with physical configurations and operating characteristics of refrigerated warehouses. Analysis of data from two case studies and nine facilities in Pacific Gas and Electric territory, confirmed the DR abilities inherent to refrigerated warehouses but showed significant variation across facilities. Further, while load from California's refrigerated warehouses in 2008 was 360 MW with estimated DR potential of 45-90 MW, actual achieved was much less due to low participation. Efforts to overcome barriers to increased participation may include, improved marketing and recruitment of potential DR sites, better alignment and emphasis on financial benefits of participation, and use of Auto-DR to increase consistency of participation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Future Opportunities and Challenges with Using Demand Response as a Resource in Distribution System Operation and Planning Activities

This scoping study focuses on identifying the ability for current and future demand response opportunities to contribute to distribution system management. To do so, this scoping study will identify the needs of a distribution system to operate efficiently, safely and reliably; summarize both benefits and challenges for the operation of the distribution system with high penetration levels of distributed energy resources; define a suite of services based on those changing operational needs that could be provided by resources; identify existing demand response opportunities sponsored by distribution utilities and/or aggregators of retail customers; assess the extent to which distribution system services can be provided via DR opportunities both in their current form and with alterations to their design; and provide a qualitative assessment of coordination issues that bulk power and distribution system providers of DR opportunities will need to address.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration of Renewables Via Demand Management: Highly Dispatchable and Distributed Demand Response for the Integration of Distributed Generation

GENI Project: AutoGrid, in conjunction with Lawrence Berkeley National Laboratory and Columbia University, will design and demonstrate automated control software that helps manage real-time demand for energy across the electric grid. Known as the Demand Response Optimization and Management System - Real-Time (DROMS-RT), the software will enable personalized price signal to be sent to millions of customers in extremely short timeframes—incentivizing them to alter their electricity use in response to grid conditions. This will help grid operators better manage unpredictable demand and supply fluctuations in short time-scales —making the power generation process more efficient and cost effective for both suppliers and consumers. DROMS-RT is expected to provide a 90% reduction in the cost of operating demand response and dynamic pricing Projects in the U.S.

ARPA-E↗

Improved Air-Conditioning Demand Response of Connected Communities over Individually Optimized Buildings

Connected communities potentially offer much greater demand response capabilities over singular building energy management systems (BEMS) through an increase of connectivity. The potential increase in benefits from this next step in connectivity is still under investigation, especially when applied to existing buildings. This work utilizes EnergyPlus simulation results on eight different commercial prototype buildings to estimate the potential savings on peak demand and energy costs using a mixed-integer linear programming model. This model is used in two cases: a fully connected community and eight separate buildings with BEMS. The connected community is optimized using all zones as variables, while the individual buildings are optimized separately and then aggregated. These optimization problems are run for a range of individual zone flexibility values. The results indicate that a connected community offered 60.0% and 24.8% more peak demand savings for low and high flexibility scenarios, relative to individually optimized buildings. Energy cost optimization results show only marginally better savings of 2.9% and 6.1% for low and high flexibility, respectively.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Spillover as a cause of bias in baseline evaluation methods for demand response programs

Prior research has shown load reduction estimates from residential event-driven demand response programs (e.g., Critical Peak Pricing)using X of the highest Y days with a weather adjustment method are the best performing within the class of currently used baseline methods. However, they are still biased relative to estimates produced from randomized control trials (RCTs), the unbiased “gold standard” evaluation method. In this paper we identify underlying factors that cause some of the bias found in one commonly used baseline method. Rather than simply quantifying bias, our research provides a deeper understanding of what causes the bias and thus can be used to develop more accurate methods that are not subject to these underlying factors. Previous studies have compared various baseline methods relative to each other; however, because all baseline methods are biased, it is impossible to determine the true bias that exists in them. We have access to a unique RCT dataset: the Sacramento Municipal Utility District's study of critical peak pricing. Our analysis of 23 event days over two summers allows us to identify the true bias on load reduction estimates by using the RCT estimates as the unbiased gold standard against which we compare the estimates from the baseline methods. We found that spillover of energy reductions, from hours targeted by a program onto other hours, is one underlying factor that is a major cause of bias in baseline methods. We discuss alternative baseline methods that may not be subject to this same bias.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automated Demand Response Technology Demonstration for Small and Medium Commercial Buildings

Small and medium commercial customers in California make up about 20-25% of electric peak load in California. With the roll out of smart meters to this customer group, which enable granular measurement of electricity consumption, the investor-owned utilities will offer dynamic prices as default tariffs by the end of 2011. Pacific Gas and Electric Company, which successfully deployed Automated Demand Response (AutoDR) Programs to its large commercial and industrial customers, started investigating the same infrastructures application to the small and medium commercial customers. This project aims to identify available technologies suitable for automating demand response for small-medium commercial buildings; to validate the extent to which that technology does what it claims to be able to do; and determine the extent to which customers find the technology useful for DR purpose. Ten sites, enabled by eight vendors, participated in at least four test AutoDR events per site in the summer of 2010. The results showed that while existing technology can reliably receive OpenADR signals and translate them into pre-programmed response strategies, it is likely that better levels of load sheds could be obtained than what is reported here if better understanding of the building systems were developed and the DR response strategies had been carefully designed and optimized for each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demand Response Analysis for Different Residential Personas in a Comfort-Driven Behavioral Context

Low demand response (DR) participation and high program drop-out rates continue to impede DR goals that could save up to $13 billion in annual grid expansion and electricity demand costs. Yet, the literature lacks a thorough understanding of how different residential customer segments enrolled in DR programs respond to utility signals in view of occupant comfort considerations. The objective of this study is to gain a clear understanding of the effects of four different customer personas on residential DR. Given current data limitations, this work developed an array of hypothetical personas with varied priorities, activity levels, and comfort thresholds based on demographic variables that have been found in previous studies to influence energy consumption. A BEopt DR model for a reference residential single-family building located in Colorado was built to isolate the effect of differences in buildings or climate. The results provide useful evidence on how persona-comfort differences lead to significant deviations in DR goals (especially peak demand reduction), ranging from 0.1% to 20%. This work presents a novel framework representing comfort preferences in DR models. The data generated, albeit synthetic, and the results could inform DR program design considerations of how different people respond to different comfort priorities.

BEopt↗

When it comes to demand response, is FERC its own worst enemy?

There is a significant risk of creating conditions that will crowd out true price response by focusing too much on demand response programs with unverifiable baselines and reliability-based rather than price-based mechanisms for obtaining consumption reductions. (author)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Edge-Cloud Integrated Solution for Buildings Demand Response Using Reinforcement Learning

Buildings, as major energy consumers, can provide great untapped demand response (DR) resources for grid services. However, their participation remains low in real-life. One major impediment for popularizing DR in buildings is the lack of cost-effective automation systems that can be widely adopted. Existing optimization-based smart building control algorithms suffer from high costs on both building-specific modeling and on-demand computing resources. To tackle these issues, this paper proposes a cost-effective edge-cloud integrated solution using reinforcement learning (RL). Beside RL’s ability to solve sequential optimal decision-making problems, its adaptability to easy-to-obtain building models and the off-line learning feature are likely to reduce the controller’s implementation cost. Using a surrogate building model learned automatically from building operation data, an RL agent learns an optimal control policy on cloud infrastructure, and the policy is then distributed to edge devices for execution. Simulation results demonstrate the control efficacy and the learning efficiency in buildings of different sizes. A preliminary cost analysis on a 4-zone commercial building shows the annual cost for optimal policy training is only 2.25% of the DR incentive received. Results of this study show a possible approach with higher return on investment for buildings to participate in DR programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Challenge Online Time Series Clustering For Demand Response A Theory to Break the ‘Curse of Dimensionality'

The advent of smart meters and advanced communication infrastructures catalyzes numerous smart grid applications such as dynamic demand response, and paves the way to solve challenging research problems in sustainable energy consumption. The space of solution possibilities are restricted primarily by the huge amount of generated data requiring considerable computational resources and efficient algorithms. To overcome this Big Data challenge, data clustering techniques have been proposed. Current approaches however do not scale in the face of the “increasing dimensionality” problem where a cluster point is represented by the entire customer consumption time series. To overcome this aspect we first rethink the way cluster points are created and designed, and then design an efficient online clustering technique for demand response (DR) in order to analyze high volume, high dimensional energy consumption time series data at scale, and on the fly. Our online algorithm is randomized in nature, and provides optimal performance guarantees in a computationally efficient manner. Unlike prior work we (i) study the consumption properties of the whole population simultaneously rather than developing individual models for each customer separately, claiming it to be a ‘killer’ approach that breaks the “curse of dimensionality” in online time series clustering, and (ii) provide tight performance guarantees in theory to validate our approach. Our insights are driven by the field of sociology, where collective behavior often emerges as the result of individual patterns and lifestyles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Operation of an Open, Interoperable Automated Demand Response Infrastructure for Commercial Buildings

This paper describes the concept for and lessons from the development and field-testing of an open, interoperable communications infrastructure to support automated demand response (auto-DR). Automating DR allows greater levels of participation, improved reliability, and repeatability of the DR in participating facilities. This paper also presents the technical and architectural issues associated with auto-DR and description of the demand response automation server (DRAS), the client/server architecture-based middle-ware used to automate the interactions between the utilities or any DR serving entity and their customers for DR programs. Use case diagrams are presented to show the role of the DRAS between utility/ISO and the clients at the facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Demand Response Incorporating Distribution LMP with PV Generation Uncertainty

The utilization of aggregated demand-side flexibility via demand response (DR) has become a promising pathway for the integration of renewable energy resources in power systems. Nowadays, there are several management strategies for DR such as the price-based transactive control strategies. However, many of such existing price-based control strategies neglect the physics and operational constraints of the underlying distribution networks when computing the price, raising concerns regarding their theoretical and practical values. This paper studies this issue and investigates optimal DR (ODR) by incorporating the distribution locational marginal price (DLMP). In particular, we discuss DR in connection with DLMPs and propose a multiperiod bilevel optimization problem to find the ODR strategy. Here, the objective is to minimize the peak load, load fluctuation, and payments of load aggregators. In addition, a robust bilevel ODR model is formulated to provide a robust ODR strategy while minimizing operating costs under the worst-case realization of uncertainties; this mitigates the impact of forecasting errors on renewable energy resources. Then, we propose an efficient solution approach by employing the Karush-Kuhn-Tucker conditions and strong duality. Simulation results are presented to illustrate the mutual impacts of the interaction between DR and DLMP and the benefits of the robust ODR strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Foresee: A user-centric home energy management system for energy efficiency and demand response

This paper presents foresee, a user-centric home energy management system that can help optimize how a home operates to concurrently meet users' needs, achieve energy efficiency and commensurate utility cost savings, and reliably deliver grid services based on utility signals. Foresee is built on a multiobjective model predictive control framework, wherein the objectives consist of energy cost, thermal comfort, user convenience, and carbon emission. Foresee learns user preferences on different objectives and acts on their behalf to operate building equipment, such as home appliances, photovoltaic systems, and battery storage. In this work, machine-learning algorithms were used to derive data-driven appliance models and usage patterns to predict the home's future energy consumption. This approach enables highly accurate predictions of comfort needs, energy costs, environmental impacts, and grid service availability. Simulation studies were performed on field data from a residential building stock data set collected in the Pacific Northwest. Results indicated that foresee generated up to 7.6% whole-home energy savings without requiring substantial behavioral changes. When responding to demand response events, foresee was able to provide load forecasts upon receipt of event notifications and delivered the committed demand response services with 10% or fewer errors. Foresee fully utilized the potential of the battery storage and controllable building loads and delivered up to 7.0-kW load reduction and 13.5-kW load increase. As a result, these benefits are provided while maintaining the occupants' thermal comfort or convenience in using their appliances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demand Response Performance of GE Hybrid Heat Pump Water Heater

This report describes a project to evaluate and document the DR performance of HPWH as compared to ERWH for two primary types of DR events: peak curtailments and balancing reserves. The experiments were conducted with GE second-generation “Brillion”-enabled GeoSpring hybrid water heaters in the PNNL Lab Homes, with one GE GeoSpring water heater operating in “Standard” electric resistance mode to represent the baseline and one GE GeoSpring water heater operating in “Heat Pump” mode to provide the comparison to heat pump-only demand response. It is expected that “Hybrid” DR performance, which would engage both the heat pump and electric elements, could be interpolated from these two experimental extremes. Signals were sent simultaneously to the two water heaters in the side-by-side PNNL Lab Homes under highly controlled, simulated occupancy conditions. This report presents the results of the evaluation, which documents the demand-response capability of the GE GeoSpring HPWH for peak load reduction and regulation services. The sections describe the experimental protocol and test apparatus used to collect data, present the baselining procedure, discuss the results of the simulated DR events for the HPWH and ERWH, and synthesize key conclusions based on the collected data.

Demand Response↗