Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Direct stellarator coil optimization for nested magnetic surfaces with precise quasi-symmetry

We present a robust optimization algorithm for the design of electromagnetic coils that generate vacuum magnetic fields with nested flux surfaces and precise quasi-symmetry. The method is based on a bilevel optimization problem, where the outer coil optimization is constrained by a set of inner least squares optimization problems whose solutions describe magnetic surfaces. The outer optimization objective targets coils that generate a field with nested magnetic surfaces and good quasi-symmetry. The inner optimization problems identify magnetic surfaces when they exist, and approximate surfaces in the presence of magnetic islands or chaos. We show that this formulation can be used to heal islands and chaos, thus producing coils that result in magnetic fields with precise quasi-symmetry. We show that the method can be initialized with coils from the traditional two-stage coil design process, as well as coils from a near-axis expansion optimization. We present a numerical example where island chains are healed and quasi-symmetry is optimized up to surfaces with aspect ratio 6. Another numerical example illustrates that the aspect ratio of nested flux surfaces with optimized quasi-symmetry can be decreased from 6 to approximately 4. In conclusion, the last example shows that our approach is robust and a cold-start using coils from a near-axis expansion optimization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of layer wound epoxy-impregnated coils made from a multifilamentary cable of exfoliated YBCO

The performance and reliability of magnets made from second generation (2G), exfoliated, YBCO conductors are highly improved by use of narrow, stacked, multifilamentary cable instead of a single wide tape. This work reports on tests of five mini-coils wound from 2.4 mm wide ExoCable™, which is comprised of eight, stacked, exfoliated, YBCO filaments. The filaments are coupled electrically through a re-flow process, which results in enhanced electrical connectivity between the adjacent layers. The coils were tested at 77 K (up to 500 A) in liquid nitrogen and at 22 K (up to 700 A) in a conduction-cooled mode. The cable carries 500 A critical current at 77 K. A six-layer coil wound from 10.5 m of the cable, the largest coil created in the study, demonstrates a critical current of 280 A at 77 K at 0.4 T magnetic field on the winding. The coils were fully impregnated with Stycast 1266 and Henkel W19 low-viscosity epoxies. Repeated thermal cycling, to 77 and 22 K, does not degrade the coil's performance. The cable AC loss and the coil winding magnetization are compared with the traditional 2G wide tape pancake geometry at 77 K. We observe a five times reduction of the winding magnetization when the 12 mm tape is replaced by a 2.4 mm cable, which is explained by the smaller magnetic moment of the cable winding. The field hysteresis profiles recorded at 22 and 77 K are presented to demonstrate the effect of the operation temperature on the winding magnetization. A finite element analysis of the winding magnetization shows a good agreement between the experimentally measured trapped field value, and the critical state model prediction. Finally, we discuss the stability of an ExoCable™ coil in a conduction-cooled operation.

2G cables↗

Global stellarator coil optimization with quadratic constraints and objectives

Most present stellarator designs are produced by costly two-stage optimization: the first for an optimized equilibrium, and the second for a coil design reproducing its magnetic configuration. Few proxies for coil complexity and forces exist at the equilibrium stage. Rapid initial state finding for both stages is a topic of active research. Most present convex coil optimization codes use the least square winding surface method by Merkel (NESCOIL), with recent improvements in conditioning, regularization, sparsity, and physics objectives. While elegant, the method is limited to modeling the norms of linear functions in coil current. We present QUADCOIL, a global coil optimization method that targets combinations of linear and quadratic functions of the current. It can directly constrain and/or minimize a wide range of physics objectives unavailable in NESCOIL and REGCOIL, including the Lorentz force, magnetic energy, curvature, field-current alignment, and the maximum density of a dipole array. QUADCOIL requires no initial guess and runs nearly $10$ 2 x faster than filament optimization. Integrating it in the equilibrium optimization stage can potentially exclude equilibria with difficult-to-design coils, without significantly increasing the computation time per iteration. QUADCOIL finds the exact, global minimum in a large parameter space when possible, and otherwise finds a well-performing approximate global minimum. It supports most regularization techniques developed for NESCOIL and REGCOIL. We demonstrate QUADCOIL’s effectiveness in coil topology control, minimizing non-convex penalties, and predicting filament coil complexity with three numerical examples.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Metallurgical Inspection Method to Assess the Damage in Performance-Limiting Nb 3 Sn Accelerator Magnet Coils

The design and production of Nb 3 Sn-based dipole and quadrupole magnets is critical for the realization of the High-Luminosity Large Hadron Collider (HL-LHC) at the European Organization for Nuclear Research (CERN). Nb 3 Sn superconducting coils are aimed at enhancing the bending and focusing strengths of accelerator magnets for HL-LHC and beyond. Due to the brittle nature of Nb 3 Sn, the coil fabrication steps are very challenging and require very careful QA/QC. Flaws in the Nb 3 Sn filaments may lead to quenches, and eventually, performance limitation below nominal during magnet testing. A novel inspection method, including advanced non-destructive and destructive techniques, was developed to explore the root-causes of quenches occurring in performance-limiting coils. The most relevant results obtained for MQXF coils through this innovative inspection method are presented. This approach allows for precise assessment of the physical events associated to the quenches experienced b y magnet coils, mainly occurring under the form of damaged strands with transversely broken sub-elements. Coil-slice preparation, micro-optical observations of transverse and longitudinal cross-sections, and a deep etching technique of copper will be illustrated in the present work, with a focus on the results achieved for a CERN coil from a non-conforming quadrupole magnet prototype, and two coils fabricated in the US, in the framework of the Accelerator Upgrade Project (AUP) collaboration, from two different non-conforming quadrupole magnets, respectively. The results obtained through the proposed inspection method will be illustrated.

43 PARTICLE ACCELERATORS↗

Clinical Outcome of the Visible Coil During Endoscopy After Transcatheter Arterial Embolization for Gastrointestinal Bleeding

Purpose: This study was designed to evaluate the clinical outcome of the visible coil during endoscopy after transcatheter arterial embolization (TAE) for gastrointestinal bleeding. Methods: We retrospectively reviewed the medical records of 1415 patients who underwent TAE for gastrointestinal bleeding between 2001 and 2017. Among these 1415 patients, 70 underwent TAE using coils and consecutive follow-up endoscopy. Finally, 11 patients with an extravascular coil seen on follow-up endoscopic examination were included in this study. We evaluated the underlying cause of the gastrointestinal bleeding, the technical and clinical success rates, the type of extravascular coil after TAE, and the clinical outcomes of the extravascular coil seen on follow-up endoscopic examination. Results: Of the 11 patients, the most common underlying cause of gastrointestinal bleeding was a duodenal ulcer (n = 7). On angiography, the bleeding artery was most commonly found in the gastroduodenal artery (n = 6). The technical success and clinical success rates of TAE were 100% and 90.9%, respectively. The type of extravascular coil found on endoscopic examination was classified by submucosal migration (n = 6) and protrusion (n = 5). On second-look endoscopic evaluation, 10 of 11 (90.9%) patients showed healing ulceration. On the final-look endoscopic evaluation, healing ulceration without further bleeding was seen in one (9.1%) patient and scar formation was seen in ten (90.9%) patients. Conclusions: Extravascular coil after TAE for gastrointestinal bleeding is rare, and the most common underlying cause is duodenal ulcer bleeding. The extravascular coils eventually show a healing process with adequate treatment of underlying bowel pathologies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Effects of Ferromagnetic Disks on AC Losses in HTS Pancake Coils with Nonmagnetic and Magnetic Substrates

Performance improvement of high-temperature superconducting (HTS) pancake coil is of paramount importance for its application in electrical facilities. In this paper, the utilization of ferromagnetic disks including weak magnetic material and strong magnetic material is investigated through numerical simulations for the aim of reducing the AC loss. Both the nonmagnetic and magnetic substrates are considered for the rare-earth-barium-copper-oxide coated conductor tapes wounded into the pancake coil. In order to analyze the influences of ferromagnetic disks on the maximum allowable currents and AC losses of nonmagnetic substrate-based coil and magnetic substrate-based coil, a self-consistent model based on the A-formulation is adopted to calculate the critical current and a 2D axisymmetric model built on the H-formulations is established to calculate the AC loss. According to the simulation results, it is found that ferromagnetic disks especially the strong magnetic disk are slightly detrimental to the critical currents of the pancake coils. Nevertheless, the presence of large background field weakens the effects of ferromagnetic disks. The simulation results also indicate that strong magnetic disks achieve about 50% reduction of the AC loss in the nonmagnetic substrate-based coil, and the AC loss of the magnetic substrate-based coil can be increased or reduced with strong magnetic disks depending on the applied current amplitude. The utilization of strong magnetic disks leads to the enhancement of the AC loss in the magnetic substrate-based coil at lower current and to the reduction of it at larger current.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Use of current-potential patches to obtain fundamental improvements to the coils of magnetic fusion devices

A central issue in the design of tokamaks or stellarators is the coils that produce the external magnetic fields. The freedom that remains unstudied in the design of coils is enormous. This freedom could be quickly studied computationally at low cost with high reliability. In particular, the space between toroidal field and modular coils that blocks access to the plasma chamber could be increased by a large factor. The concept of current-potential patches, which was developed in Todd Elder's thesis, provides a method for separating the study of the feasibility of coils with attractive physics properties from the engineering design of specific coils. In addition to enhanced accessibility, coils can be designed for increased plasma-coil separation, insensitivity to coil position errors, and plasma control.

Boozer, Allen H. [Columbia Univ., New York, NY (Un↗

Physics basis for design of 3D coils in tokamaks

Recent progress in 3D tokamak modeling is now leveraged to create a conceptual design of new external 3D field coils for the DIII-D tokamak. In this work generalized perturbed equilibrium code is used to determine optimally efficient spectrum for driving total, core, and edge neoclassical toroidal viscosity torque. These fundamental modes of 3D control are shown to have consistent outboard structures across a wide variety of plasma scenarios and machines. Given these target spectra, the currents and 3D geometry of multiple coils can be optimized to increase efficient drive for the physics of interest without undesired secondary effects. Here, this nonlinear optimization is demonstrated using the flexible optimized coils using space-curves code. The optimized coils are individually distorted in space, creating toroidal 'arrays' containing a variety of shapes that often wrap around a significant poloidal extent of the machine. Importantly, efficient coupling can be maintained even when enforcing large distances between coils and the plasma during the geometric optimization of coil designs. Finally, the physics-driven optimization presented here thus provides a practical path to utilizing coils built on the exterior of the vacuum chamber in future reactors to obtain the powerful 3D field benefits demonstrated on current machines with close, internal coils.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of the Heater-Coil Electrical Insulation for the HL-LHC Low Beta Quadrupoles

In the framework of the HL-LHC project, the present LHC low-β superconducting quadrupoles will be substituted with higher performance Nb 3 Sn magnets (MQXF) with 11.4 T coil peak field. MQXF coils are impregnated with epoxy resin to reduce risk of stress concentration on the brittle conductor. The magnet quench protection is provided by CLIQ and quench heaters to ensure a redundant system. Quench heaters are impregnated with the coils in order to have suitable thermal contact with them, and to prevent the hot spot temperature from exceeding 350K during normal operation in case of a quench. Quench heaters are insulated from the coil by S-2 Glass and polyimide. Here, the test of the first MQXF prototype (4 m long) MQXFAP1 was stopped by a coil-to-ground short circuit triggered by a heater-to-coil short. This issue triggered a root analysis of the causes of this short. Here we prove that the use of a non-conforming cloth in coil impregnation, further weakened by non-conforming high voltage test, has triggered the shorts. Moreover, we present an analysis of the heater-to-coil insulation strength, showing the role of blistering phenomena and how they are triggered by a combination of magnet powering and heater firing.

43 PARTICLE ACCELERATORS↗

Development of a 120-mm Aperture Nb 3 Sn Dipole Coil With Stress Management

This paper describes a 120-mm aperture 2-layer dipole coil with stress management (SM) developed at Fermilab based on cos-theta coil geometry. A model of the coil support structure made of plastic was printed using additive manufacturing technology and used for practice coil winding. The real coil support structure was printed using the 316 stainless steel. The results of the SM structure size control and the key coil fabrication steps are reported in the paper. Finally, the design of coil SM structure and the coil FEA in the dipole mirror test configurations are presented and discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Commissioning of the Power Supplies and Coils of the SMART Tokamak

The small aspect ratio tokamak (SMART) is a spherical tokamak (ST) that offers unique capabilities for studying the potential of negative triangularity. It has been designed, constructed, and is currently being operated by the Plasma Science Fusion Technology (PSFT) Laboratory at the University of Seville. SMART has a total of 21 coils, organized into seven independent circuits and driven by five modular power supplies (PS). The PS operation relies on switching converter technology based on IGBT and supercapacitors (SCs). The PS delivers predefined current waveforms to the copper coil system consisting of the central solenoid (CS), 12 toroidal field (TF) coils, three series pairs of poloidal field (PF) coils, and two independent PF coils. This study details the commissioning and validation of the PS toroidal and solenoid coils, as well as the assembly of coils in SMART. The maximum rated current and slope were measured, along with the series impedance of the coils, the output current ripple, and the noise levels. The internal parameters of the SCs were measured, and optimized current profiles were proposed to enhance overall performance. A comparison has been made between the theoretical values and the experimental results, providing insight into the performance of the PS and areas for improvement.

Power electronics↗

Development of Magnesium Diboride Superconducting Coils for Nuclear Physics Application

The primary objective of this project is to develop an affordable magnet technology at 10-25K and then take it to a level that it can be considered mature enough to be used in a real Nuclear Physics accelerator system. We believe that because of the lower cost of magnesium diboride (MgB2) as compared to the other HTS, it offers the best such chance. Once successfully demonstrated, this exciting and innovative technology could potentially revolutionize the field the same way the conventional superconducting NbTi magnets did several decades ago. MgB2 magnets could reduce the cost of ownership (capital +operation) while enhancing performance. Another innovation is the overall cooling scheme where the exhaust gas of an existing superconducting magnet cools the inner tube which conduction cools the MgB2 coils. In several instances during the upgrade of existing facilities or designing new facilities in the Nuclear Physics or High Energy Physics communities, it is found that magnets made neither with copper coils nor with conventional superconducting NbTi coils offer an acceptable solution. Whereas copper coils limit the performance of the machine and consume large amount of power, NbTi require 4 K cryogenic facilities. This is particularly applicable in those Nuclear Physics machines where the magnetic field requirements are rather modest. One such case has been found in the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory (BNL) where an e-lens system is under construction to increase RHIC luminosity. In this case, magnesium diboride (MgB2) operating at 10-25 K seems to offer an exciting and practical solution. The main objective in Phase II is to demonstrate the reliability and robustness of the MgB2 coil technology, so that it is ready for use in RHIC and other user facilities. We will do this by fabricating several MgB2 coils and by conducting an exhaustive series of lifetime cycle tests. The tests will involve about a thousand ramp-up and ramp-down cycles, about 20 over current or thermal-excursions hitting the quench limit and about 10 thermal cycles. Phase II will begin with a design modeling effort of the MgB2 coils for the e-lens system with enough detail so that the magnetic, thermal and stress requirements can be understood for the fabrication and testing of representative MgB2 coils. After the technology is proven in Phase II for reliability, we will propose to use this in Phase III to upgrade RHIC e-lens system for improved luminosity performance and expect that more applications will follow in other accelerator and medical facilities.

99 GENERAL AND MISCELLANEOUS↗

Transient voltage-reversal in transformers with multiple secondary coils

By using a transformer with multiple secondary coils, a single unipolar power source can drive multiple loads that have different steady-state operating-voltage requirements. We show that, during initial turn-on, a transient voltage that is opposite in sign to the operating voltage can be induced in one or more of the secondary coils. This is because the surging currents in the coils during turn-on produce a strong inductive interaction between all the coils. In a particular secondary coil, the voltage induced by a neighboring secondary can be larger, and opposite in sign to, the voltage directly induced by the primary coil. The effect is transient because, when the secondary circuits reach their steady-state operating currents, they no longer couple inductively to each other. We also show that, during the turn-on period, the voltage induced in a secondary coil can be significantly larger than its steady-state voltage. These transient effects are controlled by the values of the "coil-coupling" parameters, which are functions of the transformer geometry and of the magnetic permeability and electrical resistivity of the materials used. The results are derived from the circuit equations, and verified using PSpice simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A dedicated mirror-magnet experiment to study quench characteristics and dependencies in $Nb_{3}Sn$ coils and explore improvements of diagnostics capabilities

A single Nb3Sn short quadrupole coil in a mirror-magnet configuration was employed to investigate a wide range of phenomena and to serve as test-bed for diagnostics developments. A configurable array of spot-heaters was installed on the inner coil surface for control of induced quench conditions. Several different quench antenna arrays were positioned along the coil inner surface, and included significant sensor overlap for assessment of their relative efficiency and operation. Multiple acoustic sensors were placed on the pole and at coil ends. Optical fibers in grid configurations were put in different places on the coil and magnet for strain assessment, along with standard resistive strain gauges. Current spikes in the magnet circuit were monitored. This plethora of instrumentation aimed to support investigations on induced and spontaneous quenches, among other goals, and was supplemented by standard voltage-tap-based measurements. Voltage tap data of induced quenches from various spot-heater configurations was investigated for similarities to voltage development in spontaneous quenches. Quench antennas provided insights about current redistribution in the quenching coil and coil splices. The Quench Current-boosting Device was applied and the effect on coil training examined. This paper describes motivations behind the research, the overall test setup and main results.

Stoynev, Stoyan [Fermilab]↗

Undulator Long Coil Measurement System Tests

The first and second field integrals in the LCLS undulators must be below a specified limit. To accurately measure the field integrals, a long coil system is used. This note describes a set of tests which were used to check the performance of the long coil system. A long coil system was constructed to measure the first and second field integrals of the LCLS undulators. The long coil measurements of the background fields were compared to field integrals obtained by sampling the background fields and numerically calculating the integrals. This test showed that the long coil has the sensitivity required to measure at the levels specified for the field integrals. Tests were also performed by making long coil measurements of short magnets of known strength placed at various positions The long coil measurements agreed with the known field integrals obtained by independent measurements and calculation. Our tests showed that the long coil measurements are a valid way to determine whether the LCLS undulator field integrals are below the specified limits.

43 PARTICLE ACCELERATORS↗

An active homopolar magnetic bearing with high temperature superconductor (HTS) coils and ferromagnetic cores

A proof-of-feasibility demonstration showed that high temperature superconductor (HTS) coils can be used in a high-load, active magnetic bearing in liquid nitrogen. A homopolar radial bearing with commercially wound HTS (Bi 2223) bias and control coils produced over 200 lb (890 N) radial load capacity (measured non-rotating) and supported a shaft to 14000 rpm. The goal was to show that HTS coils can operate stably with ferromagnetic cores in a feedback controlled system at a current density similar to that in Cu in liquid nitrogen. Design compromises permitted use of circular coils with rectangular cross section. Conductor improvements will eventually permit coil shape optimization, higher current density and higher bearing load capacity. The bias coil, wound with non-twisted, multifilament HTS conductor, required negligible power to carry its direct current. The control coils were wound with monofilament HTS sheathed in Ag. These dissipated negligible power for direct current (i.e. for steady radial load components). When an alternating current (AC) was added, the AC component dissipated power which increased rapidly with frequency and quadratically with AC amplitude. In fact at frequencies above about 2 hz, the effective resistance of the control coil conductor actually exceeds that of the silver which is in electrical parallel with the oxide superconductor. This is at least qualitatively understandable in the context of a Bean-type model of flux and current penetration into a Type II superconductor. Fortunately the dynamic currents required for bearing stability are of small amplitude. These results show that while twisted multifilament conductor is not needed for stable levitation, twisted multifilaments will be required to reduce control power for sizable dynamic loads, such as those due to unbalance.

Brown, G. V.↗

Heterogeneous Superconducting Low-Noise Sensing Coils

A heterogeneous material construction has been devised for sensing coils of superconducting quantum interference device (SQUID) magnetometers that are subject to a combination of requirements peculiar to some advanced applications, notably including low-field magnetic resonance imaging for medical diagnosis. The requirements in question are the following: The sensing coils must be large enough (in some cases having dimensions of as much as tens of centimeters) to afford adequate sensitivity; The sensing coils must be made electrically superconductive to eliminate Johnson noise (thermally induced noise proportional to electrical resistance); and Although the sensing coils must be cooled to below their superconducting- transition temperatures with sufficient cooling power to overcome moderate ambient radiative heat leakage, they must not be immersed in cryogenic liquid baths. For a given superconducting sensing coil, this combination of requirements can be satisfied by providing a sufficiently thermally conductive link between the coil and a cold source. However, the superconducting coil material is not suitable as such a link because electrically superconductive materials are typically poor thermal conductors. The heterogeneous material construction makes it possible to solve both the electrical- and thermal-conductivity problems. The basic idea is to construct the coil as a skeleton made of a highly thermally conductive material (typically, annealed copper), then coat the skeleton with an electrically superconductive alloy (typically, a lead-tin solder) [see figure]. In operation, the copper skeleton provides the required thermally conductive connection to the cold source, while the electrically superconductive coating material shields against Johnson noise that originates in the copper skeleton.

Hahn, Inseob↗

Design and Construction of Test Coils for the MICE Coupling Solenoid Magnet

The superconducting coupling solenoid to be applied in the Muon Ionization Cooling Experiment (MICE) is made from copper matrix Nb-Ti conductors with inner radius of 750 mm, length of 285 mm and thickness of 102.5 mm at room temperature. The magnetic field up to 2.6 T at the magnet centerline is to keep the muons within the MICE RF cavities. Its self inductance is around 592 H and its magnet stored energy is about 13 MJ at a full current of 210 A for the worst operation case of the MICE channel. The stress induced inside the coil during cool down and charging is relatively high. Two test coils are to build and test in order to validate the design method and develop the fabrication technique required for the coupling coil winding, one is 350 mm inner diameter and full length same as the coupling coil, and the other is one-quarter length and 1.5 m diameter. The 1.5 m diameter coil will be charged to strain conditions that are greater than would be encountered in the coupling coil. This paper presents detailed design of the test coils as well as developed winding skills. The analyses on stress in coil assemblies, AC loss, and quench process are carried out.

42 ENGINEERING↗