Research and development of magnesium/aluminum electroforming process for solar concentrators Final report, 13 May 1966 - 10 May 1967
Magnesium and aluminum electroforming process for solar concentrators
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Magnesium and aluminum electroforming process for solar concentrators
Parametric analysis of surface temperatures and distortions of paraboloidal solar concentrators
Report summarizes test results from evaluation of concentrating solar collector thermal performance, from transient behavior, and incident-of-angle behavior. Tests were conducted using National Bureau of Standards recommedations and specifications.
Final report of program to improve commercially available concentrating solar collector describes final hardware, discusses problems encountered, and presents certification statements, photographs, and recommendations for modification.
Dynamic testing of an inflatable solar concentrator structure in a thermal vacuum chamber as well as in ambient laboratory conditions is described in detail. Unique aspects of modal testing for the extremely lightweight inflatable are identified, including the use of a noncontacting laser vibrometer measurement system. For the thermal vacuum environment, mode shapes and frequency response functions are compared for three different test article inflation pressures at room temperature. Modes that persist through all the inflation pressure regimes are identified, as well as modes that are unique for each pressure. In atmospheric pressure and room temperature conditions, dynamic measurements were obtained for the expected operational inflation pressure of 0.5 psig. Experimental mode shapes and frequency response functions for ambient conditions are described and compared to the 0.5 psig results from the thermal vacuum tests. Only a few mode shapes were identified that occurred in both vacuum and atmospheric environments. This somewhat surprising result is discussed in detail, and attributed at least partly to 1.) large differences in modal damping, and 2.) significant differences in the mass of air contained by the structure, in the two environments. Results of this investigation point out the necessity of testing inflatable space structures in vacuum conditions before they can be launched. Ground testing in atmospheric pressure is not sufficient for predicting on-orbit dynamics of non-rigidized inflatable systems.
Free-standing, transparent, tunable bandgap AlxGa1-xAs top solar cells have been fabricated for mechanical attachment in a four terminal tandem stack solar cell. Evaluation of the device results has demonstrated 1.80 eV top solar cells with efficiencies of 18 percent (100 X, and AM0) which would yield stack efficiencies of 31 percent (100 X, AM0) with a silicon bottom cell. When fully developed, the AlxGa1-xAs/Si mechanically-stacked two-junction solar cell concentrator system can provide efficiencies of 36 percent (AM0, 100 X). AlxGa1-xAs top solar cells with bandgaps from 1.66 eV to 2.08 eV have been fabricated. Liquid phase epitaxy (LPE) growth techniques have been used and LPE has been found to yield superior AlxGa1-xAs material when compared to molecular beam epitaxy and metal-organic chemical vapor deposition. It is projected that stack assembly technology will be readily applicable to any mechanically stacked multijunction (MSMJ) system. Development of a wide bandgap top solar cell is the only feasible method for obtaining stack efficiencies greater than 40 percent at AM0. System efficiencies of greater than 40 percent can be realized when the AlGaAs top solar cell is used in a three solar cell mechanical stack.
This paper describes the design, development, fabrication, and test of a high performance, high voltage solar concentrator array. This assembly is believed to be the first ever terrestrial triple-junction-cell solar array rated at over 1 kW. The concentrator provides over 200 W/square meter power output at a nominal 600 Vdc while operating under terrestrial sunlight. Space-quality materials and fabrication techniques were used for the array, and the 3005 meter elevation installation below the Tropic of Cancer allowed testing as close as possible to space deployment without an actual launch. The array includes two concentrator modules, each with a 3 square meter aperture area. Each concentrator module uses a linear Fresnel lens to focus sunlight onto a photovoltaic receiver that uses 240 series-connected triple-junction solar cells. Operation of the two receivers in series can provide 1200 Vdc which would be adequate for the 'direct drive' of some ion engines or microwave transmitters in space. Lens aperture width is 84 cm and the cell active width is 3.2 cm, corresponding to a geometric concentration ratio of 26X. The evaluation includes the concentrator modules, the solar cells, and the materials and techniques used to attach the solar cells to the receiver heat sink. For terrestrial applications, a finned aluminum extrusion was used for the heat sink for the solar cells, maintaining a low cell temperature so that solar cell efficiency remains high.
Proton and alpha particle effects on thermal properties of spacecraft and solar concentrator coating of anodic-coated aluminum, zinc oxide/ potassium silicate, etc
Proton and alpha particle effects on thermal properties of spacecraft and solar concentrator coatings of anodic-coated aluminum, zinc oxide/ potassium silicate, etc
A novel high-temperature particle solar receiver is developed using a light trapping planar cavity configuration. As particles fall through the cavity, the concentrated solar radiation warms the boundaries of the receiver and in turn heats the particles. Particles flow through the system, forming a fluidized bed at the lower section, leaving the system from the bottom at a constant flowrate. Air is introduced to the system as the fluidizing medium to improve particle heat transfer and mixing. A laboratory scale cavity receiver is built by collaborators at the Colorado School of Mines and their data are used for model validation. In this experimental setup, near IR quartz lamp is used to provide flux to the vertical wall of the heat exchanger. The system is modeled using the discrete element method and a continuum two-fluid method. The computational model matches the experimental system size and the particle size distribution is assumed monodisperse. A new continuum conduction model that accounts for the effects of solid concentration is implemented, and the heat flux boundary condition matches the experimental setup. Radiative heat transfer is estimated using a widely used correlation during the post-processing step to determine an overall heat transfer coefficient. The model is validated against testing data and achieves less than 30% discrepancy and a heat transfer coefficient greater than 1000 W/m2 K.
The integration of thermal energy storage into a concentrating solar power system allows for mitigating some of the risk associated with uncertain solar irradiance and uncertain energy prices. We solve a 48 h dispatch optimization model with continually updated conditional point forecasts of both direct normal irradiance (DNI) and electricity prices with a rolling-horizon scheme at hourly resolution over the course of a year. Joint, conditional forecasts for DNI and prices are formed using an autoregressive moving-average time series model with exogenous weather predictors. We guide dispatch using a mixed-integer programming model, but in order to evaluate performance we use the System Advisor Model (SAM) of the National Renewable Energy Laboratory. SAM is a techno-economic simulation model that accounts for plant thermodynamics with higher fidelity. Our conditional DNI forecasts improve annual revenue by 4%–12% over using historical forecasts based on data from previous years. Conditional price forecasts improve annual revenue by 6%–19% in the real-time market over analogous historical forecasts. Updating these forecasts every six hours, rather than every 24 h, further improves annual revenue by 5%–6%. Here, we also investigate a method that values terminal inventory in our dispatch optimization model, again when used in a rolling-horizon scheme.
The U.S. Department of Energy has identified a third generation of concentrated solar power (Gen3 CSP) technologies to minimize cost of CSP produced electricity. By developing these technologies further, it is forecasted that Gen3 CSP will meet the levelized cost of electricity (LCOE) SunShot target of 6 cents/kWh to compete with dominant, conventional nonrenewable energy sources (1). The focus for advancing CSP systems for Gen3 is to increase overall system efficiency. Thus, reevaluating second-generation systems, superheated steam-turbine power cycles, and implementing more advanced power cycles is essential. Specifically, it has been identified that a supercritical carbon dioxide (sCO 2 ) Brayton cycle can increase the net thermal-to-electric efficiency to over 50% for CSP power tower configurations (2). Compared to conventional superheated steam Rankine cycle systems, more extreme operating conditions are required and pose critical barriers to overcome in the field of materials and manufacturing for Gen3 CSP.
Preliminary design data are presented for a concentrating solar collector including an attitude controller. Provided are schedules, technical status, all documents required for preliminary design, and other program activities.
Testing and evaluation results for the structural design of the concentrating solar collector and the attitude control system are reported.
45-page report contains results of performance evaluation of line-concentrating solar collector. Collector employs parabolic trough to direct Sunlight to line along its focal axis, along which lies a black-chrome plated receiver tube covered by a glass tube containing still air. Reflective trough has aluminum-mirror surface covered with metallized acrylic film. Array of four collectors, positioned end to end was used for evaluation. Array was driven by single drive mechanism which was controlled by electronic tracking device.
The Space Station will represent the first time that a solar dynamic power system will be used to generate electrical power in space. In a system such as this, sunlight is collected and focused by a solar concentrator onto the receiver of a heat engine which converts the energy into electricity. The concentrator must be capable of collecting and focusing as much of the incident sunlight as possible, and it must also withstand the atomic oxygen bombardment which occurs in low Earth orbit (LEO). This has led to the development of a system of thin film coatings applied to the concentrator facet surface in a chamber designed especially for this purpose. The system of thin film coatings employed gives both the necessary degree of reflectance and the required protection from the LEO atomic oxygen environment.
Solar power has innate issues with weather, grid demand and time of day, which can be mitigated through use of thermal energy storage for concentrating solar power (CSP). Nuclear reactors, including lead-cooled fast reactors (LFRs), can adjust power output according to demand; but with high fixed costs and low operating costs, there may not be sufficient economic incentive to make this worthwhile. We investigate potential synergies through coupling CSP and LFR together in a single supercritical CO 2 Brayton cycle and/or using the same thermal energy storage. Combining these cycles allows for the LFR to thermally charge the salt storage in the CSP cycle during low-demand periods to be dispatched when grid demand increases. The LFR/CSP coupling into one cycle is modeled to find the preferred location of the LFR heat exchanger, CSP heat exchanger, sCO 2 -to-salt heat exchanger (C2S), turbines, and recuperators within the supercritical CO 2 Brayton cycle. Three cycle configurations have been studied: two-cycle configuration, which uses CSP and LFR heat for dedicated turbocompressors, has the highest efficiencies but with less component synergies; a combined cycle with CSP and LFR heat sources in parallel is the simplest with the lowest efficiencies; and a combined cycle with separate high-temperature recuperators for both the CSP and LFR is a compromise between efficiency and component synergies. Additionally, four thermal energy storage charging techniques are studied: the turbine positioned before C2S, requiring a high LFR outlet temperature for viability; the turbine after the C2S, reducing turbine inlet temperature and therefore power; the turbine parallel to the C2S producing moderate efficiency; and a dedicated circulator loop. While all configurations have pros and cons, use of a single cycle offers component synergies with limited efficiency penalty. Using a turbine in parallel with the C2S heat exchanger is feasible but results in a low charging efficiency, while a dedicated circulator loop offers flexibility and near-perfect heat storage efficiency but increasing cost with additional cycle components.
As the world increases renewable energy deployment, there is an increasing interest in hybridizing various generation and storage technologies to maximize net benefit to the developer and/or off-taker. A particularly interesting combination of renewable technologies is concentrating solar power (CSP) with thermal energy storage (TES), photovoltaics (PV), and electrochemical battery energy storage (BESS). Due to the system complexity of CSP technology, it is difficult to evaluate the technological and financial performance of a CSP-PV hybrid system without detailed modeling of annual operations. To address this challenge, we have developed a modeling framework for evaluating the performance and financial viability of CSP systems hybridized with PV and battery technologies. This modeling effort incorporates CSP tower and trough systems into an existing modeling tool recently developed by NREL referred to as the Hybrid Optimization and Performance Platform (HOPP). This report outlines the modeling methodology as well as preliminary results from example case studies conducted using the model. The methodology describes: (i) the integration of CSP tower and troughs into HOPP using python interfaces to access System Advisor Model (SAM) underlining technology models, (ii) the mathematical formulation of the mixed integer linear program dispatch optimization model which optimizes operations of storage asset to either maximize system revenue or minimize operating cost while load following, (iii) the design analysis methods implemented within HOPP, and (iv) simulation clustering for the purposes of reducing computational expense. We exercise the model using a case study of a future scenario where we assume (i) CSP and PV technologies achieve the 2030 cost targets provided by the Solar Energy Technologies Office (SETO), (ii) battery costs reduce to the 2030 mid cost projection presented by NREL. Lastly, (iii) electricity prices for southern California in 2030 are provided by NREL's Cambium database, and (iv) a capacity payment of $150/kW-yr based on the system capacity factor during the to 100 net-load hours.