At least 199 records · Page 11

The Role of Demixing and Crystallization Kinetics on the Stability of Non‐Fullerene Organic Solar Cells

Abstract With power conversion efficiency now over 17%, a long operational lifetime is essential for the successful application of organic solar cells. However, most non‐fullerene acceptors can crystallize and destroy devices, yet the fundamental underlying thermodynamic and kinetic aspects of acceptor crystallization have received limited attention. Here, room‐temperature (RT) diffusion coefficients of 3.4 × 10 −23 and 2.0 × 10 −22 are measured for ITIC‐2Cl and ITIC‐2F, two state‐of‐the‐art non‐fullerene acceptors. The low coefficients are enough to provide for kinetic stabilization of the morphology against demixing at RT. Additionally profound differences in crystallization characteristics are discovered between ITIC‐2F and ITIC‐2Cl. The differences as observed by secondary‐ion mass spectrometry, differential scanning calorimetry (DSC), grazing‐incidence wide‐angle X‐ray scattering, and microscopy can be related directly to device degradation and are attributed to the significantly different nucleation and growth rates, with a difference in the growth rate of a factor of 12 at RT. ITIC‐4F and ITIC‐4Cl exhibit similar characteristics. The results reveal the importance of diffusion coefficients and melting enthalpies in controlling the growth rates, and that differences in halogenation can drastically change crystallization kinetics and device stability. It is furthermore delineated how low nucleation density and large growth rates can be inferred from DSC and microscopy experiments which could be used to guide molecular design for stability.

Hu, Huawei↗

Implementation and validation of optimal start control strategy for air conditioners and heat pumps

Commercial buildings are responsible for approximately 20 % of the total energy consumption and greenhouse gas emissions in the United States. Over 85 % of these buildings lack building automation systems, and many are small (<50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper energy management systems, several operational deficiencies lead to excess energy consumption. Studies have shown that managing the RTUs’ heating and cooling set points, schedules, setbacks, and optimal start can result in a 20 % to 25 % reduction in electricity consumption in small commercial buildings. These buildings typically use fixed schedules to start the RTUs 60 to 120 min before occupancy begins, which results in excess energy consumption. This paper presents research that demonstrates and evaluates the performance of four optimal start methods, which utilize data-based modeling as a key element in facilitating adaptive control in response to time-varying inputs while requiring minimal sensor inputs. The evaluation found energy savings in two commercial buildings equipped with RTUs by periodically alternating four different optimal start models during the cooling and heating season. The resulting energy savings are positive for all models and range from 2 to 5 kWh/day/unit. The units on the east side of the building showed higher savings, while interior units showed greater variability in savings due to the differences in capacities and room sizes. Savings were considerably greater during the heating season compared to the cooling season. The performance of all four models on Mondays was poor; models suggested a shorter optimal start time, which resulted in relatively larger errors. Finally, the future work will look at using a different model for the days after weekends and holidays.

42 ENGINEERING↗

Ultra-Low SWaP CO 2 Sensing for Demand Control Ventilation (Final Report)

In this project PARC and Energy ETC aimed to develop an ultra-low cost, size, weight, and power (SWaP) printed CO 2 sensor system for occupancy detection to enable Demand Control Ventilation (DCV) on a per-room basis. The CO 2 sensor technology is based on the temperature variation when CO 2 reversibly physisorbs to a highly conductive and high surface area sorbent surface, and is compatible with integration with PARC innovations in printed sensors and flexible electronics, for which PARC is a globally leading research center. The printed CO 2 sensor itself is designed to be compatible with PARC’s “peel-and-stick” platform of ultra-low power, low-cost, distributed sensors, and to facilitate real-time DCV based on overall indoor air quality (IAQ). Previously, PARC has developed flexible hybrid electronics (FHE) compatible materials to measure humidity, temperature, light, strain, and gases such as carbon monoxide, methane, ammonia, and hydrogen sulfide. Through this project, PARC developed FHE-compatible materials to measure CO 2 . Thus, with one <$15 FHE “peel-and-stick” based sensor node, a building management system (BMS) will be able to capture a complete picture of the indoor environment. This includes IAQ, light, temperature, and other comfort factors that impact building operations. Combined with optimized DCV, this low-cost sensor capability can be a key enabler of annual primary energy savings of ~ 0.3-0.4 Quad in commercial buildings while ensuring healthy IAQ. Energy ETC is a leader in supplier-agnostic BMS deployments and will design the commissioning and deployment procedures to maximize system interoperability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Recharge Demand Mitigation for Latent Heat Thermal Energy Storage at Off-peak Hours

The utilization of integrated heat pump thermal energy storage (HP-TES) systems for space conditioning applications can reduce electrical power demand and achieve utility savings resulting from peak shaving and load shifting. However, issues arise when the energy required to recharge the TES exceeds the shifted energy demand, especially in extreme climates where high-temperature lifts between the outdoor air conditions and phase-change materials (PCMs) during recharging may occur. In this work, a single room-temperature (22°C) PCM-TES is integrated into a single-speed heat pump system using a secondary hydronic loop where the TES is recharged using the outdoor unit during off-peak hours. Three recharge strategies were investigated as potential pathways to reduce recharging power demand: (i) considering different heat source/sink temperatures, (ii) using a variable-speed compressor, and (iii) using a variable-speed pump. Simulations were conducted using Modelica for HP-TES recharging at different heat source/sink temperatures from -30 – 20℃ in heating mode and 0 – 30℃ in cooling mode. Results show that the most effective recharge demand reduction strategy is an HP-TES system using a single-speed compressor with a variable-speed pump for the hydronic loop run at preferable heat source/sink temperatures when the temperature lifts were reduced. Utilizing a variable-speed compressor for the HP-TES system reduced recharge time in extreme cases at the cost of additional compressor power input. The findings motivate potential control strategies that minimize recharge energy and maximize peak energy savings, hence reducing overall operating costs and annual energy consumption for HP-TES systems for space conditioning applications.

25 ENERGY STORAGE↗

Thermal Hydraulic Experimental Test Article (FY21 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time. Following installation of THETA into vessel #4, all data acquisition and control systems were brought online and commissioned at room temperature in the argon gas space of the empty vessel. The vessel zone 1 heaters were reinstalled and the flange was then insulated. The vessel 4 heaters were brought to a temperature of 100 °C and the THETA pump was jogged at 600 RPM to ensure it was functioning correctly. The secondary, AC Conduction based electromagnetic pump from CMI Novacast (product number CA-15) was ordered and will be delivered in late calendar year 2021. The custom designed permanent magnet based secondary flowmeter was designed, a drawing package and manufacturing specification created and quote requested from a machine shop. The intermediate heat exchanger design was completed and a drawing package is currently in progress. During the middle of calendar year 2021 the Building 308 sodium scrubber system was shut down in order to replaced some corroded piping and facilitate improvements on the system, thus requiring the sodium in METL to remain frozen. This has imposed a delay in filling vessel 4 with sodium to begin THETA testing. Sodium testing is expected to begin in early fiscal year 2022 as all THETA primary systems are operational.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Atomic Layer Deposition for Materials-Based H2 Storage: Opportunities and Limitations

The transportation demands in our growing hydrogen (H2) economy requires robust storage systems. The current commercially implemented technology in fuel cell cars relies on the well-established technology of hydrogen gas compressed to 350-700 bar, depending on the application. The compressed gas tanks in use today are bulky and cost intensive. To address this challenge, material-based storage is one of the long-term alternatives considered and constitutes the focus of this talk. Material-based storage is broadly defined as hydrogen bound to solid materials, with its binding strength varying from physisorption to porous materials, such as zeolites and metal organic frameworks, to chemisorption in (complex) metal hydrides. The ultimate targets set by the U.S. Department of Energy for this technology include a system gravimetric capacity of 6.5 wt% and volumetric capacity of 40 g/L at 100 bar, operating temperatures ranging between -40 C and +40 C and adsorption/desorption timescales of < 5 min. Storage in the form of physisorbed or chemisorbed hydrogen has guided the materials research, which metal- organic framework and (complex) metal hydrides being the most promising materials classes. A variety of these materials have met one or more of the targets, but it has remained elusive for a single material system to meet all these stringent requirements. Nano-encapsulation and low-concentration chemical additives have previously been employed separately to overcome such challenges. Functionalization via atomic layer deposition (ALD), however, offers unique characteristics that make it suitable for both, nano-encapsulation and "doping" with low-concentration additives. This deposition technique has sub-monolayer thickness control, is highly conformal in high-surface area materials and is self-limiting, i.e., once the gas-phase precursor reacts with the available surface sites, the surface reactions stop. In this presentation, we will showcase examples where ALD, more generally vapor-phase functionalization, on (complex) metal hydrides and organic frameworks has improved the material properties for H2 storage. In our first study, Al2O3 was deposited on magnesium borohydride, Mg(BH4)2, at room temperature using trimethylaluminum (TMA) and water. From our findings, encouraging initial results were obtained: the H2 desorption temperature was lowered by 60-120 degrees C, the desorbed gravimetric H2 capacity at temperatures < 250 degrees C was doubled, and the desorption kinetics increased by a factor of ~6 compared to uncoated Mg(BH4)2. However, hydrolysis reactions caused by residual surface -OH groups from the ALD water-pulse degraded the sample substantially. Through this study, the use of TMA was observed to be highly reactive with the Mg(BH4)2 surface species, leading to the strategy of exposing the sample only to TMA. The relative mole fraction of the vapor-phase additive can be precisely controlled with the number of TMA pulses and pulse duration. By tuning these parameters, we show in our second study that 10 pulses of TMA at ambient conditions were able to decrease the H2 desorption temperature by ~100 degrees C while retaining <95 % of its H2 capacity. We applied this approach with other additives such as BBr3, TiCl4 and tetrahydrofuran, and demonstrate that this unique approach opens the door to a new class of molecular additives and catalysts which cannot easily be introduced with conventional mechano-chemical or solvent-based techniques for (complex) metal-hydrides. In the case of metal organic frameworks, ALD is a promising technique to functionalize the pores with metal atoms or functional groups able to tune the gas selectivity and binding energy, for which ~15 kJ/mol has been established as the optimal value for H2 storage in sorbent materials. Vapor-phase techniques such as ALD have numerous benefits over other functionalization tools for H2 storage materials opening innumerable opportunities to the field. To exploit these opportunities, the current limitations on room temperature and water-less ALD processes needs to be overcome which will greatly expand the possibilities of encapsulation and incorporation of additives for organic frameworks and (complex) metal hydrides.

atomic layer deposition↗

Advanced Human-System Interface Risk Analysis Based on Redundancy-guided Systems-theoretic Hazard Analysis and Human Reliability Analysis

Human-system interfaces (HSIs) play an important role in enabling operators to communicate with the nuclear power plant (NPP) side. Getting the information required to understand a NPP’s current status or perform necessary actions for responding to a given operational context are representative operator tasks performed using HSIs. To date, HSIs have been mainly evaluated in the context of human reliability analysis (HRA). However, the current HSI evaluation that occurs during HRA may be challengeable on two fronts: (1) reflecting the unique characteristics of HSI systems and (2) considering situations in which HSIs are poorly operated due to software/hardware malfunctions. Accordingly, this study proposes an approach for specifically evaluating HSIs for digital instrumentation and controls (DI&C) systems, using Redundancy-guided Systems-theoretic Hazard Analysis (RESHA) and HRA. RESHA is a method for analyzing DI&C systems with redundancy features. In this study, we investigate how HSIs are evaluated in existing HRA methods, and what challenges exist in the current approaches. To better evaluate HSIs for DI&C systems, this study modifies the existing HSI evaluation process by additionally modeling the HSI back- and front- ends. In this paper, a HSI fault tree for the APR1400 DI&C system is introduced through a piping and instrumentation diagram. It then touches upon what aspects of the suggested method must be further researched.

99 GENERAL AND MISCELLANEOUS↗

Overview of Quantum Sensing Materials and Techniques for Energy Sector Applications

The energy sector has become increasingly dependent upon highly sensitive sensing devices for a wide range of applications. Variables such as temperature, pH, electromagnetic fields, ions, and pressure must be measured with high precision, often in harsh conditions (e.g. highly corrosive environments due to high temperature, pressure and humidity). These sensors are deployed in infrastructure such as transformers, pipelines, mines, nuclear power plants, and other areas to ensure safe operating conditions and uninterrupted, optimized service. Moreover, new opportunities for sensors have emerged due to the expansion of smart grids/meters, driverless vehicles, and the discovery of new oil, gas, and critical mineral deposits. The continued maturation of quantum sensing technologies offers exciting opportunities for quantum-enhanced measurements within the energy sector that may provide significant improvements in sensitivity beyond the classical limit. Here, an overview of established and emerging quantum materials for sensing applications will be provided, from trapped ions to color centers in diamond and silicon carbide. Associated quantum sensing methods for these materials will be discussed, with an emphasis on platforms that are nearing commercial viability. Specific application opportunities within the energy sector for quantum sensors will then be analyzed, including oil/gas discovery, greenhouse gas emission monitoring, pH and ion sensing, current measurement in electric vehicle batteries, and quantum-enhanced spectroscopy. Remaining barriers, such as quantum sensor platform miniaturization and ruggedization, will also be analyzed. A specific project at the National Energy Technology Laboratory involving the functionalization of qubits using metal-organic frameworks for enhanced quantum sensing will also be highlighted. Here, nitrogen vacancy centers (NV) in nanodiamonds, a commercially available qubit with long coherence times and utilizable quantum properties at room temperature, are encapsulated in a controlled way using the metal-organic framework ZIF-8. The ZIF-8 provides a well-defined, porous scaffold that can be controlled to promote the selective uptake of specific target analytes, such as gas molecules or ions. The quantum sensing performance of this composite material is either preserved or enhanced following ZIF-8 encapsulation; the optically detected magnetic resonance response of the NV nanodiamonds with and without the ZIF-8 coating are identical, while the ZIF-8 coating increases the longitudinal spin relaxation lifetime (T1) of the NV centers, an important parameter for spin relaxometry-based quantum sensing experiments. Taken together, these results demonstrate the importance of qubit functionalization as a crucial step for rationally designing high performance quantum sensors.

Crawford, Scott↗

Tracer gas test in Net-Zero Energy Residential Test Facility

The Net-Zero Energy Residential Test Facility (NZERTF) at NIST was built in 2012 to support the development and adoption of cost-effective net-zero energy designs, technologies, and construction methods. It is two-story, and has four bedrooms, three bathrooms, and an open living room, dining room, and kitchen space. The NZERTF also has a basement and attic, both located within the conditioned space because the thermal and air-moisture barriers encompass the basement walls and attic roof. Transfer grilles link the living spaces to these two zones. The central heating and cooling system includes an air-toair heat pump, which delivers air to the basement, first and second floors. The heat pump has a cooling capacity of 7.6 kW and a heating capacity of 7.8 kW. The indoor unit is in the basement and ductwork runs along the basement ceiling. A balanced heat recovery ventilator (HRV) is installed in the basement and has its own dedicated ductwork. The HRV supplies 47 L/s of outdoor air to the house, with supplies on the first floor (in the kitchen/dining area) and in each of the three second-floor bedrooms. Air from the first-floor bathroom and both second-floor bathrooms is returned to the HRV before being exhausted, though the HRV was turned off during the tests. The house also has a range hood exhaust and a clothes dryer exhaust, both of which were turned off for the tests. The temperature of the house was measured and the operation of the space conditioning system, including its recirculating air distribution fan, were controlled by a commercially available thermostat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation and Experimental Validation of an Integrated Heat Pump – Thermal Energy Storage Using a Room-Temperature Phase Change Material

As the dependence on electrical heat pumps (HPs) and intermittent renewables increases, grid strains are expected to grow. This necessitates an energy storage system to reduce the mismatch between energy supply and demand. Thus, a proposed dual-mode commercially available 14.1 kW HP was integrated with a single 22°C phase change material (PCM) thermal storage system (TES) to load-shift both cooling and heating loads. The HP-TES system was manufactured and experimentally tested using a novel test matrix based on AHRI 210/240 psychrometric conditions. Furthermore, transient dual-mode system-level HP-TES models were developed in Modelica and validated using the experimental test conditions. Base HP cooling and heating experimental tests at ambient temperatures of 35°C and −8.3°C show that the modified HP-TES maintained the rated system capacity and performance. The HP-TES discharge provided approximately 30% and 50% reductions in cooling and heating demand, respectively. The transient HP-TES models predicted system capacity and total power input for discharge and recharge operating modes within ±4% mean percentage error, and recharge power input within ±2%, with maximum errors occurring at the equipment startup. During system operation, the sources of model deviations are first-order polynomial fits of the PCM digital scanning calorimetry (DSC) data and unaccounted supercooling in the PCM during solidification. Nonetheless, the model predictions agree with the experimental tests, demonstrating the availability of robust, accurate, and validated transient models that can be used for further validation and the development of system controls.

25 ENERGY STORAGE↗

HSQC spectra of lignin isolated from poplar roots

Here we present a curated dataset of two-dimensional heteronuclear single quantum coherence (HSQC) nuclear magnetic resonance (NMR) spectra of lignin isolated from roots of a greenhouse grown natural population of an energy crop poplar (Populus trichocarpa). Dormant cuttings of field-grown poplar were grown in 6-liter pots in a peat-based media containing bark, perlite, vermiculite, dolomite lime and a wetting agent in an environmentally controlled greenhouse. Temperatures were between 21 and 23 °C, with supplemental lighting to support a 16-h day length using 1000-watt high-pressure sodium lights in greenhouse. Once established, all plants were cut-back, allowed to regrow and harvested at the same time following an eight-month long growth period. Plants were harvested and the belowground roots were washed off soils, blotted, dried in an oven at 70 °C for 3 days, and Wiley milled (mesh size 20). The roots were Soxhlet-extracted with toluene/ethanol for 24 h to remove extractives. The extracted roots were ball-milled in a Retsch PM100 planetary ball mill using a porcelain jar with ceramic balls at 600 rpm for 2 h (in 5 min on and 5 min off cycles to avoid excessive sample heating). The ball-milled materials were then subjected to enzymatic hydrolysis for 48 h followed by centrifugation and washing with deionized water. The solid residue was extracted twice with 96% (v/v) 1,4-dioxane/water mixture at room temperature overnight. The extracts were combined, rotary evaporated, and freeze-dried to recover lignin. The dry lignin samples were dissolved in deuterated dimethyl sulfoxide (d6) and transferred into a 5 mm tube. 13C–1H HSQC experiments were performed in a Bruker Avance III HD 500 MHz NMR spectrometer operating at a frequency of 125.12 MHz for the 13C nucleus using a standard Bruker pulse sequence on a Prodigy platform cryoprobe. The NMR spectra were acquired under the following acquisition conditions: 220 ppm spectral width in F1 (13C) dimension with 256 data points and 12 ppm spectral width in F2 (1H) dimension with 1024 data points, a 90° pulse, a one bond C–H coupling constant of 145 Hz, a 1.0 s pulse delay, and 64 scans. Spectra were processed using the Bruker TopSpin software. Additional meta data is embedded in the raw spectra figures.

HSQC, lignin, poplar, roots, CBI↗

Mechanical characterization of fine-grain dispersion-strengthened tungsten as a plasma facing material

Field-Assisted Sintering Technology (FAST) was used to produce fine-grained, dispersion-strengthened tungsten (W) materials. Investigated materials 4138, 4353, and 4355 composed of 3 wt% ZrC sintered at 1800 °C, 5 wt% ZrC sintered at 1800 °C, and 3 wt% ZrC sintered at 2000 °C, respectively. They were compared against ITER-grade W. A series of mechanical and thermal property testing and microstructure studies were conducted to study them as a potential plasma facing material (PFM) for fusion reactors. Hardness testing showed that manufacturing conditions substantially altered hardness. Material 4355 had an average HV10 value of 497.2 ± 16.8, slightly higher than ITER-grade at 378.5 ± 40.3. However, material 4353 was substantially higher with an HV10 value of 738.9 ± 31.7 over the investigated temperature range. Electron Backscatter Diffraction (EBSD) analysis showed that FAST produced substantially smaller grains than the hot-rolled ITER-grade W material, offering notable control over grain size. Materials 4353 and 4355 had grain sizes of 0.44 ± 0.20 µm and 3.67 ± 0.89 µm, respectively, whereas ITER-grade 27.14 ± 19.76 µm at room temperature. The fine grain structures showed no net coarsening after 1 hr. anneals up to 1800 °C, several hundred degrees above the 1100 – 1500 °C recrystallization range reported for conventional W. Inverse application of the Zener pinning relationship to the measured grain sizes indicates that these two FAST sintering conditions produce markedly different effective dispersoid populations, with effective particle diameters of approximately 90 nm at a peak sintering temperature of 1800 °C and approximately 460 nm at 2000 °C, respectively. This result demonstrates that the FAST thermal condition itself, and not the nominal ZrC content alone, governs the pinning effectiveness of the dispersion. Thermal diffusivity measurements support this finding independently. Materials of identical composition sintered at different temperatures differ by approximately 19% in measured thermal diffusivity with statistically indistinguishable density, while materials of different composition and sintering temperature converge to within approximately 2%. At a representative divertor heat flux of 10 MW/m², the lower thermal conductivity of the fine-grained materials corresponds to approximately 28 to 33 °C per millimeter of armor thickness relative to ITER-grade W, traded against a substantially larger margin to recrystallization-driven degradation. While high temperature tensile testing revealed likely contamination that motivates refinement of the manufacturing process, FAST-produced, fine-grained, dispersion-strengthened W offers process-controlled microstructural stability well above the operating temperatures of conventional W and supports its continued development as a PFM for economically viable commercial fusion power.

Parker, Gabe [ORNL] (ORCID:0000000190394100)↗

Defending the Homeland: Growing Foreign Challenges to the U.S. Missile Defense Posture

The Office of the Secretary of Defense (OSD) for Policy requested that Lawrence Livermore National Laboratory conduct a Congressionally directed study on homeland missile defense, pursuant to Section 1692 of the fiscal year 2020 National Defense Authorization Act. In accordance with the statutory language, this study considers whether the security benefits obtained by deployment of homeland missile defenses of the United States are undermined or counterbalanced by adverse reactions of potential adversaries, and considers the effectiveness of homeland missile defense efforts of the United States to deter the development of ballistic missiles. Almost a half-century has elapsed since the United States and the Soviet Union signed the Anti-Ballistic Missile (ABM) Treaty, and almost two decades since the former withdrew. Since withdrawing, the United States has sought to develop and deploy a layered missile defense system to defend against regional threats to U.S. and allied interests abroad and to counter limited threats to the U.S. homeland. As such, missile defense supports key national defense policy objectives. Protecting the U.S. homeland, forces abroad, allies, and partners. Deterring attacks against the United States, its allies, and partners. Assuring allies an strengthening U.S. diplomatic activities in peacetime and crisis. We offer five key findings: 1. The primary benefit of the Ground-based Midcourse Defense (GMD) system is the protection it provides the U.S. homeland against a limited but evolving rogue-state missile threat. While this system has never been tested in combat, it appears thus far to have effectively paced North Korea’s development and deployment of intercontinental ballistic missiles (ICBMs). In the absence of such a defensive capability, the United States would likely have been more heavily exposed to North Korean actions, would have operated at a much higher-risk posture, and would have had less negotiating room with which to navigate coercive tactics and crises. Its allies would have been more concerned about U.S. willingness in time of crisis and war to run the risks of protecting them. The GMD system also serves as a hedge against Iranian breakout. 2. Potential adversaries continue to develop long-range ballistic missiles despite deployment of a U.S. homeland missile defense system. This includes both rogue states and major power rivals whose long-range missile programs predated the deployment of U.S. missile defenses. While North Korea has continued its long-range missile developments and achieved an intercontinental capability, Iran has not yet reached this threshold. The broader proliferation of long-range missiles anticipated in the late 1990s has not materialized. 3. While Russia has used the existence of a U.S. homeland missile defense system as a justification for its substantial and continuing weapon modernization program, neither Russian force modernization nor the limited U.S. homeland missile defense system has altered the strategic balance. Russia has long considered U.S. missile defenses—both theater and homeland—as directed against its strategic forces and as a capability that could rapidly advance, thereby eroding Russian confidence in its nuclear deterrent. Russia’s political and military actions appear excessive and negatively impact areas such as arms control, but they do not undermine the primary benefit of the U.S. system cited in Key Finding 1. 4. China’s expansion and diversification of nuclear and missile forces has been influenced by its concerns about U.S. homeland missile defense, but those concerns are only one of many factors in China’s force planning. Although China’s actions to preserve and expand its assured retaliation prospects have not fundamentally altered the strategic balance, its buildup and lack of transparency about its force modernization goals are troubling. Taken together, the aggregate pattern of China’s modernization activities over the past two decades strongly suggests a concerted effort to develop a modern military force commensurate with its intended geopolitical status. Whatever China’s legacy concerns over the survivability of its strategic nuclear forces, its ability to overwhelm the GMD system appears intact today and will be further strengthened in the years ahead as it continues its long-term modernization program. China’s political and military actions negatively affect U.S. security interests but do not undermine the primary benefit of the U.S. system cited in Key Finding 1. 5. The basic finding that benefits have not so far been undermined by adverse reactions is a function of circumstances that are increasingly in flux. The existing GMD-centered system is under increasing pressure from the pace and scope of North Korean missile deployments. The proposed “layered” system seeks to mitigate this impending capability gap in the near term and to complement future capabilities, such as the Next Generation Interceptor, when they come online. Given the pace of U.S. missile defense developments since 2000, it is possible that adversary advances in capability will outpace the U.S. system’s ability to adapt. Additionally, because this layered system is in principle more readily scaled, it will almost certainly be viewed skeptically by China and Russia. In a context of growing great-power security competition, the Department of Defense (DoD) should consider undertaking a broader net assessment of the U.S., Russian, and Chinese force balance.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Multi-channel front-end ASIC for a 3D position-sensitive detector

Arrays of 3D position-sensitive detectors (3DPSD), operating at room temperature and using cadmium zinc telluride (CZT) and thallium bromide (TIBr) sensors, are suitable for gamma-ray spectrometry in many applications. One detector configuration, the 3D position-sensitive Virtual Frisch-Grid detector (VFG), is particularly advantageous for integrating into large area arrays. The signals generated inside each detector of the array are captured with the anode, cathode and four pads that enable the reconstruction of the position and energy of the ionizing interaction by measurements of amplitude and timing of the signals. For these applications, a low-noise front-end ASIC has been developed, capable of processing bipolar signals (needed because of AC-coupling of certain electrodes). The ASIC can be coupled to an ADC in order to form a compound “waveform digitizer” capable of post-processing the analog signals and determining amplitude and timing information. This paper describes a 32-channel front-end ASIC that is suitable for reading out a 3 × 3 or 4 × 4 element matrix in the VFG configuration. Each channel is composed of a low-noise charge amplifier with an adaptive continuous reset feedback circuit suitable for both positive and negative charge, a first order shaper and a single-to-differential converter output stage. Voltage and current references are all internally generated by 10-bit DACs and the chip is fully controllable with the I 2 C communication protocol. The readout channel response has been verified using the implemented injection circuit. Linear behavior up to ~75 ke ± with the gain of ~80 mV/fC, and up to ~200 ke ± with the gain of ~30 mV/fC was demonstrated. In conclusion, the first test result waveforms using a 137 Cs radioactive source on a 5 × 5 × 12 mm 3 TIBr crystal are reported.

47 OTHER INSTRUMENTATION↗

Heteroatom-Modified and Compacted Zeolite-Templated Carbons for Gas Storage

Methane, the primary component of natural gas, is an energy-rich fuel by weight but exhibits lower energy density by volume than diesel and gasoline; efforts to increase its “volumetric” energy density have been focused on the design and synthesis of a porous scaffold that can bind the methane favorably. Novel approaches typically invoke the highly designable class of materials known as metal-organic frameworks (MOFs) owing to the relative difficulty of controlling carbon structure and composition precisely, without the use of a metal-based node. In this project, we instead explore the concept of carbon templating to achieve a porous scaffold with atomistically thin walls separated at a distance of ~1.2 nm, ideal for the formation of precisely two layers of methane per pore. This bottom-up templating approach permits the use of any small molecular precursor to build up the carbon scaffold, begging the question: which other elements (besides carbon) can be used to tune the surface for optimal methane binding without compromising the structure of the overall material? Boron and nitrogen were both explored and nitrogen was identified as the ideal agent for increasing methane binding to the optimal strength for use at near room temperature. Densification of the resulting materials by mechanical compaction was then explored to produce free-standing pellets with the highest methane “delivery” capacities of any known material. Here we define the amount “delivered” as the amount stored minus the amount remaining in the tank at 73 psi, the lowest useful pressure for vehicular transportation applications. The key features of the resulting methane storage system are rapid discharging and refueling speeds, extremely long cycle life (infinite cycle life for high-purity methane), a near-constant heat of refueling (making the heat generated upon refueling easier to manage), and a low maximum pressure of operation (<1500 psi), enabling the use of all-metal Type I cylinders and significantly reducing the costs of conversion of existing vehicles to cleaner burning, abundantly available natural gas). The technical effectiveness of this approach was further improved by exploring several cost-reduction strategies and investigating the reliability of such storage systems in the presence of “real” natural gas mixtures which contain a mixture of gaseous species.

03 NATURAL GAS↗

Indoor Occupant Counting by RF Backscattering

Building HVAC (heating, ventilation and air conditioning) consumes approximately 13% of all energy consumption in USA. Motion detectors, cameras and user programmable thermostats have been shown to be ineffective for HVAC controls to save energy, mostly due to the user concerns of comfort, reliability and privacy. A new HVAC control system based on real-time occupant counting that is fully automated, highly accurate, economically sensible and preserving privacy and aesthetics can thus bring forth a disruptive impact to this large energy sector. Our indoor occupant monitoring technology is based on the radio-frequency identification system (RFID), deployed in the room, not on the occupants. One reader with four antennas can be deployed on the ceiling or behind the ceiling panels for every thousand square feet in home, office and assisted living, with or without room partitions. The sticker-like passive tag, 10 cents each and maintenance-free, are profusely hidden on the wall or inside the furniture at arbitrary position, preserving privacy and aesthetics. The large number of tags can realize diverse observation points to accommodate arbitrary room layouts, which is impractical by other active units of camera, infrared, radar or lidar. With 20 tags, the system can reliably detect the number of occupants. For 100 tags, occupant posture and location can be known. The technology has been verified in the research labs and test buildings with very high accuracy. When the real-time occupant number can be accurately known without assuming devices on occupants or occupant motion, the building HVAC system can be automated to achieve building energy saving without sacrificing occupant comfort. According to our limited testing in a few types of building models and the simplified cost calculation, the RFID system has low overall cost in production, deployment, operation and maintenance. The signal processing algorithm based on machine learning requires very small number of training cases as most learning is transferrable for various layouts, and very low computational needs during operation, according to our testing in four different room sizes and layouts. In our preliminary estimate from HVAC saving alone, the RFID system can potentially pay for itself within 1.5 years, in addition to the other enhancement in building automation systems (BAS). Our commercialization strategy and business pitch deck focus on venturing this Cornell occupant monitoring technology into BAS and energy management markets. We have identified three broad BAS market segments of senior living, residential buildings, and office buildings. We have put together the minimum viable product characteristics for these identified segments, including analyses on total cost and competing technologies, as well as the fit and technical gaps for these market segments. We intend to bring the technology to market by licensing or partnering with existing BAS vendors. A list of potential collaborators and licensing partner candidates was assembled for different aspects of integrating our technology into a potential product that can be used with BAS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tank 48H Tetraphenylborate Mitigation: Simulant Studies using Sodium Permanganate

Tank 48H currently holds legacy material containing organic tetraphenylborate (TPB) compounds from the operation of the In-Tank Precipitation (ITP) process. TPB was added during the ITP process to precipitate the otherwise soluble cesium as insoluble cesium TPB (CsTPB), but excessive benzene generation from TPB degradation curtailed this treatment method. The contents of Tank 48H, which include approximately 26.000 kg of potassium TPB (KTPB) and trace CsTPB, are not compatible with the waste treatment facilities at the Savannah River Site (SRS) since the organic content and the associated flammability issues pose a challenge to the salt processing and sludge processing facilities within the liquid waste system. An in-tank process to remove (or decompose) TPB safely would be of great value. Previous testing at Savannah River National Laboratory (SRNL) demonstrated the destruction of glycolate via chemical oxidation using sodium permanganate with simulated and radioactive waste. Scoping tests were performed to study the destruction of TPB to determine if the contents of Tank 48H would be amenable to the same type of destruction. Partial destruction of TPB was observed in Tank 48H simulants under mild conditions (e g., pH 11, room temperature) with no definitive indication of benzene generation. To build upon the success of the scoping tests, an additional study was requested to provide a better understanding of the underlying chemistry for Tank 48H content destruction using sodium permanganate. Three experiments were performed with Tank 48H simulants at 40 °C to determine the efficacy of using sodium permanganate for TPB destruction. Three starting pH values were selected: 1) pH 11 for comparison with the previous work at room temperature, 2) pH 10 as the minimum pH recommended by the Corrosion Control Program (CCP) for in-tank processing, and 3) pH 8 to determine the effectiveness of TPB destruction at near neutral pH. While below the allowable pH for the CCP, the experiment at pH 8 was performed to study the TPB-Permanganate reaction under more extreme conditions and further verify the potential for out-of-tank processing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a Particle Flow Control Mechanism

The next generation of Concentrated Solar Power (CSP) systems are utilizing solid particles as the heat transfer medium. The state-of-the-art particle flow control mechanism currently utilized is the slide-gate mechanism which functions by linearly actuating a gate across a tear-drop shaped opening. The sensitivity, which is a measure of the change in mass flow rate per unit movement of the slide-gate, is 0.354 g/s-mm[1]. The slide-gate’s main shortcomings include particle lodging and particle leakage between the plates, and difficulty actuating under the pressure from the particles. The goal of a new device is to minimize or eliminate these flaws. The new proposed device functions similar to a chuck mechanism in a drill where a rotation of an outer ring produces a change in outlet area through moving “jaws” diagonally. This mechanism aims to solve the issues of the slide-gate by having the jaws on the outside of the particle flow volume to reduce the probability of particle lodging, and the jaw tips are designed to overlap as they actuate to reduce particle leakage. Additionally, the vertical orientation of the device as well as the inclined movement of the jaws allows for easier actuation of the device under pressure. Experiments involving 3D printed prototypes have been carried out, producing a max mass flowrate of about 50 g/s and a sensitivity curve with the equation 𝑦 (𝑔/𝑠) = 0.0851𝑥^2(𝑔/𝑠−𝑚𝑚2) +3.6993𝑥(𝑔/𝑠−𝑚𝑚). These experiments validated the device’s capability to address the shortcomings of the slide-gate. Currently, an aluminum model of the device is being tested at room temperature, and a stainless-steel model is being developed to be tested at 700oC, which is the expected operating temperature of the CSP system. Furthermore, simulations are on-going to predict the mass flowrate of different device configurations at room and high temperatures.