Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Characteristic Curves”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Pleural homocysteine for malignant pleural effusion: A prospective and double‐blind diagnostic test accuracy study

Abstract Objective To assess the accuracy of pleural fluid homocysteine for discriminating malignant pleural effusion (MPE) and benign pleural effusion (BPE). Methods A total of 194 patients from two cohorts (Hohhot and Changshu) with undiagnosed pleural effusion were prospectively enrolled. Their pleural homocysteine was measured, and its diagnostic accuracy and net benefit for MPE were analyzed by receiver operating characteristic (ROC) curve analysis and decision curve analysis, respectively. Results In the Hohhot cohort ( n = 136) and the Changshu cohort ( n = 58), MPE patients had significantly higher homocysteine levels than BPE patients. The areas under the ROC curves of homocysteine for the diagnosis of MPE were 0.61 ( p = 0.027) and 0.59 ( p = 0.247), respectively. The decision curves of homocysteine were close to the reference line in both the Hohhot cohort and the Changshu cohort. Conclusion The diagnostic accuracy of pleural fluid homocysteine for MPE was low.

Cao, Xi‐Shan↗

Performance Evaluation and Optimal Design Analysis of Continuous-Operation Solar-Driven Cooling Absorption Systems With Thermal Energy Storage

A solar absorption cooling system consisting of a flat plate collector, thermal energy storage tank, and absorption chiller is analyzed in this work. A dimensionless model is developed from the energy balance on each component and the chiller's characteristic performance curves. The model is used to determine the interaction and influence of different parameters such as tank size, solar collector area, chiller size, cooling load, cooling temperature, heat loss, and mass flow rates on the performance. From the analysis, smaller solar collector areas are required for lower cooling loads and smaller tank volumes. A specific cooling load of 1 x 10^-5 will require a specific solar collector area between two and six times larger, depending on the initial tank temperature, than the area required for a baseline system that considers typical commercial design and operation parameters. A similar behavior was observed for the specific tank volume. For the baseline system, the minimum specific area of the collector of 9.57 is achieved for an initial tank temperature of 1.19. For a cooling load of 1 x 10^-5, the optimum initial tank temperature will be 1.11 that results in a minimum specific solar collector area of 25.26. A specific tank volume of 4 x 10^-4 will also have an optimum initial tank temperature of 1.11 that minimizes the specific solar collector area to a value of 28.18. The approach and analysis in this work can be used to determine design parameters for solar absorption cooling systems based on a proper relation among system's dimensions to achieve optimum operation.

cooling load↗

Optimal band selection for target detection with a LWIR multispectral imager

Multispectral imaging can offer many benefits in cost, complexity, resolution, size, weight, and power, relative to hyperspectral imaging. When designing a multispectral system, spectral bandpasses can be selected using optimization algorithms configured to maximally separate target detection scores between target and background regions. A hyperspectral image (HSI) can serve as the source of data from which band groupings can be tested for optimality. The output of an adaptive cosine estimator target detection algorithm is used in an objective function. Three optimization algorithms are compared: particle swarm, dual annealing, and differential evolution. A global optimum is also found using a brute force approach on the Livermore Computing Syrah supercomputer. Three materials are investigated: calcite, gypsum, and limestone. This is done for 3-, 4-, and 5-band systems. The data originate from a longwave infrared HSI of a material display board. The optimization algorithms were run 30 times for every scenario. Performance statistics (maximum, minimum, mean, standard deviation, and median) based on the separation values are given. Additional characterization was performed using receiver operator characteristic (ROC) curves and the area under the ROC curve. While good performance was obtained for the three optimization algorithms, the dual annealing algorithm produced the highest and most consistent detection separation scores on average.

47 OTHER INSTRUMENTATION↗

Accuracy of Fukuoka and American Gastroenterological Association Guidelines for Predicting Advanced Neoplasia in Pancreatic Cyst Neoplasm: A Meta-Analysis

Background: A differential diagnosis of advanced pancreatic cystic neoplasms (PCNs) is critical to determine optimal treatment. The Fukuoka and American Gastroenterological Association (AGA) guidelines are the most widely accepted criteria for the management of PCNs. Objective: This study aimed to evaluate the diagnostic value of these guidelines in predicting advanced neoplasia (AN). Methods: A comprehensive electronic search of the PubMed, EMBASE, Web of Science, Cochrane Library, and Scopus databases was conducted to identify all relevant studies evaluating the Fukuoka and AGA guidelines in surgically resected and histologically confirmed PCNs. Pooled sensitivity, specificity, and diagnostic odds ratios (DORs) were calculated as compound measures of diagnostic accuracy using the random-effects model. Summary of receiver operating characteristic (SROC) curves and the area under the curve (AUC) were also performed. Results: A total of 21 studies with 3723 patients were included in this meta-analysis. Of these studies, 15, 4, and 2 evaluated the Fukuoka guidelines, the AGA guidelines, and both guidelines, respectively. For AN prediction, the Fukuoka guidelines had a pooled sensitivity of 0.67 (95% confidence interval [CI] 0.64–0.70), pooled specificity of 0.64 (95% CI 0.62–0.66), and pooled DOR of 6.28 (95% CI 4.38–9.01), with an AUC of the SROC of 0.78. AGA guidelines showed a pooled sensitivity of 0.59 (95% CI 0.52–0.65), pooled specificity of 0.77 (95% CI 0.74–0.80), and pooled DOR of 5.84 (95% CI 2.60–13.15), with an AUC of 0.79 (95% CI 0.70–0.88). Conclusion: When used alone, the Fukuoka and AGA guidelines showed similar but unsatisfactory diagnostic accuracy in the risk stratification of malignant potential of PCN. Thus, we recommend that they be applied only as a broad framework in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Establishment of a reverse transcription real-time quantitative PCR method for Getah virus detection and its application for epidemiological investigation in Shandong, China

Getah virus (GETV) is a mosquito-borne, single-stranded, positive-sense RNA virus belonging to the genus Alphavirus of the family Togaviridae . Natural infections of GETV have been identified in a variety of vertebrate species, with pathogenicity mainly in swine, horses, bovines, and foxes. The increasing spectrum of infection and the characteristic causing abortions in pregnant animals pose a serious threat to public health and the livestock economy. Therefore, there is an urgent need to establish a method that can be used for epidemiological investigation in multiple animals. In this study, a real-time reverse transcription fluorescent quantitative PCR (RT-qPCR) method combined with plaque assay was established for GETV with specific primers designed for the highly conserved region of GETV Nsp1 gene. The results showed that after optimizing the condition of RT-qPCR reaction, the minimum detection limit of the assay established in this study was 7.73 PFU/mL, and there was a good linear relationship between viral load and Cq value with a correlation coefficient ( R 2 ) of 0.998. Moreover, the method has good specificity, sensitivity, and repeatability. The established RT-qPCR is 100-fold more sensitive than the conventional RT-PCR. The best cutoff value for the method was determined to be 37.59 by receiver operating characteristic (ROC) curve analysis. The area under the curve (AUC) was 0.956. Meanwhile, we collected 2,847 serum specimens from swine, horses, bovines, sheep, and 17,080 mosquito specimens in Shandong Province in 2022. The positive detection rates by RT-qPCR were 1%, 1%, 0.2%, 0%, and 3%, respectively. In conclusion, the method was used for epidemiological investigation, which has extensive application prospects.

Cao, Xinyu↗

Comparison of Hafnium Dioxide and Zirconium Dioxide Grown by Plasma-Enhanced Atomic Layer Deposition for the Application of Electronic Materials

We report the growth of nanoscale hafnium dioxide (HfO 2 ) and zirconium dioxide (ZrO 2 ) thin films using remote plasma-enhanced atomic layer deposition (PE-ALD), and the fabrication of complementary metal-oxide semiconductor (CMOS) integrated circuits using the HfO 2 and ZrO 2 thin films as the gate oxide. Tetrakis (dimethylamino) hafnium (Hf[N(CH 3 ) 2 ] 4 ) and tetrakis (dimethylamino) zirconium (IV) (Zr[N(CH 3 ) 2 ] 4 ) were used as the precursors, while O 2 gas was used as the reactive gas. The PE-ALD-grown HfO 2 and ZrO 2 thin films were analyzed using X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD), and high-resolution transmission electron microscopy (HRTEM). The XPS measurements show that the ZrO 2 film has the atomic concentrations of 34% Zr, 2% C, and 64% O while the HfO 2 film has the atomic concentrations of 29% Hf, 11% C, and 60% O. The HRTEM and XRD measurements show both HfO 2 and ZrO 2 films have polycrystalline structures. n-channel and p-channel metal-oxide semiconductor field-effect transistors (nFETs and pFETs), CMOS inverters, and CMOS ring oscillators were fabricated to test the quality of the HfO 2 and ZrO 2 thin films as the gate oxide. Current-voltage (IV) curves, transfer characteristics, and oscillation waveforms were measured from the fabricated transistors, inverters, and oscillators, respectively. The experimental results measured from the HfO 2 and ZrO 2 thin films were compared.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

IoT Intrusion Detection Taxonomy, Reference Architecture, and Analyses

This paper surveys the deep learning (DL) approaches for intrusion-detection systems (IDSs) in Internet of Things (IoT) and the associated datasets toward identifying gaps, weaknesses, and a neutral reference architecture. A comparative study of IDSs is provided, with a review of anomaly-based IDSs on DL approaches, which include supervised, unsupervised, and hybrid methods. All techniques in these three categories have essentially been used in IoT environments. To date, only a few have been used in the anomaly-based IDS for IoT. For each of these anomaly-based IDSs, the implementation of the four categories of feature(s) extraction, classification, prediction, and regression were evaluated. We studied important performance metrics and benchmark detection rates, including the requisite efficiency of the various methods. Four machine learning algorithms were evaluated for classification purposes: Logistic Regression (LR), Support Vector Machine (SVM), Decision Tree (DT), and an Artificial Neural Network (ANN). Therefore, we compared each via the Receiver Operating Characteristic (ROC) curve. The study model exhibits promising outcomes for all classes of attacks. The scope of our analysis examines attacks targeting the IoT ecosystem using empirically based, simulation-generated datasets (namely the Bot-IoT and the IoTID20 datasets).

97 MATHEMATICS AND COMPUTING↗

Cryogenic gel flow viscometer

Coiled section of tubing measures viscous properties of gelled cryogenic propellants under conditions closely resembling flow in rocket engine systems. Characteristic flow curve provides data necessary for the design of prototype hardware systems using the liquid or gel of interest.

Globus, R. H.↗

Solar wind photoplate study

An ion sensitive emulsion detection system has been considered for use in a cycloidal focusing mass spectrometer to measure the various atomic species which comprise the solar plasma. The responses of Ilford Q2 and Kodak SC7 emulsions were measured with N(+) ions at 6 keV to 10 keV, He(++) ions at 750 eV to 2500 eV, and H(+) ions at 550 eV to 1400 eV. These ions have the approximate range of velocities (about 300-500 km/sec) encountered in the solar wind. The work was carried out on a specially prepared magnetic sector mass analyzer. Characteristic response curves were generated, each one utilizing approximately 50 data points at three or more current densities. In addition to the ion response, measurements of the response of these emulsions to a photon flux simulating the visible portion of the solar spectrum were made. The results obtained will be presented in detail and interpreted in relation to other data available for these emulsions.

Scott, B. W.↗

Soil moisture from temperature measurements at the Earth's surface, update

Soil moisture budgets at the Earth's surface were investigated based on soil and atmospheric temperature variations. A number of data sets were plotted and statistically analyzed in order to accentuate the existence and the characteristics of mesoscale soil temperature extrema variations and their relations to other parameters. The correlations between diurnal temperature extrema for air and soil in drought and non-drought periods appear to follow different characteristic patterns, allowing an inference of soil moisture content from temperature data. The recovery of temperature extrema after a precipitation event also follows a characteristic power curve rise between two limiting values which is an indicator of evaporation rates. If these indicators are applied universally to regional temperature data, soil moisture content or drought conditions can be inferred directly from temperature measurements.

Welker, J. E.↗

Multiple incidence angle SIR-B experiment over Argentina

The Shuttle Imaging Radar (SIR-B), the second synthetic aperture radar (SAR) to fly aboard a shuttle, was launched on October 5, 1984. One of the primary goals of the SIR-B experiment was to use multiple incidence angle radar images to distinguish different terrain types through the use of their characteristic backscatter curves. This goal was accomplished in several locations including the Chubut Province of southern Argentina. Four descending image acquisitions were collected providing a multiple incidence angle image set. The data were first used to assess stereo-radargrammetric techniques. A digital elevation model was produced using the optimum pair of multiple incidence angle images. This model was then used to determine the local incidence angle of each picture element to generate curves of relative brightness vs. incidence angle. Secondary image products were also generated using the multi-angle data. The results of this work indicate that: (1) various forest species and various structures of a single species may be discriminated using multiple incidence angle radar imagery, and (2) it is essential to consider the variation in backscatter due to a variable incidence angle when analyzing and comparing data collected at varying frequencies and polarizations.

Cimino, Jobea↗

Effect of joint damping and joint nonlinearity on the dynamics of space structures

Analyses of the effect of linear joint characteristics on the vibrations of a free-free, three-joint beam model show that increasing joint damping increases resonant frequencies and increases modal damping but only to the point where the joint gets 'locked up' by damping. This behavior is different from that predicted by modeling joint damping as proportional damping. Nonlinear analyses of the three-joint model with cubic springs at the joints show all the classical single DOF nonlinear response behavior at each resonance of the multiple DOF system: nondoubling of response for a doubling of forcing amplitude, multiple solutions, jump behavior, and resonant frequency shifts. These properties can be concisely quantified by characteristic backbone curves, which show the locus of resonant peaks for increasing forcing amplitude.

Bowden, Mary↗

Crystal Oscillators Operate Beyond Rated Frequencies

Amplifiers with single-pole frequency responses used in their "roll-off" regions. Class of crystal oscillators based on use of negative-voltage-gain amplifiers at frequencies well into "roll-off" frequency regions of their gain-versus-frequency curves. Defining characteristic helps keep costs of oscillators low; not necessary to use more expensive amplifiers that have flat frequency responses out to desired operating frequencies. Enables amplifier to produce phase shift necessary for oscillation, reducing cost further by eliminating need for some of passive components in oscillators of more conventional design.

Kleinberg, Leonard L.↗

Performance Evaluation of Evasion Maneuvers for Parallel Approach Collision Avoidance

Current plans for independent instrument approaches to closely spaced parallel runways call for an automated pilot alerting system to ensure separation of aircraft in the case of a "blunder," or unexpected deviation from the a normal approach path. Resolution advisories by this system would require the pilot of an endangered aircraft to perform a trained evasion maneuver. The potential performance of two evasion maneuvers, referred to as the "turn-climb" and "climb-only," was estimated using an experimental NASA alerting logic (AILS) and a computer simulation of relative trajectory scenarios between two aircraft. One aircraft was equipped with the NASA alerting system, and maneuvered accordingly. Observation of the rates of different types of alerting failure allowed judgement of evasion maneuver performance. System Operating Characteristic (SOC) curves were used to assess the benefit of alerting with each maneuver.

Winder, Lee F.↗

Estimates of volumetric bone density from projectional measurements improve the discriminatory capability of dual X-ray absorptiometry

To determine whether estimates of volumetric bone density from projectional scans of the lumbar spine have weaker associations with height and weight and stronger associations with prevalent vertebral fractures than standard projectional bone mineral density (BMD) and bone mineral content (BMC), we obtained posteroanterior (PA) dual X-ray absorptiometry (DXA), lateral supine DXA (Hologic QDR 2000), and quantitative computed tomography (QCT, GE 9800 scanner) in 260 postmenopausal women enrolled in two trials of treatment for osteoporosis. In 223 women, all vertebral levels, i.e., L2-L4 in the DXA scan and L1-L3 in the QCT scan, could be evaluated. Fifty-five women were diagnosed as having at least one mild fracture (age 67.9 +/- 6.5 years) and 168 women did not have any fractures (age 62.3 +/- 6.9 years). We derived three estimates of "volumetric bone density" from PA DXA (BMAD, BMAD*, and BMD*) and three from paired PA and lateral DXA (WA BMD, WA BMDHol, and eVBMD). While PA BMC and PA BMD were significantly correlated with height (r = 0.49 and r = 0.28) or weight (r = 0.38 and r = 0.37), QCT and the volumetric bone density estimates from paired PA and lateral scans were not (r = -0.083 to r = 0.050). BMAD, BMAD*, and BMD* correlated with weight but not height. The associations with vertebral fracture were stronger for QCT (odds ratio [QR] = 3.17; 95% confidence interval [CI] = 1.90-5.27), eVBMD (OR = 2.87; CI 1.80-4.57), WA BMDHol (OR = 2.86; CI 1.80-4.55) and WA-BMD (OR = 2.77; CI 1.75-4.39) than for BMAD*/BMD* (OR = 2.03; CI 1.32-3.12), BMAD (OR = 1.68; CI 1.14-2.48), lateral BMD (OR = 1.88; CI 1.28-2.77), standard PA BMD (OR = 1.47; CI 1.02-2.13) or PA BMC (OR = 1.22; CI 0.86-1.74). The areas under the receiver operating characteristic (ROC) curves for QCT and all estimates of volumetric BMD were significantly higher compared with standard PA BMD and PA BMC. We conclude that, like QCT, estimates of volumetric bone density from paired PA and lateral scans are unaffected by height and weight and are more strongly associated with vertebral fracture than standard PA BMD or BMC, or estimates of volumetric density that are solely based on PA DXA scans.

Non-NASA Center↗

Investigation of Liner Characteristics in the NASA Langley Curved Duct Test Rig

The Curved Duct Test Rig (CDTR), which is designed to investigate propagation of sound in a duct with flow, has been developed at NASA Langley Research Center. The duct incorporates an adaptive control system to generate a tone in the duct at a specific frequency with a target Sound Pressure Level and a target mode shape. The size of the duct, the ability to isolate higher order modes, and the ability to modify the duct configuration make this rig unique among experimental duct acoustics facilities. An experiment is described in which the facility performance is evaluated by measuring the sound attenuation by a sample duct liner. The liner sample comprises one wall of the liner test section. Sound in tones from 500 to 2400 Hz, with modes that are parallel to the liner surface of order 0 to 5, and that are normal to the liner surface of order 0 to 2, can be generated incident on the liner test section. Tests are performed in which sound is generated without axial flow in the duct and with flow at a Mach number of 0.275. The attenuation of the liner is determined by comparing the sound power in a hard wall section downstream of the liner test section to the sound power in a hard wall section upstream of the liner test section. These experimentally determined attenuations are compared to numerically determined attenuations calculated by means of a finite element analysis code. The code incorporates liner impedance values educed from measured data from the NASA Langley Grazing Incidence Tube, a test rig that is used for investigating liner performance with flow and with (0,0) mode incident grazing. The analytical and experimental results compare favorably, indicating the validity of the finite element method and demonstrating that finite element prediction tools can be used together with experiment to characterize the liner attenuation.

Gerhold, Carl H.↗

Signal Detection Theory Applied to Helicopter Transmission Diagnostic Thresholds

Helicopter Health Usage Monitoring Systems (HUMS) have potential for providing data to support increasing the service life of a dynamic mechanical component in the transmission of a helicopter. Data collected can demonstrate the HUMS condition indicator responds to a specific component fault with appropriate alert limits and minimal false alarms. Defining thresholds for specific faults requires a tradeoff between the sensitivity of the condition indicator (CI) limit to indicate damage and the number of false alarms. A method using Receiver Operating Characteristic (ROC) curves to assess CI performance was demonstrated using CI data collected from accelerometers installed on several UH60 Black Hawk and AH64 Apache helicopters and an AH64 helicopter component test stand. Results of the analysis indicate ROC curves can be used to reliably assess the performance of commercial HUMS condition indicators to detect damaged gears and bearings in a helicopter transmission.

Dempsey, Paula J.↗

Signal Detection Theory Applied to Helicopter Transmission Diagnostic Thresholds

Helicopter Health Usage Monitoring Systems (HUMS) have potential for providing data to support increasing the service life of a dynamic mechanical component in the transmission of a helicopter. Data collected can demonstrate the HUMS condition indicator responds to a specific component fault with appropriate alert limits and minimal false alarms. Defining thresholds for specific faults requires a tradeoff between the sensitivity of the condition indicator (CI) limit to indicate damage and the number of false alarms. A method using Receiver Operating Characteristic (ROC) curves to assess CI performance was demonstrated using CI data collected from accelerometers installed on several UH60 Black Hawk and AH64 Apache helicopters and an AH64 helicopter component test stand. Results of the analysis indicate ROC curves can be used to reliably assess the performance of commercial HUMS condition indicators to detect damaged gears and bearings in a helicopter transmission.

Dempsey, Paula J.↗