Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Change detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Wood template-supported phase change material composites for durable and form-stable thermal energy storage in buildings

Here, to reduce and shift peak energy loads in buildings, phase change materials (PCMs) with high transition enthalpies and transition temperatures near human thermal comfort are desirable for thermal energy storage (TES). Traditional solid/liquid PCMs suffer from leakage during thermal cycling, requiring encapsulation that lowers heat storage capacity. Wood templates (WTs), with porous and hierarchical structures, provide natural encapsulation scaffolds for PCM containment. Polyethylene glycol (PEG) is a compatible PCM with WTs, but when infiltrated alone, ~30 wt% of PEG binds to wood with no detectable phase change, limiting TES efficiency. To address this, we developed a method to (1) improve the form stability of balsa and pine-based composites (BWT + PCMs and PWT + PCMs) and (2) reduce inactive PCM within the composites to ~10 wt%. BWT + PCMs exhibit transition properties upwards of 114.2 J/g at 25.4 degrees C, with no degradation after 1000 thermal cycles, and similar stiffness compared to raw balsa. Meanwhile, PWT + PCMs exhibit 25 % higher storage efficiency with the addition of poly(ethylene glycol) diacrylate compared to solely PEG-infiltrated PWT. PWT + PCM retains 84 % of raw pine's mechanical stiffness, sufficient for light-duty construction. Our shape-stabilized WT + PCM composites enrich the functionality of wood materials as both ideal TES material candidates and light-duty building construction applications.

25 ENERGY STORAGE↗

On the Compatibility of Ground-based and Space-based Data: WASP-96 b, an Example

The study of exoplanetary atmospheres relies on detecting minute changes in the transit depth at different wavelengths. To date, a number of ground- and space-based instruments have been used to obtain transmission spectra of exoplanets in different spectral bands. One common practice is to combine observations from different instruments in order to achieve a broader wavelength coverage. We present here two inconsistent observations of WASP-96 b, one by the Hubble Space Telescope (HST) and the other by the Very Large Telescope (VLT). We present two key findings in our investigation: (1) a strong water signature is detected via the HST WFC3 observations and (2) a notable offset in transit depth (>1100 ppm) can be seen when the ground-based and space-based observations are combined. The discrepancy raises the question of whether observations from different instruments could indeed be combined. We attempt to align the observations by including an additional parameter in our retrieval studies but are unable to definitively ascertain that the aligned observations are indeed compatible. The case of WASP-96 b signals that compatibility of instruments should not be assumed. While wavelength overlaps between instruments can help, it should be noted that combining data sets remains risky business. The difficulty of combining observations also strengthens the need for next-generation instruments that possess broader spectral coverage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model-based image change quantification

A system is provided for identifying and quantizing a change in a scene having objects based on comparison of features representing a target object derived from a first image and a second image that includes the target object. The system segments, based on a scene model of the scene, a second image that includes the target object to identify a second area representing the target object within the second image. The system extracts, from the second image, second features for the target object based on the second area. The system determines a second effectiveness of the second features indicating effectiveness of the second features in representing the target object. The system detects a change based on a difference between first features and the second features factoring in a first effectiveness and the second effectiveness.

Roberts, Randy S.↗

Encryption of Signal Pulses to Replace Tamper-indicating Conduit

In order to verify signal integrity and point of origin for TTL pulse data used in IAEA systems, and to avoid the need for expensive tamper-indicating conduit or electronic techniques, we propose the development of a signal pulse signing and encryption in-line device. In measurement applications in which the data acquisition electronics is separate from the enclosed, sealed detector, tamper-indicating techniques are required to protect raw TTL pulse streams between the detector and the data acquisition module, i.e UMSR. The goal of this proposed project is to design a rad-tolerant transmitter that would mount inside the sealed detector system and a receiver in the sealed electronics cabinet with the data acquisition instrument. This transmitter/receiver pair would digitally sign and encrypt the pulse stream data at the detector then transmit the data to the sealed cabinet where the receiver would decrypt the data and reproduce the original pulse stream. Existing tamper indicating techniques, such as LiveWire’s spread spectrum time domain reflectometry rely on detecting physical changes to the wiring system and can be blind to fast coupling of micro-second wide pulses. Digital signing and encryption techniques such as the Sandia Laboratories Enhanced Data Authentication System (EDAS) are capable of encrypting communications data, i.e. RS-232, but are not capable reproducing a critical time correlated data streams. Recent NA-241 Safeguards Technology supported developments have reduced the need for special conduit to transmit data via Ethernet by incorporating the IAEA RAINSTORM data encryption and authentication protocol, a tamper indicator is still required to protect raw pulse data from detectors to the acquisition electronics. Encrypting pulse data is especially complicated for radiation detection instruments due to the time correlation data analysis that is performed on this data stream. Any corruption in the timing information will produce errors in measurement values.

97 MATHEMATICS AND COMPUTING↗

Detection of astrophysical neutrinos at prospective locations of dark matter detectors

We study the prospects for detection of solar, atmospheric neutrino, and diffuse supernova neutrino background (DSNB) fluxes at future large-scale dark matter detectors through both electron and nuclear recoils. We specifically examine how the detection prospects change for several prospective detector locations [Sanford Underground Research Facility (SURF), SNOlab, Gran Sasso, China Jinping Underground Laboratory (CJPL), and Kamioka] and improve upon the statistical methodologies used in previous studies. Because of its ability to measure lower neutrino energies than other locations, we find that the best prospects for the atmospheric neutrino flux are at the SURF location, while the prospects are weakest at CJPL because it is restricted to higher neutrino energies. On the contrary, the prospects for the DSNB are best at CJPL, due largely to the reduced atmospheric neutrino background at this location. Including full detector resolution and efficiency models, the CNO component of the solar flux is detectable via the electron recoil channel with exposures of ∼ 10 3 ton-yr for all locations. These results highlight the benefits for employing two detector locations, one at high and one at low latitude. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Optical image analysis for graphene layer detection: Enhanced green channel methodology

Graphene, a material of increasing research interest, requires accurate layer identification due to its sensitivity to layer count. Existing methods for graphene layer number identification are either time-consuming or of low accuracy, with high-accuracy methods often requiring expensive processes. This paper aims to address this challenge by proposing a cost-effective and efficient approach. Specifically, the current work highlights only the green channel—one of the three primary color channels (red, green, blue) that make up an optical image—from images of exfoliated graphene flakes for layer count identification. A linear regression is performed between pixel position and substrate green channel value, and this effect is subtracted from the entire optical image to mitigate background effects. By storing the range of green channel values for each type of flake (monolayer, bilayer, or tri-layer) based on a few images, we establish thresholds for identifying different types of layers in a particular setup. Additionally, our methodology allows for flexible threshold tuning using a single reference image, enabling adjustment to changes in detection setup such as illumination level, magnification, or microscope used. Finally, demonstrating high accuracy and flexibility, this methodology presents a suitable technique for graphene layer number identification without the need for large datasets or expensive instruments.

2D materials↗

Efficient Generalized Boundary Detection Using a Sliding Information Distance

In this work, we present a general machine learning algorithm for boundary detection within general signals based on an efficient, accurate, and robust approximation of the universal normalized information distance. Our approach uses an adaptive sliding information distance (SLID) combined with a wavelet-based approach for peak identification to locate the boundaries. Special emphasis is placed on developing an adaptive formulation of SLID to handle general signals with multiple unknown and/or drifting section lengths. Although specialized algorithms may outperform SLID when domain knowledge is available, these algorithms are limited to specific applications and do not generalize. SLID excels in these cases. We demonstrate the versatility and efficacy of SLID on a variety of signal types, including synthetically generated sequences of tokens, binary executables for reverse engineering applications, and time series of seismic events.

42 ENGINEERING↗

Highly Reversible Lithiation of Additive Free T‐Nb 2 O 5 for a Quarter of a Million Cycles

Abstract Fast energy storage via intercalation requires quick ionic diffusion and often results in pseudocapacitive behavior. The cycling stability of such energy storage materials remains understudied despite the relevance to lifetime cost. Orthorhombic niobium oxide (T‐Nb 2 O 5 ) is a rapid ion intercalation material with a theoretical capacity of 201.7 mAh g −1 (Li 2 Nb 2 O 5 ) and good cycling stability due to the minimal unit cell strain during (de)intercalation. Prior reports of T‐Nb 2 O 5 cycling between 1.3–3.1 V versus Li/Li + noted a 50% loss in capacity after 10 000 cycles. Here, cyclic voltammetry is used to identify the role of the voltage window, state of charge, and potentiostatic holds on the cycling stability of mesoporous T‐Nb 2 O 5 thin films. Films cycled between 1.2–3.0 V versus Li/Li + without voltage holds (Li 1.1 Nb 2 O 5 ) exhibited extreme cycling stability with 90.8% capacity retention after 0.25 million cycles without detectable morphological/crystallographic changes. In contrast, the inclusion of 60 s voltage holds (Li 2.18 Nb 2 O 5 ) led to rapid capacity loss with 61.6% retention after 10 000 cycles with corresponding X‐ray diffraction evidence of amorphization. Cycling with other limited voltage windows identifies that most crystallographic degradation occurs at higher extents of lithiation. These results reveal remarkable stability over limited conditions and suggest that T‐Nb 2 O 5 amorphization is associated with high extents of lithiation.

25 ENERGY STORAGE↗

ZIF‐8 Membrane Permselectivity Modification by Manganese(II) Acetylacetonate Vapor Treatment

Abstract Vapor‐phase treatment of ZIF‐8 membranes with manganese(II) acetylacetonate (Mn(acac) 2 ) allows permselectivity tuning. Propylene/propane selectivity increases from 31 to 210 after the Mn(acac) 2 treatment at 165 °C for 30 min, while selectivities increase from 14.6 to 242 for H 2 /CH 4 , from 2.9 to 38 for CO 2 /CH 4 , from 2.4 to 29 for CO 2 /N 2 , and from 2.9 to 7.5 for O 2 /N 2 , after Mn(acac) 2 treatment at 175 °C for 30 min. Stable equimolar propylene/propane mixture selectivity of 165 at ambient temperature and 4 bar equimolar feed with a propylene flux of 8.3×10 −4 mol m −2 s −1 is established. A control experiment excludes thermal treatment alone causing these changes. XPS analysis reveals the presence of Mn(acac) 2 on the outer surface of the vapor‐treated ZIF‐8 membranes while no other changes are detectable by X‐ray diffraction and infrared spectroscopy.

Hayashi, Mikio↗

ZIF‐8 Membrane Permselectivity Modification by Manganese(II) Acetylacetonate Vapor Treatment

Vapor-phase treatment of ZIF-8 membranes with manganese(II) acetylacetonate (Mn(acac) 2 ) allows permselectivity tuning. Propylene/propane selectivity increases from 31 to 210 after the Mn(acac) 2 treatment at 165 °C for 30 min, while selectivities increase from 14.6 to 242 for H 2 /CH 4 , from 2.9 to 38 for CO 2 /CH 4 , from 2.4 to 29 for CO 2 /N 2 , and from 2.9 to 7.5 for O 2 /N 2 , after Mn(acac) 2 treatment at 175 °C for 30 min. Stable equimolar propylene/propane mixture selectivity of 165 at ambient temperature and 4 bar equimolar feed with a propylene flux of 8.3×10 −4 mol m −2 s −1 is established. Furthermore, a control experiment excludes thermal treatment alone causing these changes. XPS analysis reveals the presence of Mn(acac) 2 on the outer surface of the vapor-treated ZIF-8 membranes while no other changes are detectable by X-ray diffraction and infrared spectroscopy.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Potential for Midtreatment Albumin-Bilirubin (ALBI) Score to Individualize Liver Stereotactic Body Radiation Therapy

Our individualized functional response adaptive approach to liver stereotactic body radiation therapy (SBRT) with assessment of indocyanine green (ICG) retention at baseline and midtreatment to detect subclinical changes in liver function, permitting dose adjustment, has decreased toxicity while preserving efficacy. We hypothesized that assessment of the albumin-bilirubin (ALBI) score at baseline and midtreatment would allow for more practical identification of patients at risk for treatment-related toxicity (TRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of duration and missing data on the long-term photovoltaic degradation rate estimation

Accurate quantification of photovoltaic (PV) system degradation rate (R D ) is essential for lifetime yield predictions. Although R D is a critical parameter, its estimation lacks a standardized methodology that can be applied on outdoor field data. The purpose of this paper is to investigate the impact of time period duration and missing data on R D by analyzing the performance of different techniques applied to synthetic PV system data at different linear R D patterns and known noise conditions. The analysis includes the application of different techniques to a 10-year synthetic dataset of a crystalline Silicon PV system, with emulated degradation levels and imputed missing data. Here, the analysis demonstrated that the accuracy of ordinary least squares (OLS), year-on-year (YOY), autoregressive integrated moving average (ARIMA) and robust principal component analysis (RPCA) techniques is affected by the evaluation duration with all techniques converging to lower R D deviations over the 10-year evaluation, apart from RPCA at high degradation levels. Moreover, the estimated R D is strongly affected by the amount of missing data. Filtering out the corrupted data yielded more accurate R D results for all techniques. It is proven that the application of a change-point detection stage is necessary and guidelines for accurate R D estimation are provided.

14 SOLAR ENERGY↗

Use of non-contact voltmeter to quantify potential induced degradation in CdTe modules

Potential induced degradation (PID) is a significant reliability issue for photovoltaic modules in the field. Conventionally, to detect the PID-affected modules, all the modules in a string are individually disconnected and measured using I-V (current–voltage) tracers. It is extremely time-consuming, expensive and unsafe (if the module connectors are field aged) approach. In our approach, we aim detecting the PID-affected modules quickly, inexpensively and safely without disconnecting individual modules in the string. In this study, contactless electrostatic voltmeter’s (ESV) strength was explored to detect the PID-affected cadmium telluride (CdTe) modules in a string. These contactless measurements on high-voltage PV strings could make this technique unique and preferable to detect PID-affected modules in a string compared to the I-V curve method. In this work, a CdTe module was stressed for PID using the Aluminum (Al) foil method in a walk-in environmental chamber, which resulted in a reduction of module's peak current (I max ), peak voltage (Vmax), and fill factor (FF), and hence power (Pmax). Outdoor light I-V, EL, and ESV measurements were performed pre- and post-PID to determine the effectiveness of the non-contact ESV technique. Further, the ESV technique successfully detected the change in V max , and hence Pmax, compared to the pre-and post-PID conditions. A difference of less than 2% was observed in the results of the non-contact and non-interruptive method compared to the conventionally used interruptive voltmeter or I-V tracer method. This technique and the test results demonstrate a significant promise to identify poor-performing modules in PV string without disconnection of individual modules in the string.

14 SOLAR ENERGY↗

High expression of Notch2 drives tongue squamous cell carcinoma carcinogenesis

Tongue squamous cell carcinoma (TSCC) is one of the most common cancers in the oral cavity. Notch signaling is frequently dysregulated in cancer. However, the role of Notch2 in TSCC is not well understood. The aim of this study was to investigate the effect of abnormal expression of Notch2 in TSCC. The expression of Notch2 was tested in 47 pairs of tissues from tongue cancer and normal samples by using immunohistochemical staining. Tongue cancer cells were transfected with siRNA or plasmid. The proliferation of the cells was tested by the CCK8 assay and colony formation assay. Subcutaneous tumor model was established to observe tumor growth. Transwell assay was used to detect the changes of cell migration and invasion ability. A humanized anti-Notch2 antibody was used to TSCC cells. We found that Notch2 was upregulated in tongue carcinoma tissues. Knocking down the expression of Notch2 by siRNA in the TSCC cell lines decreased proliferation ability both in vitro and in vivo. In addition, migration and invasion abilities were inhibited by knockdown of Notch2 in the TSCC cells. However, overexpression of Notch2 increased tongue cancer cell proliferation, invasion and migration. The humanized anti-Notch2 antibody inhibited TSCC cell growth. The results indicated that Notch2 is an oncogene in tongue squamous cell carcinoma and may become the target of a new approach for treating TSCC.

60 APPLIED LIFE SCIENCES↗

X-ray diffraction characterization of magnetostriction in Terfenol-D

The magnetostrictive response of a Terfenol-D pellet was measured via a laboratory-based X-ray diffractometer. X-ray diffraction patterns were collected from the pellet sample with and without the presence of an applied magnetic field (~30 mT) generated by placing a large magnet under the pellet. A standard reference material, Silicon 640c, was employed as an internal standard. Magnetostriction values of 323 and 227 ppm Δl/l were determined for the (104) and (110) indexed peaks, respectively, assuming a rhombohedral structure for Terfenol-D. A threshold noise level value of ~20 to 30 ppm Δl/l was suggested based on before/after measurements in the absence of the applied field. No clear evidence of domain wall rotation was detected via changes in relative intensities of diffraction peaks in the presence of the applied magnetic field.

Magnetostriction↗

Regeneration of Active Surface Alloys during Cyclic Oxidation and Reduction: Oxidation of H 2 on Pd/Ag(111)

The surface morphology and composition of a catalyst during excursions between oxidizing and reducing conditions can change substantially, especially in bimetallic alloys. Both thermodynamic and kinetic factors play a role in determining the properties of alloy surfaces where the active phase may be a metastable state. Previously, Ag oxide reduction was shown to be dramatically enhanced when Pd is on the surface; however, Pd is more stable when dissolved in Ag, raising the question as to whether a highly active Pd surface state will persist over multiple reaction cycles—a requirement for catalytic function. Experiments herein demonstrate that the enhanced chemical functionality due to the presence of Pd on the surface is retained, based on the enhanced rate of silver oxide reduction over multiple oxidation/reduction cycles for a Pd/Ag(111) model. Repeated oxidation and reduction promote PdAg alloying and reversible structural and compositional changes are detected using X-ray photoelectron spectroscopy. Furthermore, this study establishes that metastable phases can persist in reactive processes on surfaces, indicating their potential in heterogeneous catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗