Measurement of the transverse momentum and Φ$*\atop{η}$ distributions of Drell–Yan lepton pairs in proton–proton collisions at √s=8 TeV with the ATLAS detector

Distributions of transverse momentum p$ℓℓ\atop{T}$ and the related angular variable Φ$*\atop{η}$ of DrellΓÇôYan lepton pairs are measured in 20.3$\perp$áfb -1 of protonΓÇôproton collisions at √s=8$\perp$áTeV with the ATLAS detector at the LHC. Measurements in electron-pair and muon-pair final states are corrected for detector effects and combined. Compared to previous measurements in protonΓÇôproton collisions at √s=7$\perp$áTeV, these new measurements benefit from a larger data sample and improved control of systematic uncertainties. Measurements are performed in bins of lepton-pair mass above, around and below the Z-boson mass peak. The data are compared to predictions from perturbative and resummed QCD calculations. For values of Φ$*\atop{η}$<1 the predictions from the Monte Carlo generator ResBos are generally consistent with the data within the theoretical uncertainties. However, at larger values of Φ$*\atop{η}$ this is not the case. Monte Carlo generators based on the parton-shower approach are unable to describe the data over the full range of pℓℓTpTℓℓ while the fixed-order prediction of Dynnlo falls below the data at high values of p$ℓℓ\atop{T}$ . ResBos and the parton-shower Monte Carlo generators provide a much better description of the evolution of the Φ$*\atop{η}$ and p$ℓℓ\atop{T}$ distributions as a function of lepton-pair mass and rapidity than the basic shape of the data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Intelligent Experiments Through Real-time AI: Fast Data Processing and Autonomous Detector Control for sPHENIX and Future EIC Detectors (Final Report)

The overall vision of this project was to integrate real-time artificial intelligence (AI) directly into the data acquisition and detector-control systems of nuclear physics experiments, including both fast online event selection and an autonomous detector-control feedback loop. The work carried out under the award focused on the fast online event-selection half of that vision: the efficient recording of low-momentum heavy-flavor (HF) hadron decays in proton-proton collisions at the sPHENIX experiment at the Relativistic Heavy Ion Collider (RHIC)—an observable that requires fast tracking and topological trigger selection not previously demonstrated at RHIC, and that is essential for QCD studies at future facilities such as the Electron-Ion Collider (EIC). The autonomous detector-control (GPU-based feedback) component named in the project title remained a design concept and was not implemented under this award. The Massachusetts Institute of Technology (MIT) group led the offline simulation and data processing needed to train the machine-learning (ML) models, the translation of trained models to Field-Programmable Gate Array (FPGA) firmware using the hls4ml framework, and the physics validation of heavy-flavor reconstruction. Over the award period, the team developed and hardware-tested the principal components of an AI-based heavy-flavor trigger on simulated and recorded sPHENIX tracker data: a software Bipartite Graph Attention Network (BiGAT) trigger model reaching > 95% signal efficiency at 99% background rejection; an FPGA-native hit clusterizer matching the offline clustering; smaller networks synthesized to FPGA within the required sub-10 µs latency; and an assembled decoder–clusterizer–inference firmware chain exercised on the FELIX readout board. A complete, fully integrated hardware demonstrator was not finished within the award period. This report documents the project goals, the MIT group’s contributions, the technical accomplishments, and the outlook toward applications at the future EIC ePIC detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FEASIBILITY STUDY FOR THE DEVELOPMENT OF A TEST BED PROGRAM FOR NOVEL DETECTORS AND DETECTOR MATERIALS AT SRS H-CANYON SEPARATIONS FACILITY

Researchers at the Savannah River National Laboratory (SRNL) have proposed that a test bed for advanced detectors be established at the H-Canyon separations facility located on the DOE Savannah River Site. The purpose of the proposed test bed will be to demonstrate the capabilities of emerging technologies for national and international safeguards applications in an operational environment, and to assess the ability of proven technologies to fill any existing gaps. The need for such a test bed has been expressed in the National Nuclear Security Administration's (NNSA) Next Generation Safeguards Initiative (NGSI) program plan and would serve as a means to facilitate transfer of safeguards technologies from the laboratory to an operational environment. New detectors and detector materials open the possibility of operating in a more efficient and cost effective manner, thereby strengthening national and international safeguards objectives. In particular, such detectors could serve the DOE and IAEA in improving timeliness of detection, minimizing uncertainty and improving confidence in results. SRNL's concept for the H Canyon test bed program would eventually open the facility to other DOE National Laboratories and establish a program for testing national and international safeguards related equipment. The initial phase of the test bed program is to conduct a comprehensive feasibility study to determine the benefits and challenges associated with establishing such a test bed. The feasibility study will address issues related to the planning, execution, and operation of the test bed program. Results from the feasibility study will be summarized and discussed in this paper.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of a Massive, Highly Multiplexible, Phonon-Mediated Particle Detector Using Kinetic Inductance Detectors

Here, we present a status update on the development of a phonon-mediated particle detector using kinetic inductance detector (KID). The design is intended for \(\mathscr {O}(1)\) kg substrate, using \(\mathscr {O}(10^{2})\) KIDs on a single readout line, to image the athermal phonon distribution at < 1 mm position resolution and \(\mathscr {O}(10)\) eV energy resolution. The design specification is set by the need to improve position reconstruction fidelity while maintaining low energy threshold for future rare-event searches such as for low-mass dark matter. Furthermore, we report on the design, which shows negligible crosstalk and > 95% inductor current uniformity, using the coplanar waveguide feedline, ground shield, and a new class of KIDs with symmetric coplanar stripline (sCPS) inductor. The multiplexing is designed upon the frequency-geometry relation we develop for the sCPS KIDs. We introduce the fabrications of the Nb RF assessment prototypes and the high phonon collection efficiency Al–Nb devices. We achieve \(\lesssim \) 0.07% frequency displacement on a 80-KID RF assessment prototype, and the result indicates that we may place more than 180 resonances in our 0.4 GHz readout band with minimal frequency misordering. The coupling quality factors are \(\sim \) 10 \(^{5}\) as designed. Finally, we update our work in progress in fabricating the \(\mathscr {O}(10^{2})\) KID, bi-material, \(\mathscr {O}(1)\) kg detectors, and the expected position and energy resolutions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance in beam tests of irradiated Low Gain Avalanche Detectors for the ATLAS High Granularity Timing Detector

The High Granularity Timing Detector (HGTD) will be installed in the ATLAS detector to mitigate pile-up effects during the High Luminosity (HL) upgrade of the Large Hadron Collider (LHC) at CERN. The design of the HGTD is based on the use of Low Gain Avalanche Detectors (LGADs), with an active thickness of 50 μm, that allow to measure with high-precision the time of arrival of particles. The HGTD will improve the particle-vertex assignment by measuring the track time with a resolution ranging from approximately 30 ps at the beginning of the HL-LHC operations to 50 ps at the end. Performances of several unirradiated, as well as neutron- and proton-irradiated, LGAD sensors from different vendors have been measured in beam test campaigns during the years 2018 and 2019 at CERN SPS and DESY. This paper presents the results obtained with data recorded by an oscilloscope synchronized with a beam telescope which provides particle position information within a resolution of a few μm. Collected charge, time resolution and hit efficiency are presented. In addition to these properties, the charge uniformity is also studied as a function of the position of the incident particle inside the sensor pad.

47 OTHER INSTRUMENTATION↗

Upgrading FLIR NanoRaider with the next Generation of CdZnTe Detectors. Goal - Integrate VFG detectors into FLIR R200. Advanced Virtual Grid ASIC (AVG-ASIC).

This document presents motivations, goals and the current status of this project; development (fabrication, performance) of position-sensitive virtual Frisch-grid detectors proposed for nanoRaider, an instrument commonly used by nuclear inspectors; ASIC developments for CZT detectors; and the electronics development for the detector prototype..

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of chlorination on the TlBr band edges for improved room temperature radiation detectors: Effect of chlorination on the TlBr band edges for radiation detectors

Thallium bromide (TlBr) crystals subjected to hydrochloric acid (HCl) chemical treatments have been shown to advantageously affect device performance and longevity in TlBr-based room temperature radiation detectors, yet the exact mechanisms of the improvements remain poorly understood. Here in this paper, we investigate the influence of several HCl chemical treatments on device-grade TlBr and describe the changes in the composition and electronic structure of the surface. Composition analysis and depth profiles obtained from secondary ion mass spectrometry (SIMS) identify the extent to which each HCl etch condition affects the detector surface region and forms of a graded TlBr/TlBr 1-x CL x surface heterojunction. Using a combination of X-ray photoemission spectroscopy (XPS) and hybrid density functional calculations, we are able to determine the valence band offsets, band gaps, and conduction band offsets as a function of Cl content over the entire composition range of TIBr 1-x C1 X . This study establishes a strong correlation between device process conditions, surface chemistry, and electronic structure with the goal of further optimizing the long-term stability and radiation response of TlBr-based detectors.

36 MATERIALS SCIENCE↗

Two-color detector: Mercury-cadmium-telluride as a terahertz and infrared detector

In this paper, issues associated with the development of infrared (IR) and terahertz (THz) radiation detectors based on HgCdTe are discussed. Two-color un-cooled and cooled to 78 K narrow-gap mercury-cadmium-telluride semiconductor thin layers with antennas were considered both as sub-THz (sub-THz) direct detection bolometers and 3–10 μm IR photoconductors. The noise equivalent power (NEP) for one of the detectors studied at ν ≈ 140 GHz reaches NEP{sub 300 K} ≈ 4.5 × 10{sup −10} W/Hz{sup 1/2} and NEP{sub 78 K} ≈ 5 × 10{sup −9} W/Hz{sup 1/2}. The same detector used as an IR photoconductor showed the responsivity at temperatures T = 78 K and 300 K with signal-to-noise ratio S/N ≈ 750 and 50, respectively, under illumination by using IR monochromator and globar as a thermal source.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The DarkSide Multiton Detector for the Direct Dark Matter Search

A wide range of astronomical evidence implies the existence of Dark Matter, but as yet the nature of this major component of the Universe is completely unknown. A leading candidate explanation is that Dark Matter is composed of Weakly Interacting Massive Particles (WIMPs) formed in the early universe and gravitationally clustered together with the standard baryonic matter. Such WIMPs could in principle be detected through their collisions with ordinary nuclei in a sensitive target, producing observable low-energy (<100 keV) nuclear recoils. The predicted collision rates are very low and require ultra-low background detectors with large (0.1 { 10 tons) target masses, located in deep underground sites to reduce the background produced by neutrons from cosmic ray muons [1{4].

Dark Matter↗

Development of a Versatile Array of Neutron Detectors at Low Energy

The Versatile Array of Neutron Detectors at Low Energy (VANDLE) is a new array of plastic scintillator bars under development for measurements at the Holifield Radioactive Ion Beam Facility at Oak Ridge National Laboratory. The array is highly modular allowing the configuration of the individual elements to be optimized for particular experimental requirements, such as (d,n) and beta-delayed neutron-decay measurements with neutron-rich rare isotope beams.

43 PARTICLE ACCELERATORS↗

Beam test measurements of Low Gain Avalanche Detector single pads and arrays for the ATLAS High Granularity Timing Detector

For the high luminosity upgrade of the LHC at CERN, ATLAS is considering the addition of a High Granularity Timing Detector (HGTD) in front of the end cap and forward calorimeters at (z) = 3.5 m and covering the region 2.4 < (Eta) < 4 to help reducing the effect of pile-up. The chosen sensors are arrays of 50 Mu-m thin Low Gain Avalanche Detectors (LGAD). This paper presents results on single LGAD sensors with a surface area of 1.3x1.3 mm2 and arrays with 2x2 pads with a surface area of 2x2 mm2 or 3x3 mm2 each and different implant doses of the p+ multiplication layer. They are obtained from data collected during a beam test campaign in autumn 2016 with a pion beam of 120 GeV energy at the CERN SPS. In addition to several quantities measured inclusively for each pad, the gain, efficiency and time resolution have been estimated as a function of the position of the incident particle inside the pad by using a beam telescope with a position resolution of few Mu-m. Different methods to measure the time resolution are compared, yielding consistent results. The sensors with a surface area of 1.3x1.3 mm 2 have a time resolution of about 40 ps for a gain of 20 and of about 27 ps for a gain of 50 and fulfill the HGTD requirements. Larger sensors have, as expected, a degraded time resolution. All sensors show very good efficiency and time resolution uniformity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Role of energy partitioning on electron-hole recombination, trapping, and detection in silicon detectors

The dynamics of electron-hole pair creation and transport in a semiconductor control the fundamental signal response for radiation detection. Extensive studies on silicon detectors have led to contradictory interpretations on the origins of the pulse height defect (PHD) and nonlinear response. In this study, recombination and trapping behaviors of a controlled number of electron-hole pairs produced within different volumes along the ion path are investigated, and the pulse height generated is analyzed in terms of energy partitioning. The results clearly demonstrate that a high recombination rate is not observed for heavy ions; moreover, significant trapping associated with the atomic defects produced by individual ions is responsible for the nonlinear response at low energies and PHD at high energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the top quark mass and pp{yields}tt cross section in the all-hadronic mode with the CDF II detector

We present a measurement of the top quark mass and of the top-antitop (tt) pair production cross section using pp data collected with the CDF II detector at the Tevatron Collider at the Fermi National Accelerator Laboratory and corresponding to an integrated luminosity of 2.9 fb{sup -1}. We select events with six or more jets satisfying a number of kinematical requirements imposed by means of a neural-network algorithm. At least one of these jets must originate from a b quark, as identified by the reconstruction of a secondary vertex inside the jet. The mass measurement is based on a likelihood fit incorporating reconstructed mass distributions representative of signal and background, where the absolute jet energy scale (JES) is measured simultaneously with the top quark mass. The measurement yields a value of 174.8{+-}2.4(stat+JES){sub -1.0}{sup +1.2}(syst) GeV/c{sup 2}, where the uncertainty from the absolute jet energy scale is evaluated together with the statistical uncertainty. The procedure also measures the amount of signal from which we derive a cross section, {sigma}{sub tt}=7.2{+-}0.5(stat){+-}1.0(syst){+-}0.4(lum) pb, for the measured values of top quark mass and JES.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inclusive Search for Standard Model Higgs Boson Production in the WW Decay Channel Using the CDF II Detector

We present a search for standard model (SM) Higgs boson production using pp collision data at sq root(s)=1.96 TeV, collected with the CDF II detector and corresponding to an integrated luminosity of 4.8 fb{sup -1}. We search for Higgs bosons produced in all processes with a significant production rate and decaying to two W bosons. We find no evidence for SM Higgs boson production and place upper limits at the 95% confidence level on the SM production cross section ({sigma}{sub H}) for values of the Higgs boson mass (m{sub H}) in the range from 110 to 200 GeV. These limits are the most stringent for m{sub H}>130 GeV and are 1.29 above the predicted value of {sigma}{sub H} for m{sub H}=165 GeV.