Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Analytic analysis of load alignment for coning extreme‐scale rotors

Abstract Extreme‐scale wind turbines (rated powers greater than 10 MW) with large rotor diameters and conventional upwind designs must resist extreme downwind and gravity loads. This can lead to significant structural design challenges and high blade masses that can impede the reduction of levelized cost of wind energy. Herein, the theoretical basis for downwind load alignment is developed. This alignment can be addressed with active downwind coning to reduce/eliminate flapwise bending loads by balancing the transverse components of thrust, centrifugal, and gravitational force. Equations are developed herein that estimates the optimal coning angle that reduces flapwise loads by a specified amount. This analysis is then applied to a 13.2‐MW scale with 100‐m‐level wind turbine blades, where it is found that a load alignment coning schedule can substantially reduce the root flapwise bending moments. This moment reduction in this example can allow the rotor mass to be decreased significantly when compared with a conventional upwind three‐bladed rotor while maintaining structural performance and annual energy output.

Noyes, Carlos↗

Regularization of the light-cone gauge gluon propagator singularities using sub-gauge conditions

Perturbative QCD calculations in the light-cone gauge have long suffered from the ambiguity associated with the regularization of the poles in the gluon propagator. In this work we study sub-gauge conditions within the light-cone gauge corresponding to several known ways of regulating the gluon propagator. By using the functional integral calculation of the gluon propagator, we rederive the known sub-gauge conditions for the θ-function gauges and identify the sub-gauge condition for the principal value (PV) regularization of the gluon propagator’s light-cone poles. The obtained sub-gauge condition for the PV case is further verified by a sample calculation of the classical Yang-Mills field of two collinear ultrarelativistic point color charges. Our method does not allow one to construct a sub-gauge condition corresponding to the well-known Mandelstam-Leibbrandt prescription for regulating the gluon propagator poles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Image-Guided Radiotherapy for Liver Cancer Using Respiratory-Correlated Computed Tomography and Cone-Beam Computed Tomography

Purpose: To evaluate a novel four-dimensional (4D) image-guided radiotherapy (IGRT) technique in stereotactic body RT for liver tumors. Methods and Materials: For 11 patients with 13 intrahepatic tumors, a respiratory-correlated 4D computed tomography (CT) scan was acquired at treatment planning. The target was defined using CT series reconstructed at end-inhalation and end-exhalation. The liver was delineated on these two CT series and served as a reference for image guidance. A cone-beam CT scan was acquired after patient positioning; the blurred diaphragm dome was interpreted as a probability density function showing the motion range of the liver. Manual contour matching of the liver structures from the planning 4D CT scan with the cone-beam CT scan was performed. Inter- and intrafractional uncertainties of target position and motion range were evaluated, and interobserver variability of the 4D-IGRT technique was tested. Results: The workflow of 4D-IGRT was successfully practiced in all patients. The absolute error in the liver position and error in relation to the bony anatomy was 8 {+-} 4 mm and 5 {+-} 2 mm (three-dimensional vector), respectively. Margins of 4-6 mm were calculated for compensation of the intrafractional drifts of the liver. The motion range of the diaphragm dome was reproducible within 5 mm for 11 of 13 lesions, and the interobserver variability of the 4D-IGRT technique was small (standard deviation, 1.5 mm). In 4 patients, the position of the intrahepatic lesion was directly verified using a mobile in-room CT scanner after application of intravenous contrast. Conclusion: The results of our study have shown that 4D image guidance using liver contour matching between respiratory-correlated CT and cone-beam CT scans increased the accuracy compared with stereotactic positioning and compared with IGRT without consideration of breathing motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Radiotherapy With Use of Cone-Down Boost for Pediatric Head-and-Neck Rhabdomyosarcoma

Purpose: To report our initial experience using intensity-modulated radiotherapy (IMRT) with a cone-down boost for pediatric head-and-neck rhabdomyosarcoma (RMS). Methods and Materials: A review of institutional treatment records identified children treated with IMRT for head-and-neck RMS between January 2000 and February 2007. All patients had undergone chemotherapy according to cooperative group RMS protocols. The initial planning target volume (PTV) covered the prechemotherapy tumor extent with variable margins, generally 1-2 cm. The boost PTV covered the postchemotherapy tumor volume, usually with a margin of 0.5-1 cm. Results: A total of 20 patients were treated with IMRT for head-and-neck RMS. Of these 20 patients, 4 had Group II, 15 Group III, and 1 Group IV disease. The site was parameningeal in 12, nonparameningeal in 6, and orbit primary in 2. Of the 20 patients, 14 were treated with a cone-down boost after a median dose of 36 Gy (range, 30-45.6). The mean initial PTV was 213.5 cm{sup 3}, and the mean boost PTV was 76.9 cm{sup 3}. Patients received a median total dose of 50.4 Gy. The median follow-up time was 29 months. The 3-year Kaplan-Meier local control rate was 100%, although 1 patient developed an in-field recurrence 50 months after IMRT. The 3-year event-free survival rate, overall survival rate, and risk of central nervous system failure was 74%, 76%, and 7%, respectively. Conclusions: Our preliminary follow-up of pediatric head-and-neck RMS patients treated with IMRT revealed excellent local control. The initial targeting of the prechemotherapy tumor volume with 1-2-cm margin to 30.6 or 36 Gy followed by a cone-down boost to the postchemotherapy tumor volume with a 0.5-1-cm margin allowed for significant sparing of normal tissues and provided good local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Refinement of Treatment Setup and Target Localization Accuracy Using Three-Dimensional Cone-Beam Computed Tomography for Stereotactic Body Radiotherapy

Purposes: To quantitatively compare two-dimensional (2D) orthogonal kV with three-dimensional (3D) cone-beam CT (CBCT) for target localization; and to assess intrafraction motion with kV images in patients undergoing stereotactic body radiotherapy (SBRT). Methods and Materials: A total of 50 patients with 58 lesions received 178 fractions of SBRT. After clinical setup using in-room lasers and skin/cradle marks placed at simulation, patients were imaged and repositioned according to orthogonal kV/MV registration of bony landmarks to digitally reconstructed radiographs from the planning CT. A subsequent CBCT was registered to the planning CT using soft tissue information, and the resultant 'residual error' was measured and corrected before treatment. Posttreatment 2D kV and/or 3D CBCT images were compared with pretreatment images to determine any intrafractional position changes. Absolute averages, statistical means, standard deviations, and root mean square (RMS) values of observed setup error were calculated. Results: After initial setup to external marks with laser guidance, 2D kV images revealed vector mean setup deviations of 0.67 cm (RMS). Cone-beam CT detected residual setup deviations of 0.41 cm (RMS). Posttreatment imaging demonstrated intrafractional variations of 0.15 cm (RMS). The individual shifts in three standard orthogonal planes showed no obvious directional biases. Conclusions: After localization based on superficial markings in patients undergoing SBRT, orthogonal kV imaging detects setup variations of approximately 3 to 4 mm in each direction. Cone-beam CT detects residual setup variations of approximately 2 to 3 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3D In Vivo Dosimetry Using Megavoltage Cone-Beam CT and EPID Dosimetry

Purpose: To develop a method that reconstructs, independently of previous (planning) information, the dose delivered to patients by combining in-room imaging with transit dose measurements during treatment. Methods and Materials: A megavoltage cone-beam CT scan of the patient anatomy was acquired with the patient in treatment position. During treatment, delivered fields were measured behind the patient with an electronic portal imaging device. The dose information in these images was back-projected through the cone-beam CT scan and used for Monte Carlo simulation of the dose distribution inside the cone-beam CT scan. Validation was performed using various phantoms for conformal and IMRT plans. Clinical applicability is shown for a head-and-neck cancer patient treated with IMRT. Results: For single IMRT beams and a seven-field IMRT step-and-shoot plan, the dose distribution was reconstructed within 3%/3mm compared with the measured or planned dose. A three-dimensional conformal plan, verified using eight point-dose measurements, resulted in a difference of 1.3 {+-} 3.3% (1 SD) compared with the reconstructed dose. For the patient case, planned and reconstructed dose distribution was within 3%/3mm for about 95% of the points within the 20% isodose line. Reconstructed mean dose values, obtained from dose-volume histograms, were within 3% of prescribed values for target volumes and normal tissues. Conclusions: We present a new method that verifies the dose delivered to a patient by combining in-room imaging with the transit dose measured during treatment. This verification procedure opens possibilities for offline adaptive radiotherapy and dose-guided radiotherapy strategies taking into account the dose distribution delivered during treatment sessions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Positioning Accuracy of Four Different Immobilizations Using Cone-Beam CT in Radiotherapy of Non-Small-Cell Lung Cancer

Purpose: To evaluate the positioning accuracy of four different immobilizations by use of cone-beam computed tomography guidance for radiotherapy of non-small-cell lung cancer (NSCLC). Methods and Materials: Sixty-seven patients with NSCLC received conventional or stereotactic body radiotherapy. Of these, 30 were immobilized with a thermoplastic frame (TF), 16 with a thermoplastic frame and active breathing control (TF-ABC), 7 with a stereotactic body frame (SBF), and 14 with a stereotactic body frame and active breathing control (SBF-ABC). Cone-beam computed tomography scans at initial setup and after correction were registered to planning computed tomography. The positional errors in the left-to-right, superior-inferior, and anterior-posterior directions were analyzed. The planning target volume margins were calculated. Results: The precorrection systematic and random errors ranged from 1.9 to 4.2 mm for TF, 1.9 to 4.3 mm for SBF, 1.2 to 5.8 mm for TF-ABC, and 2.3 to 3.9 mm for SBF-ABC. The postcorrection systematic and random errors ranged from 0.3 to 1.9 mm for the four immobilizations. The planning target volume margins (conventional vs. stereotactic body radiotherapy) were 15.6 vs. 13.9 mm (TF), 14.9 vs. 14.8 mm (TF-ABC), 14.4 vs. 13.4 mm (SBF), and 9.9 vs. 9.4 mm (SBF-ABC) before correction and 7.3 vs. 6.9 mm (TF), 4.0 vs. 3.8 mm (TF-ABC), 7.5 vs. 7.1 mm (SBF), and 4.5 vs. 4.2 mm (SBF-ABC) after correction. Conclusions: The positioning accuracies of SBF and TF were similar. Active breathing control increased positioning error but reduced internal margin. Cone-beam computed tomography online correction improved the positioning accuracy of NSCLC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Breath-Hold Target Localization With Simultaneous Kilovoltage/Megavoltage Cone-Beam Computed Tomography and Fast Reconstruction

Purpose: Hypofractionated high-dose radiotherapy for small lung tumors has typically been based on stereotaxy. Cone-beam computed tomography and breath-hold techniques have provided a noninvasive basis for precise cranial and extracranial patient positioning. The cone-beam computed tomography acquisition time of 60 s, however, is beyond the breath-hold capacity of patients, resulting in respiratory motion artifacts. By combining megavoltage (MV) and kilovoltage (kV) photon sources (mounted perpendicularly on the linear accelerator) and accelerating the gantry rotation to the allowed limit, the data acquisition time could be reduced to 15 s. Methods and Materials: An Elekta Synergy 6-MV linear accelerator, with iViewGT as the MV- and XVI as the kV-imaging device, was used with a Catphan phantom and an anthropomorphic thorax phantom. Both image sources performed continuous image acquisition, passing an angle interval of 90{sup o} within 15 s. For reconstruction, filtered back projection on a graphics processor unit was used. It reconstructed 100 projections acquired to a 512 x 512 x 512 volume within 6 s. Results: The resolution in the Catphan phantom (CTP528 high-resolution module) was 3 lines/cm. The spatial accuracy was within 2-3 mm. The diameters of different tumor shapes in the thorax phantom were determined within an accuracy of 1.6 mm. The signal-to-noise ratio was 68% less than that with a 180{sup o}-kV scan. The dose generated to acquire the MV frames accumulated to 82.5 mGy, and the kV contribution was <6 mGy. Conclusion: The present results have shown that fast breath-hold, on-line volume imaging with a linear accelerator using simultaneous kV-MV cone-beam computed tomography is promising and can potentially be used for image-guided radiotherapy for lung cancer patients in the near future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Non-destructive characterisation of polymers and Al-alloys by polychromatic cone-beam phase contrast tomography

X-ray computed tomography (XCT) has become a very important tool for the non-destructive characterisation of materials. Continuous improvements in the quality and performance of X-ray tubes and detectors have led to cone-beam XCT systems that can now achieve spatial resolutions down to 1 {mu}m and even below. Since not only the amplitude but also the phase of an X-ray beam is altered while passing through an object, phase contrast effects can occur even for polychromatic sources when the spatial coherence due to a small focal spot size is high enough. This can lead to significant improvements over conventional attenuation-based X-ray computed tomography. Phase contrast can increase by edge enhancement the visibility of small structures and of features which are only slightly different in attenuation. We report on the possibilities of polychromatic cone-beam phase contrast tomography for non-destructive characterisation of materials. A carbon fibre-reinforced polymer and the Al-alloys AlMg5Si7 and AlSi18 were investigated with high resolution cone-beam X-ray computed tomography with a polychromatic tube source. Under certain conditions strong phase contrast resulting in an upward and downward overshooting of the grey values across edges was observed. The phase effects are much stronger for the polymer than for the Al-alloys. The influence on the phase contrast of the parameters, including source-detector distance, focal spot size and tube acceleration voltage is presented. Maximum phase contrast was observed for a maximum distance between the source and the detector, for a low voltage and a minimum focal spot size at the X-ray source. The detectability of the different phases is improved by the edge enhancement and the resulting improvement of sharpness. Thus, a better segmentation of the carbon fibres in the fibre-reinforced polymer and of the Mg{sub 2}Si-phase in the AlMg5Si7-alloy is achieved. Primary and eutectic Si cannot be detected by attenuation-based X-ray computed tomography due to the small difference in X-ray attenuation between the Si and the Al-matrix in AlSi18. However, phase contrast effects lead to a significant detectability and the large primary Si particles become clearly visible in the tomograms of AlSi18. - Highlights: Black-Right-Pointing-Pointer Phase contrast increases with increasing distance object-detector and with decreasing U, X-ray spot. Black-Right-Pointing-Pointer The detectability of details is improved by the phase contrast. Black-Right-Pointing-Pointer For the carbon fibre-reinforced polymer the visibility of the carbon fibres is improved. Black-Right-Pointing-Pointer For AlMg5Si7 the detectability of the phases Fe-aluminides and Mg{sub 2}Si particles is improved. Black-Right-Pointing-Pointer For AlSi18 primary Si particles with a size > 50 {mu}m become detectable because of the phase contrast.

36 MATERIALS SCIENCE↗

Elastomeric Microchip Electrospray Emitter for Stable Cone-Jet Mode Operation in the Nanoflow Regime.

Despite widespread interest in applying lab-on-a-chip technologies to mass spectrometry (MS)-based analyses, the coupling of microfluidics to electrospray ionization (ESI)-MS remains challenging. We report a robust, integrated poly(dimethylsiloxane) microchip interface for ESI-MS using simple and widely accessible microfabrication procedures. The interface uses an auxiliary channel to provide electrical contact in the Taylor cone of the electrospray without sample loss or dilution. The electric field at the channel terminus is enhanced by two vertical cuts that cause the interface to taper to a line rather than to a point, and the formation of small Taylor cones at the channel exit ensures sub-nL post-column dead volumes. While comparable ESI-MS sensitivities were achieved using both microchip and conventional fused silica capillary emitters, stable cone-jet mode electrospray could be established over a far broader range of flow rates (from 50–1000 nL/min) and applied potentials using the microchip emitters. This special feature of the microchip emitter should minimize the fine tuning required for electrospray optimization and make the stable electrospray more resistant to external perturbations.

Kelly, Ryan T.↗

One-dimensional and multichannels multi-imaging x-ray streak camera for imploded core plasma of shell-cone target

Recently one-dimensional and multichannels multi-imaging x-ray streak camera (1D+McMIXS) has been proposed as an ultrafast diagnostic tool for imploded core plasma of shell-cone target. This diagnostic system can provide much more information of core plasma dynamics, such as the shell trajectory before the maximum compression, two dimensional (2D) x-ray images, and 2D map of electron temperature. The 1D+McMIXS was used in an implosion experiment of a shell target with a cone for fast ignition at Gekko XII laser facility. The interaction between the core plasma and the tip of the cone was observed and revealed some detailed structures. A series of time-resolved 2D x-ray images were reconstructed and a nominal temperature evolution was also mapped.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fokker-Planck simulations for core heating in subignition cone-guiding fast ignition targets

On the basis of two-dimensional coupled relativistic Fokker-Planck and fluid simulations, the core heating by fast electron beam in subignition cone-guiding fast ignition targets is investigated. It was found that the magnetic field due to the thermoelectric current reduces the beam pinching due to the resistive magnetic field. Compared with the carbon-deuterium fuel used in the early phase of Fast Ignition Realization Experiment, phase-I, the core heating of deuterium-tritium (DT) fuel used in the later phase is less effective. One reason is the slower temperature relaxation between bulk electron and ion for the DT case, which is previously reported by Johzaki et al. [Phys. Plasmas 15, 062702 (2008)]. In addition, in the lower-Z DT case, the pinching effects by the resistive magnetic field are weaker due to smaller resistivity; the optical thickness for fast electron beam is smaller, which leads to further reduction in core heating efficiency. It was also found that the fast electron beam quality deteriorates during the transport in the only 10 {mu}m thickness high-Z (e.g., Au and Cu) cone tip because of the collisional scattering and drag. As the result, the core heating efficiency considerably goes down compared to the case neglecting the transport in the cone tip.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Efficient laser absorption and enhanced electron yield in the laser-target interaction by using a cone-nanolayer target

A cone-nanolayer target that combines the advantages of the conical and layered geometries for electron acceleration in laser-target interaction is proposed. Two-dimensional particle-in-cell (PIC) simulations show that the cone-nanolayer target can enhance laser absorption and electron yield. With suitable choice of the laser and target parameters, the cone-nanolayer target can be a controllable source of hot electrons at desired energy ranges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-quality proton bunch from laser interaction with a gas-filled cone target

Generation of high-energy proton bunch from interaction of an intense short circularly polarized (CP) laser pulse with a gas-filled cone target (GCT) is investigated using two-dimensional particle-in-cell simulation. The GCT target consists of a hollow cone filled with near-critical gas-plasma and a thin foil attached to the tip of the cone. It is observed that as the laser pulse propagates in the gas-plasma, the nonlinear focusing will result in an enhancement of the laser pulse intensity. It is shown that a large number of energetic electrons are generated from the gas-plasma and accelerated by the self-focused laser pulse. The energetic electrons then transports through the foil, forming a backside sheath field which is stronger than that produced by a simple planar target. A quasi-monoenergetic proton beam with maximum energy of 181 MeV is produced from this GCT target irradiated by a CP laser pulse at an intensity of 2.6 x 10{sup 20} W/cm{sup 2}, which is nearly three times higher compared to simple planar target (67 MeV).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dirac cones in artificial structures of 3d transitional-metals doped Mg-Al spinels

Motivated by recent theoretical predications for Dirac cone in two-dimensional (2D) triangular lattice [H. Ishizuka, Phys. Rev. Lett. 109, 237207 (2012)], first-principles studies are performed to predict Dirac cones in artificial structures of 3d transitional-metals (TM = Ti, V, Cr, Mn, Fe, Co, Ni, and Cu) doped Mg-Al spinels. In investigated artificial structures, TM dopants substitute specific positions of the B sub-lattice in Mg-Al spinel, and form a quasi-2D triangular lattice in the a-b plane. Calculated results illustrate the existence of the spin-polarized Dirac cones formed in d-wave bands at (around) the K-point in the momentum space. The study provides a promising route for engineering Dirac physics in condensed matters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamics of compressional Mach cones in a strongly coupled complex plasma

Using a Generalised-Hydrodynamic (GH) fluid model, we study the influence of strong coupling induced modification of the fluid compressibility on the dynamics of compressional Mach cones in a dusty plasma medium. A significant structural change of lateral wakes for a given Mach number and Epstein drag force is found in the strongly coupled regime. With the increase of fluid compressibility, the peak amplitude of the normalised perturbed dust density first increases and then decreases monotonically after reaching its maximum value. It is also noticed that the opening angle of the cone structure decreases with the increase of the compressibility of the medium and the arm of the Mach cone breaks up into small structures in the velocity vector profile when the coupling between the dust particles increases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging

X-ray luminescence tomography (XLT) is an imaging technology based on X-ray-excitable materials. The main purpose of this paper is to obtain quantitative luminescence concentration using the structural information of the X-ray computed tomography (XCT) in the hybrid cone beam XLT/XCT system. A multi-wavelength luminescence cone beam XLT method with the structural a priori information is presented to relieve the severe ill-posedness problem in the cone beam XLT. The nanophosphors and phantom experiments were undertaken to access the linear relationship of the system response. Then, an in vivo mouse experiment was conducted. The in vivo experimental results show that the recovered concentration error as low as 6.67% with the location error of 0.85 mm can be achieved. The results demonstrate that the proposed method can accurately recover the nanophosphor inclusion and realize the quantitative imaging.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dirac cones in transition metal doped boron nitride

The transition metal (TM) doped zinc blende boron nitride (c-BN) is studied by using the first principle calculation. TM atoms fill in the interstitials in c-BN and form two-dimensional honeycomb lattice. The generalized gradient approximation and projector augmented wave method are used. The calculated density of states and band structures show that d electrons of TM atoms form impurity bands in the gap of c-BN. When the TM-BN system is in ferromagnetic or non-magnetic state, Dirac cones emerge at the K point in Brillouin zone. When TM is Ti and Co, the Dirac cones are spin polarized and very close to the Fermi level, which makes them promising candidates of Dirac half-metal [H. Ishizuka and Y. Motome, Phys. Rev. Lett. 109, 237207 (2012)]. While TM is Ni and Cu, the system is non-magnetic and Dirac cones located above the Fermi level.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗