Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coupled resonators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

The Dynamics of Ultrasonically Levitated Drops in an Electric Field

Ultrasonic and electrostatic leviation techniques have allowed the experimental investigation of the nonlinear oscillatory dynamics of free droplets with diameter between 0.1 and 0.4 cm. The measurement of the resonance frequencies of the first three normal modes of large amplitude shape oscillations in an electric field of varying magnitude has been carried out with and without surface charges for weakly conducting liquids in air. These oscillations of nonspherical levitated drops have been driven by either modulating the ultrasonic field or by using a time-varying electric field, and the free decay from the oscillatory state has been recorded. A decrease in the resonance frequency of the driven fundamental quadrupole mode has been measured for increasing oblate deformation in the absence of an electric field. Similarly, a decrease in this frequency has also been found for increasing DC electric field magnitude. A soft nonlinearity exists in the amplitude dependence of the resonant mode frequencies for freely decaying as well as ultrasonically and electrically driven uncharged drops. This decrease in resonance frequency is accentuated by the presence of free surface charge on the drop. Subharmonic resonance excitation has been observed for drops in a time-varying electric field, and hysteresis exists for resonant modes driven to large amplitude. Mode coupling from lower-order resonances to higher-order modes has been found to be very weak, even for fairly large amplitude shape oscillations. Most of these results are in general agreement with predictions from recent analytical and numerical investigations.

Ultrasonically↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (.50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (approximately 50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of one the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Compact Dielectric-Rod White-Light Delay Lines

Optical delay lines of a proposed type would be made from rods of such dielectric materials as calcium fluoride, fused silica, or sapphire. These would offer advantages over prior optical delay lines, as summarized below. Optical delay lines are key components of opto-electronic microwave oscillators, narrow-band opto-electronic microwave filters, evanescent-field optical biochemical detectors, and some Fourier-Transform spectrum analyzers. Heretofore, optical delay lines used in such applications have been of two types: resonators and coiled long optical fibers, both of which have disadvantages: Resonators are compact, but excitation must be provided by narrow-band lasers. Wide-band (including noisy) laser light cannot be coupled efficiently to narrow-band resonators. When light is coupled into a narrowband resonator from a source of reasonably high power, a significant amount of optical energy circulates within the resonator, causing nonlinear loss and significant noise. Typically, a coil-type optical delay line is made of fused-silica fiber, which exhibits fundamental loss. To overcome the limit imposed by the optical loss in fused silica, it would be necessary to use fibers having crystalline cores. Although space is saved by winding fibers into coils, fiber-coil delay lines are still inconveniently bulky. The proposed compact dielectric-rod delay lines would exploit the special class of non-diffracting light beams that are denoted Bessel beams because their amplitudes are proportional to Bessel functions of the radii from their central axes. High-order Bessel beams can have large values of angular momentum. They can be generated with the help of whispering-gallery-mode optical resonators, as described, for example, in "Simplified Generation of High-Angular-Momentum Light Beams" (NPO-42965) NASA Tech Briefs, Vol. 31, No. 3 (March 2007), page 8a. In a delay line according to the proposal, the dielectric rod would be dimensioned to function as a multimode waveguide. Suitably chosen high-angular-momentum modes in such a waveguide exhibit low group velocity (hence, long delay) and no resonance. Such a delay line could perform well at any wavelength or range of wavelengths within the transparency wavelength band of the dielectric material, and the maximum possible group delay achievable through suitable design would be limited only by the optical loss in the rod material.

Maleki, Lute↗

A novel triaxial vibration test technique

The present work examines the circumstances under which simultaneous multiaxial vibration testing may be desirable, the testing techniques and equipment required to make it feasible, and the type of results that may be obtained together with some practical limitations to the techniques. Two schemes for performing vibration testing simultaneously or sequentially along three mutually perpendicular axes are considered and the most promising, involving a 'floating' technique, is presented in some detail. Practical problems associated with jig design and system resonances, cross-coupling between the various degrees of freedom, secondary loads on shaker elements, and system drift, are considered and workable solutions proposed. A simple simulation of multiaxial testing of a 1.1-pound inertia-simulated model of an Apollo command module is presented.

Wignot, J. E.↗

Techniques for Improving the Stability of Soft Inplane Hingeless Rotors

The influence of basic parameters that govern flap lag stability of hingeless rotor blades in hover is reviewed, and potential methods are studied for improving the lead lag damping of soft inplane configurations for low thrust conditions. These conditions are relevant for ground and air resonance stability of coupled rotor body dynamic systems. Results indicate that the isolated rotor blade lead lag damping can be usefully increased by a combination of flap lag elastic coupling and pitch lag coupling. For a typical soft inplane configuration, 6% of critical damping can be obtained for moderate pitch lag coupling. For large values of the coupling parameters, the lead lag frequency is substantially reduced at high pitch angles and airfoil stall effects also reduce the lead lag damping.

Ormiston, R. A.↗

Design, development and manufacture of a breadboard radio frequency mass gauging system

The feasibility of the RF gauging mode, counting technique was demonstrated for gauging liquid hydrogen and liquid oxygen under all attitude conditions. With LH2, it was also demonstrated under dynamic fluid conditions, in which the fluid assumes ever changing positions within the tank, that the RF gauging technique on the average provides a very good indication of mass. It is significant that the distribution of the mode count data at each fill level during dynamic LH2 and LOX orientation testing does approach a statistical normal distribution. Multiple space-diversity probes provide better coupling to the resonant modes than utilization of a single probe element. The variable sweep rate generator technique provides a more uniform mode versus time distribution for processing.

Source record↗

MHD conversion of solar energy

Low temperature plasmas wherein an alkali metal vapor is a component are uniquely suited to simultaneously absorb solar radiation by coupling to the resonance lines and produce electrical power by the MHD interaction. This work is an examination of the possibility of developing space power systems which take advantage of concentrated solar power to produce electricity. It is shown that efficient cycles in which expansion work takes place at nearly constant top cycle temperature can be devised. The power density of the solar MHD generator is lower than that of conventional MHD generators because of the relatively high seed concentration required for radiation absorption and the lower flow velocity permitted to avoid total pressure losses due to heating.

Lau, C. V.↗

Maser cavity servo-tuning system

Two collocated, weakly coupled probes, one loop and one dipole, detect the magnetic and electric fields inside a maser cavity. Signals from the probes are compared in phase, and the signal output from the phase detector is applied to a varactor, the reactance of which is coupled into the cavity by a microwave coupler. Alternatively, the varactor may be placed inside the cavity. Any deviation of phase from 90 deg as detected by the phase detector will then produce an error signal that will change the reactance coupled into the resonant cavity to change its reactance, and thus correct its resonance frequency. An alternative to using two probes is to use a single disk probe oriented to detect both the magnetic and electric fields, and thus provide the error signal directly.

Sydnor, R. L.↗

Oscillator strengths for S I, S II, and S III

A series of calculations for atomic data of various sulfur and oxygen ions is examined. Recent observations of the Io plasma torus obtained with the Voyager UV Spectrometer, the IUE satellite short wavelength spectrograph, and the rocket-borne faint object telescope are discussed. The calculation of oscillator strengths for S II, the P I sequence, S I, and S III in terms of configuration interaction effects is described. The derivation of orbital wave functions is considered. The use of the close coupling method to estimate collision strengths is studied. The accuracy of these calculations depends on: (1) the number of states used in the close coupling expansion; (2) resonance contributions to the thermally averaged collision strength; and (3) the quality of the target state wave functions. Tables of the derived oscillator strengths are presented.

Ho, Y. K.↗

Quasi-optical Josephson-junction oscillator arrays

Josephson junctions are natural voltage-controlled oscillators capable of generating submillimeter-wavelength radiation, but a single junction usually can produce only 100 nW of power and often has a broad spectral linewidth. The authors are investigating 2D quasi-optical power combining arrays of 103 and 104 NbN/MgO/NbN and Nb/Al-AlO(x)/Nb junctions to overcome these limitations. The junctions are dc-biased in parallel and are distributed along interdigitated lines. The arrays couple to a resonant mode of a Fabry-Perot cavity to achieve mutual phase-locking. The array configuration has a relatively low impedance, which should allow the capacitance of the junctions to be tuned out at the oscillation frequency.

Stern, J. A.↗

Aberration correction of unstable resonators

Construction of aspheric reflectors for unstable resonator lasers to provide an arbitrary laser mode inside the resonator to correct aberrations of an output beam by the construction of the shape of an end reflector opposite the output reflector of the resonator cavity, such as aberrations resulting from refraction of a beam exiting the solid of the resonator having an index of refraction greater than 1 or to produce an aberration in the output beam that will precisely compensate for the aberration of an optical train into which the resonator beam is coupled.

Lang, Robert J.↗

The Dissociative Recombination of OH(+)

Theoretical quantum chemical calculations of the cross sections and rates for the dissociative recombination of the upsilon = 0 level of the ground state of OH(+) show that recombination occurs primarily along the 2 (2)Pi diabatic route. The products are 0((1)D) and a hot H atom with 6.1 eV kinetic energy. The coupling to the resonances is very small and the indirect recombination mechanism plays only a minor role. The recommended value for the rate coefficient is (6.3 +/- 0.7) x 10(exp -9)x (T(e)/1300)(exp -0.48) cu.cm/s for 10 less than T(e) less than 1000 K.

Guberman, Steven L.↗

Design of a Dual Waveguide Normal Incidence Tube (DWNIT) Utilizing Energy and Modal Methods

This report investigates the partition design of the proposed Dual Waveguide Normal Incidence Tube (DWNIT). Some advantages provided by the DWNIT are (1) Assessment of coupling relationships between resonators in close proximity, (2) Evaluation of "smart liners", (3) Experimental validation for parallel element models, and (4) Investigation of effects of simulated angles of incidence of acoustic waves. Energy models of the two chambers were developed to determine the Sound Pressure Level (SPL) drop across the two chambers, through the use of an intensity transmission function for the chamber's partition. The models allowed the chamber's lengthwise end samples to vary. The initial partition design (2" high, 16" long, 0.25" thick) was predicted to provide at least 160 dB SPL drop across the partition with a compressive model, and at least 240 dB SPL drop with a bending model using a damping loss factor of 0.01. The end chamber sample transmissions coefficients were set to 0.1. Since these results predicted more SPL drop than required, a plate thickness optimization algorithm was developed. The results of the algorithm routine indicated that a plate with the same height and length, but with a thickness of 0.1" and 0.05 structural damping loss, would provide an adequate SPL isolation between the chambers.

Betts, Juan F.↗

Enhancement of Optical Nonlinearities Via Whispering Gallery Mode Splitting

An iterative method is applied to the analysis of N coupled ring-resonators, and the results are compared with multilayered spheres. Splitting of the whispering gallery modes into N higher-Q modes occurs when the round-trip phase shifts in each ring (or layer) are equal, in agreement with results for planar resonators. This mode-splitting is, therefore, a universal phenomenon for resonant structures, and can lead to reduced thresholds for nonlinear optical effects.

Chang, Hongrok↗

NASA Tech Briefs, March 2008

Topics covered include: WRATS Integrated Data Acquisition System; Breadboard Signal Processor for Arraying DSN Antennas; Digital Receiver Phase Meter; Split-Block Waveguide Polarization Twist for 220 to 325 GHz; Nano-Multiplication-Region Avalanche Photodiodes and Arrays; Tailored Asymmetry for Enhanced Coupling to WGM Resonators; Disabling CNT Electronic Devices by Use of Electron Beams; Conical Bearingless Motor/Generators; Integrated Force Method for Indeterminate Structures; Carbon-Nanotube-Based Electrodes for Biomedical Applications; Compact Directional Microwave Antenna for Localized Heating; Using Hyperspectral Imagery to Identify Turfgrass Stresses; Shaping Diffraction-Grating Grooves to Optimize Efficiency; Low-Light-Shift Cesium Fountain without Mechanical Shutters; Magnetic Compensation for Second-Order Doppler Shift in LITS; Nanostructures Exploit Hybrid-Polariton Resonances; Microfluidics, Chromatography, and Atomic-Force Microscopy; Model of Image Artifacts from Dust Particles; Pattern-Recognition System for Approaching a Known Target; Orchestrator Telemetry Processing Pipeline; Scheme for Quantum Computing Immune to Decoherence; Spin-Stabilized Microsatellites with Solar Concentrators; Phase Calibration of Antenna Arrays Aimed at Spacecraft; Ring Bus Architecture for a Solid-State Recorder; and Image Compression Algorithm Altered to Improve Stereo Ranging.

Source record↗

NASA Tech Briefs, December 2007

Topics include: Ka-Band TWT High-Efficiency Power Combiner for High-Rate Data Transmission; Reusable, Extensible High-Level Data-Distribution Concept; Processing Satellite Imagery To Detect Waste Tire Piles; Monitoring by Use of Clusters of Sensor-Data Vectors; Circuit and Method for Communication Over DC Power Line; Switched Band-Pass Filters for Adaptive Transceivers; Noncoherent DTTLs for Symbol Synchronization; High-Voltage Power Supply With Fast Rise and Fall Times; Waveguide Calibrator for Multi-Element Probe Calibration; Four-Way Ka-Band Power Combiner; Loss-of-Control-Inhibitor Systems for Aircraft; Improved Underwater Excitation-Emission Matrix Fluorometer; Metrology Camera System Using Two-Color Interferometry; Design and Fabrication of High-Efficiency CMOS/CCD Imagers; Foam Core Shielding for Spacecraft CHEM-Based Self-Deploying Planetary Storage Tanks Sequestration of Single-Walled Carbon Nanotubes in a Polymer PPC750 Performance Monitor Application-Program-Installer Builder Using Visual Odometry to Estimate Position and Attitude Design and Data Management System Simple, Script-Based Science Processing Archive Automated Rocket Propulsion Test Management Online Remote Sensing Interface Fusing Image Data for Calculating Position of an Object Implementation of a Point Algorithm for Real-Time Convex Optimization Handling Input and Output for COAMPS Modeling and Grid Generation of Iced Airfoils Automated Identification of Nucleotide Sequences Balloon Design Software Rocket Science 101 Interactive Educational Program Creep Forming of Carbon-Reinforced Ceramic-Matrix Composites Dog-Bone Horns for Piezoelectric Ultrasonic/Sonic Actuators Benchtop Detection of Proteins Recombinant Collagenlike Proteins Remote Sensing of Parasitic Nematodes in Plants Direct Coupling From WGM Resonator Disks to Photodetectors Using Digital Radiography To Image Liquid Nitrogen in Voids Multiple-Parameter, Low-False-Alarm Fire-Detection Systems Mosaic-Detector-Based Fluorescence Spectral Imager Plasmoid Thruster for High Specific-Impulse Propulsion Analysis Method for Quantifying Vehicle Design Goals Improved Tracking of Targets by Cameras on a Mars Rover Sample Caching Subsystem Multistage Passive Cooler for Spaceborne Instruments GVIPS Models and Software Stowable Energy-Absorbing Rocker-Bogie Suspensions

Source record↗