Closed form solution to the semi-infinite cylindrical shell problem.

Reconsideration of the problem of a complete semiinfinite circular cylindrical shell with a square cage investigated earlier by Reissner and Simmonds (1966). It is shown that the solution can be found in closed form rather than in the form of Fourier series, provided that the boundary data on the end of the shell are 'slowly varying.'

Sanders, J. L., Jr.↗

Study of ball bearing torque under elastohydrodynamic lubrication

Spinning and rolling torques were measured in an angular-contact ball bearing with and without a cage under several lubrication regimes in a modified NASA spinning torque apparatus. Two lubricants were used, a di-2 ethylhexyl sebacate and a synthetic paraffinic oil, at shaft speeds of 1000, 2000, and 3000 rpm and bearing loads from 10 lbs to 90 lbs. An analytical model was developed from previous spinning friction models to include rolling with spinning under lubrication regimes from thin film to flooded conditions. The bearing torque values have a wide variation, under any condition of speed and load, depending on the amount of lubricant present in the bearing. The analytical model compared favorably with experimental results under several lubrication regimes.

Townsend, D. P.↗

STRAP 4 sounding rocket attitude control system

A sounding rocket attitude control system is reported that uses rate integrated gyros operating in both closed loop and open loop modes at very low drift rates. In normal operation the gyros are zeroed on a nearby star and torqued to the proper location in the closed loop mode; rate output is electronically integrated to provide a position displacement signal. Once closed loop torquing is completed, the caging loop is opened and the gyro is operated as angular displacement sensor to provide limit cycle control while viewing the target.

Shrewsberry, D. J.↗

V/STOL tilt rotor study. Volume 6: Hover, low speed and conversion tests of a tilt rotor aeroelastic model (Model 300)

Stability and control tests of a scale model of a tilt rotor research aircraft were conducted. The characteristics of the model for hover, low speed, and conversion flight were analyzed. Hover tests were conducted in a rotor whirl cage. Helicopter and conversion tests were conducted in a low speed wind tunnel. Data obtained from the tests are presented as tables and graphs. Diagrams and illustrations of the test equipment are provided.

Marr, R. L.↗

Effects of oxygen-augmented atmosphere on the immune response.

Antibovine serum albumin antibody and nonspecific protein production was evaluated in female rabbits (11-14.5 kg) housed in special cages ventilated with 20% or 40% oxygen at normal barometric pressure. Animals exposed to 40% oxygen do not show normal steady increase of serum antibody. Instead, their titers show a pattern of undershoot, overshoot, undershoot, and finally equilibration at a subnormal level; they have a depressed popliteal node polysome level and have an abnormally low proportion of membrane-bound polysomes. They also show reduced capability of popliteal nodes to synthesize protein (as expected from the reduced number of polysomes). However, the ratio of newly-synthesized specific antibody: nonspecific protein remains normal.

Guttman, H. N.↗

Environmental control and waste management system design concept

Passive device contains both solid and liquid animal waste matter for extended period without being cleaned and without contaminating animal. Constant airflow dries solid waste and evaporates liquid matter. Technique will maintain controlled atmospheric conditions and cage cleanliness during periods of 6 months to 1 year.

Gandy, A. R.↗

Modernization of the 60-inch telescope at the Mount Wilson Observatory

A contract for modernization of the Mount Wilson 60-inch telescope was awarded. Under this contract, the original hour angle and declination drives were replaced, digital coordinate readouts were added, a Cassegrain/ coude flip cage was built and installed, the telescope was completely rewired, a new control console was installed, and a coude spectrograph was completed. Extensive building modifications also were made to provide a working floor at mezzanine level for a computer and a coude observing room. These modifications and additions were completed by February 1970, and the telescope returned to regular and continuous use for stellar and planetary astronomy.

Source record↗

Study of ball bearing torque under elastohydrodynamic lubrication

Spinning and rolling torques were measured in an angular-contact ball bearing with and without a cage under several lubrication regimes in a modified NASA spinning torque apparatus. Two lubricants were used - a di-2 ethylhexyl sebacate and a synthetic paraffinic oil, at shaft speeds of 1000, 2000, and 3000 rpm and bearing loads from 45 newtons (10 lb) to 403 newtons (90 lb). An analytical model was developed from previous spinning friction models to include rolling with spinning under lubrication regimes from thin film to flooded conditions. The bearing torque values have a wide variation, under any condition of speed and load, depending on the amount of lubricant present in the bearing. The analytical model compared favorably with experimental results under several lubrication regimes.

Townsend, D. P.↗

Conditioned suppression, punishment, and aversion

The aversive action of visual stimuli was studied in two groups of pigeons which received response-contingent or noncontingent electric shocks in cages with translucent response keys. Presentation of grain for 3 sec, contingent on key pecking, was the visual stimulus associated with conditioned punishment or suppression. The responses of the pigeons in three different experiments are compared.

Orme-Johnson, D. W.↗

Renal parameter estimates in unrestrained dogs

A mathematical formulation has been developed to describe the hemodynamic parameters of a conceptualized kidney model. The model was developed by considering regional pressure drops and regional storage capacities within the renal vasculature. Estimation of renal artery compliance, pre- and postglomerular resistance, and glomerular filtration pressure is feasible by considering mean levels and time derivatives of abdominal aortic pressure and renal artery flow. Changes in the smooth muscle tone of the renal vessels induced by exogenous angiotensin amide, acetylcholine, and by the anaesthetic agent halothane were estimated by use of the model. By employing totally implanted telemetry, the technique was applied on unrestrained dogs to measure renal resistive and compliant parameters while the dogs were being subjected to obedience training, to avoidance reaction, and to unrestrained caging.

Rader, R. D.↗

Shuttle filter study. Volume 2: Contaminant generation and sensitivity studies

Contaminant generation studies were conducted at the component level using two different methods, radioactive tracer technique and gravimetric analysis test procedure. Both of these were reduced to practice during this program. In the first of these methods, radioactively tagged components typical of those used in spacecraft were studied to determine their contaminant generation characteristics under simulated operating conditions. Because the purpose of the work was: (1) to determine the types and quantities of contaminants generated; and (2) to evaluate improved monitoring and detection schemes, no attempt was made to evaluate or qualify specific components. The components used in this test program were therefore not flight hardware items. Some of them had been used in previous tests; some were obsolete; one was an experimental device. In addition to the component tests, various materials of interest to contaminant and filtration studies were irradiated and evaluated for use as autotracer materials. These included test dusts, plastics, valve seat materials, and bearing cage materials.

Source record↗

Operating characteristics of 120-millimeter-bore ball bearings at 3 million DN

A parametric study was performed with split inner-race 120-mm-bore angular-contact ball bearings at a speed of 25,000 rpm (3 million DN) at initial contact angles of 20 deg and 24 deg. Provisions were made for outer- and inner-race cooling and for injection of lubricant into the bearing through a number of radial holes in the split inner-race of the bearing. Oil flow and coolant rate to the bearing was controlled and varied for a total up to approximately 3.2 gal/min. Bearing temperature was found to decrease as the total lubricant flow to the bearing increased. However, at intermediate flow rates temperature began to increase with increasing flow. Power consumption increased with increasing flow rate. Bearing operating temperature, differences in temperatures between the inner and outer races, and bearing power consumption can be tuned to any desirable operating requirement. Cage speed increased by not more than 2 percent with increasing oil flow to the inner race.

Zaretsky, E. V.↗

Determination of cardiac size from chest roentgenograms following Skylab missions

Decreased cardiothoracic transverse diameter ratios following Mercury, Gemini and Apollo space flights have been reported previously. To evaluate further changes in cardiac size, standard posteroanterior chest films in systole and diastole were obtained before flight and within a few hours after recovery on each of the Skylab astronauts. Postflight chest X-rays were visually compared to the preflight roentgenograms for possible changes in pulmonary vasculature, lung parenchyma, bony or soft tissue structures. From these roentgenograms the following measurements were obtained: cardiac and thoracic transverse diameters, cardiothoracic transverse diameter ratio, cardiac area from the product of both diagonal diameters, cardiac silhouette area by planimetry, thoracic cage area and cardiothoracic area ratio. The postflight frontal cardiac silhouette sizes were significantly decreased when compared with the respective preflight values (P0.05 or 0.01). The observed changes are thought to be related to postflight decrease in the intracardiac chamber volume.

Nicogossian, A. E.↗

Microelectronic bioinstrumentation systems

The possibility of using RF fields to power biologically implanted transmitters used in biomedical experiments was investigated. This approach would be especially useful when animal subjects are strapped in chairs or confined in cages. A telemetry system using an external source of energy has the additional advantage of not being limited in operation by battery lifetime and can therefore operate for virtually infinite lengths of time. A description of a system based on this principle is given. Progress in the development of battery-driven transmitters is also reported, including an ingestible temperature telemetry system and a resistance-to-pulse frequency convertor for implantable temperature telemetry systems.

Ko, W. H.↗

Influences of physical training on the heart of dogs

To investigate the effects of physical training on cardiac dimensions and function, eight dogs were exercised for 12 weeks by treadmill running 1 hour/day, 5 days/week. Five dogs were confined in cages as controls for an 8-week period. Heart rates were monitored by telemetry during rest and exercise. Maximum QRS spatial magnitudes were calculated from records of McFee lead electrocardiograms. Left ventricular end-diastolic dimensions were determined radiographically by the bead and clip technique. Training produced statistically significant decreases in heart rate at rest and at a standard work load of 6.1 mph on a level treadmill and statistically significant increases in work load at a standard heart rate of 194 beats/min. Improvements were rapid during the first 4 weeks of training but gradual during the remaining 8 weeks. Training caused small but statistically significant increases in left ventricular end-diastolic wall thickness, estimated left ventricular mass, and maximum QRS spatial magnitude.

Wyatt, H. L.↗

OH-58 helicopter transmission failure analysis

The OH-58 main transmission gearbox was run at varying output torques, speeds, and oil cooling rates. The gearbox was subsequently run to destruction by draining the oil from the gearbox while operating at a speed of 6200 revs per minute and 36,000 inch-pounds output torque. Primary cause of gearbox failure was overheating and melting of the planet bearing aluminum cages. Complete failure of the gearbox occurred in 28 1/2 minutes after the oil pressure dropped to zero. The alternating and maximum stresses in the gearbox top case were approximately 10 percent of the endurance limit for the material. Deflection of the bevel gear at 67000 inch-pounds output torque indicate a marginal stiffness for the bevel gear supporting system.

Townsend, D. P.↗

Development of an advanced high-temperature fastener system for advanced aerospace vehicle application

The results of a program to develop a lightweight high temperature reusable fastening system for aerospace vehicle thermal protection system applications are documented. This feasibility program resulted in several fastener innovations which will meet the specific needs of the heat shield application. Three systems were designed from Hayes 188 alloy and tested by environmental exposure and residual mechanical properties. The designs include a clinch stud with a collar retainer, a weld stud with a split ring retainer, and a caged stud with a collar retainer. The results indicated that a lightweight, reusable, high temperature fastening system can be developed for aerospace vehicle application.

Kull, F. R.↗