Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Calorimeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

In-Flight Calibration of Hitomi Soft X-Ray Spectrometer. (1) Background

The X-Ray Spectrometer (XRS) instrument of Suzaku provided the first measurement of the non-X-ray background (NXB) of an X-ray calorimeter spectrometer, but the data set was limited. The Soft X-ray Spectrometer (SXS) instrument of Hitomi was able to provide a more detailed picture of X-ray calorimeter background, with more than 360 ks of data while pointed at the Earth, and a comparable amount of blank-sky data. These data are important not only for analyzing SXS science data, but also for categorizing the contributions to the NXB in X-ray calorimeters as a class. In this paper, we present the contributions to the SXS NXB, the types and effectiveness of the screening, the interaction of the screening with the broad-band redistribution, and the residual background spectrum as a function of magnetic cut-off rigidity. The orbit-averaged SXS NXB in the range 0.3-12 keV was 4 × 10(exp −2) counts s(exp −1) -sq cm. This very low background in combination with groundbreaking spectral resolution gave SXS unprecedented sensitivity to weak spectral lines.

Kilbourne, Caroline A.↗

CFD Simulations of the IHF 13-Inch Nozzle Flow: 55° Sphere-Cone Model, Manufactured Fences and Gaps

This paper reports computational analyses of tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using 23.6-cm diameter, 55° sphere-cone models placed in a free jet downstream of the 33.0-cm diameter conical nozzle in the 60-MW Interaction Heating Facility. Some of the sphere-cone models include surface features such as manufactured fences and gaps intended to simulate effects of differential recession, all of which disturb the flow, producing augmented heating locally and downstream. Test calibration data were obtained using slug and Gardon gage stagnation calorimeters, and a sphere-cone calorimeter model with six Gardon heat flux gages and five pressure gages. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested, and comparisons with the experimental measurements. Various issues related to testing are considered: diffuser flow capture, flow characterization based on the calorimeter data, effects of the model surface recession, and prediction of surface quantities for the models with surface features. These simulations take into account nonuniform total enthalpy profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields.

Arc-jets↗

CALET Search for Electromagnetic Counterparts of Gravitational Waves During the LIGO/Virgo O3 Run

The CALorimetric Electron Telescope (CALET)on the International Space Station consists of a high-energy cosmic-ray CALorimeter (CAL)and a lower-energy CALET Gamma-ray Burst Monitor (CGBM). CAL is sensitive to electrons up to 20 TeV, cosmic-ray nuclei from Z=1 throughZ∼40, and gamma rays over the range1 GeV–10 TeV. CGBM observes gamma rays from 7 keV to 20 MeV. The combined CAL-CGBM instrument has conducted a search for gamma-ray bursts (GRBs)since 2015 October. We report here on the results of a search for X-ray/gamma-ray counterparts to gravitational-wave events reported during the LIGO/Virgo observing run O3. No events have been detected that pass all acceptance criteria. We describe the components, performance, and triggering algorithms of the CGBM—the two Hard X-ray Monitors consisting of LaBr3(Ce)scintillators sensitive to 7 keV–1 MeV gamma rays and a Soft Gamma-ray Monitor BGO scintillator sensitive to 40 keV–20 MeV—and the high-energy CAL consisting of a charge detection module, imaging calorimeter, and the fully active total absorption calorimeter. The analysis procedure is described and upper limits to the time-averaged fluxes are presented.

Gamma-ray astronomy↗

Development and Application of a Novel Calorimetry Technique for the Study of Lithium-Ion Cell Thermal Runaway

Lithium-ion battery technology is widely used and is attractive due to demonstrated specific energies in the 200-300 W-hr/kg range. The excellent, mass-efficient energy storage capability of lithium-ion batteries has led to their use on many aerospace platforms. However, lithium-ion batteries can exhibit thermal runaway behavior wherein stored electrochemical energy is released rapidly as a result of thermal or mechanical failure, electrochemical abuse, internal or external short circuiting. A single cell undergoing thermal runaway within a battery has the potential to induce thermal runaway in adjacent cells if heat dissipation is not properly managed and can result in a catastrophic failure of the battery. Designing batteries that are resistant to thermal runaway propagation requires an understanding of, not only, total energy yield but also the means by which that energy is liberated from the cell. While Accelerating Rate Calorimetry and other techniques provide total thermal runaway energy yield, they do not provide the fractional breakdown of energy liberated via conduction through the cell casing from that which is vented from the cell as hot gases and effluents. Such data are needed to inform battery thermal design and analysis. To measure the total energy yield, the fraction conducted through the cell casing, and the fraction lost due to gases and effluents, NASA developed Fractional Thermal Runaway Calorimetry (FTRC). Two calorimeters have been developed and demonstrated, the Small-format- and Large-format Fractional Thermal Runaway Calorimeters (S-FTRC and L-FTRC, respectively). The technique has been successfully applied to small- and large-format cells (2.4-3.5 Ah and >100 Ah capacity, respectively) and has given new insights into Li-ion cell thermal runaway. Development of the calorimeters is discussed and results from the initial thermal runaway testing campaigns are presented.

Lithium-Ion Cell↗

System Design and Implementation of the Detector Assembly of the Astro-H Soft X-Ray Spectrometer

The soft x-ray spectrometer (SXS) onboard Astro-H presents to the science community unprecedented capability (less than 7 eV at 6 keV) for high-resolution spectral measurements in the range of 0.5-12 keV to study extended celestial sources. At the heart of this SXS is the x-ray calorimeter spectrometer (XCS) where detectors (calorimeter array and anticoincidence detector) operate at 50 mK, the bias circuit operates at nominal 1.3 K, and the first stage amplifiers operateat 130 K, all within a nominal 20 cm envelope. The design of the detector assembly in this XCS originates from the Astro-E x-ray spectrometer (XRS) and lessons learned from Astro-E and Suzaku. After the production of our engineering model, additional changes were made in order to improve our flight assembly process for better reliability and overall performance. In this poster, we present the final design and implementation of the flight detector assembly, show comparison of parameters and performance to Suzakus XRS, and list susceptibilities to other subsystems as well as our lessons learned.

soft x-ray spectrometer↗

Calibration technique for electromagnetic flowmeters

Thermal calorimetric method is used to calibrate electromagnetic flowmeters for liquid alkali metals. The electromagnetic flowmeter is placed in the liquid metal flow system in series with a thermal calorimeter. Therefore, the calculated flow rate through the calorimeter can be compared directly with the respective electromagnetic flowmeter reading.

Sawochka, S. G.↗

Study of thermal effects on nickel-cadmium batteries

Isothermal continuous flow calorimeter is designed to test a nickel-cadmium battery under numerous orbital conditions. This sensitive calorimeter collects cell data such as oxygen pressure and rate of heat generation, and calculates changes in enthalpy.

Foley, R. T.↗

Fluidic device for measuring constituent masses of a flowing binary gas mixture

Device consists of fluidic humidity sensor and specially designed flow calorimeter. Calorimeter provides readings of gas stream temperature rise produced by measured amount of heat that is dissipated into gas stream, and humidity sensor is used to obtain continuous calculation of specific heat capacity of gas mixture.

Prokopius, P. R.↗

Boundary cooled rocket engines for space storable propellants

An evaluation of an existing analytical heat transfer model was made to develop the technology of boundary film/conduction cooled rocket thrust chambers to the space storable propellant combination oxygen difluoride/diborane. Critical design parameters were identified and their importance determined. Test reduction methods were developed to enable data obtained from short duration hot firings with a thin walled (calorimeter) chamber to be used quantitatively evaluate the heat absorbing capability of the vapor film. The modification of the existing like-doublet injector was based on the results obtained from the calorimeter firings.

Kesselring, R. C.↗

Measured catalycities of various candidate space shuttle thermal protection system coatings at low temperatures

Atom recombination catalytic rates for surface coatings of various candidate thermal protection system materials for the space shuttle vehicle were obtained from measurements in arc jet, air flow. The coatings, chrome oxides, siliconized carbon/carbon, hafnium/tantalum carbide on carbon/carbon, and niobium silicide, were bonded to the sensitive surface of transient slug calorimeters that measured the heat transfer rates to the coatings. The catalytic rates were inferred from these heat transfer rates Surface temperatures of the calorimeters varied from approximately 300 to 410 K.

Scott, C. D.↗

Hodoscope Measurements of the Spectrum of Cosmic Electrons Between 10 Gev and 100 Gev

In an attempt to reduce divergences among independent measurements of the electron spectrum above 10 GeV, electrons were detected with the aid of a large hodoscope which incorporates 8 trays of Geiger tubes and 10 scintillation counters into a calorimeter containing 33 radiation lengths of lead. This instrument was thoroughly calibrated up to 9 GeV with an electron synchrotron and was flown twice at a depth of 5 g/sq cm for a total of 30 hours at ceiling. Electron showers at 10 GeV are completely contained within the calorimeter where their ionization is sampled twelve times, and where hodoscope trays provide information on the geometrical distribution of shower particles. Electrons appeared in a histogram of number of events vs. a X2 measure of goodness of fit to electron shower curves as a clearly resolved peak standing well above the nuclear background. The initial ionization and the lateral spread of shower particles are consistent with those of calibration electrons. In contrast, the behavior of the nuclear continuum associated with minimum ionizing incident particles is different from that of calibration electrons but similar to that of nuclear events associated with incident helium nuclei. The differential electron spectrum from 10 to 100 GeV was obtained.

Meegan, C. A.↗

Thermal performance of multilayer insulations

Experimental and analytical studies were conducted in order to extend previous knowledge of the thermal performance and gas evacuation characteristics of three selected multilayer insulation (MLI) composites. Flat plate calorimeter heat flux measurements were obtained for 20- and 80- shield specimens using three representative layer densities over boundary temperatures ranging from 39 K (70 R) to 389 K (700 R). Laboratory gas evacuation tests were performed on representative specimens of each MLI composite after initially purging them with helium, nitrogen, or argon gases. In these tests, the specimens were maintained at temperatures between 128 K (230 R) and 300 K (540 R). Based on the results of the laboratory-scale tests, a composite MLI system consisting of 112 unperforated, double-aluminized Mylar reflective shields and 113 water preconditioned silk net spacer pairs was fabricated and installed on a 1.22-m-(4-ft-) diameter calorimeter tank.

Keller, C. W.↗

Alternative explanations for the observations of unknown heavy-mass particles in cosmic-ray showers

Several experiments were conducted in the 1960s in search of unknown heavy-mass strongly interacting particles in cosmic rays using an experimental technique suggested by B. Peters et al. (1965). The experiments looked for particles which are delayed more than 20 nanoseconds behind the front of EAS and deposit more than 20 GeV in a calorimeter. None of the experimental results demand the existence of such particles. All observations can be interpreted as due either to incident nuclei or to inaccurate estimates of the systematics with energy determination using calorimeters.

Orth, C. D.↗

Installation for the study of the angular distribution of cosmic muons with super-high energies at large zenith angles

An installation consisting of an ionization calorimeter and a counter hodoscope can be used to record cascade showers caused by the electromagnetic interactions of muons with superhigh energies in the cosmic ray horizontal flux. The direction of the muons is determined by a hodoscope consisting of 2196 counters. The information obtained makes it possible to restore the angular and energy distribution of the cosmic muons, which, in turn, makes it possible to determine the mechanism of their generation. The accuracy with which the angle of the passing particle is determined is discussed in detail in addition to the causes which can introduce distortions, such as shower accompaniment of neutrons, escape of shower electrons from the calorimeter, random coincidences, etc.

Borog, V. V.↗

Experimentally-determined external heat loss of automotive gas turbine engine

An external heat balance was conducted on a 150 HP two-shaft automotive gas turbine engine. The engine was enclosed in a calorimeter box and the temperature change of cooling air passing through the box was measured. Cooling airflow ranges of 1.6 to 2.1 lb-per-second and 0.8 to 1.1 lb-per-second were used. The engine housing heat loss increased as the cooling airflow through the calorimeter box was increased, as would be the case in a moving automobile. The heat balance between the total energy input and the sum of shaft power output and various losses compared within 30 percent at engine idle speeds and within 7 percent at full power.

Meng, P. R.↗

A device for rapid determination of thermophysical properties of phase-change wind-tunnel models

An experimental method for direct measurement of the thermophysical properties of wind tunnel heat transfer models was developed. The technique consists of placing the model under a bank of high intensity, radiant heaters so that the fast opening water cooled shutters, which isolate the heater bank from the model, allow a step-input heat rate to be applied. Measurements of the heat transfer rate coupled with a surface-temperature time history of the same material are sufficient to determine the material thermophysical properties. An infrared thermometer is used to measure model surface temperature and a slug calorimeter provides heat transfer rate information. The output from the infrared thermometer and calorimeter is then fed into an analog-to-digital converter which provides digitized data to a computer. This computer then calculates combined thermophysical properties and a teleprinter prints out all the data. Thus, results are available within 7 minutes of test initiation as opposed to the weeks or months required using prior techniques.

Creel, T. R., Jr.↗

On the high energy proton spectrum measurements

Reasons are considered for the steepening of the cosmic-ray proton spectrum above 1000 GeV and the 20% increase in inelastic cross sections of protons on carbon and polyethylene nuclei between 20 and 600 GeV observed in the Pronton 1, 2, and 3 satellite experiments. It is shown that these unexpected observations can arise as consequences of energy-dependent albedo (backscatter) from the calorimeter used in the experiments. The experimental apparatus employed is described along with an experimental setup for studying the albedo from the calorimeter, and experimental results are presented concerning the magnitude and energy variation of the albedo. The effects this albedo could have on the proton spectrum and cross-section measurements of the Proton experiments are estimated. The origin and nature of the albedo particles are briefly investigated.

Ellsworth, R. W.↗

An instrument to measure the spectrum of cosmic ray iron and other nuclei to above 100 GeV/nucleon

A balloon-borne instrument system for the study of cosmic ray composition in the energy region beyond 100 GeV/nucleon is described. The large area detector incorporates an ionization spectrometer or calorimeter to determine the energy of the incident particles which is calibrated in flight by a gas Cerenkov counter filled with freon 12 at 20 psi. Calibration of calorimeter response indicates that the effects of ionization energy loss and nucleon fragmentation are correctly accounted for in a Monte Carlo simulation. A charge measuring module consisting of five scintillators and a lucite Cerenkov counter is used to determine the charge and position of the incoming particles. A spatial resolution of 5 to 10 cm has been obtained by using the ratios of pulse heights in different photomultiplier tubes aimed at the same scintillators within the module. The detector represents the heaviest cosmic ray experiment that can be flown over 30 km using the dynamic launching technique commonly employed.

Arens, J. F.↗