Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cryogenic Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Integration of Silica in G4CMP for Phonon Simulations: Framework and Tools for Material Integration

Superconducting detectors with sub-eV energy resolution have demonstrated success setting limits on Beyond the Standard Model (BSM) physics due to their unique sensitivity to low-energy events. G4CMP, a Geant4-based extension for condensed matter physics, provides a comprehensive toolkit for modeling phonon and charge dynamics in cryogenic materials. This paper introduces a technical formalism to support the superconducting qubit and low-threshold detector community in implementing phonon simulations in custom materials into the G4CMP. As a case study, we present the results of a detailed analysis of silica phonon transport properties relevant for simulating substrate backgrounds in Beryllium Electron capture in Superconducting Tunnel junctions (BeEST)-style experiments using G4CMP. Additionally, Python-based tools were developed to aid users in implementing their own materials and are available on the G4CMP repository.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-energy calibration of SuperCDMS HVeV cryogenic silicon calorimeters using Compton steps

Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. Here, we demonstrate a successful use of Compton steps for sub-keV calibration of cryogenic silicon calorimeters, utilizing four SuperCDMS High-Voltage eV-resolution detectors operated with 0 V bias across the crystal. This new calibration at 0 V is compared with the established high-voltage calibration using optical photons. The comparison indicates that the detector response at 0 V is about 30% weaker than expected, highlighting challenges in detector response modeling for low-mass dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensitive neutron transverse polarization analysis using a 3 He spin filter

Here we report an experimental implementation for neutron transverse polarization analysis that is capable of detecting a small angular change ($\ll$10 –3 rad) in neutron spin orientation. This approach is demonstrated for monochromatic beams, and we show that it could be extended to polychromatic neutron beams. Our approach employs a 3 He spin filter inside a solenoid with an analyzing direction perpendicular to the incident neutron polarization direction. The method was tested with polarized neutron beams and a spin rotator placed inside a μ -metal shield just upstream of the analyzer. No cryogenic superconducting shields or additional neutron spin manipulations are needed. With a counting detector, we experimentally show that the angular resolution δ θ = 1 / ( P n A N ) rad is only determined by the counting statistics for the total counts N and the product of the neutron polarization P n and the analyzing power A . With a high-flux neutron beam, 10 –6 rad angular sensitivity is feasible within a day. This simple, classical-quantum-limited transverse polarization analysis scheme may reduce the overall complexity of experimental implementation for applications requiring sensitive neutron polarimetry and improve the precision in fundamental science studies and polarized neutron imaging.

47 OTHER INSTRUMENTATION↗

Characterizing and Modeling the Influence of Geometry on the Performance of Superconducting Nanowire Cryotrons

The scaling of superconducting nanowire detectors to larger arrays is often limited by room-temperature-readout cabling. Cryogenic integrated circuits constructed from nanowire cryotrons, or nanocryotrons, can address this limitation by performing signal processing on chip. In this study, we characterize key performance metrics of the nanocryotron to elucidate its potential as a logical element in cryogenic integrated circuits and develop an electro-thermal model to connect material parameters with device performance. We find that the performance of the nanocryotron depends on the device geometry, and trade-offs are associated with optimizing the gain, jitter, and energy dissipation. Here, we demonstrate that nanocryotrons fabricated on niobium nitride can achieve a grey zone less than 210 nA wide for a 5 ns long input pulse corresponding to a maximum achievable gain of 48 dB, an energy dissipation of less than 20 aJ per operation, and a jitter of less than 60 ps.

Superconductor↗

Cryogenic Platforms at Fermilab: Recent Results and Outlook

The Cosmic Quantum group at Fermilab operates three cryogenic facilities dedicated to the development and calibration of superconducting low-threshold detectors and qubits. One of which (LOUD) is located at the surface, while the other two (NEXUS and QUIET) are located 100 m underground enabling low-background device characterization and rare event searches. Recently, we have demonstrated world-leading resolution in the quasiparticle channel for kinetic inductance phonon-mediated detectors as well as the lowest rate of spatially- and temporally- correlated errors ( charge jumps ) in superconducting qubit chips. We have additionally made significant progress in expanding the suite of tools for simulating signal production and readout of these devices. In this talk, I will review these recent results, discuss some nascent projects focused on enhancing sensitivity of these detectors to sub-GeV dark matter, and highlight activities in these facilities over the next year.

Temples, Dylan J.↗

Effect of an electric field on liquid helium scintillation produced by fast electrons

The dependence on applied electric field (0–40 kV/cm) of the scintillation light produced by fast electrons and α particles stopped in liquid helium in the temperature range of 0.44 K to 3.12 K is reported. For both types of particles, the reduction in the intensity of the scintillation signal due to the applied field exhibits an apparent temperature dependence. Using an approximate solution of the Debye-Smoluchowski equation, we show that the apparent temperature dependence for electrons can be explained by the time required for geminate pairs to recombine relative to the detector signal integration time. This finding indicates that the spatial distribution of secondary electrons with respect to their geminate partners possesses a heavy, non-Gaussian tail at larger separations and has a dependence on the energy of the primary ionization electron. Here, we discuss the potential application of this result to pulse shape analysis for particle detection and discrimination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of CdZnTeSe Nuclear Detector Chemically Etched in Bromine Methanol

Semiconductor nuclear radiation detectors made from tertiary and quaternary compounds of cadmium telluride (CdTe) can operate at room temperature without cryogenic cooling. One of such materials that have become of great interest is cadmium zinc telluride selenide (CdZnTeSe). Compared to other CdTe-based materials, such as cadmium zinc telluride (CdZnTe), CdZnTeSe can be grown with much less Te inclusions and sub-grain boundary networks. Chemical etching is often used to smoothen wafer surfaces during detector fabrication. This paper presents the characterization of CdZnTeSe that is chemically etched using bromine methanol solution. Infrared imaging shows that the wafer has no sub-grain boundary networks that often limit detector performance. The current-voltage (I-V) characterization experiment gave a resistivity of 4.6 × 10 10 Ω-cm for the sample. The I-V curve was linear in the ±10 to ±50 volts range. An energy resolution of 7.2% was recorded at 100 V for the 59.6-keV gamma line of 241 Am.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of interfacial structures on phonon transport across atomically precise Si/Al heterojunctions

Phonons are important carriers of energy and information in many cryogenic devices used for quantum information science and in fundamental physics experiments such as dark matter detectors. In these systems phonon behavior can be dominated by interfaces, hence there is increasing demand for a more detailed understanding of interfacial phonon transport in relevant material systems. Previous studies have focused on understanding thermal transport over the entire phonon spectrum at and above room temperature. At ultra-low temperatures, however, knowledge is missing regarding athermal phonon behavior due to the challenge in modeling the extreme conditions in micro-scale, heterogeneous cryogenic systems, as well as extracting single-phonon information from a large ensemble. In this work, we delineate interfacial phonon transport using a combination of classical molecular dynamics (MD) and phonon wave packet simulations, to illustrate the consistency and differences between the ensemble- and single-phonon dynamics. We consider three single-crystal Si surface reconstructions --- (1×1), (v3×v3) and (7×7) --- and model both experimentally observed Si(1×1)/Al interfaces and hypothesized Si(v3×v3)/Al and Si(7×7)/Al interfaces. The overall interfacial thermal conductance calculated from non-equilibrium MD shows that for the Si(1×1)/Al system, the presence of Al twin grain boundaries can hinder phonon transport and reduce thermal conductance by 2--12% relative to single-crystal Al; whereas the Si (v3×v3) and (7×7) reconstructions can enhance it by 6--19%. Normal mode decomposition reveals that both the increase and decrease in conductance are related to inelastic phonon scattering. Single-phonon wave packet simulations show results consistent with NEMD, while further suggesting that phonon polarization conversion is significant even when elastic transmission dominates, and that the interfacial structures have anisotropic impacts on atomic vibrations along different lattice directions. Our findings suggest alternative perspectives in achieving selective phonon transport through controlling interfacial structures of materials with atomically-precise fabrication techniques, and that the phonon wave packet formalism is a potentially powerful method for developing a detailed understanding of non-equilibrium phenomena in the low-temperature limit.

Lu, Zexi↗

Conceptual study of a two-layer silicon pixel detector to tag the passage of muons from cosmic sources through quantum processors

Abstract Recent studies in quantum computing have shown that quantum error correction with large numbers of physical qubits are limited by ionizing radiation from high-energy particles. Depending on the physical setup of the quantum processor, the contribution of muons from cosmic sources can constitute a significant fraction of these interactions. As most of these muons are difficult to stop, we perform a conceptual study of a two-layer silicon pixel detector to tag their hits on a solid-state quantum processor instead. With a typical dilution refrigerator geometry model, we find that efficiencies greater than 50% are most likely to be achieved if at least one of the layers is operated at the deep-cryogenic (<1 K) flanges of the refrigerator. Following this finding, we further propose a novel research program that could allow the development of silicon pixel detectors that are fast enough to provide input to quantum error correction algorithms, can operate at deep-cryogenic temperatures, and have very low power consumption.

Instruments & Instrumentation↗

CryoPDK Development for 22nm FDSOI CryoCMOS

Cryogenic Process Design Kits (PDKs) are an indispensable tool in the design of complex integrated circuits across a wide spectrum of applications, from noble element detectors to Quantum Information Science, Superconducting Nanowire Single Photon Detectors (SNSPDs), and precision atomic clocks. The development of PDK-compatible SPICE models is a complex endeavor requiring test structures, measurements, model extraction and fitting. We will present the cryogenic modeling and development of a cryo-PDK for a 22nm FDSOI CMOS process for operation at 3.8 Kelvin.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Power over fiber development for HEP detectors

Power-over-Fiber (PoF) technology has been used extensively in settings where high voltages require isolation from ground and electromagnetic isolation is critical. In cryogenic environments, PoF offers a reliable power transmission technology, leveraging optical fibers to transfer power with minimal system degradation. PoF technology excels in maintaining low noise levels and isolation when delivering power to sensitive electronic systems operating in extreme temperature ranges and high voltage environments. Here, in a novel application of PoF for a HEP detector, power is provided to photon detector modules located on a surface at ~300 kV with respect to ground in the planned DUNE experiment. This summary paper of the PoF talk at the 16th PISA Meeting on Advanced Detectors highlights the R&D effort of PoF in extreme conditions and underscores its capacity to revolutionize power delivery and management in critical applications offering a dependable solution with low noise, optimal efficiency, and superior isolation. The DUNE (Abi et al., 2020) experiment will soon deploy large liquid argon (LAr) time projection chambers (TPC) to detect neutrino interactions and other particle physics phenomena. In addition to the particle tracking provided by the TPC, photon detectors, powered by a first ever PoF system, in the cryostat will leverage the high scintillation light yield of LAr to provide crucial timing and additional calorimetric information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon Detection System Calibration for DUNE

Photon Detection System Calibration for DUNE Not scheduled 20m Conference Center (University of California, Irvine) Poster New Technologies for Neutrino Physics Poster session Speaker Denis Torres (South Dakota School of Mines and Technology) Description The Deep Underground Neutrino Experiment (DUNE) is a long baseline neutrino oscillation experiment that relies on a precise Photon Detection System (PDS) to provide accurate timing information, enhance sensitivity to low-energy and non-beam events, and support detector performance studies in liquid argon time projection chambers. Achieving these goals requires a well-understood and stable optical calibration strategy that operates reliably under cryogenic conditions. In this poster, I will present PDS calibration studies performed in ProtoDUNE, focusing on the characterization of the ultraviolet (UV) light calibration system and key optical components in the light-delivery chain. I will discuss measurements of optical fiber transmission, SMA-to-SMA connector and feedthrough interface losses, and diffuser assemblies, emphasizing wavelength dependence, attenuation, and performance under cryogenic thermal cycling and stability tests. These studies provide quantitative inputs for understanding light transport, uniformity, and long-term reliability of the PDS in large-scale liquid argon detectors, and they directly inform calibration strategies for the DUNE Far Detector.

Torres Muñoz, Denis [South Dakota Sch. Mines Tech.↗

Sub-2 Kelvin Characterization of Nitrogen-Vacancy Centers in Silicon Carbide Nanopillars

The development of efficient quantum communication technologies depends on the innovation in multiple layers of its implementation, a challenge we address from the fundamental properties of the physical system at the nanoscale to the instrumentation level at the macroscale. We select a promising near-infrared quantum emitter, the nitrogen-vacancy (NV) center in 4H-SiC, and integrate it, at an ensemble level, with nanopillar structures that enhance photon collection efficiency into an objective lens. Moreover, changes in collection efficiency in pillars compared to bulk can serve as indicators of color center orientation in the lattice. To characterize NV center properties at the unprecedented sub-2 K temperatures, we incorporate compatible superconducting nanowire single photon detectors inside the chamber of an optical cryostat and create the ICECAP, the Integrated Cryogenic system for Emission, Collection And Photon detection. ICECAP measurements show no significant line-width broadening of NV ensemble emission and up to 14-fold enhancement in collected emission. With additional filtering, we measure emitter lifetimes of NV centers in a basal ( hk ) and axial ( kk ) orientation, unveiling their cryogenic values of 2.2 and 2.8 ns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RHIC Recovery Review Report [See also: RHIC Recovery Review - Hybrid Meeting (11/28/2023) - Indico.bnl.gov]

Just after 12:30 PM on August 1, 2023, the RHIC superconducting magnet quench system triggered and consequently the energy dump resistors were switched into the blue ring quad and dipole circuits and the interaction region DX dipole heaters were switched on. This was a spurious trip (there was no actual quench) and was not unusual as the outdoor summer temperature often caused the quench detectors to cause such trips. The collider control room notified the on-duty cryogenics technical staff of the quench trip. A short time later building 1004B cryogenic low-helium and valve box insulation vacuum failure alarms were observed. The cryogenics technical staff observed the cryo-relief line from the blue ring valve box was exhausting helium outside the building.

43 PARTICLE ACCELERATORS↗

Single-photon detection using large-scale high-temperature MgB2 sensors at 20 K

Abstract Ultra-fast single-photon detectors with high current density and operating temperature can benefit space and ground applications, including quantum optical communication systems, lightweight cryogenics for space crafts, and medical use. Here we demonstrate magnesium diboride (MgB 2 ) thin-film superconducting microwires capable of single-photon detection at 1.55 μ m optical wavelength. We used helium ions to alter the properties of MgB 2 , resulting in microwire-based detectors exhibiting single-photon sensitivity across a broad temperature range of up to 20 K, and detection efficiency saturation for 1 μ m wide microwires at 3.7 K. Linearity of detection rate vs incident power was preserved up to at least 100 Mcps. Despite the large active area of up to 400 × 400 μ m 2 , the reset time was found to be as low as ~ 1 ns. Our research provides possibilities for breaking the operating temperature limit and maximum single-pixel count rate, expanding the detector area, and raises inquiries about the fundamental mechanisms of single-photon detection in high-critical-temperature superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

DC Cryogenic Modeling of Open-Source SkyWater 130 nm MOSFETs at 77 K Using BSIM4

Cryogenic applications in high-energy physics (HEP) demand reliable, low-power CMOS electronics capable of operating at liquid nitrogen temperatures (77 K). The open-source SkyWater 130nm (SKY130) CMOS process has previously been shown to operate at temperatures as low as 4 K making it a promising candidate for HEP applications. In this work, we characterize and model SKY130 low-threshold voltage transistors at 77 K, which is a temperature commonly used in modeling applications for liquid argon detectors. DC characteristic measurements were performed at both room temperature and liquid nitrogen temperature. We created a cryogenic modeling approach to produce a SPICE-compatible, isothermal BSIM4-based model for select transistor sizes at 77 K. The resulting model agrees with data at 77 K with an average error on the order of 20% (relative RMS) and shows no dependence on drain voltage. Due to the open-source nature of SKY130, we have made our models publicly available on Github. We hope this work will continue the trend for democratizing circuit design at cryogenic temperatures in high-energy physics by enabling open access to accurate cryogenic CMOS device models at 77 K.

Beall, F. [Texas U., Arlington]↗

Benchmarking the design of the cryogenics system for the underground argon in DarkSide-20k

DarkSide-20k (DS-20k) is a dark matter detection experimentunder construction at the Laboratori Nazionali del Gran Sasso (LNGS)in Italy. It utilises ∼ 100 t of low radioactivity argon from anunderground source (UAr) in its inner detector, with half serving astarget in a dual-phase time projection chamber (TPC). The UArcryogenics system must maintain stable thermodynamic conditionsthroughout the experiment's lifetime of over10 years. Continuous removal ofimpurities and radon from the UAr is essential for maximising signalyield and mitigating background. We are developing an efficient andpowerful cryogenics system with a gas purification loop with atarget circulation rate of1000 slpm. Central to itsdesign is a condenser operated with liquid nitrogen which is pairedwith a gas heat exchanger cascade, delivering a combined coolingpower of more than 8 kW. Here wepresent the design choices in view of the DS-20k requirements, inparticular the condenser's working principle and the coolingcontrol, and we show test results obtained with a dedicatedbenchmarking platform at CERN and LNGS. We find that the thermalefficiency of the recirculation loop, defined in terms of nitrogenconsumption per argon flow rate, is95 % and the pressure in the testcryostat can be maintained within±(0.1–0.2) mbar. Wefurther detail a 5-day cool-down procedure of the test cryostat,maintaining a cooling rate typically within-2 K/h, as required for theDS-20k inner detector. Additionally, we assess the circuit's flowresistance, and the heat transfer capabilities of two heat exchangergeometries for argon phase change, used to provide gas forrecirculation. We conclude by discussing how our findings influencethe finalisation of the system design, including necessarymodifications to meet requirements and ongoing testing activities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗