Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONTAMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Development of the Contamination Distribution Centered Toxics Mobility Vulnerability Index in the Beaumont–Port Arthur Region of Texas

This study advances the Toxics Mobility Inventory (TMI) and the Toxics Mobility Vulnerability Index (TMVI) to develop a new tool to assess the movement of hazardous substances and their implications for vulnerable communities. It emphasizes the need to include contamination distribution variables in such indices to address disproportionate impacts and more accurately reflect vulnerability. The study uses the TMI framework and TMVI methodology in the Beaumont–Port Arthur region of Texas, also integrating contamination distribution considerations into the analysis to develop a new framework and process. The new Contamination Distribution Centered Toxics Mobility Vulnerability Index (CDC-TMVI) consolidates climate change and topography variables into a broader built environment vulnerability category while introducing a contamination sources category. Using ArcGIS Pro and ToxPi tools, the study evaluates 27 geospatial variables across four categories: built environment vulnerability, social vulnerability, health outcomes, and contamination sources. The results indicate significant contributions from contamination and social vulnerability variables, highlighting areas with higher risks of flooding and air pollution. This article advocates for future research and policy efforts to enhance the integration of contamination sources and their spatial distributions into toxics mobility assessments to better protect vulnerable populations. Furthermore, the unique methodology and findings serve as a basis for developing targeted measures and strategic planning to improve environmental health.

contamination↗

Closure Report for Corrective Action Unit 573: Alpha Contaminated Sites Nevada National Security Site, Nevada with ROTC 1

This Closure Report (CR) presents information supporting the closure of Corrective Action Unit (CAU) 573: Alpha Contaminated Sites, Nevada National Security Site, Nevada. CAU 573 comprises the two corrective action sites (CASs): 05-23-02-GMX Alpha Contaminated Are-Closure in Place and 05-45-01-Atmospheric Test Site - Hamilton- Clean Closure. The purpose of this CR is to provide justification and documentation supporting the recommendation that no further corrective action is needed for CAU 573 based on the implementation of the corrective actions. Corrective action activities were performed at Hamilton from May 25 through June 30, 2016; and at GMX from May 25 to October 27, 2016, as set forth in the Corrective Action Decision Document (CADD)/Corrective Action Plan (CAP) for Corrective Action Unit 573: Alpha Contaminated Sites; and in accordance with the Soils Activity Quality Assurance Plan, which establishes requirements, technical planning, and general quality practices. Verification sample results were evaluated against data quality objective criteria developed by stakeholders that included representatives from the Nevada Division of Environmental Protection and the DOE, National Nuclear Security Administration Nevada Field Office (NNSA/NFO) during the corrective action alternative (CAA) meeting held on November 24, 2015. Radiological doses exceeding the final action level were assumed to be present within the high contamination areas associated with CAS 05-23-02, thus requiring corrective action. It was also assumed that radionuclides were present at levels that require corrective action within the soil/debris pile associated with CAS 05-45-01. During the CAU 573 CAA meeting, the CAA of closure in place with a use restriction (UR) was selected by the stakeholders as the preferred corrective action of the high contamination areas at CAS 05-23-02 (GMX), which contain high levels of removable contamination; and the CAA of clean closure was selected by the stakeholders as preferred corrective action for the debris pile at CAS 05-45-01 (Hamilton). The closure in place was accomplished by posting signs containing a warning label on the existing contamination area fence line; and recording the FFACO UR and administrative UR in the FFACO database, the NNSA/NFO CAU/CAS files, and the management and operating contractor Geographic Information Systems. The clean closure was accomplished by excavating the soil/debris pile, disposing of the contents at the Area 5 Radioactive Waste Management Complex, and collecting verification samples. The corrective actions were implemented as stipulated in the CADD/CAP, and verification sample results confirm that the criteria for the completion of corrective actions have been met. Based on the implementation of these corrective actions, NNSA/NFO provides the following recommendations: No further corrective actions are necessary for CAU 573; The Nevada Division of Environmental Protection should issue a Notice of Completion to NNSA/NFO for closure of CAU 573; CAU 573 should be moved from Appendix III to Appendix IV of the FFACO.

54 ENVIRONMENTAL SCIENCES↗

Assessment of the Impact of the Single Stream Recycling on Paper Contamination in Recovery Facilities and Paper Mills

Contaminated recyclables pose one of the largest roadblocks to an effective implementation of a circular economy system. Current knowledge surrounding the effects of various recycling methods on contamination rates is limited, thus preventing effective quantification of contamination effects. This study aims to fill this knowledge gap by assessing the impact of single stream recycling on paper contamination in MRFs and their end-products based on different composition studies conducted by facilities nationwide. This project expects to provide the foundational knowledge that could catalyze significant cost savings and energy consumption at MRFs and paper mills by understanding the levels of inbound and outbound contamination rates in SSR systems. Statistical analysis conducted in this project utilizes the available nationwide inbound and outbound samples collected as part of material composition and audit studies to identify and measure the significance of various factors on the resultant contamination levels. The research results provide benefits to both the recycling industry and its customers by addressing the causes and impact of contamination in recycled products, particularly with the wide applicability of single stream recycling within the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Contaminant Source Identification from Finite Sensor Data: Perron–Frobenius Operator and Bayesian Inference

Sensors in the built environment ensure safety and comfort by tracking contaminants in the occupied space. In the event of contaminant release, it is important to use the limited sensor data to rapidly and accurately identify the release location of the contaminant. Identification of the release location will enable subsequent remediation as well as evacuation decision-making. In previous work, we used an operator theoretic approach—based on the Perron–Frobenius (PF) operator—to estimate the contaminant concentration distribution in the domain given a finite amount of streaming sensor data. In the current work, the approach is extended to identify the most probable contaminant release location. The release location identification is framed as a Bayesian inference problem. The Bayesian inference approach requires considering multiple release location scenarios, which is done efficiently using the discrete PF operator. The discrete PF operator provides a fast, effective and accurate model for contaminant transport modeling. The utility of our PF-based Bayesian inference methodology is illustrated using single-point release scenarios in both two and three-dimensional cases. The method provides a fast, accurate, and efficient framework for real-time identification of contaminant source location.

42 ENGINEERING↗

Contamination Results of MISSE 8 Wake and Nadir Samples After 2 Years of Space Exposure on the International Space Station

Spacecraft in low Earth orbit (LEO) are subjected to harsh environmental conditions, including radiation (cosmic rays, ultraviolet, x-ray and charged particle radiation), micrometeoroids and orbital debris, temperature extremes, thermal cycling, and atomic oxygen. In addition, on-orbit spacecraft contamination is a serious spaceflight issue, with silicone contamination being a particular concern. In an effort to understand on-orbit contamination of Materials International Space Station Experiment 8 (MISSE 8) flight samples and other International Space Station (ISS) payloads, contamination studies were conducted post-flight on retrieved Teflon fluorinated ethylene propylene (FEP) samples flown in the wake and nadir orientations on MISSE 8. The wake sample was Teflon FEP (M8-W11) flown as part of the Glenn MISSE 8 Polymers Experiment on the Optical Reflector Materials Experiment-III Ram/Wake (ORMatE-III R/W) tray and exposed to the LEO wake environment for 2.0 years. The nadir samples were silver-Teflon FEP radiator pieces taken from the MISSE 8 Single Events Upset Xilinx-Sandia Experiment II (SEUXSE II) Power Box and exposed to the LEO nadir environment for 2.14 years. The Teflon FEP flight materials were analyzed for changes in surface morphology and chemistry as compared to pristine control samples. The wake samples were also analyzed for changes in optical properties. There was no evidence of a molecular contamination layer present on the surface of the MISSE 8 wake or nadir facing Teflon FEP flight samples, although both the wake and nadir flight samples contained particulate contamination in some regions. The analyzed nadir particles were primarily zinc rich. The majority of analyzed wake particles were comprised of oxidized aluminum with small amounts of zinc and magnesium. The wake particles appear to have arrived early in the mission (or pre-flight) during a single event. This paper provides details of the MISSE 8 sample contamination analyses.

Erosion↗

Radioactive Contamination Tenacity on Building Substrate - 17417

Radiological decontamination is an essential enterprise that has become more important over the last four decades due to unfortunate accidents and the threat of terrorist actions. Decontamination can be an effective, beneficial alternative for the cleanup of radiological contamination events; however, the costs and benefits need to be balanced against those for complete removal and demolition of contaminated areas or facilities. Demolition and removal are often the first options considered in such circumstances as decontamination may be thought of as slow and costly. Decontamination has advantages, including significant waste reduction over demolition. In areas with buildings of cultural or societal importance, demolition may not be an option. Three decontamination evaluation test series are the focus of this article: SIMCON 1 and 2 (i.e., simulated contamination), and Urban RDD (radiological dispersal device, i.e., a dirty bomb detonation). These test series revealed that different contaminants respond differently during decontamination. This was found to be true with both SIMCON and Urban RDD simulant tests. SIMCON 2 especially demonstrated that chemically different contaminants respond differently to different decontamination methods: cesium appears to be less tenacious (more easily removed) than zirconium using chemical methods. These differences were underscored by the Urban RDD tests where americium and cobalt tended to precipitate on high pH surfaces (such as concrete), making them easier to remove, while cesium and strontium were essentially unaffected by surface pH and were imbibed more strongly into the substrate pore structure. While authorities argue over the contributions of contaminant chemistry and substrate morphology, the clear answer is that each has a contribution to the tenacity of a contaminant. Knowing how these characteristics interact will make us better at decontamination in the field. This knowledge refutes the efforts of perhaps well-meaning marketers to define our decontamination problems by what products they are trying to sell; often a 'one size fits all' type approach. Knowing even a little bit about the character of the decontamination problem will save time and money and increase the efficacy of decontamination. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Contamination Characteristics of Concrete by Radio-Cs in Off-site Concrete - 18284

To obtain the penetration information of radio-cesium (r-Cs) in concrete, useful for the decommissioning or decontamination of contaminated concrete structures, Cs distributions are evaluated for real contaminated concrete near the Fukushima Daiichi nuclear power plant. The results showed that, for many road-related concrete samples, the contamination was limited to the surface. In other cases, the surface was contaminated and contamination at depths of a few millimeters was observed. The contamination on the surface was not water soluble; therefore, it was easy to reduce contamination using a water jet. Where cracks were observed in the concrete, r-Cs penetrated at least 10 cm deep. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Decontamination Experiments and Simulations Supporting Recovery After Widespread Contamination - 18685

Clean-up after an uncontrolled nuclear material release differs from common decontamination practices in the nuclear industry and military combat scenarios. Uncontrolled releases, particularly acts of terror, require specific protective actions guides (PAGs) to optimize short and long-term repercussions. Ideally, non-destructive decontamination methods would be employed. To help fulfill this need, the IWATERS (Integrated Wash Aid Treatment Emergency Reuse System) was proposed in 2014 for remediation outside the immediate blast area. 'Wash-Aid' is hosed onto affected areas, and the used wash solution is collected and recycled through sand/clay beds. To help characterize the IWATERS technology, the below was completed: - Decontamination experiments with a pressurized wash solution using Cs-137, Sr- 85, and Eu-152 contaminants on porous urban materials. - Sensitivity analyses on recycling bed variables using GoldSim{sup TM} CT. - A proposed framework that expands the recycling bed model to include probabilistic simulation of immediate recovery efforts. Removal efficacy of tap water and 0.5 M KCl were compared for Cs, Sr, and Eu across asphalt, brick, and concrete. The 0.5 M KCl solution significantly outperformed tap water in every case except for Eu on concrete and Cs on brick. Trends in the high-pressure decontamination with salt additive compared to low pressure decontamination show evidence of physical and chemical removal. Variations in cleaning rate yielded no significant trend. Pressure changes (by adjusting nozzle-to-coupon distance) were only significant for the highest pressure. Hypothetical Contamination Scenario: To tie the decontamination experiments and recycling bed model together, a small contamination scenario was created. Imagine the sides of a small concrete building uniformly contaminated with Cs-137. Power washing the building with 0.5 M KCl solution would result in 857 L of contaminated solution generated in 185 minutes. Two sand clay beds were designed to clean the used solution. With a sand mass fraction of 0.9, a 10 ft{sup 2} bed 4 ft tall could recycle the solution in 1.05 hrs. Changing the sand mass fraction to 0.5 yielded a 2.5 ft{sup 2} bed 4 ft tall (∼55-gallon drum) that recycled the solution in 7.43 hrs. This exercise showed how the sand/clay bed design can easily change to match the primary remediation goals. The second sand/clay bed would reduce the waste generation while the first bed reduces the remediation time. Conclusions: Variations on speed and nozzle distance (pressure) yielded insignificant differences in efficacy except for the closest distance. High-pressure washing showed increased decontamination efficacy with KCl additive in the majority of cases. Except for bed composition, key recycling bed parameters can be varied on-the-fly. This allows for optimization of, for example, time and waste generation. The hypothetical contamination scenario showed pairing decontamination experiment results with modeling tools can lead to increased preparedness for a large-scale contamination event. With collaboration and time, an expanded recovery/remediation model could aid in development of effective protective action guides.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stabilization of Residual Contamination with Alternative Materials - 19404

Since 2015, Savannah River National Laboratory (SRNL) in conjunction with Florida International University (FIU) have been investigating the applicability of intumescent coatings as radiological contamination fixatives for stabilization of residual materials after decontamination efforts have concluded. Intumescent coatings are designed to prevent heat transfer to a protected substrate and are typically used in both the aerospace industry to protect components from thermal shock and in building design to protect building joints that may fail in the event of a fire. For this work, these materials are examined for their ability to reduce worker risk by fixating residual contamination and lower the impact of a release in a scenario that breaches containment of a contaminated building and subsequently induces a large-scale fire by crediting their fire-retardant attributes. Initial studies of intumescent coatings and commercial fixatives included performance in direct flame, varied environmental conditions (20-110 F or -6.67 C, 10-95% relative humidity), adhesion studies to stainless steel after curing in varied environmental conditions, and radiological exposure. Of all the materials tested, many were found to be inadequate in one or more of these areas. These materials failed in one or more of three characteristic ways: 1) through delamination at reduced temperatures (≤40 F or 4.44 C) or from even moderate handling, 2) melting off the substrate at elevated temperatures (≥90 F or 32.22 C), 3) proving to be flammable and promote smoke propagation. Failure in these ways results in the potential for a subsequent release of the fixated contamination in the event of water presence/absence or direct flame. Using these results as a platform for the best in class identified material that did not experience failure in any of these tests, SRNL and FIU targeted the plutonium-238 contaminated hot cells within Savannah River Site (SRS) Building 235-F as a characteristic test bed to benchmark an intumescent coating used as a contaminant fixative. Through discussion with the SRS 235-F Risk Reduction personnel, appropriate hazards and performance metrics were discussed and a cold demonstration was performed in a hot cell mockup located at SRS. The application methods were proven functional in the cold mock up, and these intumescent coatings were subsequently utilized in the Savannah River Site Building 235-F's Plutonium Fuel Form (PuFF) Facility to aid in stabilization of plutonium-238 in both a contaminated hot cell and Entry Hood in September 2018. Presented in this work is the overview of the application process, associated working considerations for introduction of equipment and materials into the facility, lessons learned, and lifetime monitoring data to date. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Updates to a Preliminary Probabilistic Performance Assessment Model for Radiological and Chemical Contamination at the West Valley Site, New York - 20420

The New York State Energy Research and Development Authority (NYSERDA) is the owner of the Western New York Nuclear Service Center (WNYNSC), a 1,351-ha site located approximately 48 km south of Buffalo, New York. In 1962, Nuclear Fuel Services, Inc. (NFS) entered into agreements with the Atomic Energy Commission and New York State to construct the first commercial reprocessing plant of nuclear fuel in the United States at the WNYNSC. NFS built and operated the spent fuel reprocessing plant and waste disposal facilities, processing 640 Mg (640 metric tons) of spent nuclear fuel from 1966 to 1972 under an Atomic Energy Commission license. Nuclear fuel reprocessing operations halted in 1972 and never restarted, leaving behind radioactive and chemical wastes. The U.S. Department of Energy (DOE) was required to complete certain waste management activities under the West Valley Demonstration Project (WVDP) Act of 1980 including decommissioning of WVDP facilities. As collaborating agencies, NYSERDA and the DOE are tasked with making decisions about decommissioning and risk reduction for the West Valley Site. Neptune and Company, Inc. (Neptune) was contracted to develop a probabilistic performance assessment (PPA) model to assist the agencies in their decision making process for decommissioning the WVDP and WNYNSC. One important tool that is needed in order to inform the decision-making process is a science-based model of the West Valley Site that evaluates potential future consequences for human health and the environment. This forms the core of the spatial domain of the West Valley PPA Model. The PPA Model, developed using the GoldSim system modeling software, is a tool intended to provide support for decision making that evaluates uncertainty, in a manner that is transparent, defensible, and robust. The PPA Model includes contaminant transport and health effects components, and is organized around geographically-grouped contaminated facilities. These include the waste disposal areas licensed by the U.S. Nuclear Regulatory Commission and the State of New York, a waste tank farm for storage of high level radioactive waste resulting from reprocessing operations, and several areas contaminated with radioactive and chemical constituents. The PPA Model evaluates contaminant transport from these sources to points of exposure across the site and into receiving surface waters and sediments. Hypothetical people and wildlife could be exposed to contamination at these locations, and the effects of these exposures are evaluated. Contaminant transport processes to be evaluated in the PPA Model include groundwater and surface water transport, contaminant translocation by plants and animals, diffusion, and erosion. The evaluation of exposures to people in this preliminary model is limited to a resident farmer scenario, and ecological assessment is performed at the level of a screening analysis. The results of these preliminary evaluations inform future model developments. PPA Model results are subjected to sensitivity analysis in order to determine those pathways and parameters that are most significant in influencing the results. This information allows analysts and decision makers to focus on those aspects of Site behavior and processes. With this information, the decision makers can drive informed, defensible decisions regarding decommissioning of the Site. This paper includes an update of the information presented at WM2019 [1]. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impacts on product quality attributes of monoclonal antibodies produced in CHO cell bioreactor cultures during intentional mycoplasma contamination events

Abstract A mycoplasma contamination event in a biomanufacturing facility can result in costly cleanups and potential drug shortages. Mycoplasma may survive in mammalian cell cultures with only subtle changes to the culture and penetrate the standard 0.2‐µm filters used in the clarification of harvested cell culture fluid. Previously, we reported a study regarding the ability of Mycoplasma arginini to persist in a single‐use, perfusion rocking bioreactor system containing a Chinese hamster ovary (CHO) DG44 cell line expressing a model monoclonal immunoglobulin G 1 (IgG1) antibody. Our previous work showed that M. arginini affects CHO cell growth profile, viability, nutrient consumption, oxygen use, and waste production at varying timepoints after M. arginini introduction to the culture. Careful evaluation of certain identified process parameters over time may be used to indicate mycoplasma contamination in CHO cell cultures in a bioreactor before detection from a traditional method. In this report, we studied the changes in the IgG1 product quality produced by CHO cells considered to be induced by the M. arginini contamination events. We observed changes in critical quality attributes correlated with the duration of contamination, including increased acidic charge variants and high mannose species, which were further modeled using principal component analysis to explore the relationships among M. arginini contamination, CHO cell growth and metabolites, and IgG1 product quality attributes. Finally, partial least square models using NIR spectral data were used to establish predictions of high levels (≥10 4 colony‐forming unit [CFU/ml]) of M. arginini contamination, but prediction of levels below 10 4 CFU/ml were not reliable. Contamination of CHO cells with M. arginini resulted in significant reduction of antibody product quality, highlighting the importance of rapid microbiological testing and mycoplasma testing during particularly long upstream bioprocesses to ensure product safety and quality.

60 APPLIED LIFE SCIENCES↗

Contaminants in tropical island streams and their biota

Highlights: • Puerto Rico is a model environment to study contaminants in tropical island streams. • Water, sediment, and native fish and shrimp species were sampled in 13 rivers. • Stream habitat and biota were not severely polluted due to frequent flushing flows and floods. • Results may inform human health and development of fish consumption guidelines for Puerto Rico. Environmental contamination is problematic for tropical islands due to their typically dense human populations and competing land and water uses. The Caribbean island of Puerto Rico (USA) has a long history of anthropogenic chemical use, and its human population density is among the highest globally, providing a model environment to study contaminant impacts on tropical island stream ecosystems. Polycyclic Aromatic Hydrocarbons, historic-use chlorinated pesticides, current-use pesticides, Polychlorinated Biphenyls (PCBs), and metals (mercury, cadmium, copper, lead, nickel, zinc, and selenium) were quantified in the habitat and biota of Puerto Rico streams and assessed in relation to land-use patterns and toxicological thresholds. Water, sediment, and native fish and shrimp species were sampled in 13 rivers spanning broad watershed land-use characteristics during 2009–2010. Contrary to expectations, freshwater stream ecosystems in Puerto Rico were not severely polluted, likely due to frequent flushing flows and reduced deposition associated with recurring flood events. Notable exceptions of contamination were nickel in sediment within three agricultural watersheds (range 123–336 ppm dry weight) and organic contaminants (PCBs, organochlorine pesticides) and mercury in urban landscapes. At an urban site, PCBs in several fish species (Mountain Mullet Agonostomus monticola [range 0.019–0.030 ppm wet weight] and American Eel Anguilla rostrata [0.019–0.031 ppm wet weight]) may pose human health hazards, with concentrations exceeding the U.S. Environmental Protection Agency (EPA) consumption limit for 1 meal/month. American Eel at the urban site also contained dieldrin (range < detection-0.024 ppm wet weight) that exceeded the EPA maximum allowable consumption limit. The Bigmouth Sleeper Gobiomorous dormitor, an important piscivorus sport fish, accumulated low levels of organic contaminants in edible muscle tissue (due to its low lipid content) and may be most suitable for human consumption island-wide; only mercury at one site (an urban location) exceeded EPA's consumption limit of 3 meals/month for this species. These results comprise the first comprehensive island-wide contaminant assessment of Puerto Rico streams and biota and provide natural resource and public health agencies here and in similar tropical islands elsewhere with information needed to guide ecosystem and fisheries conservation and management and human health risk assessment.

54 ENVIRONMENTAL SCIENCES↗

Decontamination of urban surfaces contaminated with radioactive materials and consequent onsite recycling of the waste water

Enhancing rapid remediation strategies is paramount for recovery after a large-scale nuclear contamination event in an urban environment. Some current strategies recommend use of readily available equipment, materials, and facilities to expedite recovery. For example, applying pressurized water to contaminated surfaces may effectively remove radioactive contamination. In this study, a commercial power washer removes soluble forms of 152 Eu 3 + , 85 Sr 2 + , and 137 Cs + contamination from common porous building materials, and computer simulations characterize the recycling of the resultant contaminated wash water. Pressure washing the porous building materials under spray conditions typical with do-it-yourself units improved decontamination factors (DFs) for 152 Eu compared to low-pressure application of tap water (majority of two-tailed t-test p-values < 0.1), but pressure did not improve DFs for 137 Cs or 85 Sr. For both pressurized and low-pressure applications, adding potassium ions (K + ) to promote ion exchange reactions produced significantly higher DFs for tested radionuclides on asphalt, brick, and concrete. The resultant contaminated wash water can be processed through self-prepared chemical filtration beds of clay and sand. Modeled in a prior study, the beds yielded linear trends (R 2 > 0.98) in sensitivity analyses between most bed configuration variables and bed performance variables, permitting flexible ad-hoc bed design. The experimental and simulation results led to estimates of the remediation rate and waste generated after cleaning 250 m 2 of cesium-contaminated concrete from the combined deployment of a power washer and two different mobile treatment beds. Furthermore, the first treatment bed was designed to reduce treatment time and processed 1900 L of wash solution in 70 min using 880 kg of clay/sand infill material. Designed to reduce the solid waste generated, the second bed processed the same solution volume in 1040 min (17 h) using 170 kg of clay/sand infill material. The results of this analysis warrant further investigation of power washing with recycled salt solution as an effective rapid decontamination method with manageable waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In Situ Monitoring of Groundwater Contamination Using the Kalman Filter

This study presents a Kalman filter-based framework to establish a real-time in situ monitoring system for groundwater contamination based on in situ measurable water quality variables, such as specific conductance (SC) and pH. First, this framework uses principal component analysis (PCA) to identify correlations between the contaminant concentrations of interest and in situ measurable variables. It then applies the Kalman filter to estimate contaminant concentrations continuously and in real-time by coupling data-driven concentration-decay models with the previously identified data correlations. We demonstrate our approach with historical groundwater data from the Savannah River Site F-Area: We use SC and pH data to estimate tritium and uranium concentrations over time. Results show that the developed method can estimate these contaminant concentrations based on in situ measurable variables. The estimates remain reliable with less frequent or no direct measurements of the contaminant concentrations, while capturing the dynamics of short- and long-term contaminant concentration changes. In addition, we show that data mining, such as PCA, is useful to understand correlations in groundwater data and to design long-term monitoring systems. As a result, the developed in situ monitoring methodology is expected to improve long-term groundwater monitoring by continuously confirming the contaminant plume's stability and by providing an early warning system for unexpected changes in the plume's migration.

54 ENVIRONMENTAL SCIENCES↗

Solvent-mediated contaminant removal from plastic waste using thermodynamic modeling

Plastics recycling is hindered by the compositional complexity of plastic waste, which can include numerous polymer components as well as low concentrations of additives and non-intentionally added substances. These latter small-molecule species, which we collectively refer to as contaminants, can harm human health and will build up in recycled plastic causing environmental and downstream processing challenges if not removed. In this work, we present molecular modeling approaches using the COnductor-like Screening MOdel for Real Solvents (COSMO-RS) to guide the selection of solvents that are capable of removing targeted contaminants from plastic waste. By considering the thermodynamic partitioning of contaminant species between a solvent phase and polymer phase, we identify guidelines for solvent selection to promote either the low-temperature extraction of contaminants from plastic waste or the removal of contaminants as part of a dissolution-based plastics recycling process. We present four case studies to illustrate the application of the computational approach to the removal of brominated flame retardants, phthalates, and selected perfluoroalkyl substances, and compare to both literature and newly collected experimental data to illustrate model prediction accuracy. Furthermore, the case studies highlight the capability of the modeling approach to help design recycling processes that explicitly account for contaminant removal, thereby increasing product purity during dissolution-based recycling or facilitating chemical recycling of contaminant-free plastics.

Zhou, Panzheng [University of, Wisconsin, Madison,↗

Accumulation of trace elements in soil and fauna within a site historically contaminated with coal combustion residues

Legacy contaminants tied to energy production are a worldwide concern. Coal combustion residues (CCRs) contain high concentrations of potentially toxic trace elements such as arsenic (As), mercury (Hg), and selenium (Se), which can persist for decades after initial contamination. Coal combustion residue disposal methods, including aquatic settling basins and landfills, can facilitate environmental exposure through intentional and accidental releases. Wildlife exposed to CCRs can experience numerous deleterious effects, such as on development, reproduction, and survival. In the current study, we quantified and compared concentrations of As, Hg, Se, and strontium (Sr) within soils and target fauna (three vertebrate and three invertebrate taxa) from a CCR-contaminated site and a reference site within the U.S. Department of Energy’s Savannah River Site, South Carolina, United States. Our objectives were to (1) compare current concentrations of tested elements in soil and resident fauna to levels from our reference site, (2) assess natural attenuation of elements in soils by comparing current concentrations to historic levels, and (3) evaluate the biomagnification potential of the elements measured via body burden and trophic position correlations among fauna. Here, element concentrations were higher in contaminated soils than reference soils; however, concentrations in 2022 were unchanged from concentrations measured in 2003, suggesting no natural attenuation of tested elements. Additionally, target fauna had elevated As, Se, and Sr levels in comparison to reference samples. A positive correlation was observed in southern toads between Sr concentrations and trophic position, as assessed by nitrogen stable isotope ratios, suggesting potential for biomagnification of Sr within our study system. Collectively, our results demonstrate that legacy contaminants are still present and bioaccumulate in a diversity of taxa in a CCR-contaminated site that has not received effluents in more than 50 years, suggesting monitoring programs in CCR-contaminated sites should be maintained long term in the absence of remediation.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Correcting correlation functions for redshift-dependent interloper contamination

ABSTRACT The construction of catalogues of a particular type of galaxy can be complicated by interlopers contaminating the sample. In spectroscopic galaxy surveys this can be due to the misclassification of an emission line; for example in the Hobby–Eberly Telescope Dark Energy Experiment (HETDEX) low-redshift [O ii] emitters may make up a few per cent of the observed Ly α emitter (LAE) sample. The presence of contaminants affects the measured correlation functions and power spectra. Previous attempts to deal with this using the cross-correlation function have assumed sources at a fixed redshift, or not modelled evolution within the adopted redshift bins. However, in spectroscopic surveys like HETDEX, where the contamination fraction is likely to be redshift dependent, the observed clustering of misclassified sources will appear to evolve strongly due to projection effects, even if their true clustering does not. We present a practical method for accounting for the presence of contaminants with redshift-dependent contamination fractions and projected clustering. We show using mock catalogues that our method, unlike existing approaches, yields unbiased clustering measurements from the upcoming HETDEX survey in scenarios with redshift-dependent contamination fractions within the redshift bins used. We show our method returns autocorrelation functions with systematic biases much smaller than the statistical noise for samples with at least as high as 7 per cent contamination. We also present and test a method for fitting for the redshift-dependent interloper fraction using the LAE–[O ii] galaxy cross-correlation function, which gives less biased results than assuming a single interloper fraction for the whole sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance Losses and Current-Driven Recovery from Cation Contaminants in PEM Water Electrolysis

Water contaminants are a common cause of failure for polymer electrolyte membrane (PEM) electrolyzers in the field as well as a confounding factor in research on cell performance and durability. In this study, we investigated the performance impacts of feed water containing representative tap water cations at concentrations ranging from 0.5–500 μ M, with conductivities spanning from ASTM Type II to tap-water levels. We present multiple diagnostic signatures to help identify the presence of contaminants in PEM electrolysis cells. Through analysis of polarization curves and impedance spectroscopy to understand the origins of performance losses, we found that a switch from the acidic to alkaline hydrogen evolution mechanism is a key factor in contaminated cell behavior. Finally, we demonstrated that this mechanism switching can be harnessed to remove cation contaminants and recover cell performance without the use of an acid wash. We demonstrated near-complete recovery of cells contaminated with sodium and calcium, and partial recovery of a cell contaminated with iron, which was further investigated by post-mortem microscopy. The improved understanding of contaminant impacts from this work can inform development of strategies to mitigate or recover performance losses as well as improve the consistency and rigor of electrolysis research.

30 DIRECT ENERGY CONVERSION↗