Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coefficient of performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Flow Boiling in Microgap Coolers - Suborbital Flight Results

Flow Boiling in Microgap Coolers (FBMC) is a thermal management technique that provides embedded, on-site heat removal for power dense electronic components and systems. The dielectric coolant undergoes liquid-to-vapor phase change as it passes through channels integrated within or between devices. By facilitating direct contact between the coolant and heat-generating devices and relying on phase change, the system provides tight temperature control, hot spot mitigation, very high heat transfer coefficients, and low pumping power. Ground tests demonstrated removal of high heat fluxes (up to 500 kW/m2), very high coefficients of performance (up to 40 W of heat transferred per W of pumping power), and consistent performance across five evaporator orientations under the appropriate conditions. As a follow-on study and to better assess the role of gravity on such two-phase systems, the FBMC payload was developed and flown twice aboard the Blue Origin New Shepard space vehicle in January and May 2019. Each flight exposed the payload to weightlessness (150 seconds below 0.01 g) and shorter periods of high-g during ascent (up to 3 g) and descent (up to 5 g). The flow boiling performance was consistent independent of the acceleration levels, which provides confidence that such systems will provide consistent performance when tested on the ground, orbiting or traveling through weightlessness, and operating on the surface of the Moon, Mars, and other planetary bodies. Details of the flight results, payload development, flight environment, and planned future testing will be presented.

Flow boiling↗

Review of Vapor Compression Refrigeration in Microgravity Environments

Using a vapor compression cycle for cooling in microgravity environments was already suggested in the 1970s to leverage the high coefficient of performance. Since then, only a few systems have operated in microgravity with scarce documentation of these flights. The lack of measured data and detailed documentation makes identifying the necessary next steps difficult for researchers entering the field of refrigeration in space. This paper provides a review of available literature for vapor compression systems flown in microgravity by outlining the history of vapor compression devices in space and presenting performance data. Moreover, gaps in the literature are highlighted and open questions are posed based on the reviewed material. Next steps of research are suggested to support and ultimately achieve reliable vapor compression refrigeration in space. Calculating equivalent masses for a fair comparison of different microgravity cooling technologies is proposed by capturing both energy consumption and used volume.

Vapor compression↗

We Just Want to Pump…You Up! Forecasting Grid-Connected Heat Pump Water Heater Energy Savings and Load Shifting Potential for the Southeast U.S.

Heat pump water heaters (HPWH) can achieve energy savings of 60-70% compared to conventional electric-resistance water heaters. However, even with a favorable simple payback period within the typical product lifetime, HPWHs make up only 1% of all electric water heaters sold in the residential sector. Market adoption is challenged, in part, by the lack of effective energy efficiency programs in the U.S. region with the greatest amount of residential electric water heaters. The recent integration of connected functionality into HPWHs offers the capability to shift load without undue negative impact on customers. This capability can provide value to utilities with peak load constraints, motivating them to promote HPWHs for the first time. This paper will present a methodology to forecast connected HPWH energy use and extrapolate load shifting potential for the Southeast U.S. region. The methodology leverages data from a robust connected HPWH field study conducted in the Pacific Northwest. A coefficient of performance (COP) relationship for HPWHs was developed using ambient and inlet water temperature data to forecast HPWH performance on a month-by-month basis. Using the forecasted COP, HPWH operating hours were calculated for meeting load, which serve as the proxy to extrapolate load shifting potential from the Pacific Northwest to the Southeast. As a use case, analytical results are presented for a specific utility. This methodology, in combination with market analysis, facilitates the development of customized energy savings and load shifting forecasts to understand the potential impacts of launching connected HPWH programs in specific utility service territories.

heat pump water heater, energy savings, load shift↗

Optimization of Refrigerant Compositions for Low-GWP Refrigerant Mixtures Using Segment-by-segment Heat Exchanger and Detailed System Models

The recently introduced hydrofluoroolefin (HFO) refrigerants, including R1234yf and R1234ze(E), have significantly lower global warming potentials (GWPs) than traditional hydrofluorocarbon (HFC) refrigerants like R410A. However, prior tests show that direct drop-in of pure R1234yf or R1234ze(E) into equipment designed for R410A results in a decrease in heat exchanger capacity and the system coefficient of performance. The primary reason is the lower in-tube heat transfer performance of R1234yf and R1234ze(E) compared with that of R410A. To address this issue, previous studies have mixed the mildly flammable HFC R32 with HFOs to improve system performance, with HFC R125 also added to suppress flammability. Previous studies selected compositions based on simple cycle analyses and did not consider modifications of the heat exchanger circuitry configuration to adapt to the new refrigerants. This study presents a novel multi-objective optimization approach to design a refrigerant composition that maximizes energy efficiency within flammability and GWP limits. The approach in this work simultaneously optimizes mixture composition and heat exchanger circuitry configuration. A case study on a rooftop unit indicates that, compared with mixture-only optimization, simultaneous optimization of mixture and heat exchanger circuitry yields a 5.9% improvement in cycle efficiency and a 48.6% reduction in refrigerant flammability with a GWP of 268. Circuitry optimization using refrigerants with different temperature glides shows that the larger the temperature glide is, the larger EER improvement is obtained. The results show that zeotropic blends with a large temperature glide are more sensitive to the refrigerant circuitry than pure refrigerants and may suffer significant performance degradation with subpar heat exchanger circuitry design. The proposed optimization approach is generally applicable to mixtures with any number of components. Using this approach to design a HVAC system can yield higher system efficiency within flammability and GWP constraints.

Li, Zhenning↗

Electrocaloric cooling with electrostatic actuation

A solid-state heat transporting device including a heat transporting element whose uniformity of contact with one or multiple surfaces is controllable so that various amounts of heat may be transported to and from the one or multiple surfaces. The heat transporting element uses the electrocaloric effect to absorb and release the heat and the uniformity of contact is controlled using an electrostatic effect which may change the shape of the heat transporting element. In one embodiment, the heat transporting element is an electrostatically actuated P(VDF-TrFE-CFE) polymer stack achieving a high specific cooling power of 2.8 W/g and a COP of 13 (the highest reported coefficient of performance to date) when used as a cooling device.

42 ENGINEERING↗

Development and Testing of an Advanced Cascaded Thermoelectric Residential Heat Pump

Electricity-driven heat pumps using vapor compression cycle are an energy-efficient solution to replace fossil fuel burning and reduce greenhouse gas emissions for space heating in residential buildings. However, heating capacity and Coefficient of Performance (COP) of heat pumps degrade significantly with increasing temperature difference between ambient and indoor environments. Residents and building owners are hence reluctant to fully embrace electric heat pumps. The use of conventional all-electric heat pumps also causes concern for electric utilities due to an increased winter peak demand arising from the use of supplemental electric resistance heaters. Our research is an attempt to alleviate these concerns by designing and laboratory testing a thermoelectric (TE) heat pump cascaded with a vapor compression cycle to enhance heating capacity and COP. TE modules increase the subcooling in the refrigerant liquid of the vapor compression cycle to enlarge the evaporating capacity and works at an efficiency greater than a conventional electric resistance strip. This results in a simple, affordable, efficient and highly controllable solution to adequately meet space heating needs in dwellings. The laboratory testing of the 3-stage cascaded TE heat pump performed in this research has exhibited a higher heating capacity by above 15%, while maintaining a heating COP of 2.0-3.6 in the ambient temperature range of -18˚C to 8˚C (0˚F to 47 ˚F), which represents more than 60% of winter temperatures observed in US. If successfully commercialized, this technology can advance space-heating electrification by overcoming consumer cost barrier of heat pumps.

Shen, Bo↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air Source Heat Pumps: Preprint

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climates. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in the northwest United States and one in a Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five seconds, to calculate the heat pump’s capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)↗

Scale model testing of drogues for free drifting buoys

Instrumented model drogue tests were conducted in a ship model towing tank. The purpose of the tests was to observe and measure deployment and drag characteristics of such shapes as parachutes, crossed vanes, and window shades which may be employed in conjunction with free drifting buoys. Both Froude and Reynolds scaling laws were applied while scaling to full scale relative velocities of from 0 to 0.2 knots. A weighted window shade drogue is recommended because of its performance, high drag coefficient, simplicity, and low cost. Detailed theoretical performance curves are presented for parachutes, crossed vanes, and window shade drogues. Theoretical estimates of depth locking accuracy and buoy-induced dynamic loads pertinent to window shade drogues are presented as a design aid. An example of a window shade drogue design is presented.

Vachon, W. A.↗

Advanced Parametric Lobe Mixer Concepts for Internally Mixed Nozzles

A continuation of efforts to optimize a dual-stream lobe mixer for supersonic commercial flight are detailed, adding scarfing and scalloping features to a baseline lobe mixer previously optimized within a baseline parametric space. These "advanced features" are parameterized by four quantities: scarfing angle 𝜁, scallop height ℎ 𝑠 , scallop depth 𝑑 𝑠 , and scallop conic focal parameter 𝜌 𝑠 . Two baseline mixers, one parallel and one vortical, form the basis for an eighteen-case study to investigate the effects of each parameter in single-axis fashion. Aerodynamic performance is evaluated through velocity coefficient 𝐶 𝑉 . Moderate performance increases are seen with increasing scallop height and depth on the parallel mixer, and with increasing scarfing angle on the vortical mixer. Flowfield analysis is presented through visualization of axial and cross-stream vorticity development through the duct, as well as density variation. A correlation between axial vorticity and density variation decay was found, with earlier introduction of axial vorticity found to result in improved aerodynamic performance and potential noise suppression.

Lobe Mixer↗

Nonlinearity Effects of Lateral Density Diffusion Coefficient on Gain-Guided VCSEL Performance

Electron and hole diffusions in the plane of semiconductor quantum wells play an important part in the static and dynamic operations of semiconductor lasers. In this paper, we apply a hydrodynamic model developed from the semiconductor Bloch equations to numerically study the effects of nonlinearity in the diffusion coefficient on single mode operation and direct modulation of a gain-guided InGaAs/GaAs multiple quantum well laser, operating not too far from threshold. We found that a small diffusion coefficient is advantageous for lowering the threshold current and increasing the modulation bandwidth. Most importantly, the effects of nonlinearity in the coefficient can be approximately reproduced by replacing the coefficient with an effective constant diffusion coefficient, which corresponds roughly to the half height density of the density distribution.

Li, Jian-Zhong↗

Evaluation of the Tau-Omega Model over a Dense Corn Canopy at P- and L-band

As an emerging technique, P-band (0.3-1GHz) may improve soil moisture remote sensing compared to L-band (1.4 GHz) SMOS (Soil Moisture and Ocean Salinity) and SMAP (Soil Moisture Active Passive) missions, because of its greater moisture retrieval depth resulting from its longer wavelength. Consequently, a number of tower-based experiments were undertaken in Victoria, Australia, to understand and quantify potential improvements. The study reported here has extended the evaluation of the tau-omega model to a scenario with a dense corn canopy whose vegetation water content reached ~20 kg/m 2 , and compared the soil moisture retrieval performance at P- and L-band. Based on the locally calibrated parameters, the results from both the SCA (Single Channel Algorithm) and DCA (Dual Channel Algorithm) approaches presented a clear reduction in vegetation impact at P-band compared to L-band. While the root-mean-square error (RMSE) for P-band did not achieve the 0.04-m 3 /m 3 target accuracy of SMOS and SMAP, i.e., 0.054 m 3 /m 3 for the SCA and 0.074 m 3 /m 3 for the DCA, this performance can be regarded as acceptable considering the extremely high vegetation water content. In comparison, the RMSEs at L-band were larger than 0.1 m 3 /m 3 for both the SCA and the DCA approaches. Additionally, DCA performed better in correlation coefficient and unbiased RMSE, while SCA performed better in RMSE at P-band due to the larger bias when using DCA. Moreover, the calibrated vegetation parameters at P-band were found to apply to broader conditions than those at L-band, likely due to the reduced vegetation impact.

P-band↗

Data-driven modeling of dynamic occupant thermostat override behavior for demand response applications

Buildings consume nearly 40% of global energy and produce similar emissions. Whiletechnological advances address efficiency, occupant behavior causes energy use variations up to 300% between identical buildings. This gap between predicted and actual building performance impacts building design, operations, and grid demand management programs. Through analyses of smart thermostat data from 1,400 single-occupant homes, the researchdemonstrates that occupants respond to 8°F thermostat setpoint changes within a median of 15 minutes, while 2°F changes trigger responses within a median of 30 minutes. This highlights an understudied temporal relationship between thermostat setbacks and response time of occupant behaviors. Models of such behavior dynamics are required to incorporate occupant impacts into building performance simulation. A key contribution of this dissertation is the Thermal Frustration Theory (TFT), which positsthat thermal discomfort driven behaviors are caused by the time-accumulation of discomfort, not simply a temperature deviation threshold or a delay from an initiating event. Using a dataset of 634 thermostats, each with 25+ manual setpoint changes, a comparative analysis of TFT and comfort zone and a delayed response theories demonstrated that personalized TFT models better predict when manual setpoint change occur. This was measured by the area under the curve statistical measure (AUC); all three models perform similarly by a Matthews Correlation Coefficient measure. Higher AUC performance is especially important for modeling occupant behavior in demand response programs where false negatives of rare occupant interactions could adversely affect grid stability. EnergyPlus based simulations were conducted with TFT-derived occupant models, demonstrating the ability to identify parameters of known TFT models from only data observable with smart thermostats, even under the presence of noise from routine overrides. Overall, the dissertation highlights that thermostat interactions are neither static,instantaneous, nor driven solely by the environment. Instead, temporal accumulation of discomfort and routine-based behavior play important roles. The methodology and results offer a pathway towards more accurate modeling of human-building interactions for policy assessment, building design, and demand response programs.

Sharma, Kunind [Northeastern University] (ORCID:00↗

Effects of Heat Transfer Coefficient Variation on Nuclear Thermal Propulsion Engine Performance

A physics-based Nuclear Thermal Propulsion (NTP) Testing Reference Design (TRD) power balance model was coded in Simulink to investigate engine performance for various design and parameter modifications. Since the primary mode of heat transfer in NTP engines is convective, the convective heat transfer coefficient (HTC) is a key parameter that requires accurate representation. The industry standard Westinghouse correlation has an uncertainty of ±20% which was investigated in this study. The results showed that a 20% decrease in the HTC led to a 4.14% increase in maximum fuel temperature while a 20% decrease in the HTC led to a 1.81% decrease in maximum fuel temperature suggesting that narrowing the uncertainty of this correlation through experimental work would be a critical step in the development of NTP engines. Furthermore, a maximum fuel temperature relationship with specific impulse was developed for the TRD engine which showed potential engine operation between specific impulse values of 715 and 900 seconds with minimal changes to the engine design. This graph could be useful for high level vehicle performance estimations for fuel types with different maximum operating temperatures.

Heat Transfer Coefficient↗

Internal performance characteristics of thrust-vectored axisymmetric ejector nozzles

A series of thrust-vectored axisymmetric ejector nozzles were designed and experimentally tested for internal performance and pumping characteristics at the Langley research center. This study indicated that discontinuities in the performance occurred at low primary nozzle pressure ratios and that these discontinuities were mitigated by decreasing expansion area ratio. The addition of secondary flow increased the performance of the nozzles. The mid-to-high range of secondary flow provided the most overall improvements, and the greatest improvements were seen for the largest ejector area ratio. Thrust vectoring the ejector nozzles caused a reduction in performance and discharge coefficient. With or without secondary flow, the vectored ejector nozzles produced thrust vector angles that were equivalent to or greater than the geometric turning angle. With or without secondary flow, spacing ratio (ejector passage symmetry) had little effect on performance (gross thrust ratio), discharge coefficient, or thrust vector angle. For the unvectored ejectors, a small amount of secondary flow was sufficient to reduce the pressure levels on the shroud to provide cooling, but for the vectored ejector nozzles, a larger amount of secondary air was required to reduce the pressure levels to provide cooling.

Lamb, Milton↗

Comparison of Thermal Coefficients for Two Microwave Detectors

Laboratory measurements were performed to compare the thermal coefficients of two microwave detectors that might be used for direct detection in L-band radiometers. In particular it was desired to compare the performance of a new-technology flash ADC (analog-to-digital converter) against that of an older-technology diode detector in series with a VFC (voltage-to-frequency converter). The outputs of two state-of-the-art detectors were recorded as a constant 1.414-GHz signal was input and the physical temperatures of the detectors were varied over a range of 10 C. As a further experiment, each detector was tested with a noise diode source and with a sine wave synthesizer source. Thermal coefficients were computed in terms of W/C and in terms of ppt/C at nominal operating temperatures reasonable for the individual devices. Finally, thermal coefficients were calculated in K/C to indicate the change in brightness temperature seen by a theoretical sea surface salinity radiometer employing each detector. The K/C for the flash ADC was determined to be about 2.8 times that of the diode/VFC. Different reactions of the ADC to a noise input and a sine wave input indicated that ADC tests for radiometric purposes, such as this one, should be performed using a noise input.

Mackenzie, Anne I.↗