Comparison of Infiltration Test Methods for Soil Health Assessment

Infiltration rate (IR) has been commonly used as a metric to evaluate soil quality and health. For the USDA Soil Quality Test Kit, a 15-cm (6-in) diameter (ID) cylinder is used to measure IR with 444 cm 3 (equivalent to 2.54 cm or 1 in) of water while other standard IR procedures require substantially larger volumes of water. The general objective of this study was to compare different methods for IR measurement. Using three replications, IR measurements were conducted along a 9-m (27-ft) long transect in two different soil types by the double-ring infiltrometer (DRI) using 25- and 50-cm (10-and 20-in, respectively) cylinders, single-ring infiltrometer (SRI) using 25- and 50-cm cylinders, Cornell sprinkle infiltrometer (CSI) using a 24.1-cm (9.5-in) cylinder, the USDA recommended procedure using a 15-cm diameter cylinder (hereafter referred to as USDA-15 method), and a modified USDA method using a 24.1-cm diameter cylinder. Although the USDA-15 method is simple and requires a small amount of water, based on high variability among replications and significant reduction in IR during early stages of water entry into the soil, the procedure does not offer an accurate estimate of the soil infiltration potential. The CSI procedure was reproducible, but it is more cumbersome to perform than other methods. The DRI, SRI, and CSI methods required a much greater volume of water than the USDA-15 method but produced results that are more consistent. The most consistent results were obtained by the CSI and DRI methods. The modified USDA method results were similar to the SRI method and were an improvement over the original USDA-15 method. For assessing soil health, additional investigations should be conducted to evaluate a modified version of the USDA procedure using a larger cylinder.

54 ENVIRONMENTAL SCIENCES↗

Effects of molybdenum and silver on iodine transport in primary circuit on severe nuclear accidents

This experimental study was a continuation of the study conducted at VTT to investigate the effects of reactions on primary circuit surfaces to transport of gaseous and aerosol phase iodine during the hypothetical severe nuclear accident. Cesium iodide was used as a precursor in every experiment. In the experiments it was observed that the hydrogen in the atmosphere decreased the fraction of released gaseous iodine. As the temperature was lowered, less iodine was released, but the fraction of gaseous iodine from the overall released iodine was increased. As molybdenum trioxide was introduced to the precursor, the fraction of gaseous iodine from the overall released iodine was increased significantly. Also, Mo decreased the transport of Cs and caused significant depositions to the reaction furnace. Addition of silver to the CsI precursor at 650 deg. C decreased the release of iodine as well as the fraction of gaseous iodine. At 400 deg. C, Ag + CsI as well as Ag + MoO{sub 3} + CsI precursor significantly increased the release of gaseous iodine, where almost no aerosol particles were released. With B{sub 2}O{sub 3} + CsI precursor it was observed that in the atmosphere without H{sub 2}O, the released iodine was mostly in gaseous form. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GIS Supported Optimal Site Selection for Coastal Structure Integrated Wave Energy Converters: Preprint

There is an urgent need for adaptative engineering towards more resilient coastal communities, and Coastal Structure Integrated Wave Energy Converters (CSI-WECs) are a promising solution. CSI-WECs are wave energy converters (WECs) that are built into coastal protection structures, such as breakwaters. These devices provide the dual benefits of coastal protection and local energy production, and unlike other WECs, maximizing energy production is not always the main objective. CSI-WECs are located near the shore, where the wave resource is lower, thus site selection for these devices differs from the typical offshore WECs. Other attributes of a site that may be more important than wave power include existing coastal structures, port proximity, electric transmission line proximity, and location of disadvantaged communities. Geospatial information systems (GIS) interfaces can be used to easily visualize geospatial data that represents these difference kinds of criteria important for the determination of optimal marine energy sites. Multi-Criteria Decision Analysis (MCDA) is a geospatial analysis method that allows for the evaluation of multiple, usually overlapping, criteria. This project applies GIS-based MCDA methods to two distinct case studies in Puerto Rico and California for CSI-WEC site selection. The two study sites contrast in terms of wave resource, coastal hazards, and local energy needs. This research demonstrates the utility of applying an MCDA framework within GIS to facilitate efficient site selection for devices with unique characteristics in different use cases.

coastal protection↗

RADIATION DETECTION CHALLENGES

Pacific Northwest National Laboratory (PNNL) is a key part in the international community in the detection of radioxenon. PNNL’s design of radioxenon detection systems have resulted in the need for multiple sources to be capable of producing high quality NaI and CsI well detectors. Testing of NaI and CsI detectors from multiple manufactures has resulted in the discovery of two issues. First, there is potential for a dead layer, due to the manufacturer handling of the crystal, to be present on both the CsI and NaI crystals. The second issue is an energy drift caused by incorrect mating of PMT and PMT base to the crystal. These two issues cause adverse effects on the measurement of radioxenon or any other radiological measurement. It is clear that additional handling and inspection procedures are necessary during the manufacturing process. This paper will discuss the matter in more detail and give evidence of the presence of these issues in PNNL purchased crystals. The paper will also propose procedures for handling and testing to high quality CsI and NaI crystals get delivered on future purchases.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Radiation Dose to the Lens During Craniospinal Irradiation-An Improvement in Proton Radiotherapy Technique

Purpose: To evaluate the effect of angle modification of cranial field proton beam therapy on the radiation dose delivered to the lens during craniospinal irradiation (CSI). Methods and Materials: Thirty-nine patients with central nervous system tumors who received CSI with a posterior fossa boost were analyzed for the radiation dose to the lens. Thirteen patients received cranial field treatment using standard opposed-lateral proton beams, and 26 patients received treatment with angled posterior-oblique proton beams. The lens dose in a test case also was evaluated by comparing conventional X-rays with the two proton beam planning methods by using a CMS/Xio three-dimensional planning system. Results: Substantial lens dose sparing was realized with the angling of the cranial proton beams 15{sup o}-20{sup o} to the posterior. In the 39 treated patients who were analyzed (median age, 7 years), average dose delivered to the lens was decreased by approximately 50% by angling of the proton beams, with the average maximum dose decreasing from 74% to 40% of the prescribed dose (p < 0.0001). Significant lens sparing was seen in patients 10 years and younger (median age, 6 years; p < 0.0001), whereas an insignificant decrease was seen in older patients (median age, 16 years; p = 0.14). With the opposed-lateral technique (median age, 6 years), the lens dose increased significantly with decreasing age (p = 0.002), whereas there was no effect of age on lens dose in the angled beam-treated group (median age, 8.5 years; p = 0.73). Conclusion: The present study clearly shows an advantage in sparing of the lens dose by angling the beams used during proton beam CSI. This effect is most pronounced in patients 10 years and younger because of anatomic effects of sinus development.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

No Salvage Using High-Dose Chemotherapy Plus/Minus Reirradiation for Relapsing Previously Irradiated Medulloblastoma

Purpose: Myeloablative regimens were frequently used for medulloblastoma relapsing after craniospinal irradiation (CSI): in 1997-2002, we used repeated surgery, standard-dose and myeloablative chemotherapy, and reirradiation. Methods and Materials: In 10 patients, reinduction included sequential high-dose etoposide, high-dose cyclophosphamide/vincristine, and high-dose carboplatin/vincristine, then two myeloablative courses with high-dose thiotepa ({+-} carboplatin); 6 other patients received two of four courses of cisplatin/etoposide. Hematopoietic precursor mobilization followed high-dose etoposide or high-dose cyclophosphamide or cisplatin/etoposide therapy. After the overall chemotherapy program, reirradiation was prescribed when possible. Results: Seventeen patients were treated: previous treatment included CSI of 19.5-36 Gy with posterior fossa/tumor boost and chemotherapy in 16 patients. Fifteen patients were in their first and 2 in their second and third relapses, respectively. First progression-free survival had lasted a median of 26 months. Relapse sites included leptomeninges in 9 patients, spine in 4 patients, posterior fossa in 3 patients, and brain in 1 patient. Three patients underwent complete resection of recurrence, and 10 underwent reirradiation. Twelve of 14 patients with assessable tumor had an objective response after reinduction; 2 experienced progression and were not given the myeloablative courses. Remission lasted a median of 16 months. Additional relapses appeared in 13 patients continuing the treatment. Fifteen patients died of progression and 1 died of pneumonia 13 months after relapse. The only survivor at 93 months had a single spinal metastasis that was excised and irradiated. Survival for the series as a whole was 11-93 months, with a median of 41 months. Conclusions: Despite responses being obtained and ample use of surgery and reirradiation, second-line therapy with myeloablative schedules was not curative, barring a few exceptions. A salvage therapy for medulloblastoma after CSI still needs to be sought.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity Modulated Proton Therapy for Craniospinal Irradiation: Organ-at-Risk Exposure and a Low-Gradient Junctioning Technique

Purpose: To compare field junction robustness and sparing of organs at risk (OARs) during craniospinal irradiation (CSI) using intensity modulated proton therapy (IMPT) to conventional passively scattered proton therapy (PSPT). Methods and Materials: Ten patients, 5 adult and 5 pediatric patients, previously treated with PSPT-based CSI were selected for comparison. Anterior oblique cranial fields, using a superior couch rotation, and posterior spinal fields were used for IMPT planning. To facilitate low-gradient field junctioning along the spine, the inverse-planning IMPT technique was divided into 3 stages. Dose indices describing target coverage and normal tissue dose, in silico error modeling, and film dosimetry were used to assess plan quality. Results: Field junction robustness along the spine was improved using the staged IMPT planning technique, reducing the worst case impact of a 4-mm setup error from 25% in PSPT to <5% of prescription dose. This was verified by film dosimetry for clinical delivery. Exclusive of thyroid dose in adult patients, IMPT plans demonstrated sparing of organs at risk as good or better than PSPT. Coverage of the cribriform plate for pediatric (V95% [percentage of volume of the target receiving at least 95% of the prescribed dose]; 87 ± 11 vs 92 ± 7) and adult (V95%; 94 ± 7 vs 100 ± 1) patients and the clinical target in pediatric (V95%; 98 ± 2 vs 100 ± 1) and adult (V95%; 100 ± 1 vs 100 ± 1) patients for PSPT and IMPT plans, respectively, were comparable or improved. For adult patients, IMPT target dose inhomogeneity was increased, as determined by heterogeneity index (HI) and inhomogeneity coefficient (IC). IMPT lowered maximum spinal cord dose, improved spinal dose homogeneity, and reduced exposure to other OARs. Conclusions: IMPT has the potential to improve CSI plan quality and the homogeneity of intrafractional dose at match lines. The IMPT approach developed may also simplify treatments and reduce workload per patient relative to PSPT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Outcomes Among Children With Standard-Risk Medulloblastoma Treated With Proton and Photon Radiation Therapy: A Comparison of Disease Control and Overall Survival

Purpose: The purpose of this study was to compare long-term disease control and overall survival between children treated with proton and photon radiation therapy (RT) for standard-risk medulloblastoma. Methods and Materials: This multi-institution cohort study includes 88 children treated with chemotherapy and proton (n=45) or photon (n=43) RT between 2000 and 2009. Overall survival (OS), recurrence-free survival (RFS), and patterns of failure were compared between the 2 cohorts. Results: Median (range) age was 6 years old at diagnosis (3-21 years) for proton patients versus 8 years (3-19 years) for photon patients (P=.011). Cohorts were similar with respect to sex, histology, extent of surgical resection, craniospinal irradiation (CSI) RT dose, total RT dose, whether the RT boost was delivered to the posterior fossa (PF) or tumor bed (TB), time from surgery to RT start, or total duration of RT. RT consisted of a median (range) CSI dose of 23.4 Gy (18-27 Gy) and a boost of 30.6 Gy (27-37.8 Gy). Median follow-up time is 6.2 years (95% confidence interval [CI]: 5.1-6.6 years) for proton patients versus 7.0 years (95% CI: 5.8-8.9 years) for photon patients. There was no significant difference in RFS or OS between patients treated with proton versus photon RT; 6-year RFS was 78.8% versus 76.5% (P=.948) and 6-year OS was 82.0% versus 87.6%, respectively (P=.285). On multivariate analysis, there was a trend for longer RFS with females (P=.058) and higher CSI dose (P=.096) and for longer OS with females (P=.093). Patterns of failure were similar between the 2 cohorts (P=.908). Conclusions: Disease control with proton and photon radiation therapy appears equivalent for standard risk medulloblastoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-modulated radiation therapy and volumetric-modulated arc therapy for adult craniospinal irradiation—A comparison with traditional techniques

Craniospinal irradiation (CSI) poses a challenging planning process because of the complex target volume. Traditional 3D conformal CSI does not spare any critical organs, resulting in toxicity in patients. Here the dosimetric advantages of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) are compared with classic conformal planning in adults for both cranial and spine fields to develop a clinically feasible technique that is both effective and efficient. Ten adult patients treated with CSI were retrospectively identified. For the cranial fields, 5-field IMRT and dual 356° VMAT arcs were compared with opposed lateral 3D conformal radiotherapy (3D-CRT) fields. For the spine fields, traditional posterior-anterior (PA) PA fields were compared with isocentric 5-field IMRT plans and single 200° VMAT arcs. Two adult patients have been treated using this IMRT technique to date and extensive quality assurance, especially for the junction regions, was performed. For the cranial fields, the IMRT technique had the highest planned target volume (PTV) maximum and was the least efficient, whereas the VMAT technique provided the greatest parotid sparing with better efficiency. 3D-CRT provided the most efficient delivery but with the highest parotid dose. For the spine fields, VMAT provided the best PTV coverage but had the highest mean dose to all organs at risk (OAR). 3D-CRT had the highest PTV and OAR maximum doses but was the most efficient. IMRT provides the greatest OAR sparing but the longest delivery time. For those patients with unresectable disease that can benefit from a higher, definitive dose, 3D-CRT–opposed laterals are the most clinically feasible technique for cranial fields and for spine fields. Although inefficient, the IMRT technique is the most clinically feasible because of the increased mean OAR dose with the VMAT technique. Quality assurance of the beams, especially the junction regions, is essential.

61 RADIATION PROTECTION AND DOSIMETRY↗

A single-gradient junction technique to replace multiple-junction shifts for craniospinal irradiation treatment

Craniospinal irradiation (CSI) requires abutting fields at the cervical spine. Junction shifts are conventionally used to prevent setup error–induced overdosage/underdosage from occurring at the same location. This study compared the dosimetric differences at the cranial-spinal junction between a single-gradient junction technique and conventional multiple-junction shifts and evaluated the effect of setup errors on the dose distributions between both techniques for a treatment course and single fraction. Conventionally, 2 lateral brain fields and a posterior spine field(s) are used for CSI with weekly 1-cm junction shifts. We retrospectively replanned 4 CSI patients using a single-gradient junction between the lateral brain fields and the posterior spine field. The fields were extended to allow a minimum 3-cm field overlap. The dose gradient at the junction was achieved using dose painting and intensity-modulated radiation therapy planning. The effect of positioning setup errors on the dose distributions for both techniques was simulated by applying shifts of ± 3 and 5 mm. The resulting cervical spine doses across the field junction for both techniques were calculated and compared. Dose profiles were obtained for both a single fraction and entire treatment course to include the effects of the conventional weekly junction shifts. Compared with the conventional technique, the gradient-dose technique resulted in higher dose uniformity and conformity to the target volumes, lower organ at risk (OAR) mean and maximum doses, and diminished hot spots from systematic positioning errors over the course of treatment. Single-fraction hot and cold spots were improved for the gradient-dose technique. The single-gradient junction technique provides improved conformity, dose uniformity, diminished hot spots, lower OAR mean and maximum dose, and one plan for the entire treatment course, which reduces the potential human error associated with conventional 4-shifted plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

NO 2 -mediated voloxidation for iodine separation from cesium iodide surrogates

Heterogeneous NO 2 -mediated oxidation of uranium, also known as advanced voloxidation, is a proposed head-end reprocessing method for used nuclear fuel. An advantage of advanced voloxidation is the removal of volatile fission products, which complicate downstream separation and containment challenges leading to increased processing economics. Iodine, one of the volatile species of interest, has exhibited varied results in this process. Using CsI as a surrogate material, this work mimics the effect of NO 2 -based voloxidation on iodine and sheds light on the factors that influence the solid–gas phase reaction. Solid-state analysis using Fourier transform infrared attenuated total reflectance spectroscopy and scanning electron microscopy with energy-dispersive X-ray spectroscopy confirmed the conversion of CsI to CsNO 3 . Iodine separation ranged from 46% to 100% across multiple tests. Iodine separation was most effective when multiple recharges of NO 2 were administered. In conclusion, at the bench scale, liberating iodine from CsI appears to occur within 1 h, but the presence of surface H 2 O and the composition of the NO x reagent mixtures greatly influence its success.

advanced voloxidation↗

Un-collimated single-photon imaging system for high-sensitivity small animal and plant imaging

In preclinical single-photon emission computed tomography (SPECT) system development the primary objective has been to improve spatial resolution by using novel parallel-hole or multi-pinhole collimator geometries. Furthermore, such high-resolution systems have relatively poor sensitivity (typically 0.01% to 0.1%). In contrast, a system that does not use collimators can achieve very high-sensitivity. Here we present a high-sensitivity un-collimated detector single-photon imaging (UCD-SPI) system for the imaging of both small animals and plants. This scanner consists of two thin, closely spaced, pixelated scintillator detectors that use NaI(Tl), CsI(Na), or BGO. The performance of the system has been characterized by measuring sensitivity, spatial resolution, linearity, detection limits, and uniformity. With 99m Tc (140 keV) at the center of the field of view (20 mm scintillator separation), the sensitivity was measured to be 31.8% using the NaI(Tl) detectors and 40.2% with CsI(Na). The best spatial resolution (FWHM when the image formed as the geometric mean of the two detector heads, 20 mm scintillator separation) was 19.0 mm for NaI(Tl) and 11.9 mm for CsI(Na) at 140 keV, and 19.5 mm for BGO at 1116 keV, which is somewhat degraded compared to the cm-scale resolution obtained with only one detector head and a close source. The quantitative accuracy of the system’s linearity is better than 2% with detection down to activity levels of 100 nCi. Two in vivo animal studies (a renal scan using 99m Tc MAG-3 and a thyroid scan with 123 I) and one plant study (a 99m TcO 4 - xylem transport study) highlight the unique capabilities of this UCD-SPI system. From the renal scan, we observe approximately a one thousand-fold increase in sensitivity compared to the Siemens Inveon SPECT/CT scanner. In conclusion, UCD-SPI is useful for many imaging tasks that do not require excellent spatial resolution, such as high-throughput screening applications, simple radiotracer uptake studies in tumor xenografts, dynamic studies where very good temporal resolution is critical, or in planta imaging of radioisotopes at low concentrations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A novel diamond-like carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timinggaseous detector based on a MM detector operating in a two-stageamplification mode and a Cherenkov radiator. Prototypes equippedwith cesium iodide (CsI) photocathodes have shown promising timeresolutions as precise as 24 picoseconds (ps) for Minimum IonizingParticles. However, due to the high hygroscopicity andsusceptibility to ion bombardment of the CsI photocathodes,alternative photocathode materials are needed to improve therobustness of PICOSEC MM. Diamond-like Carbon (DLC) film have beenintroduced as a novel robust photocathode material, which have shownpromising results. A batch of DLC photocathodes with differentthicknesses were produced and evaluated using ultraviolet light. Thequantum efficiency measurements indicate that the optimizedthickness of the DLC photocathode is approximately3 nm. Furthermore, DLC photocathodes show good resistance to ionbombardment in aging test compared to the CsI photocathode. Finally,a PICOSEC MM prototype equipped with DLC photocathodes was tested inmuon beams. A time resolution of around 42 ps with a detectionefficiency of 97% for 150 GeV/c muons were obtained. These resultsindicate the great potential of DLC as a photocathode for thePICOSEC MM detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct detection of sub-GeV dark matter with scintillating targets

We suggest a novel experimental concept for detecting MeV-to-GeV-mass dark matter, in which the dark matter scatters off electrons in a scintillating target and produces a signal of one or a few photons. New large-area photodetectors are needed to measure the photon signal with negligible dark counts, which could be constructed from transition edge sensor (TES) or microwave kinetic inductance detector (MKID) technology. Alternatively, detecting two photons in coincidence may allow the use of conventional photodetectors like photomultiplier tubes. Here we describe why scintillators may have distinct advantages over other experiments searching for a low ionization signal from sub-GeV dark matter, as there are fewer potential sources of spurious backgrounds. We discuss various target choices, but focus on calculating the expected dark matter-electron scattering rates in three scintillating crystals: sodium iodide (NaI), cesium iodide (CsI), and gallium arsenide (GaAs). Among these, GaAs has the lowest band gap (1.52 eV) compared to NaI (5.9 eV) or CsI (6.4 eV), which in principle allows it to probe dark matter masses as low as ~0.5 MeV, compared to ~1.5 MeV with NaI or CsI. We compare these scattering rates with those expected in silicon (Si) and germanium (Ge). The proposed experimental concept presents an important complementary path to existing efforts, and its potential advantages may make it the most sensitive direct-detection probe of dark matter down to MeV masses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Silicon Photomultipliers Coupled to Scintillators With the Emission Maximum at 550 nm

A majority of the silicon photomultipliers (SiPMs) are sensitive to blue and near-ultraviolet (NUV) photons that are not optimized for scintillators with the emission maximum at wavelengths longer than 500 nm. The red–green–blue (RGB) SiPM is developed for the maximum photon detection efficiency (PDE) at 550 nm, which is a good match for some high-light-yield scintillators, such as CsI:Tl (CsI) and Gd 1.5 Y 1.5 Ga 2 Al 3 O 12 :Ce (GYGAG). Comparisons are made for the performance of these scintillators coupled to the RGB SiPM and a blue-sensitive SiPM. Because it takes tens of nanoseconds for the microcells to recharge after registering a photon hit, the linearity of these scintillation detectors was studied for high-energy gammas where numerous scintillation photons are generated. In addition, the energy resolution of the 662-keV gamma emitted by 137 Cs was measured for temperatures between –20 °C and 50 °C. The nonlinearity was observed above 1 MeV for all measurements, and however, it can be corrected by energy calibration using a third-degree polynomial. For CsI, the energy resolution is better with the blue-sensitive SiPM because of the lower dark count rate (DCR). In contrast, GYGAG coupled to the RGB SiPM has a better energy resolution for temperatures below 30 °C because of the well-matched emission spectrum and PDE distribution. Nevertheless, the advantage disappears for temperatures above 30 °C due to the higher DCR. It would be useful to further develop the RGB SiPM with a lower DCR and higher operating temperatures.

42 ENGINEERING↗

Oblique incidence effects in direct x-ray detectors: A first-order approximation using a physics-based analytical model

Purpose: The authors describe the modifications to a previously developed analytical model of indirect CsI:Tl-based detector response required for studying oblique x-ray incidence effects in direct semiconductor-based detectors. This first-order approximation analysis allows the authors to describe the associated degradation in resolution in direct detectors and compare the predictions to the published data for indirect detectors. Methods: The proposed model is based on a physics-based analytical description developed by Freed et al. [''A fast, angle-dependent, analytical model of CsI detector response for optimization of 3D x-ray breast imaging systems,'' Med. Phys. 37(6), 2593-2605 (2010)] that describes detector response functions for indirect detectors and oblique incident x rays. The model, modified in this work to address direct detector response, describes the dependence of the response with x-ray energy, thickness of the transducer layer, and the depth-dependent blur and collection efficiency. Results: The authors report the detector response functions for indirect and direct detector models for typical thicknesses utilized in clinical systems for full-field digital mammography (150 {mu}m for indirect CsI:Tl and 200 {mu}m for a-Se direct detectors). The results suggest that the oblique incidence effect in a semiconductor detector differs from that in indirect detectors in two ways: The direct detector model produces a sharper overall PRF compared to the response corresponding to the indirect detector model for normal x-ray incidence and a larger relative increase in blur along the x-ray incidence direction compared to that found in indirect detectors with respect to the response at normal incidence angles. Conclusions: Compared to the effect seen in indirect detectors, the direct detector model exhibits a sharper response at normal x-ray incidence and a larger relative increase in blur along the x-ray incidence direction with respect to the blur in the orthogonal direction. The results suggest that the oblique incidence effect in direct detectors can be considered to be caused mostly by the geometry of the path where the x-ray beam and its secondary particles deposit energy in the semiconductor layer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overestimations in zero frequency DQE of x-ray imaging converters assessed by Monte Carlo techniques based on the study of energy impartation events

Purpose: The performance of various x-ray converters, employed in medical imaging systems, has been widely examined by several methodologies (experimental, analytical, and Monte Carlo techniques). The x-ray converters most frequently employed in energy integrating digital radiology detectors are the Gd{sub 2}O{sub 2}S:Tb granular phosphor, the CsI:Tl structured phosphor, and the a-Se photoconductor. The imaging characteristics of an x-ray converter are affected by its x-ray detection properties. However, various definitions of x-ray detection have been used in the literature, leading to different results for the quantum detection efficiency (QDE) for the same type of x-ray converter. For this reason, there is a need for accurate determination of the x-ray detection and, in particular, its relation to detector response. Methods: The present article reports on the performance of the three aforementioned x-ray converters in terms of the QDE and the x-ray statistical factor I{sub x} and examines the effect of the x-ray detection, directly related to converter output signal, on the zero-frequency DQE. For the purposes of this study, Monte Carlo simulation was used to model the x-ray interactions within the x-ray converter. Simulations were carried out in the energy range from 10 keV up to 80 keV and considering two layers of different coating weights (50 and 100 mg/cm{sup 2}). The prediction and comparison of zero-frequency DQE were based on two different approaches for x-ray detection, i.e., (a) fraction of interacting photons and (b) fraction of photons leading to energy deposition. In addition, the effect of energy deposition through Compton scattering events on the DQE values was estimated. Results: Our results showed discrepancies between Monte Carlo techniques (based on energy deposition events) and analytical calculations (based on x-ray attenuation) on QDE. Discrepancies were found to range up to 10% for Gd{sub 2}O{sub 2}S:Tb (100 mg/cm{sup 2}), 7.7% for CsI:Tl (50 mg/cm{sup 2}), and 8.2% for a-Se (50 mg/cm{sup 2}). Discrepancies were analyzed by examining the scattering effects (elastic and inelastic) within the converters and led to further analysis of scattering events on I{sub x} as well. Significant overestimations were found for both factors (QDE and I{sub x}) on the zero-frequency DQE. Conclusions: Considering that the highest overestimation was found in the thin layer (50 mg/cm{sup 2}), Monte Carlo evaluation showed that the overestimation (%) between DQE values (based on either x-ray interacting events or energy impartation events) was more significant at 20 keV for CsI:Tl (approximately 2.1%), at 40 keV for Gd{sub 2}O{sub 2}S:Tb (approximately 8.1%), and finally at 60 and 80 keV for a-Se converter (approximately 4.8 and 8.2%, respectively). Finally, the overestimation due to the effect of Compton scattering on DQE was found more significant for the a-Se converter and especially above 40 keV reaching approximately the value of 8.9% at 80 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗