Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CURRENT AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Design of Digital Acquisition for Beam Current Monitor

As a part of the Proton Improvement Plan II (PIP-II) at Fermilab, instrumentation systems are being modernized to take advantage of the higher speeds and ease of use offered by standardized embedded systems like MicroTCA. A rear-transition module (RTM) is being designed to interface with said embedded systems. In each of the four identical channels on the RTM, the differential signal from an alternating-current current transformer (ACCT) transimpedance amplifier will again be amplified by a differential operation-amplifier, then filtered by a low-pass topology. The conditioned signal is then digitized at a maximum of 10MS/s by an analog to digital converter (ADC) integrated circuit. After digitization, the ADC passes the data to an off the shelf AdvancedMC (AMC) Xilinx FPGA module using low voltage differential signals. This paper will describe the simulation of analog circuitry for signal conditioning, simulation of digital signal integrity based on physical design as well as verification of design characteristics critical to signal integrity. This work aims to create a methodology that can be applied to future RTMs requiring application of high-speed digital design principles.

White, Turner [Fermilab] (ORCID:0009000348159256)↗

Solid state, S-band, power amplifier

The final design and specifications for a solid state, S-band, power amplifier is reported. Modifications from a previously proposed design were incorporated to improve efficiency and meet input overdrive and noise floor requirements. Reports on the system design, driver amplifier, power amplifier, and voltage and current limiter are included along with a discussion of the testing program.

Digrindakis, M.↗

Instrumentation for measuring low-level currents/voltages

Instrumentation consists of high-output resistance voltage measuring amplifier (electrometer) and current-to-frequency converter (current digitizer) coupled to set of timers and counters. Digital display of time-averaged signals with amplitudes varying over 11 decades is possible.

Richmond, R. G.↗

Low-resistance continuity tester

IC printed-circuit board tester measures resistance as low as 0.1 ohm but uses little power. Two 4.7 kilohm resistors and connected transistors prevent current flow through operational amplifier until probe circuit is complete, eliminating need for on/off switch. Zener diode in series with amplifier output prevents audio oscillator operation until output has sufficient amplitude. Circuit utilizes 741 operational amplifier on 11.2 volt battery or lower voltage amplifiers.

Reasoner, R. B.↗

Portable I/V-Curve Tester

Electronic load circuit for displaying current/voltage characteristic curves of power sources uses low-cost low-power CMOS operational amplifiers to control load current flowing through power MOSFET Q2 and main load transistor Q3. Thermal cutoff device turns off transistor Q3 in case of overload. To maximize battery life, battery is connected via "push-to-read" momentary-contact pushbutton switch.

Cole, S. W.↗

Feedforward, high density, programmable read only neural network based memory system

Neural network-inspired, nonvolatile, programmable associative memory using thin-film technology is demonstrated. The details of the architecture, which uses programmable resistive connection matrices in synaptic arrays and current summing and thresholding amplifiers as neurons, are described. Several synapse configurations for a high-density array of a binary connection matrix are also described. Test circuits are evaluated for operational feasibility and to demonstrate the speed of the read operation. The results are discussed to highlight the potential for a read data rate exceeding 10 megabits/sec.

Daud, Taher↗

Modelling and design for PM/EM magnetic bearings

A mathematical model of a permanent magnet/electromagnet (PM/EM) radially active bearing is presented. The bearing is represented by both a reluctance model and a stiffness model. The reluctance model analyzes the magnetic circuit of the PM/EM bearings. By combining the two models, the performance of the bearing can be predicted given geometric dimensions, permanent magnet strength, and the parameters of the EM coils. The overall bearing design including the PM and EM design is subject to the performance requirement and physical constraints. A study of these requirements and constraints is discussed. The PM design is based on the required magnetic flux for proper geometric dimensions and magnet strength. The EM design is based on the stability and force slew rate consideration, and dictates the number of turns for the EM coils and the voltage and current of the power amplifier. An overall PM/EM bearing design methodology is proposed and a case study is also demonstrated.

Pang, D.↗

Nanoelectrode array for electrochemical analysis

A nanoelectrode array comprises a plurality of nanoelectrodes wherein the geometric dimensions of the electrode controls the electrochemical response, and the current density is independent of time. By combining a massive array of nanoelectrodes in parallel, the current signal can be amplified while still retaining the beneficial geometric advantages of nanoelectrodes. Such nanoelectrode arrays can be used in a sensor system for rapid, non-contaminating field analysis. For example, an array of suitably functionalized nanoelectrodes can be incorporated into a small, integrated sensor system that can identify many species rapidly and simultaneously under field conditions in high-resistivity water, without the need for chemical addition to increase conductivity.

47 OTHER INSTRUMENTATION↗

A wide bandwidth free-electron laser with mode locking using current modulation.

A new scheme for mode locking a free-electron laser (FEL) amplifier is proposed based on electron beam current modulation. It is found that certain properties of the original concept (Thompson and McNeil 2008 Phys. Rev. Lett. 100 203901), based on the energy modulation of electrons, are improved, including the spectral brightness of the source and the purity of the series of short pulses. Numerical comparisons are made between the new and old schemes and between a mode-locked FEL and a self-amplified spontaneous emission FEL. Illustrative examples using a hypothetical mode-locked FEL amplifier are provided. The ability to generate intense coherent radiation with a large bandwidth is demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evolution of a Langmuir wave in a weakly inhomogeneous plasma in a longitudinal electric field

The spatial evolution of a Langmuir wave excited by external sources in a weakly inhomogeneous electron plasma in a longitudinal electrostatic field is considered. It is shown that, in a longitudinal electrostatic field, a Langmuir wave can only be amplified in an inhomogeneous plasma provided that the current of trapped electrons exceeds that of untrapped electrons. In this case, as the wave propagates through the inhomogeneous region where its phase velocity increases, some untrapped electrons become trapped in the wave potential wells. As a result, the current of trapped electrons increases and the wave is amplified. Moreover, in the regions where the bulk electrons are localized, the minima of the wave are amplified to a greater extent than its maxima.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evolution of a Langmuir wave in a weakly inhomogeneous plasma in a longitudinal electric field

The spatial evolution of a Langmuir wave excited by external sources in a weakly inhomogeneous electron plasma in a longitudinal electrostatic field is considered. It is shown that, in a longitudinal electrostatic field, a Langmuir wave can only be amplified in an inhomogeneous plasma provided that the current of trapped electrons exceeds that of untrapped electrons. In this case, as the wave propagates through the inhomogeneous region where its phase velocity increases, some untrapped electrons become trapped in the wave potential wells. As a result, the current of trapped electrons increases and the wave is amplified. Moreover, in the regions where the bulk electrons are localized, the minima of the wave are amplified to a greater extent than its maxima.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Noise-optimal control of HEMT LNA's for compensation of temperature deviations

Noise-optimal control of high-electron mobility transistor low noise amplifier (HEMT LNA) bias voltage and current values was achieved at room temperature. The performance metric maximized was the amplifier gain divided by the amplifier input noise temperature, G/T(sub e). Additionally, the feasibility of automating the initial determination of bias settings was demonstrated in the laboratory. Simulation models of an HEMT were developed from available measurement data, installed on a Sun SPARC 1 workstation, and used in investigating several optimization algorithms. Simple tracking-type algorithms, which follow changes in optimum settings if started at or near the global optimum point, produced the best performance. Implementation of the optimization algorithms was performed using a three-stage Field Effect Transistor (FET) LNA and an existing test apparatus. Software was written to control the bias settings of the first stage of the LNA and to perform noise and gain measurements by using the test apparatus. The optimization control was then integrated with existing test software to create a master test and optimization program for test apparatus use.

Maccarley, C.↗

A 128-channel picoammeter system and its application on charged particle beam current distribution measurements

A 128-channel picoammeter system is constructed based on instrumentation amplifiers. Taking advantage of a high electric potential and narrow bandwidth in DC energetic charged beam measurements, a current resolution better than 5 fA can be achieved. Two sets of 128-channel strip electrodes are implemented on printed circuit boards and are employed for ion and electron beam current distribution measurements. Tests with 60 keV O{sup 3+} ions and 2 keV electrons show that it can provide exact boundaries when a positive charged particle beam current distribution is measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Amplification of mid-infrared lasers via backscattering in magnetized plasmas

We report that plasmas may be used as gain media for amplifying intense lasers, and external magnetic fields may be applied to improve the performance. For midinfrared lasers, the requisite magnetic field is on the megagauss scale, which can already be provided by current technologies. Designing the laser amplifier requires knowing the magnetized three-wave coupling coefficient, which is mapped out systematically in this paper. By numerically evaluating its formula, we demonstrate how the coupling coefficient depends on the angle of wave propagation, laser polarization, magnetic field strength, plasma temperature, and plasma density in the backscattering geometry. In conclusion, since the mediation is now provided by magnetized plasma waves, the coupling can differ significantly from unmagnetized Raman and Brillouin scatterings.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of FIR arrays with integrating amplifiers

The development of optimized photoconductor arrays suitable for far infrared space astronomical applications are described. Although the primary impetus is the production of a 16 by 16 element Ge:Ga demonstration array for SIRTF, the extension of this technology to Large Deployable Reflector (LDR) is considered. The optimization of Ge:Ga and Ge:Be photoconductor materials is discussed. In collaboration with Lawrence Berkeley Laboratory, measurements of FIR photoconductors with quantum efficiencies greater than 20 percent at 100 micrometers, and dark currents below 300 electrons/s are presented. Integrating J-FET amplifier technology is discussed. The current generation of integrating amplifiers has a demonstrated read noise of less than 20 electrons for an integration time of 100 s. The design is shown for a stackable 16 x n Ge:Ga array that utilizes a 16-channel monolithic version of the J-FET integrator. A part of the design is the use of a thin, thermally insulating substrate that allows the electronics to operate at the optimum temperature of 50 K while maintaining thermal and optical isolation from the detectors at 2 K. The power dissipation for the array is less than 16 mW. The array design may particularly be applicable to high resolution imaging spectrometers for LDR.

Young, Erick T.↗

Progress on diamond amplified photo-cathode

Two years ago, we obtained an emission gain of 40 from the Diamond Amplifier Cathode (DAC) in our test system. In our current systematic study of hydrogenation, the highest gain we registered in emission scanning was 178. We proved that our treatments for improving the diamond amplifiers are reproducible. Upcoming tests planned include testing DAC in a RF cavity. Already, we have designed a system for these tests using our 112 MHz superconducting cavity, wherein we will measure DAC parameters, such as the limit, if any, on emission current density, the bunch charge, and the bunch length. The diamond-amplified photocathode, that promises to support a high average current, low emittance, and a highly stable electron beam with a long lifetime, is under development for an electron source. The diamond, functioning as a secondary emitter amplifies the primary current, with a few KeV energy, that comes from the traditional cathode. Earlier, our group recorded a maximum gain of 40 in the secondary electron emission from a diamond amplifier. In this article, we detail our optimization of the hydrogenation process for a diamond amplifier that resulted in a stable emission gain of 140. We proved that these characteristics are reproducible. We now are designing a system to test the diamond amplifier cathode using an 112MHz SRF gun to measure the limits of the emission current's density, and on the bunch charge and bunch length.

43 PARTICLE ACCELERATORS↗