Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computational imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Real-time image denoising of mixed Poisson–Gaussian noise in fluorescence microscopy images using ImageJ

Fluorescence microscopy imaging speed is fundamentally limited by the measurement signal-to-noise ratio (SNR). To improve image SNR for a given image acquisition rate, computational denoising techniques can be used to suppress noise. However, common techniques to estimate a denoised image from a single frame either are computationally expensive or rely on simple noise statistical models. These models assume Poisson or Gaussian noise statistics, which are not appropriate for many fluorescence microscopy applications that contain quantum shot noise and electronic Johnson–Nyquist noise, therefore a mixture of Poisson and Gaussian noise. In this paper, we show convolutional neural networks (CNNs) trained on mixed Poisson and Gaussian noise images to overcome the limitations of existing image denoising methods. The trained CNN is presented as an open-source ImageJ plugin that performs real-time image denoising (within tens of milliseconds) with superior performance (SNR improvement) compared to conventional fluorescence microscopy denoising methods. The method is validated on external datasets with out-of-distribution noise, contrast, structure, and imaging modalities from the training data and consistently achieves high-performance ( > <#comment/> 8 d B ) denoising in less time than other fluorescence microscopy denoising methods.

47 OTHER INSTRUMENTATION↗

Understanding Portability of Automotive Workload: A Case Study with the Points-to-Image Kernel in SYCL on Heterogeneous Computing Platforms

SYCL is a promising programming model for heterogenous computing across vendors’ devices. In this paper, we study whether SYCL can be applied to an automotive workload and its portability on heterogeneous computing platforms. We explain the automotive benchmark, describe our implementations and optimizations of the benchmark, and evaluate the performance of the benchmarks using SYCL and other programming models on heterogeneous computing devices. The study also allows us to have a better understanding of portability of the benchmark across these platforms.

Jin, Zheming↗

Modeling and simulation study for the design of the Fuel Interrogation and Examination using Submersible Tomography Analysis Mk II instrument

Here, the design of a submersible, gamma-ray tomography system for imaging irradiated nuclear fuel is described. The system—named Fuel Interrogation and Examination using Submersible Tomography Analysis (FIESTA) Mk. II—is a variation on a previous Mk. I I design, which was developed to non-destructively image fuel capsules irradiated in the Advanced Test Reactor at the Idaho National Laboratory. The FIESTA system uses a combination of transmission computed tomography and emission computed tomography to image the restructuring and fission product migration at different points of burnup. Changes made to FIESTA Mk. I reflect the revised design requirements and a need to reduce background noise, largely originating from downscattered photons from fuel and transmission source. The computational design and radiation transport simulations are described.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Image processing tools for petabyte-scale light sheet microscopy data

Light sheet microscopy is a powerful technique for high-speed three-dimensional imaging of subcellular dynamics and large biological specimens. However, it often generates datasets ranging from hundreds of gigabytes to petabytes in size for a single experiment. Conventional computational tools process such images far slower than the time to acquire them and often fail outright due to memory limitations. To address these challenges, we present PetaKit5D, a scalable software solution for efficient petabyte-scale light sheet image processing. This software incorporates a suite of commonly used processing tools that are optimized for memory and performance. Notable advancements include rapid image readers and writers, fast and memory-efficient geometric transformations, high-performance Richardson–Lucy deconvolution and scalable Zarr-based stitching. These features outperform state-of-the-art methods by over one order of magnitude, enabling the processing of petabyte-scale image data at the full teravoxel rates of modern imaging cameras. The software opens new avenues for biological discoveries through large-scale imaging experiments.

97 MATHEMATICS AND COMPUTING↗

CIRCLEZ : Reliable photometric redshifts for active galactic nuclei computed solely using photometry from Legacy Survey Imaging for DESI

Photometric redshifts for galaxies hosting an accreting supermassive black hole in their center, known as active galactic nuclei (AGNs), are notoriously challenging. At present, they are most optimally computed via spectral energy distribution (SED) fittings, assuming that deep photometry for many wavelengths is available. However, for AGNs detected from all-sky surveys, the photometry is limited and provided by a range of instruments and studies. This makes the task of homogenizing the data challenging, presenting a dramatic drawback for the millions of AGNs that wide surveys such as SRG/eROSITA are poised to detect. This work aims to compute reliable photometric redshifts for X-ray-detected AGNs using only one dataset that covers a large area: the tenth data release of the Imaging Legacy Survey (LS10) for DESI. LS10 provides deep grizW1-W4 forced photometry within various apertures over the footprint of the eROSITA-DE survey, which avoids issues related to the cross-calibration of surveys. We present the results from CIRCLEZ, a machine-learning algorithm based on a fully connected neural network. CIRCLEZ is built on a training sample of 14 000 X-ray-detected AGNs and utilizes multi-aperture photometry, mapping the light distribution of the sources. The accuracy (σNMAD) and the fraction of outliers (η) reached in a test sample of 2913 AGNs are equal to 0.067 and 11.6%, respectively. The results are comparable to (or even better than) what was previously obtained for the same field, but with much less effort in this instance. We further tested the stability of the results by computing the photometric redshifts for the sources detected in CSC2 and Chandra-COSMOS Legacy, reaching a comparable accuracy as in eFEDS when limiting the magnitude of the counterparts to the depth of LS10. The method can be applied to fainter samples of AGNs using deeper optical data from future surveys (for example, LSST, Euclid), granting LS10-like information on the light distribution beyond the morphological type. Along with this paper, we have released an updated version of the photometric redshifts (including errors and probability distribution functions) for eROSITA/eFEDS.

79 ASTRONOMY AND ASTROPHYSICS↗

Individual Wave Detection and Tracking within a Rotating Detonation Engine through Computer Vision Object Detection applied to High-Speed Images

Known for their simplistic design and continuous detonation, rotating detonation engines (RDEs) constitute a majority of current pressure gain combustion (PGC) research efforts. Experimental RDE operation times have been continuously extended through the use of rig cooling techniques. As the window of observable behavior is expanded, and as the technology matures toward eventual integration within gas turbines, monitoring techniques must evolve to better match industrial diagnostics. High-speed image analysis techniques prove useful to capture and evaluate the unsteady detonation behavior within the RDE. Traditional image analysis techniques, however, require extensive processing times which prohibit simultaneous monitoring. To better address this problem, a computer vision object detection methodology is proposed to quickly detect individual detonation waves within a single down-axis image. Detonation waves are detected in individual images by the implemented computer vision method You Only Look Once (YOLO) object detection network. In order to detect detonation waves, the network must first be trained using RDE images of interest, for which each required phase of network development is outlined. Detection of waves is improved through proper treatment of the collected image set, variation of Intersection over Union (IoU) and confidence thresholding, and through a parametric study of annotation dimensions. Each detected wave is described by its location and rotational direction, and locations are tracked to calculate wave velocity across each frame, leading to a timestep resolution of 20 µs. Wave velocities are also calculated through a series of frames, leading to a suitable average velocity estimation using as few as 10 frames. Uncertainty analysis accounting for variation in camera framerate, pixel width and annotation centroid locations estimates a total uncertainty of ±4.3% for velocity calculations, using the smallest annotation boxes. This method offers great reductions in processing times, as a step toward real-time monitoring of detonation waves within an RDE. Improving on previous studies, this technique is impartial to wave modes not included in the original training set and calculates wave velocities independent of high-speed pressure data. The ability to isolate waves within predicted bounding boxes will likely facilitate analysis of pixel intensity variation as an estimation of wave strength in future work.

Johnson, Kristyn↗

Automated Scoring of Morphological Changes in Images of Pentaerythritol Tetranitrate

Recent advances in characterization techniques that generate large datasets of material microstructure images require robust, automated image-processing. We applied an unsupervised anomaly detection method called feature anomaly detection system (FADS) to automatically detect and quantify microstructure changes in images of the explosive pentaerythritol tetranitrate (PETN) aged at various temperatures. We demonstrated the FADS approach on two-dimensional images extracted from computed tomography scans, but the same technique can be readily applied to other imaging modalities. FADS calculates anomaly scores on the basis of differences in filter activations of nominal and test data in pretrained convolutional neural networks. The FADS scores successfully differentiated between pristine PETN and PETN aged at a temperature where material coarsening occurred. Morphological metric analysis of segmented images verified observed trends in FADS scores as a function of aging temperature and aging time, specifically by calculating volume fractions, specific boundary lengths, two-point correlation functions, and local thicknesses. Here, the FADS technique has two important advantages compared to traditional morphological analysis: First, it uses grayscale images as input, rather than images that are segmented to separate the appropriate phases; and second, FADS scores capture any type of changes among image sets, rather than requiring prior knowledge or selection of a relevant set of metrics.

Accelerated aging↗

Mixture Model Framework for Traumatic Brain Injury Prognosis Using Heterogeneous Clinical and Outcome Data

Prognoses of Traumatic Brain Injury (TBI) outcomes are neither easily nor accurately determined from clinical indicators. This is due in part to the heterogeneity of damage inflicted to the brain, ultimately resulting in diverse and complex outcomes. Using a data-driven approach on many distinct data elements may be necessary to describe this large set of outcomes and thereby robustly depict the nuanced differences among TBI patients’ recovery. In this work, we develop a method for modeling large heterogeneous data types relevant to TBI. Our approach is geared toward the probabilistic representation of mixed continuous and discrete variables with missing values. The model is trained on a dataset encompassing a variety of data types, including demographics, blood-based biomarkers, and imaging findings. In addition, it includes a set of clinical outcome assessments at 3, 6, and 12 months post-injury. The model is used to stratify patients into distinct groups in an unsupervised learning setting. We use the model to infer outcomes using input data, and show that the collection of input data reduces uncertainty of outcomes over a baseline approach. In addition, we quantify the performance of a likelihood scoring technique that can be used to self-evaluate the extrapolation risk of prognosis on unseen patients.

97 MATHEMATICS AND COMPUTING↗

Europium-doped barium chloride storage phosphor plate synthesized by pulsed laser deposition

In computed radiography, scattering of the stimulation light by the storage phosphor crystals in the imaging plates negatively impacts spatial resolution. Storage phosphor plates with thinner phosphor layers have been developed to reduce scattering distance and increase spatial resolution, although at the expense of reduced x-ray absorption. The authors hypothesize that a transparent or translucent nanostructured film, containing a much higher percentage of storage phosphor crystals than achievable in bulk glass-ceramic materials made by conventional methods, may have acceptable photostimulated luminescence efficiency and imaging performance characteristics greater than commercial imaging plates. Films were produced via pulsed laser deposition by alternating target materials of the storage phosphor BaCl 2 :Eu 2+ and either silica or silicon. X-ray diffraction and photoluminescence characterization were conducted to confirm the presence of BaCl 2 :Eu 2+ crystallites. The films were able to store optical data and be read out to produce x-ray radiographs demonstrating 50-mu m spatial resolution. The performance of the experimental storage phosphor plates was compared to commercially available imaging plates. The authors demonstrate for the first time the synthesis of a glass-ceramic imaging plate for computed radiography by pulsed laser deposition.

36 MATERIALS SCIENCE↗

Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging

In this paper, the imaging dose and scan time have been considered as the two major constraints for routine benchtop x-ray fluorescence computed tomography (XFCT) imaging. One way to address this issue is to acquire x-ray fluorescence (XRF) signals in parallel through a 2D array of single-crystal detectors or a pixelated detector along with the cone-beam x-ray source. To identify a detector system suitable for this purpose, a commercially available, fully spectroscopic cadmium telluride (CdTe) pixelated detector, HEXITEC (High-Energy X-ray Imaging Technology), was tested under the experimental conditions optimized for benchtop XFCT imaging of gold nanoparticles (GNPs). Specifically, two different parallel-hole stainless steel collimators were fabricated and coupled with the detector for seamless integration into our existing benchtop cone-beam XFCT system. After the detector deployment, this benchtop XFCT system was used to detect XRF photons from GNP-loaded phantoms. A pixel-merging algorithm was introduced to enhance the sensitivity of XRF photon detection thereby minimizing the scan time. The effect of pixel-level charge sharing correction algorithms was investigated within the context of benchtop XFCT imaging. The detector energy resolution, in terms of the full width at half maximum (FWHM) values at different gold K-shell XRF energies, was also determined. Of the two charge sharing correction algorithms examined, the charge sharing addition gave better sensitivity than the charge sharing discrimination (csd). On the other hand, under the current experimental conditions, the energy resolution of the HEXITEC detector was the best with the csd and estimated to be 1.56 keV FWHM at 66-69 keV photon energy. Overall, despite some degradation of the detector energy resolution (compared with typical single crystal CdTe detectors), the HEXITEC detector enabled parallel data acquisition under the experimental conditions typical of benchtop XFCT imaging and operated well within our benchtop XFCT setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scaling deep learning for material imaging with a pseudo 3D model for domain transfer

The recent introduction of deep learning methods for image processing has greatly advanced the characterization of materials using three-dimensional (3D) X-ray imaging techniques. However, deep learning models often have difficulty performing consistently across images owing to unavoidable variations in imaging conditions, which create inconsistencies even for the same material. As a result, networks must frequently be retrained for new datasets, limiting their applicability and generalization. Thus, it is critical to reduce the variations between images to enable a single model to process multiple datasets. Herein, we introduce P3T-Net, a pseudo-3D domain transfer network that transfers diverse 3D images into a uniform domain before processing using deep learning models. Remarkably, P3T-Net enables the reuse of previously trained networks for processing new images and considerably reduces the computational cost of transferring 3D images across domains. These unique capabilities were demonstrated in the following scenarios: (i) image enhancement of fast scans for geological rock and hydrogen fuel cells, (ii) enhancement of images to match the quality of multi-source imaging for lithium-ion batteries, (iii) accurate segmentation of images captured under different conditions, and (iv) tera-scale 3D transfer (10 11 voxels) on a single GPU. Overall, the proposed approach addresses cross-domain inconsistencies across various materials and conditions, thereby enabling more robust and generalizable deep learning solutions for a wide range of material imaging tasks.

25 ENERGY STORAGE↗

System, method, and computer-accessible medium for remote sensing of the electrical distribution grid with hypertemporal imaging

An exemplary system, method, and computer-accessible medium for determining a property(ies) regarding an electrical grid(s) can be provided, which can include, for example, receiving a video(s) of the electrical grid(s), determining a flicker(s) in the electrical grid(s) based on the video(s), and determining the property(ies) based on the flicker(s). The flicker(s) can be a 120 Hertz flicker. The flicker(s) can be a flicker in a light(s) recorded in the video(s). A frequency and a phase of the flicker(s) can be determined.

Bianco, Federica B.↗

Coupled Transport, Reactivity, and Mechanics in Fractured Shale Caprocks

Abstract Shales are low‐permeability caprocks that confine fluid, such as CO 2 , nuclear waste, and hydrogen, in storage formations. Stress‐induced fractures in shale caprocks provide pathways for fluid to leak and potentially contaminate fresh water aquifers. Fractured shales are also increasingly considered as resources for CO 2 sequestration, enhanced geothermal, and unconventional energy recovery. Injecting reactive fluids into shales introduces chemical disequilibrium, causing an onset of a series of dissolution, precipitation, and fines mobilization mechanisms. The reactions have rapid kinetics and significant impact on porosity and permeability; consequently, flow and storage properties of caprocks. While previous research has explored the separate effects of these reactions, this study aims to uncover their simultaneous occurrence and collective influence. This study unveils these highly coupled transport and reactivity mechanisms by tracking and visualizing the reaction‐induced alterations in the matrix, microcracks, and fractures of shales over time. We conducted brine injection experiments sequentially at pH 4 and 2 in a naturally fractured Wolfcamp shale sample while simultaneously imaging the dynamic processes using X‐ray computed tomography (CT). CT images are validated by finer resolution images obtained using micro‐CT and scanning electron microscopy. We also tracked the sample permeability and fluid chemistry using brine permeability and inductively coupled plasma mass spectrometry, respectively. Findings show that fluid primarily flowed through fractures, dissolving reactive minerals and mobilizing fines on fracture surfaces. Dissolution of fracture asperities under confining stress resulted in the closing of fractures. Clogging in narrow fracture pathways, caused by fines accumulation, diverted fluid flow into matrix pores.

58 GEOSCIENCES↗

Multimode turbulent flow measurements using magnetic resonance imaging- and laser-based techniques and computational fluid dynamics simulations

We studied the flow field characteristics of a turbulent flow over a regularized cube array with a perpendicular injection flow through the floor between the second and third cubical elements, representing the complex flow interactions of a 3D jet and the wake flows behind cubical obstacles. Four different experimental measurements were performed: two magnetic resonance imaging-based measurements for three-dimensional three-component velocity (MRV) and concentration (MRC) and two laser-based techniques, particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF), for two-dimensional two-component velocity and concentration measurement, respectively. The mainstream Reynolds number is Re = 15 000⁠, based on the primary inlet velocity U m and channel height D H ⁠, whereas the injector Reynolds number is Re j = 3400⁠, based on the injector velocity U j and the injector's exit width D j ⁠. Numerical simulations were performed for the studied flow configuration of turbulent flow over a regularized cube array using Reynolds-averaged Navier–Stokes (RANS) and large-eddy simulation (LES) approaches. Results obtained from experimental measurements—including MRV, MRC, PIV, and PLIF—as well as RANS and LES simulations are discussed and compared along several horizontal and vertical planes of the studied configuration. In addition, 3D turbulent flow structures, such as leading-edge vortex, horseshoe vortex, and jet shear-layer vortex, and the isosurfaces of scalar concentration successfully revealed by MRV and MRC techniques were found to be in very good agreement with those 3D features extracted from RANS and LES simulations. In conclusion, the high-resolution experimental and numerical database obtained from this study could be useful for validation and verification of numerical codes.

Computational fluid dynamics↗

Efficient and Flexible Sensitivity Matrix Computation for Adaptive Electrical Capacitance Volume Tomography

Electrical capacitance tomography is a widely used sensor modality for flow imaging in many industrial settings. Adaptive Electrical Capacitance Volume Tomography (AECVT) extends the capabilities of traditional ECT by enabling direct volumetric imaging and an improved resolution. Construction of the sensitivity matrix is a necessary step to obtain flow images. This step requires computation of the electric field inside the sensing domain, which is done via a typical field solver such as the finite element method. In this work, we present an efficient and flexible method to construct the sensitivity matrix for Adaptive Electrical Capacitance Volume Tomography (AECVT) based on individual electrode segment excitations and their judicious combination to form desired matrix elements. We illustrate how the proposed method yields the same sensitivity matrix as the traditional method but at a much lower computational cost. Once all segment contributions are obtained, we also indicate how the proposed method, unlike the traditional approach, can generate the sensitivity matrix on demand for an arbitrary combination of synthetic electrodes and obviating the need for any additional field computations. Finally, we present image reconstruction results for two different experimental scenarios where the mutual capacitance data and the corresponding sensitivity vectors are obtained through the proposed measurement combination scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of open‐source three‐dimensional reconstruction pipelines for maize‐root phenotyping

Abstract Understanding three‐dimensional (3D) root traits is essential to improve water uptake, increase nitrogen capture, and raise carbon sequestration from the atmosphere. However, quantifying 3D root traits by reconstructing 3D root models for deeper field‐grown roots remains a challenge due to the unknown tradeoff between 3D root‐model quality and 3D root‐trait accuracy. Therefore, we performed two computational experiments. We first compared the 3D model quality generated by five state‐of‐the‐art open‐source 3D model reconstruction pipelines on 12 contrasting genotypes of field‐grown maize roots. These pipelines included COLMAP, COLMAP+PMVS (Patch‐based Multi‐View Stereo), VisualSFM, Meshroom, and OpenMVG+MVE (Multi‐View Environment). The COLMAP pipeline achieved the best performance regarding 3D model quality versus computational time and image number needed. In the second test, we compared the accuracy of 3D root‐trait measurement generated by the Digital Imaging of Root Traits 3D pipeline (DIRT/3D) using COLMAP‐based 3D reconstruction with our current DIRT/3D pipeline that uses a VisualSFM‐based 3D reconstruction on the same dataset of 12 genotypes, with 5–10 replicates per genotype. The results revealed that (1) the average number of images needed to build a denser 3D model was reduced from 3000 to 3600 (DIRT/3D [VisualSFM‐based 3D reconstruction]) to around 360 for computational test 1, and around 600 for computational test 2 (DIRT/3D [COLMAP‐based 3D reconstruction]); (2) denser 3D models helped improve the accuracy of the 3D root‐trait measurement; (3) reducing the number of images can help resolve data storage problems. The updated DIRT/3D (COLMAP‐based 3D reconstruction) pipeline enables quicker image collection without compromising the accuracy of 3D root‐trait measurements.

09 BIOMASS FUELS↗

Nuclear Canister Corrosion Detection

The software titled "nccd" is used for running residual neural networks (ResNets) on images of nuclear canisters. The software provides only the code for the implementation (based on the fastai library), but it does not share the image data. The compute code allows the use of residual nets (and more generally of other deep learning models) for classifying images from nuclear canisters as corroded. or intact. An image is considered to be corroded if it contains pitting or stress corrosion cracks. The code trains ResNets on image tiles extracted from original images from nuclear canisters, and then implements a classification rule, which can be applied to a validation set to decide if each original image is corroded or intact. The software automates the process of using images taken from nuclear canisters to detect corrosion. It provides also scope for future research directions on the basis of the existing research and code.

Papamarkou, Theodore↗

3D micromechanical simulation of PBX composites

Previous research studied the constitutive response and interface strength of a bonded bicrystal system containing two HMX explosive grains bound with a HTPB polymer binder by performing FE simulations on real geometry imaged with micro Computed Tomography (µCT). The parameters generated from this past study were successfully applied to 2D mesoscale simulations of µCT imaged HMX-HTPB polycrystal samples. Presently, the mechanical response of PBXs containing a Nitro-Plasticized Estane (NPE) binder with similar microstructural geometry to the HMX-HTPB polycrystal samples were studied. Imaging of a HMX-NPE bicrystal sample allowed for simulation of the new material pairing. However, imaging using µCT techniques on the new polycrystal samples was difficult due to the decrease in contrast between the HMX grains and the NPE binder. Mesoscale polycrystal simulations utilizing a single µCT imaged microstructure were performed on a 3D representative volume element (RVE) comparing the delamination behavior and mechanical response of both HMX-HTPB and HMX-NPE PBXs. Furthermore, this technique shows the ability to virtually explore the mechanical response of a range of hypothetical materials that share common microstructural geometric characteristics in addition to studying numerically altered geometries.

36 MATERIALS SCIENCE↗